Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = fire fatalities and serious incidents

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 2653 KB  
Article
The Fire Behaviour of Fabrics Containing Dried Emollient Residues
by Roísín McDermott, Mya Richards, Megan-Mae Wright, George Shajan, Joanne Morrissey and Sarah Hall
Fire 2025, 8(4), 133; https://doi.org/10.3390/fire8040133 - 29 Mar 2025
Cited by 1 | Viewed by 3464
Abstract
A significant number of UK fire fatalities have been reported to involve textiles contaminated with emollients. In the following study, the flammability of a variety of fabrics containing 14 different emollients, including paraffin-free creams, was evaluated. This is the first time the impact [...] Read more.
A significant number of UK fire fatalities have been reported to involve textiles contaminated with emollients. In the following study, the flammability of a variety of fabrics containing 14 different emollients, including paraffin-free creams, was evaluated. This is the first time the impact of the presence of such a large range of emollients has been examined. Horizontal burn tests were conducted on emollient-contaminated fabrics. Significantly earlier ignition time were noted upon heating for all emollient-contaminated fabrics (p < 0.001) when compared to the behaviour of blank fabrics were noted using a vertical burn test. The mean time to ignition for 100% cotton fabric (151 ± 2 g/m2) was reduced from 71.5 to 14.4 s and for 52%/48% polyester/cotton fabric (103 ± 2 g/m2) from 328 to 12.9 s by the presence of emollients. Horizontal burn tests with a direct flame on 100% cotton fabric (114 ± 1 g/m2) displayed an accelerated mean flame speed from 0.0032 to 0.0048 ms−1 and an increased maximum flame height of 56.6 to 175.4 mm for emollient-contaminated fabrics. These findings demonstrate the fire risk of fabrics contaminated with a dried emollient. Their potential to ignite quickly and to propagate a fire may strongly decrease the reaction time of an impacted individual. Therefore, it is important that this risk and appropriate safety advice be continually highlighted and communicated not only in the UK but worldwide. Full article
(This article belongs to the Special Issue Fire Detection and Public Safety, 2nd Edition)
Show Figures

Figure 1

21 pages, 578 KB  
Article
Exploring ISO31000 Risk Management during Dynamic Fire and Emergency Operations in Western Australia
by Greg Penney
Fire 2019, 2(2), 21; https://doi.org/10.3390/fire2020021 - 24 Apr 2019
Cited by 12 | Viewed by 9240
Abstract
Firefighting remains an inherently dangerous occupation with serious injuries and fatalities reported globally. The Australasian Fire Authorities Council adopt ISO31000 as the standard of risk management for all firefighting and mitigation operations. However, previous studies have reported that decisions made by incident controllers [...] Read more.
Firefighting remains an inherently dangerous occupation with serious injuries and fatalities reported globally. The Australasian Fire Authorities Council adopt ISO31000 as the standard of risk management for all firefighting and mitigation operations. However, previous studies have reported that decisions made by incident controllers during dynamic emergencies are typically reactionary and only partially compliant with the ISO31000 process. This paper describes research using new qualitative and quantitative data that support incident controllers in managing risk during dynamic fire and emergency situations, in accordance with ISO31000. The research was completed through two studies. The first study explored risk attitudes of serving fire service officers through semistructured interviews and in-depth structured surveys. The second study identified the severity of firefighting consequences and likelihood through analysis of Western Australian fire service safety and incident reports between January 1st, 2001 and January 1st, 2015. The overall and conditional probability of specific injuries during the various tasks undertaken during emergency incidents was calculated using Bayesian statistical analysis. The findings indicate that whilst current practices are arguably effective in preventing worst case consequences being realised, improvements in operational risk management can be made in accordance with ISO31000 during emergencies and in pre-incident planning. Full article
Show Figures

Figure 1

24 pages, 4339 KB  
Article
Recent Health and Safety Incident Trends Related to the Storage of Woody Biomass: A Need for Improved Monitoring Strategies
by Sally Krigstin, Suzanne Wetzel, Nivatha Jayabala, Christopher Helmeste, Sebnem Madrali, Joy Agnew and Sylvain Volpe
Forests 2018, 9(9), 538; https://doi.org/10.3390/f9090538 - 1 Sep 2018
Cited by 39 | Viewed by 7803
Abstract
Self-heating fires, dust explosions and off-gassing during biomass storage are serious hazards which can have devastating consequences, resulting in worker fatalities and health impacts, as well as bioenergy plant destruction and complete loss of production. A compilation of incident reports involving biomass storage [...] Read more.
Self-heating fires, dust explosions and off-gassing during biomass storage are serious hazards which can have devastating consequences, resulting in worker fatalities and health impacts, as well as bioenergy plant destruction and complete loss of production. A compilation of incident reports involving biomass storage from 2000–2018 has revealed that these potential hazards continue to be a major concern in the bioenergy sector. Higher occurrence rates were found for incidents categorized as self-heating fires and fires of uncertain causes in recent years through our study of online reports. This paper highlights a critical need for improved safety protocols for bioenergy plant workers, detailed incident documentation and enhanced biomass monitoring strategies to drastically reduce the occurrence of threats associated with the storage of woody biomass. In order to manage the high risks associated with self-heating, a system for real-time monitoring of internal pile temperature was investigated. A monitoring system supplied by Braingrid Corporation was verified using embedded Tinytag thermologgers indicating that this methodology shows potential for preventing spontaneous combustion events by providing real time temperature data for superior pile management. Full article
(This article belongs to the Special Issue Forest Bioenergy and Bioproducts)
Show Figures

Figure 1

Back to TopTop