Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = hybrid generation system (HGS)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2400 KiB  
Article
Multilevel Middle Point Clamped (MMPC) Converter for DC Wind Power Applications
by Awais Karni, Omid Beik, Mahzad Gholamian, Mahdi Homaeinezhad and Muhammad Owais Manzoor
Sustainability 2024, 16(17), 7563; https://doi.org/10.3390/su16177563 - 1 Sep 2024
Cited by 1 | Viewed by 1648
Abstract
This manuscript introduces a novel multilevel middle point clamped (MMPC) DC-DC converter and its associated switching scheme aimed at maintaining the desired medium-voltage DC (MVDC) collector grid within offshore all-DC wind farms. Building upon previous work by the authors, which proposed an all-DC [...] Read more.
This manuscript introduces a novel multilevel middle point clamped (MMPC) DC-DC converter and its associated switching scheme aimed at maintaining the desired medium-voltage DC (MVDC) collector grid within offshore all-DC wind farms. Building upon previous work by the authors, which proposed an all-DC structure serving as a benchmark system, this study explores the application of the MMPC DC-DC converter within this framework. Within the all-DC wind generation system, a 9-phase hybrid generator (HG) integrated into the wind turbine is linked to the MVDC collector grid through an AC-DC stage, which is a passive rectifier. This passive rectifier offers elevated voltage ratings and protection against back power flow. The conventional neutral point clamped (NPC) converter concept has been thoroughly investigated and expanded upon to develop the proposed MMPC DC-DC converter. The proposed MMPC DC-DC converter integrates boosting capabilities, facilitating the connection of the generator’s rectified voltage to the MVDC collector grid while regulating variable rectified voltage to a fixed MVDC collector grid voltage. The MVDC collector grid is further interconnected with high-voltage DC (HVDC) through a DC-DC converter situated in an offshore substation. This paper further provides a comprehensive overview of the proposed MMPC DC-DC converter, detailing its operational modes and corresponding switching schemes. Through an in-depth examination of operational modes, duty cycles for each switch and mode are defined, subsequently establishing the relationship between rectified input voltage and MVDC output voltage for the MMPC DC-DC converter. Utilizing the middle point clamped architecture, this innovative converter offers several advantages, including low ripple voltage, a modular structure, and reduced switching stress because of the multilevel voltage and the incorporation of a hard point, which also facilitates the capacitor voltage balancing. Finally, the effectiveness of the proposed converter is evaluated via simulation studies of a wind turbine conversion system utilizing two cascaded MMPC DC-DC converters operating under variable input voltage conditions. The simulations confirm its efficacy, supported by promising results, and validating its performance. Full article
(This article belongs to the Section Energy Sustainability)
Show Figures

Figure 1

18 pages, 2707 KiB  
Article
Operational Robustness Assessment of the Hydro-Based Hybrid Generation System under Deep Uncertainties
by Jianhua Jiang, Bo Ming, Qiang Huang and Qingjun Bai
Energies 2024, 17(8), 1974; https://doi.org/10.3390/en17081974 - 22 Apr 2024
Cited by 1 | Viewed by 1136
Abstract
The renewable-dominant hybrid generation systems (HGSs) are increasingly important to the electric power system worldwide. However, influenced by uncertain meteorological factors, the operational robustness of HGSs must be evaluated to inform the associated decision-making. Additionally, the main factors affecting the HGS’s robustness should [...] Read more.
The renewable-dominant hybrid generation systems (HGSs) are increasingly important to the electric power system worldwide. However, influenced by uncertain meteorological factors, the operational robustness of HGSs must be evaluated to inform the associated decision-making. Additionally, the main factors affecting the HGS’s robustness should be urgently identified under deep uncertainties, as this provides valuable guidance for HGS capacity configuration. In this paper, a multivariate stochastic simulation method is developed and used to generate uncertain resource scenarios of runoff, photovoltaic power, and wind power. Subsequently, a long-term stochastic optimization model of the HGS is employed to derive the optimal operating rules. Finally, these operating rules are used to simulate the long-term operation of an HGS, and the results are used to evaluate the HGS’s robustness and identify its main sensitivities. A clean energy base located in the Upper Yellow River Basin, China, is selected as a case study. The results show that the HGS achieves greater operational robustness than an individual hydropower system, and the robustness becomes weaker as the total capacity of photovoltaic and wind power increases. Additionally, the operational robustness of the HGS is found to be more sensitive to the total capacity than to the capacity ratio between photovoltaic and wind power. Full article
Show Figures

Figure 1

29 pages, 6357 KiB  
Article
Energetic, Economic and Environmental (3E) Analysis of a RES-Waste Gasification Plant with Syngas Storage Cooperation
by Jacek Roman, Robert Wróblewski, Beata Klojzy-Karczmarczyk and Bartosz Ceran
Energies 2023, 16(4), 2062; https://doi.org/10.3390/en16042062 - 20 Feb 2023
Cited by 4 | Viewed by 2516
Abstract
Today, the increasing amount of waste is a growing ecological and financial problem. Another issue is the need to limit the share of controllable sources powered by fossil fuels. A hybrid generation system (HGS) is proposed to solve both problems. The system consists [...] Read more.
Today, the increasing amount of waste is a growing ecological and financial problem. Another issue is the need to limit the share of controllable sources powered by fossil fuels. A hybrid generation system (HGS) is proposed to solve both problems. The system consists of renewable energy sources (RES) and a waste gasification system. Contrary to many papers, it is proposed to include syngas storage and use gas turbines as balancing sources. The HGS was modeled, and electricity generation, capacity factors, and efficiencies were calculated. The economic (LCOE and PP) and environmental parameters (CO2 emission and reduction) were analyzed and calculated for different RES capacities. The results show that the proposed HGS covered 45.7–80% of municipal demand. The HGS was characterized by high CO2 emissions, due to the low efficiency of gasification-gas turbine installation and the need to compress syngas. However, the HGS can be environmentally beneficial due to the reduction in waste disposal in landfills. The LCOE was EUR 174–191 with a minimum at the RES capacity of 14 MW. Any change in waste disposal costs and emission allowances would cause significant changes in the LCOE. It was found that it can be beneficial to use a gasification system as a balancing source in a HGS. Full article
Show Figures

Figure 1

20 pages, 3850 KiB  
Article
Incorporation of PEG Diacrylates (PEGDA) Generates Hybrid Fmoc-FF Hydrogel Matrices
by Elisabetta Rosa, Enrico Gallo, Teresa Sibillano, Cinzia Giannini, Serena Rizzuti, Eliana Gianolio, Pasqualina Liana Scognamiglio, Giancarlo Morelli, Antonella Accardo and Carlo Diaferia
Gels 2022, 8(12), 831; https://doi.org/10.3390/gels8120831 - 16 Dec 2022
Cited by 15 | Viewed by 4291
Abstract
Generated by a hierarchical and multiscale self-assembling phenomenon, peptide-based hydrogels (HGs) are soft materials useful for a variety of applications. Short and ultra-short peptides are intriguing building blocks for hydrogel fabrication. These matrices can also be obtained by mixing low-molecular-weight peptides with other [...] Read more.
Generated by a hierarchical and multiscale self-assembling phenomenon, peptide-based hydrogels (HGs) are soft materials useful for a variety of applications. Short and ultra-short peptides are intriguing building blocks for hydrogel fabrication. These matrices can also be obtained by mixing low-molecular-weight peptides with other chemical entities (e.g., polymers, other peptides). The combination of two or more constituents opens the door to the development of hybrid systems with tunable mechanical properties and unexpected biofunctionalities or morphologies. For this scope, the formulation, the multiscale analysis, and the supramolecular characterization of novel hybrid peptide-polymer hydrogels are herein described. The proposed matrices contain the Fmoc-FF (Nα-fluorenylmethyloxycarbonyl diphenylalanine) hydrogelator at a concentration of 0.5 wt% (5.0 mg/mL) and a diacrylate α-/ω-substituted polyethylene-glycol derivative (PEGDA). Two PEGDA derivatives, PEGDA 1 and PEGDA2 (mean molecular weights of 575 and 250 Da, respectively), are mixed with Fmoc-FF at different ratios (Fmoc-FF/PEGDA at 1/1, 1/2, 1/5, 1/10 mol/mol). All the multicomponent hybrid peptide-polymer hydrogels are scrutinized with a large panel of analytical techniques (including proton relaxometry, FTIR, WAXS, rheometry, and scanning electronic microscopy). The matrices were found to be able to generate mechanical responses in the 2–8 kPa range, producing a panel of tunable materials with the same chemical composition. The release of a model drug (Naphthol Yellow S) is reported too. The tunable features, the different topologies, and the versatility of the proposed materials open the door to the development of tools for different applicative areas, including diagnostics, liquid biopsies and responsive materials. The incorporation of a diacrylate function also suggests the possible development of interpenetrating networks upon cross-linking reactions. All the collected data allow a mutual comparison between the different matrices, thus confirming the significance of the hybrid peptide/polymer-based methodology as a strategy for the design of innovative materials. Full article
(This article belongs to the Special Issue Synthesis and Applications of Hydrogels)
Show Figures

Figure 1

18 pages, 2470 KiB  
Article
Bi-level Capacity Planning of Wind-PV-Battery Hybrid Generation System Considering Return on Investment
by Bowen Yang, Yougui Guo, Xi Xiao and Peigen Tian
Energies 2020, 13(12), 3046; https://doi.org/10.3390/en13123046 - 12 Jun 2020
Cited by 15 | Viewed by 2477
Abstract
Reasonable configuration of equipment capacity can effectively improve the economics of wind-photovoltaic-battery hybrid generation system (WPB-HGS). Based on the current needs of investors to pay more attention to the economic benefits of WPB-HGS, this paper proposes a capacity configuration method for WPB-HGS considering [...] Read more.
Reasonable configuration of equipment capacity can effectively improve the economics of wind-photovoltaic-battery hybrid generation system (WPB-HGS). Based on the current needs of investors to pay more attention to the economic benefits of WPB-HGS, this paper proposes a capacity configuration method for WPB-HGS considering return on investment (ROI). A bi-level planning model for integrated planning and operation of WPB-HGS was established. The lower-level model optimizes the system’s operating status with the goal of maximizing the daily power sales of the system. The upper-level model plans the equipment capacity of the WPB-HGS with the goal of maximizing the annual net income and return on investment. The model is solved using adaptive weighted particle swarm optimization. According to actual engineering examples, the specific equipment capacity is configured, and the configuration results are analyzed to verify the effectiveness of the method. Full article
(This article belongs to the Special Issue Modeling and Control of Smart Energy Systems)
Show Figures

Graphical abstract

18 pages, 2287 KiB  
Article
Gelatin Nanoparticles-HPMC Hybrid System for Effective Ocular Topical Administration of Antihypertensive Agents
by Sergio Esteban-Pérez, Vanessa Andrés-Guerrero, José Javier López-Cano, Irene Molina-Martínez, Rocio Herrero-Vanrell and Irene Bravo-Osuna
Pharmaceutics 2020, 12(4), 306; https://doi.org/10.3390/pharmaceutics12040306 - 28 Mar 2020
Cited by 35 | Viewed by 4883
Abstract
The increment in ocular drug bioavailability after topical administration is one of the main challenges in pharmaceutical technology. For several years, different strategies based on nanotechnology, hydrogels or implants have been evaluated. Nowadays, the tolerance of ophthalmic preparations has become a critical issue [...] Read more.
The increment in ocular drug bioavailability after topical administration is one of the main challenges in pharmaceutical technology. For several years, different strategies based on nanotechnology, hydrogels or implants have been evaluated. Nowadays, the tolerance of ophthalmic preparations has become a critical issue and it is essential to the use of well tolerated excipients. In the present work, we have explored the potential of gelatin nanoparticles (GNPs) loaded with timolol maleate (TM), a beta-adrenergic blocker widely used in the clinic for glaucoma treatment and a hybrid system of TM-GNPs included in a hydroxypropyl methylcellulose (HPMC) viscous solution. The TM- loaded nanoparticles (mean particle size of 193 ± 20 nm and drug loading of 0.291 ± 0.019 mg TM/mg GNPs) were well tolerated both in vitro (human corneal cells) and in vivo. The in vivo efficacy studies performed in normotensive rabbits demonstrated that these gelatin nanoparticles were able to achieve the same hypotensive effect as a marketed formulation (0.5% TM) containing a 5-fold lower concentration of the drug. When comparing commercial and TM-GNPs formulations with the same TM dose, nanoparticles generated an increased efficacy with a significant (p < 0.05) reduction of intraocular pressure (IOP) (from 21% to 30%) and an augmentation of 1.7-fold in the area under the curve (AUC)(0–12h). On the other hand, the combination of timolol-loaded nanoparticles (TM 0.1%) and the viscous polymer HPMC 0.3%, statistically improved the IOP reduction up to 30% (4.65 mmHg) accompanied by a faster time of maximum effect (tmax = 1 h). Furthermore, the hypotensive effect was extended for four additional hours, reaching a pharmacological activity that lasted 12 h after a single instillation of this combination, and leading to an AUC(0–12h) 2.5-fold higher than the one observed for the marketed formulation. According to the data presented in this work, the use of hybrid systems that combine well tolerated gelatin nanoparticles and a viscous agent could be a promising alternative in the management of high intraocular pressure in glaucoma. Full article
(This article belongs to the Special Issue Ocular Drug Delivery: Present Innovations and Future Challenges)
Show Figures

Graphical abstract

20 pages, 3225 KiB  
Article
Development of an Optimal Power Control Scheme for Wave-Offshore Hybrid Generation Systems
by Seungmin Jung and Gilsoo Jang
Energies 2015, 8(9), 9009-9028; https://doi.org/10.3390/en8099009 - 25 Aug 2015
Cited by 6 | Viewed by 4624
Abstract
Integration technology of various distribution systems for improving renewable energy utilization has been receiving attention in the power system industry. The wave-offshore hybrid generation system (HGS), which has a capacity of over 10 MW, was recently developed by adopting several voltage source converters [...] Read more.
Integration technology of various distribution systems for improving renewable energy utilization has been receiving attention in the power system industry. The wave-offshore hybrid generation system (HGS), which has a capacity of over 10 MW, was recently developed by adopting several voltage source converters (VSC), while a control method for adopted power conversion systems has not yet been configured in spite of the unique system characteristics of the designated structure. This paper deals with a reactive power assignment method for the developed hybrid system to improve the power transfer efficiency of the entire system. Through the development and application processes for an optimization algorithm utilizing the real-time active power profiles of each generator, a feasibility confirmation of power transmission loss reduction was implemented. To find the practical effect of the proposed control scheme, the real system information regarding the demonstration process was applied from case studies. Also, an evaluation for the loss of the improvement rate was calculated. Full article
(This article belongs to the Special Issue Control of Energy Storage)
Show Figures

Graphical abstract

Back to TopTop