Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = foulant identification

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 5800 KiB  
Article
Production of Anthocyanin-Enriched Juices by Electrodialysis with Filtration Membrane Process: The Influence of Duration on Juice Composition, Process Efficiency, and Membrane Fouling
by Eva Revellat and Laurent Bazinet
Foods 2024, 13(21), 3478; https://doi.org/10.3390/foods13213478 - 30 Oct 2024
Viewed by 998
Abstract
The Electrodialysis with Filtration Membrane (EDFM) system has shown promise in juice enrichment, but further optimization is needed. This study evaluated the effect of processing duration (3 and 6 h) on juice composition, process efficiency, and membrane fouling. Results demonstrated a significant impact [...] Read more.
The Electrodialysis with Filtration Membrane (EDFM) system has shown promise in juice enrichment, but further optimization is needed. This study evaluated the effect of processing duration (3 and 6 h) on juice composition, process efficiency, and membrane fouling. Results demonstrated a significant impact of processing time on juice composition, especially anthocyanin and mineral content. Two anthocyanin-depleted juices (−18.94% and −30.70%) and two anthocyanin-enriched juices (26.21% and 44.21%) were produced. Similar energy (1512.13 Wh/g of anthocyanins) was required to migrate equivalent amounts of anthocyanins over both time periods, with no impediment due to fouling observed, although the system’s resistance increased (2.5-fold after 3 h, 3.2-fold after 6 h). Membrane fouling was characterized through conductivity, thickness, ATR-FTIR, SEM-EDX, and foulant identification. Minimal anthocyanin accumulation occurred on cation-exchange membranes (CEM), while anthocyanins and PACs concentrated within the filtering layer of filtration membranes (FM). However, fouling did not increase with longer processing. Structural alterations were noted in anion-exchange membranes (AEMs), suggesting instability under high electric fields. Overall, EDFM effectively enriched cranberry juice with anthocyanins, but further research is necessary to address AEM degradation under limiting current density conditions. Full article
(This article belongs to the Special Issue Membranes for Innovative Bio-Food Processing)
Show Figures

Figure 1

16 pages, 4958 KiB  
Article
Autopsy of Used Reverse Osmosis Membranes from the Largest Seawater Desalination Plant in Oman
by Mohammed Al-Abri, Htet Htet Kyaw, Buthayna Al-Ghafri, Myo Tay Zar Myint and Sergey Dobretsov
Membranes 2022, 12(7), 671; https://doi.org/10.3390/membranes12070671 - 28 Jun 2022
Cited by 13 | Viewed by 4013
Abstract
The Barka desalination plant, commissioned in 2018, is the largest desalination plant in Oman. It has a capacity of 281 MLD with a reverse osmosis (RO) first-pass recovery rate of 46%. As part of the standard operator practice, a membrane autopsy was conducted [...] Read more.
The Barka desalination plant, commissioned in 2018, is the largest desalination plant in Oman. It has a capacity of 281 MLD with a reverse osmosis (RO) first-pass recovery rate of 46%. As part of the standard operator practice, a membrane autopsy was conducted to determine the cause of reductions in membrane performance. This study investigated fouled membranes (model No. SW30HRLE-440) from two different locations in the membrane rack. Various analytical methods were used to conduct the membrane autopsy. Field-emission scanning electron microscopy/energy-dispersive X-ray (FESEM/EDS) analyses of membrane samples showed major components of inorganic foulants. Moreover, black and salt-like crystals deposited on the membrane surface revealed significant carbon (C) components and oxygen (O), with a small amount of magnesium (Mg), chloride (Cl), sodium (Na), aluminium (Al), and calcium (Ca), respectively. A Fourier transform infrared (FTIR) analysis revealed the presence of long-chain hydrocarbons, carboxylic acids/esters, carbohydrates/polysaccharides, and inorganic foulants. Thermogravimetric analyses (TGA) of the membranes showed a high initial weight loss due to organic and inorganic fouling. X-ray photoelectron (XPS) analyses further confirmed the presence of inorganic and organic foulants on the membrane surfaces. Bacteria identification results showed the presence of Bacillus cereus and Bacillus marisflavi. This paper offers a detailed analysis of the foulants present on the reverse osmosis membrane surface and sub-surface before and after a cleaning process. Full article
(This article belongs to the Section Membrane Analysis and Characterization)
Show Figures

Figure 1

20 pages, 6021 KiB  
Article
Foulant Identification and Performance Evaluation of Antiscalants in Increasing the Recovery of a Reverse Osmosis System Treating Anaerobic Groundwater
by Muhammad Nasir Mangal, Sergio G. Salinas-Rodriguez, Jos Dusseldorp, Bastiaan Blankert, Victor A. Yangali-Quintanilla, Antoine J. B. Kemperman, Jan C. Schippers, Walter G. J. van der Meer and Maria D. Kennedy
Membranes 2022, 12(3), 290; https://doi.org/10.3390/membranes12030290 - 2 Mar 2022
Cited by 8 | Viewed by 4970
Abstract
The objectives of this study are to assess the performance of antiscalants in increasing the recovery (≥85%) of a reverse osmosis (RO) plant treating anaerobic groundwater (GW) in Kamerik (the Netherlands), and to identify scalants/foulant that may limit RO recovery. Five different commercially [...] Read more.
The objectives of this study are to assess the performance of antiscalants in increasing the recovery (≥85%) of a reverse osmosis (RO) plant treating anaerobic groundwater (GW) in Kamerik (the Netherlands), and to identify scalants/foulant that may limit RO recovery. Five different commercially available antiscalants were compared on the basis of their manufacturer-recommended dose. Their ability to increase the recovery from 80% to a target of 85% was evaluated in pilot-scale measurements with anaerobic GW and in once-through lab-scale RO tests with synthetic (artificial) feedwater. A membrane autopsy was performed on the tail element(s) with decreased permeability. X-ray photoelectron spectroscopy (XPS) analysis indicated that calcium phosphate was the primary scalant causing permeability decline at 85% recovery and limiting RO recovery. The addition of antiscalant had no positive effect on RO operation and scaling prevention, since at 85% recovery, permeability of the last stage decreased with all five antiscalants, while no decrease in permeability was observed without the addition of antiscalant at 80% recovery. In addition, in lab-scale RO tests executed with synthetic feed water containing identical calcium and phosphate concentrations as the anaerobic GW, calcium phosphate scaling occurred both with and without antiscalant at 85% recovery, while at 80% recovery without antiscalant, calcium phosphate did not precipitate in the RO element. In brief, calcium phosphate appeared to be the main scalant limiting RO recovery, and antiscalants were unable to prevent calcium phosphate scaling or to achieve a recovery of 85% or higher. Full article
Show Figures

Figure 1

37 pages, 32302 KiB  
Review
A Review on Ion-Exchange Membrane Fouling during the Electrodialysis Process in the Food Industry, Part 1: Types, Effects, Characterization Methods, Fouling Mechanisms and Interactions
by Lasâad Dammak, Julie Fouilloux, Myriam Bdiri, Christian Larchet, Estelle Renard, Lassaad Baklouti, Veronika Sarapulova, Anton Kozmai and Natalia Pismenskaya
Membranes 2021, 11(10), 789; https://doi.org/10.3390/membranes11100789 - 16 Oct 2021
Cited by 56 | Viewed by 8032
Abstract
Electrodialysis (ED) was first established for water desalination and is still highly recommended in this field for its high water recovery, long lifetime and acceptable electricity consumption. Today, thanks to technological progress in ED processes and the emergence of new ion-exchange membranes (IEMs), [...] Read more.
Electrodialysis (ED) was first established for water desalination and is still highly recommended in this field for its high water recovery, long lifetime and acceptable electricity consumption. Today, thanks to technological progress in ED processes and the emergence of new ion-exchange membranes (IEMs), ED has been extended to many other applications in the food industry. This expansion of uses has also generated several problems such as IEMs’ lifetime limitation due to different ageing phenomena (because of organic and/or mineral compounds). The current commercial IEMs show excellent performance in ED processes; however, organic foulants such as proteins, surfactants, polyphenols or other natural organic matters can adhere on their surface (especially when using anion-exchange membranes: AEMs) forming a colloid layer or can infiltrate the membrane matrix, which leads to the increase in electrical resistance, resulting in higher energy consumption, lower water recovery, loss of membrane permselectivity and current efficiency as well as lifetime limitation. If these aspects are not sufficiently controlled and mastered, the use and the efficiency of ED processes will be limited since, it will no longer be competitive or profitable compared to other separation methods. In this work we reviewed a significant amount of recent scientific publications, research and reviews studying the phenomena of IEM fouling during the ED process in food industry with a special focus on the last decade. We first classified the different types of fouling according to the most commonly used classifications. Then, the fouling effects, the characterization methods and techniques as well as the different fouling mechanisms and interactions as well as their influence on IEM matrix and fixed groups were presented, analyzed, discussed and illustrated. Full article
(This article belongs to the Special Issue In-Depth on the Fouling and Antifouling of Ion-Exchange Membranes)
Show Figures

Figure 1

24 pages, 7166 KiB  
Article
Identification of Foulants on Polyethersulfone Membranes Used to Remove Colloids and Dissolved Matter from Paper Mill Treated Effluent
by Mayko Rannany S. Sousa, Jaime Lora-García, María-Fernanda López-Pérez and Marc Heran
Water 2020, 12(2), 365; https://doi.org/10.3390/w12020365 - 29 Jan 2020
Cited by 9 | Viewed by 3851
Abstract
In this study, membrane fouling caused by paperboard mill treated effluent (PMTE) was investigated based on a dead-end ultrafiltration (UF) pilot-scale study. The membranes employed were commercial hydrophobic UF membranes made of polyethersulfone (PES) with a molecular weight cut-off of 10 kDa, 50 [...] Read more.
In this study, membrane fouling caused by paperboard mill treated effluent (PMTE) was investigated based on a dead-end ultrafiltration (UF) pilot-scale study. The membranes employed were commercial hydrophobic UF membranes made of polyethersulfone (PES) with a molecular weight cut-off of 10 kDa, 50 kDa, and 100 kDa. Membrane fouling mechanism during dead-end filtration, chemical analysis, field emission scanning electron microscopy (FESEM), energy-dispersive spectrophotometry (EDS), attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy and 3D fluorescence excitation–emission matrix (3DEEM) analysis were applied to understand which fraction of the dissolved and colloidal substances (DCS) caused the membrane fouling. The results indicated that the phenomenon controlling fouling mechanism tended to be cake layer formation (R2 ≥ 0.98) for all membranes tested. The 3DEEM results indicate that the majority of the organic foulants with fluorescence characteristics on the membrane were colloidal proteins (protein-like substances I+II) and macromolecular proteins (soluble microbial products, SMP-like substances). In addition, polysaccharide (cellulosic species), fatty and resin acid substances were identified on the fouled membrane by the ATR–FTIR analysis and play an important role in membrane fouling. In addition, the FESEM and EDS analyses indicate that the presence of inorganic foulants on the membrane surfaces, such as metal ions and especially Ca2+, can accelerate membrane fouling, whereas Mg and Si are linked to reversible fouling. Full article
(This article belongs to the Special Issue Membrane Technologies and Water Treatment)
Show Figures

Figure 1

Back to TopTop