Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = implant-supported full-arch fixed dental prosthesis

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 1126 KiB  
Article
Psychosocial Impact of Maxilla-For-All® Treatment Using Standard and Long Implants (Pterygoid, Trans-Sinus and Zygomatic) on Patients with Severe Maxillary Atrophies: A 1-Year Prospective Study with PIDAQ-23 and OHIP-14
by Tommaso Grandi, Paolo Toti, Cesare Paoleschi, Matteo Giorgi, Ugo Covani and Giovanni Battista Menchini-Fabris
J. Clin. Med. 2025, 14(10), 3544; https://doi.org/10.3390/jcm14103544 - 19 May 2025
Viewed by 563
Abstract
Background/Objectives: The satisfaction of patients following maxillary full-arch rehabilitation is crucial in assessing treatment effectiveness. This one-year study evaluated patients’ satisfaction, quality of life, and aesthetic perception after receiving the Maxilla-for-All®/All-On-X treatments, which combine standard, pterygoid, trans-sinus, and zygomatic implants [...] Read more.
Background/Objectives: The satisfaction of patients following maxillary full-arch rehabilitation is crucial in assessing treatment effectiveness. This one-year study evaluated patients’ satisfaction, quality of life, and aesthetic perception after receiving the Maxilla-for-All®/All-On-X treatments, which combine standard, pterygoid, trans-sinus, and zygomatic implants to support a fixed prosthesis and offer a graftless solution that reduces morbidity and treatment time. Methods: A prospective cohort study using convenience sampling of subjects treated for severe maxillary atrophies was conducted on patients receiving immediate implant-supported full-arch fixed prostheses. The Oral Health Impact Profile (OHIP-14) and Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ-23) were administered preoperatively and one year post-treatment. Patients were grouped based on the presence or absence of complications (surgical, technical, and mechanical) and Wilcoxon tests were used for comparison (significance level = 0.05). Results: A total of 56 patients (29 female, 27 male) participated, with no implant or prosthesis failures. Eleven patients reported unilateral sinus membrane perforation, and seven had technical or mechanical complications. Preoperatively, 69% of patients rated their oral condition as unfavorable according to the OHIP-14; this dropped significantly to 21.8% post-treatment (p-value < 0.0001). After one year, the average PIDAQ-23 score improved significantly from 44.7 ± 16.6 to 6.8 ± 5.3 (p-value < 0.0001). No significant differences were observed between patients with or without complications (p-values ranging from 0.5270 to 0.8920). Conclusions: Full-arch rehabilitation using Maxilla-for-All®/All-On-X treatments significantly improved both aesthetic perception and chewing function in patients with severe maxillary atrophies. They reported a substantial reduction in oral health-related discomfort, as shown by a significant decrease in OHIP-14 scores one year post-treatment. Clinical or technical complications did not significantly impact patients’ quality-of-life outcomes or satisfaction, supporting the reliability of this treatment protocol. Full article
(This article belongs to the Special Issue Current Trends in Implant Dentistry)
Show Figures

Figure 1

19 pages, 330 KiB  
Review
Occlusion and Biomechanical Risk Factors in Implant-Supported Full-Arch Fixed Dental Prostheses—Narrative Review
by Andrea Berzaghi, Tiziano Testori, Riccardo Scaini and Sergio Bortolini
J. Pers. Med. 2025, 15(2), 65; https://doi.org/10.3390/jpm15020065 - 7 Feb 2025
Cited by 2 | Viewed by 4079
Abstract
The biophysiological differences between teeth and dental implants and the issue of occlusal overload, although controversial, form the basis for the management of occlusion in implant-supported full-arch fixed dental prostheses (ISFAFDPs). Although there is currently a lack of scientific evidence on occlusal management, [...] Read more.
The biophysiological differences between teeth and dental implants and the issue of occlusal overload, although controversial, form the basis for the management of occlusion in implant-supported full-arch fixed dental prostheses (ISFAFDPs). Although there is currently a lack of scientific evidence on occlusal management, it is clear that the favorable prognosis of ISFAFDPs is linked to a correct understanding of the biomechanical principles involved. In the design of ISFAFDPs, the lack of proprioceptive feedback requires special attention to biomechanical factors: minimizing overloading complications and providing biomechanical stability are among the main goals of the occlusion. In ISFAFDPs, the occlusion must be decided on the basis of several factors that influence the loads on prosthesis and implants: each case must be evaluated individually and requires a personalized occlusion. The main aim of this narrative review is to provide an overview of the occlusal principles and materials that can be used in ISFAFDPs based on the data currently available in the literature. Practical clinical recommendations for the occlusion management of ISFAFDPs and a biomechanical risk score index to personalize implant-prosthetic treatment are proposed. Full article
(This article belongs to the Special Issue Personalized Medicine in Dental and Oral Health)
7 pages, 3669 KiB  
Technical Note
Full-Arch, Implant-Fixed Complete Dentures in Monolithic Zirconia and Titanium: A Digital Workflow to Maximize Cost Effectiveness
by Gaetano Noè, Andrea Toffoli, Roberto Bonfiglioli, Guido Maria Macaluso and Edoardo Manfredi
Prosthesis 2022, 4(1), 73-79; https://doi.org/10.3390/prosthesis4010008 - 12 Feb 2022
Cited by 6 | Viewed by 5731
Abstract
Different techniques can be used to design and manufacture a full-arch, implant-supported prosthesis, and different materials can be chosen for its production, each with its advantages and limitations. One of the possibilities provided by digital tools is their ability to maintain low costs [...] Read more.
Different techniques can be used to design and manufacture a full-arch, implant-supported prosthesis, and different materials can be chosen for its production, each with its advantages and limitations. One of the possibilities provided by digital tools is their ability to maintain low costs to give more patients the chance to choose this commonly expensive treatment. The present work aims to present a protocol for the realization of full-arch, implant-fixed complete dentures (IFCDs) in monolithic zirconia and titanium. When the analogic master model is obtained, it is scanned to perform the digital wax-up, and the two parts of the prosthesis—a bar in titanium and an aesthetic component in monolithic zirconia—are milled. The dental team must then verify the precision of the milled components on the master model, so that they can be cemented together and delivered to the patient. This technique offers different advantages, in terms of cost sustainability, minimal wear risk for the prosthesis and its antagonists, and ease of re-intervening in the case of complications. The main limitations of the technique may lie in the aesthetic needs of the patient, because of the relatively poor aesthetic performance of monolithic zirconia and the absence of a pink orthopedic component. Full article
(This article belongs to the Section Prosthodontics)
Show Figures

Figure 1

8 pages, 629 KiB  
Article
A 5-Year Satisfaction Outcome Study of Patients Receiving Six-Implant-Supported Fixed Prosthesis
by Mazen A. Almasri
Clin. Pract. 2021, 11(4), 827-834; https://doi.org/10.3390/clinpract11040097 - 2 Nov 2021
Cited by 7 | Viewed by 3467
Abstract
The aim of the study was to analyze the satisfaction of patients treated with a protocol of six-implant-supported fixed prosthesis (6IFP) throughout 5 years of service. This retrospective study collected the data of all patients who had full-arch rehabilitations using 6IFP and followed [...] Read more.
The aim of the study was to analyze the satisfaction of patients treated with a protocol of six-implant-supported fixed prosthesis (6IFP) throughout 5 years of service. This retrospective study collected the data of all patients who had full-arch rehabilitations using 6IFP and followed them for 5 years. After applying the research inclusion/exclusion strategy, 37 cases were finally included in the study. All the patients had no previous complete dentures because they were partially edentulous, not interested in pursuing complete denture rehabilitation, had immediate dental extractions, implantation used the 2-stage protocol, and there was minor peri-implant socket grafting. Cases with severe bone loss that required extensive grafting were excluded. A total number of 222 implants were placed in the maxillary or mandibular arches in a total of 37 patients. The data presented the satisfaction outcomes concerning mastication, phonetics, and comfort during the first 5 years of the recall plan. The former was achieved based on the clinical record reviews, follow-up visits, and recall phone calls at the preoperative stage as well as annually thereafter. The mean satisfaction rate was 94.5%, with a mean record of 8.21 ± 1.7 out of 10, there was no gender predilection significance, and no age range variation significance was validated. Regarding the smoking status, the t-test score exhibited no significant effect on phonetics and mastication (p = 0.12, p = 0.16, respectively), whereas comfort was found to be significantly affected (p = 0.03). The comfort level was found to be slightly less at the immediate postoperative period among smokers when compared to non-smokers. In conclusion, partially edentulous patients who received the rehabilitation plan of arch dental extractions, six immediate implantations, and delayed prosthetic loading were found to be highly satisfied. Full article
Show Figures

Figure 1

12 pages, 3209 KiB  
Article
Two-Year Follow-Up of 4-mm-Long Implants Used as Distal Support of Full-Arch FDPs Compared to 10-mm Implants Installed after Sinus Floor Elevation. A Randomized Clinical Trial
by Fabio Rossi, Lorenzo Tuci, Lorenzo Ferraioli, Emanuele Ricci, Andreea Suerica, Daniele Botticelli, Gerardo Pellegrino and Pietro Felice
Int. J. Environ. Res. Public Health 2021, 18(7), 3846; https://doi.org/10.3390/ijerph18073846 - 6 Apr 2021
Cited by 4 | Viewed by 3233
Abstract
Background: In edentulous patients, bone resorption cannot allow the installation of standard implants and it is demanded to use short implants in the residual alveolar bone or longer implants in grafted bone. Aim: To compare the survival and bone level changes of standard [...] Read more.
Background: In edentulous patients, bone resorption cannot allow the installation of standard implants and it is demanded to use short implants in the residual alveolar bone or longer implants in grafted bone. Aim: To compare the survival and bone level changes of standard plus short 4-mm implants used as distal support of a maxillary full-arch fixed dental prostheses (FDPs) with standard (10-mm) implants placed in association with a bilateral sinus floor augmentation procedure. Material and Methods: Full-arch FDPs supported by six implants were randomly placed in both groups. In the control group, all implants were 10 mm long and 4.1 mm in diameter. The distal implant in both sides of the maxilla was installed after 4 months from bilaterally sinus floor elevation. In the test group (short group), the distal implant in both sides of the maxilla was 4 mm long and 4.1 mm in diameter. No sinus floor elevations were performed in the test group. Clinical assessments and X-rays were taken at prosthesis delivering and after 6, 12, 18, and 24 months. Patient-reported outcome measures (PROMs) were also evaluated before surgery and after 6, 12, and 24 months. Results: The changes over time of the bone level for the short implants were −0.01 ± 0.11 mm, −0.04 ± 0.13 mm, −0.17 ± 0.29 mm, and −0.28 ± 0.37 mm after 6, 12, 18, and 24 months from prosthesis delivering, respectively. For the standard implants, bone changes were −0.21 ± 0.33 mm (p = 0.103), −0.30 ± 0.32 mm (p = 0.023), −0.40 ± 0.37 mm (p = 0.144), and −0.54 ± 0.49 mm (p = 0.128), respectively. A statistically relevant difference was found only at 12 months after loading between the two groups. Conclusions: Similar results on implant survival rate and marginal bone loss were observed for the short and standard implants, placed in association with a bilateral sinus floor augmentation procedure, used as distal support of a maxillary full-arch FDP. A statistically relevant difference was found only at 12 months after loading between the two groups (p = 0.023). Full article
(This article belongs to the Special Issue Digital Dentistry, Implantology and Maxillo-Facial Diseases)
Show Figures

Figure 1

12 pages, 2851 KiB  
Article
The Influence of Custom-Milled Framework Design for an Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D-FEA Study
by João Paulo Mendes Tribst, Amanda Maria de Oliveira Dal Piva, Roberto Lo Giudice, Alexandre Luiz Souto Borges, Marco Antonio Bottino, Ettore Epifania and Pietro Ausiello
Int. J. Environ. Res. Public Health 2020, 17(11), 4040; https://doi.org/10.3390/ijerph17114040 - 5 Jun 2020
Cited by 48 | Viewed by 5102
Abstract
The current study aimed to evaluate the mechanical behavior of two different maxillary prosthetic rehabilitations according to the framework design using the Finite Element Analysis. An implant-supported full-arch fixed dental prosthesis was developed using a modeling software. Two conditions were modeled: a conventional [...] Read more.
The current study aimed to evaluate the mechanical behavior of two different maxillary prosthetic rehabilitations according to the framework design using the Finite Element Analysis. An implant-supported full-arch fixed dental prosthesis was developed using a modeling software. Two conditions were modeled: a conventional casted framework and an experimental prosthesis with customized milled framework. The geometries of bone, prostheses, implants and abutments were modeled. The mechanical properties and friction coefficient for each isotropic and homogeneous material were simulated. A load of 100 N load was applied on the external surface of the prosthesis at 30° and the results were analyzed in terms of von Mises stress, microstrains and displacements. In the experimental design, a decrease of prosthesis displacement, bone strain and stresses in the metallic structures was observed, except for the abutment screw that showed a stress increase of 19.01%. The conventional design exhibited the highest stress values located on the prosthesis framework (29.65 MPa) between the anterior implants, in comparison with the experimental design (13.27 MPa in the same region). An alternative design of a stronger framework with lower stress concentration was reported. The current study represents an important step in the design and analysis of implant-supported full-arch fixed dental prosthesis with limited occlusal vertical dimension. Full article
(This article belongs to the Special Issue Oral and Dental Health)
Show Figures

Figure 1

Back to TopTop