Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = intra-arch mechanics

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1713 KiB  
Article
Hemodynamic Effect of Pulsatile on Blood Flow Distribution with VA ECMO: A Numerical Study
by Kaiyun Gu, Sizhe Gao, Zhe Zhang, Bingyang Ji and Yu Chang
Bioengineering 2022, 9(10), 487; https://doi.org/10.3390/bioengineering9100487 - 20 Sep 2022
Cited by 8 | Viewed by 4918
Abstract
The pulsatile properties of arterial flow and pressure have been thought to be important. Nevertheless, a gap still exists in the hemodynamic effect of pulsatile flow in improving blood flow distribution of veno-arterial extracorporeal membrane oxygenation (VA ECMO) supported by the circulatory system. [...] Read more.
The pulsatile properties of arterial flow and pressure have been thought to be important. Nevertheless, a gap still exists in the hemodynamic effect of pulsatile flow in improving blood flow distribution of veno-arterial extracorporeal membrane oxygenation (VA ECMO) supported by the circulatory system. The finite-element models, consisting of the aorta, VA ECMO, and intra-aortic balloon pump (IABP) are proposed for fluid-structure interaction calculation of the mechanical response. Group A is cardiogenic shock with 1.5 L/min of cardiac output. Group B is cardiogenic shock with VA ECMO. Group C is added to IABP based on Group B. The sum of the blood flow of cardiac output and VA ECMO remains constant at 4.5 L/min in Group B and Group C. With the recovery of the left ventricular, the flow of VA ECMO declines, and the effective blood of IABP increases. IABP plays the function of balancing blood flow between left arteria femoralis and right arteria femoralis compared with VA ECMO only. The difference of the equivalent energy pressure (dEEP) is crossed at 2.0 L/min to 1.5 L/min of VA ECMO. PPI’ (the revised pulse pressure index) with IABP is twice as much as without IABP. The intersection with two opposing blood generates the region of the aortic arch for the VA ECMO (Group B). In contrast to the VA ECMO, the blood intersection appears from the descending aorta to the renal artery with VA ECMO and IABP. The maximum time-averaged wall shear stress (TAWSS) of the renal artery is a significant difference with or not IABP (VA ECMO: 2.02 vs. 1.98 vs. 2.37 vs. 2.61 vs. 2.86 Pa; VA ECMO and IABP: 8.02 vs. 6.99 vs. 6.62 vs. 6.30 vs. 5.83 Pa). In conclusion, with the recovery of the left ventricle, the flow of VA ECMO declines and the effective blood of IABP increases. The difference between the equivalent energy pressure (EEP) and the surplus hemodynamic energy (SHE) indicates the loss of pulsation from the left ventricular to VA ECMO. 2.0 L/min to 1.5 L/min of VA ECMO showing a similar hemodynamic energy loss with the weak influence of IABP. Full article
Show Figures

Figure 1

12 pages, 8226 KiB  
Case Report
A Simple Technique Using a Modified Nance Appliance as Anchorage for Maxillary Molar Distalization—Two Case Reports
by Chenshuang Li and Chun-Hsi Chung
Appl. Sci. 2022, 12(2), 768; https://doi.org/10.3390/app12020768 - 13 Jan 2022
Cited by 3 | Viewed by 9131
Abstract
Maxillary molar distalization to correct a dental Class II molar relationship and to create space to relieve crowding has been a long-lasting subject of debate in orthodontics. Generally, to distalize maxillary molars, an intra-arch distalization appliance is favored over an inter-arch appliance since [...] Read more.
Maxillary molar distalization to correct a dental Class II molar relationship and to create space to relieve crowding has been a long-lasting subject of debate in orthodontics. Generally, to distalize maxillary molars, an intra-arch distalization appliance is favored over an inter-arch appliance since it does not utilize mandibular dentition as an anchorage, so some unwanted side effects on mandibular incisors can be avoided. A variety of intra-arch appliances have been developed to distalize maxillary molars, such as the pendulum, Jones jig, first class appliance, distal jet, and modified C-palatal plate. Although they could achieve efficient molar distalization, the learning curve of proper appliance insertion and activation is relatively long. In addition, the appliances are not comfortable for the patients due to the bulky activation units, especially when the activation units are designed in the palatal area. The current manuscript describes a novel and effective maxillary intra-arch molar distalization appliance—a modified Nance appliance technique, which consists of: (1) palatally, a big acrylic button against the palatal rugae and connected to the premolars with wide mesh pads; (2) buccally, regular brackets on maxillary premolars and first molars with sectional round stainless steel archwires and open coil springs between the second premolar and first molar. Either bilateral or unilateral maxillary molar distalization can be achieved with this appliance, and the Class II elastics are not needed. It is simple to be fabricated, delivered, and activated, and it is comfortable for patients. Full article
Show Figures

Figure 1

11 pages, 2046 KiB  
Article
Comparison of Intraoral and Extraoral Digital Scanners: Evaluation of Surface Topography and Precision
by Sang J. Lee, Soo-Woo Kim, Joshua J. Lee and Chan W. Cheong
Dent. J. 2020, 8(2), 52; https://doi.org/10.3390/dj8020052 - 20 May 2020
Cited by 41 | Viewed by 5746
Abstract
The aim of this study was to evaluate the surface topography and the precision measurements of different intraoral and extraoral digital scanners. A reference model of a maxillary arch with four implant analogs was prepared and scanned by three intraoral and two extraoral [...] Read more.
The aim of this study was to evaluate the surface topography and the precision measurements of different intraoral and extraoral digital scanners. A reference model of a maxillary arch with four implant analogs was prepared and scanned by three intraoral and two extraoral scanners. The reference model was scanned fifteen times with each digital scanning system, investigating the surface topography and precision measurements for the same-arch and cross-arch measurements. The data was exported to 3D inspection and mesh-processing software (GOM Inspect, Braunschweig, Germany). Statistical analysis was performed using a one-way Analysis of Variance (ANOVA) with the Tukey method for pairwise comparisons. The effect of parameters on generating the surface topography was analyzed by Univariate Linear Regression Analysis. Of the scanner systems evaluated, iTero (IT) exhibited the most number of triangulation points, followed by Trios 3 Shape (TR) and Straumann Cares (SC). There were no significant differences observed in the surface topography when comparing flat and contoured surfaces, the anterior and posterior position, and interproximal areas. For the precision measurement in the same quadrant, no statistical difference was noted between intra- and extraoral scanners. However, the extraoral scanners showed substantially higher precision measurements for the cross-arch measurement. Surface topography did not correlate to precision. Rather, precision correlated with the scanning mechanism. For a quadrant scanning, both intraoral and extraoral scanners are recommended, but extraoral scanners are recommended for a full-arch scanning. Full article
(This article belongs to the Special Issue Dental Ceramics and Metal-Free Materials in The Digital Workflow)
Show Figures

Figure 1

Back to TopTop