Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = fault ride through (FRT) circuitry

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
33 pages, 7898 KB  
Review
Fault Ride-Through Operation Analysis of Doubly Fed Induction Generator-Based Wind Energy Conversion Systems: A Comparative Review
by Aftab Ahmed Ansari and Giribabu Dyanamina
Energies 2022, 15(21), 8026; https://doi.org/10.3390/en15218026 - 28 Oct 2022
Cited by 34 | Viewed by 5394
Abstract
In present electrical power systems, wind energy conversion systems based on doubly fed induction generators represent one of the most commonly accepted systems in the global market due to their excellent performance under different power system operations. The high wind energy penetration rate [...] Read more.
In present electrical power systems, wind energy conversion systems based on doubly fed induction generators represent one of the most commonly accepted systems in the global market due to their excellent performance under different power system operations. The high wind energy penetration rate makes it challenging for these wind turbines to follow grid code requirements. All operations of a wind energy system during a dip in voltage require special attention; these operations are critically known as fault ride-through and low voltage ride-through. In this paper, various fault ride-through techniques of doubly fed induction generator-based wind energy conversion systems, such as protective circuitry, reactive power injection, and control methods for transient and steady state operations, have been presented to improve the performance. During system disturbances, protective circuitry or control mechanisms are typically used to limit the over-current of the rotor and the generated inappropriate DC link over-voltage. Simultaneously, the reactive power injection system overcomes the reactive power scarcity and enhances the transient response, further limiting the DC bus voltage and rotor current. This review paper compares and suggests appropriate FRT methods that are driven by external modifications and internal system improvements. Furthermore, typical case studies are discussed to illustrate and support the FRT system. The impact of each case study was evaluated and analyzed using the results obtained from the MATLAB/Simulink application and the OPAL-RT (OP4500) real time simulator (RTS). Full article
(This article belongs to the Topic Repowering of Wind Farms)
Show Figures

Figure 1

19 pages, 5259 KB  
Article
Design and Implementation of Novel Fault Ride through Circuitry and Control for Grid-Connected PV System
by Donghwi Kim, Umar Fitra Ramadhan, Saif Ul Islam, Seungmin Jung and Minhan Yoon
Sustainability 2022, 14(15), 9736; https://doi.org/10.3390/su14159736 - 8 Aug 2022
Cited by 9 | Viewed by 3410
Abstract
This paper provides a comparison of a designed method of a fault ride through (FRT) circuit, i.e., switch-type fault current limiter (STFCL) and bridge-type fault current limiter (BFCL), to optimize the electrical parameters of grid-connected solar systems (PVSs) under asymmetric single line-to-ground fault [...] Read more.
This paper provides a comparison of a designed method of a fault ride through (FRT) circuit, i.e., switch-type fault current limiter (STFCL) and bridge-type fault current limiter (BFCL), to optimize the electrical parameters of grid-connected solar systems (PVSs) under asymmetric single line-to-ground fault and symmetric three-phase fault. The main differences between switch- and bridge-type fault current limiters is the electric component devices such as the bridge rectifier, snubber capacitor, energy absorption bypass and current-limiting inductors. In addition, the designed FRT performance with the inverter control are analyzed in-depth, e.g., a well-adjusted proportional integral (PI) and proposed steepest descent (SD) controller are compared in the fault condition. To compare the proposed method with the conventional method, the AC power and voltage on a common coupling point (PCC) and DC link voltage of the PV system are analyzed with a MATLAB/Simulink model of a 100 kW three-phase grid-connected photovoltaic system. The simulation results of the proposed FRT circuit and SD controller verify the stability improvement and vibration-free and fast and robust responses of electrical parameters on both PV grid sides during asymmetric disturbances. Full article
(This article belongs to the Special Issue Renewable Energy: Technologies and Challenges)
Show Figures

Figure 1

26 pages, 14233 KB  
Article
Design of Robust Fuzzy Logic Controller Based on the Levenberg Marquardt Algorithm and Fault Ride Trough Strategies for a Grid-Connected PV System
by Saif Ul Islam, Kamran Zeb, Waqar Ud Din, Imran Khan, Muhammad Ishfaq, Altaf Hussain, Tiago Davi Curi Busarello and Hee Je Kim
Electronics 2019, 8(4), 429; https://doi.org/10.3390/electronics8040429 - 12 Apr 2019
Cited by 19 | Viewed by 5246
Abstract
This paper emphasizes the design and investigation of a new optimization scheme for a grid-connected photovoltaic system (PVS) under unbalance faults. The proposed scheme includes fuzzy logic controller (FLC) based on the Levenberg–Marquardt (LM) optimization technique in coordination with bridge-type-fault-current limiter (BFCL) as [...] Read more.
This paper emphasizes the design and investigation of a new optimization scheme for a grid-connected photovoltaic system (PVS) under unbalance faults. The proposed scheme includes fuzzy logic controller (FLC) based on the Levenberg–Marquardt (LM) optimization technique in coordination with bridge-type-fault-current limiter (BFCL) as the fault ride through (FRT) Strategy. The LM optimization-based control is an iterative process with a fast and robust response and is always convergent. The BFCL reduces the fault currents to rated values without compromising at ripples. A keen and critical comparison of the designed strategy is carried out with a conventionally tuned proportional-integral (PI) controller in coordination with the crowbar FRT strategy. A 100kW MATLAB/Simulink model of a photovoltaic system is used for simulation and analysis of unbalance faults at the point of common-coupling (PCC) and at 5 km away from PCC. It is found that grid-connected PVS is highly influenced by the fault type and less effected by the distribution line length. The simulation results authenticated smooth, stable, ripples with free, robust, and fault-tolerant behavior of the proposed scheme. Full article
(This article belongs to the Special Issue Grid Connected Photovoltaic Systems)
Show Figures

Figure 1

Back to TopTop