Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (118)

Search Parameters:
Keywords = electrical skin resistance

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 1475 KiB  
Article
In Situ 3D Printing of Conformal Bioflexible Electronics via Annealing PEDOT:PSS/PVA Composite Bio-Ink
by Xuegui Zhang, Chengbang Lu, Yunxiang Zhang, Zixi Cai, Yingning He and Xiangyu Liang
Polymers 2025, 17(11), 1479; https://doi.org/10.3390/polym17111479 - 26 May 2025
Viewed by 566
Abstract
High-performance flexible sensors capable of direct integration with biological tissues are essential for personalized health monitoring, assistive rehabilitation, and human–machine interaction. However, conventional devices face significant challenges in achieving conformal integration with biological surfaces, along with sufficient biomechanical compatibility and biocompatibility. This research [...] Read more.
High-performance flexible sensors capable of direct integration with biological tissues are essential for personalized health monitoring, assistive rehabilitation, and human–machine interaction. However, conventional devices face significant challenges in achieving conformal integration with biological surfaces, along with sufficient biomechanical compatibility and biocompatibility. This research presents an in situ 3D biomanufacturing strategy utilizing Direct Ink Writing (DIW) technology to fabricate functional bioelectronic interfaces directly onto human skin, based on a novel annealing PEDOT:PSS/PVA composite bio-ink. Central to this strategy is the utilization of a novel annealing PEDOT:PSS/PVA composite material, subjected to specialized processing involving freeze-drying and subsequent thermal annealing, which is then formulated into a DIW ink exhibiting excellent printability. Owing to the enhanced network structure resulting from this unique fabrication process, films derived from this composite material exhibit favorable electrical conductivity (ca. 6 S/m in the dry state and 2 S/m when swollen) and excellent mechanical stretchability (maximum strain reaching 170%). The material also demonstrates good adhesion to biological interfaces and high-fidelity printability. Devices fabricated using this material achieved good conformal integration onto a finger joint and demonstrated strain-sensitive, repeatable responses during joint flexion and extension, capable of effectively transducing local strain into real-time electrical resistance signals. This study validates the feasibility of using the DIW biomanufacturing technique with this novel material for the direct on-body fabrication of functional sensors. It offers new material and manufacturing paradigms for developing highly customized and seamlessly integrated bioelectronic devices. Full article
(This article belongs to the Special Issue Advances in Biomimetic Smart Hydrogels)
Show Figures

Figure 1

17 pages, 8321 KiB  
Article
Flexible Piezoresistive Sensor with High Stability Based on GO@PDMS-PU Porous Structure
by Qingfang Zhang, Yi Li, Xingyu Wang, Xiaoyu Zhang, Shuyi Liu, Hengyi Yuan, Xiaodong Yang, Da Li, Zeping Jin, Yujian Zhang, Yutong Liu and Zhengmai Bian
Symmetry 2025, 17(5), 773; https://doi.org/10.3390/sym17050773 - 16 May 2025
Cited by 1 | Viewed by 761
Abstract
In recent years, flexible piezoresistive sensors based on polydimethylsiloxane (PDMS) matrix materials have developed rapidly, showing broad application prospects in fields such as human motion monitoring, electronic skin, and intelligent robotics. However, achieving a balance between structural durability and fabrication simplicity remains challenging. [...] Read more.
In recent years, flexible piezoresistive sensors based on polydimethylsiloxane (PDMS) matrix materials have developed rapidly, showing broad application prospects in fields such as human motion monitoring, electronic skin, and intelligent robotics. However, achieving a balance between structural durability and fabrication simplicity remains challenging. Traditional methods for preparing PDMS flexible substrates with high porosity and high stability often require complex, costly processes. Breaking through the constraints of conventional material systems, this study innovatively combines the high elasticity of polydimethylsiloxane (PDMS) with the stochastically distributed porous topology of a sponge-derived biotemplate through biomimetic templating replication technology, fabricating a heterogeneous composite system with an architecturally asymmetric spatial network. After 5000 loading cycles, uncoated samples experienced a thickness reduction of 7.0 mm, while PDMS-coated samples showed minimal thickness changes (2.0–3.0 mm), positively correlated with curing agent content (5:1 to 20:1). The 5:1 ratio sample demonstrated exceptional mechanical stability. As evidenced, the PDMS film-encapsulated architecturally asymmetric spatial network demonstrates superior stress dissipation efficacy, effectively mitigating stress concentration phenomena inherent to symmetric configurations that induce matrix fracture, thereby achieving optimal mechanical stability. Compared to the pre-test resistance distribution of 10–248 Ω, after 5000 cyclic loading cycles, the uncoated samples exhibited a narrowed resistance range of 10–50 Ω, while PDMS-coated samples maintained a broader resistance range (10–240 Ω) as the curing agent ratio increased (from 20:1 to 5:1), demonstrating that increasing the curing agent ratio helps maintain conductive network stability. The 5:1 ratio sample displayed the lowest resistance variation rate attenuation—only 3% after 5000 cycles (vs. 80% for uncoated samples)—and consistently minimal attenuation at all stages, validating superior electrical stability. Under 0–6 kPa pressure, the 5:1 ratio device maintained a linear sensitivity of 0.157 kPa−1, outperforming some existing works. Human motion monitoring experiments further confirmed its reliable signal output. Furthermore, the architecturally asymmetric spatial network of the device enables superior conformability to complex curvilinear geometries, leveraging its structural anisotropy to achieve seamless interfacial adaptation. By synergistically optimizing material composition and structural design, this study provides a novel technical method for developing highly durable flexible electronic devices. Full article
(This article belongs to the Section Engineering and Materials)
Show Figures

Figure 1

28 pages, 6590 KiB  
Article
Pulse Sensors Based on Laser-Induced Graphene Transferred to Biocompatible Polyurethane Networks: Fabrication, Transfer Methods, Characterization, and Application
by Vanja Vojnović, Marko Spasenović, Ivan Pešić, Teodora Vićentić, Milena Rašljić Rafajilović, Stefan D. Ilić and Marija V. Pergal
Chemosensors 2025, 13(4), 122; https://doi.org/10.3390/chemosensors13040122 - 2 Apr 2025
Viewed by 1376
Abstract
Flexible, wearable biomedical sensors based on laser-induced graphene (LIG) have garnered significant attention due to a straightforward fabrication process and exceptional electrical and mechanical properties. However, most relevant studies rely on commercial polyimide precursors, which suffer from inadequate biocompatibility and weak adhesion between [...] Read more.
Flexible, wearable biomedical sensors based on laser-induced graphene (LIG) have garnered significant attention due to a straightforward fabrication process and exceptional electrical and mechanical properties. However, most relevant studies rely on commercial polyimide precursors, which suffer from inadequate biocompatibility and weak adhesion between the precursor material and the LIG layer. To address these challenges, we synthesized cross-linked polyurethanes (PUs) with good biocompatibility and used them as substrates for LIG-based wearable pulse sensors. During fabrication, we employed two methods of LIG transfer to achieve optimal transfer yield. We adjusted the thickness of PU films and tailored their mechanical and physicochemical properties by varying the soft segment content to achieve optimal sensor performance. Our findings demonstrate that the success of LIG transfer is strongly influenced by the structure and composition of the polymeric substrate. Tensile testing revealed that increasing the soft segment content in PU films significantly improved their tensile strength, elongation at break, and flexibility, with PU based on 50 wt.% soft segment content (PU-50) showing the best mechanical properties. LIG exhibited minimal sensitivity to humidity, while PU films maintained high transparency (>80% at 500 nm), and PU-50 was non-toxic, with less than 5% lactate dehydrogenase (LDH) release in endothelial cell cultures, confirming its biocompatibility. Adhesion tests demonstrated that LIG transferred onto PU-50 exhibited significantly stronger adhesion compared to other tested substrates, with only a 30% increase in electrical resistance after the Scotch tape test, ensuring stability for wearable sensors. The optimal substrate, a semicrystalline PU-50, yielded superior transfer efficiency. Among all tested sensors, the LIG/PU-50, featuring a 77 μm thick substrate with good mechanical properties and improved adhesion, exhibited the highest signal-to-noise ratio (SNR). This study showcases a skin-safe LIG/PU-based pulse sensor that has significant potential for applications as a wearable patch in medical and sports monitoring. Full article
Show Figures

Graphical abstract

12 pages, 4134 KiB  
Article
From Self-Cleaning to Self-Aware Solar Mirror Skin
by Anna Castaldo, Emilia Gambale and Giuseppe Vitiello
Appl. Sci. 2025, 15(7), 3696; https://doi.org/10.3390/app15073696 - 27 Mar 2025
Viewed by 350
Abstract
Self-cleaning coatings for solar mirrors aim to reduce water usage for cleaning, cut down on maintenance costs for solar fields, and lower the overall electricity production costs in concentrated solar power (CSP) systems. Various approaches have been developed for mirrors with back surface [...] Read more.
Self-cleaning coatings for solar mirrors aim to reduce water usage for cleaning, cut down on maintenance costs for solar fields, and lower the overall electricity production costs in concentrated solar power (CSP) systems. Various approaches have been developed for mirrors with back surface (BSM) and front surface (FSM) architectures, all sharing the characteristic that the self-cleaning coating serves as the outermost layer, acting as a “skin” that protects against fouling. A recent trend in this field is to enhance this “skin” with sensing capabilities, allowing it to self-monitor its performance in terms of soiling or failure, contributing to the digitalization of solar fields and CSP technology. Building on previous work with auxetic aluminum nitrides and ZnO transparent composites, which were developed to replace alumina as the self-cleaning layer in BSMs, this study explores the potential of adding sensing properties to these coatings. The approach leverages the piezoelectric properties of the materials, which can be linked to dust accumulation and surface soiling, as well as their electrical resistive behavior, which can help monitor potential failures. The promising d33 values of sputtered piezoelectric AlN and the tailored electrical properties of ZnO composites, combined with their self-cleaning effects and optical clarity across the full solar spectrum, suggest that these coatings could serve as an intelligent, self-aware skin for solar mirrors. Full article
(This article belongs to the Section Applied Thermal Engineering)
Show Figures

Figure 1

23 pages, 7634 KiB  
Review
Survey of Sustainable Wearable Strain Sensors Enabled by Biopolymers and Conductive Organic Polymers
by Cephas Amoah and W. G. Skene
Gels 2025, 11(4), 235; https://doi.org/10.3390/gels11040235 - 24 Mar 2025
Viewed by 826
Abstract
The field of wearable sensors has evolved with operating devices capable of measuring biomechanics and biometrics, and detecting speech. The transduction, being the conversion of the biosignal to a measurable and quantifiable electrical signal, is governed by a conductive organic polymer. Meanwhile, the [...] Read more.
The field of wearable sensors has evolved with operating devices capable of measuring biomechanics and biometrics, and detecting speech. The transduction, being the conversion of the biosignal to a measurable and quantifiable electrical signal, is governed by a conductive organic polymer. Meanwhile, the conformality of skin to the substrate is quintessential. Both the substrate and the conductive polymer must work in concert to reversibly deform with the user’s movements for motion tracking. While polydimethylsiloxane shows mechanical compliance as a sensor substrate, it is of environmental interest to replace it with sustainable and degradable alternatives. As both the bulk of the weight and area of the sensor consist of the substrate, using renewable and biodegradable materials for its preparation would be an important step toward improving the lifecycle of wearable sensors. This review highlights wearable resistive sensors that are prepared from naturally occurring polymers that are both sustainable and biodegradable. Conductive polythiophenes are also presented, as well as how they are integrated into the biopolymer for sensors showing mechanical compliance with skin. This polymer is highlighted because of its structural conformality, conductivity, and processability, ensuring it fulfils the requirements for its use in sensors without adversely affecting the overall sustainability and biodegradability of resistive sensors. Different sustainable resistive sensors are also presented, and their performance is compared to conventional sensors to illustrate the successful integration of the biosourced polymers into sensors without comprising the desired elasticity and sensitivity to movement. The current state-of-the-art in sustainable resistive sensors is presented, along with knowledge of how biopolymers from different fields can be leveraged in the rational design of the next generation of sustainable sensors that can potentially be composted after their use. Full article
Show Figures

Graphical abstract

27 pages, 11615 KiB  
Article
The Non-Antibacterial Effects of Azithromycin and Other Macrolides on the Bronchial Epithelial Barrier and Cellular Differentiation
by Arni Asbjarnarson, Jon Petur Joelsson, Fridrik R. Gardarsson, Snaevar Sigurdsson, Michael J. Parnham, Jennifer A. Kricker and Thorarinn Gudjonsson
Int. J. Mol. Sci. 2025, 26(5), 2287; https://doi.org/10.3390/ijms26052287 - 4 Mar 2025
Cited by 1 | Viewed by 1073
Abstract
The respiratory epithelium maintains the barrier against inhaled harmful agents. When barrier failure occurs, as in several respiratory diseases, acute or chronic inflammation leading to destructive effects and exacerbations can occur. Macrolides are used to treat a spectrum of infections but are also [...] Read more.
The respiratory epithelium maintains the barrier against inhaled harmful agents. When barrier failure occurs, as in several respiratory diseases, acute or chronic inflammation leading to destructive effects and exacerbations can occur. Macrolides are used to treat a spectrum of infections but are also known for off-label use. Some macrolides, particularly azithromycin (AZM), reduce exacerbations in chronic obstructive pulmonary disease (COPD), whereby its efficacy is thought to be due to its effects on inflammation and oxidative stress. In vitro data indicate that AZM reduces epithelial barrier failure, evidenced by increased transepithelial electrical resistance (TEER). Here, we compared the effects of macrolides on differentiation and barrier integrity in VA10 cells, a bronchial epithelial cell line for 14 and 21 days. Erythromycin, clarithromycin, roxithromycin, AZM, solithromycin, and tobramycin (an aminoglycoside) were analyzed using RNA sequencing, barrier integrity assays, and immunostaining to evaluate effects on the epithelium. All macrolides affected the gene expression of pathways involved in epithelial-to-mesenchymal transition, metabolism, and immunomodulation. Treatment with AZM, clarithromycin, and erythromycin raised TEER and induced phospholipid retention. AZM treatment was distinct in terms of enhancement of the epithelial barrier, retention of phospholipids, vesicle build-up, and its effect on gene sets related to keratinocyte differentiation and establishment of skin barrier. Full article
(This article belongs to the Section Molecular Pharmacology)
Show Figures

Figure 1

19 pages, 10502 KiB  
Article
Flexible and Washable Poly(3,4-ethylenedioxythiophene): Polystyrene Sulfonate/Polyvinyl Alcohol Fabric Dry Electrode for Long-Term Electroencephalography Signals Measurement
by Fangmeng Zeng, Guanghua Wang, Chenyi Sun, Jiayi Gao, Shanqun Ji and Quanxi Zhang
Polymers 2025, 17(5), 683; https://doi.org/10.3390/polym17050683 - 4 Mar 2025
Viewed by 1017
Abstract
Recent advancements in smart textiles have facilitated their extensive application in wearable health monitoring, particularly in brain activity measurement. This study introduces a flexible and washable fabric dry electroencephalography (EEG) electrode designed for brain activity measurement. The fabric dry electrode is constructed from [...] Read more.
Recent advancements in smart textiles have facilitated their extensive application in wearable health monitoring, particularly in brain activity measurement. This study introduces a flexible and washable fabric dry electroencephalography (EEG) electrode designed for brain activity measurement. The fabric dry electrode is constructed from electrically conductive polyester fabric with a resistivity of 0.09 Ω·cm, achieved by applying a PEDOT: PSS/PVA conductive paste coating on the textile substrate. A comparative analysis of the tensile properties between the conductive and untreated polyester fabric was conducted. The SEM images demonstrated that the PEDOT: PSS/PVA conductive polymer composite resulted in a uniform coating on the fabric surface. When enveloped in elastic foam, the fabric dry electrode maintained a low and stable electrode–skin contact impedance during prolonged EEG monitoring. Additionally, the short circuit noise level of the fabric dry electrode exhibited superior performance compared to both Ag/AgCl wet and finger dry electrode. The EEG signals acquired from the fabric dry electrode were comparable to those recorded by the Ag/AgCl wet electrode. Moreover, the fabric electrode effectively captured clear and reliable EEG signals, even after undergoing 10 washing cycles. The fabric dry electrode indicates good sweat resistance and biocompatibility during prolonged monitoring. Full article
(This article belongs to the Section Smart and Functional Polymers)
Show Figures

Figure 1

18 pages, 5510 KiB  
Article
A New Design for Switched-Mode Dental Iontophoresis System Using a Dual-Return Probe
by Serkan Dişlitaş
Appl. Sci. 2025, 15(4), 1748; https://doi.org/10.3390/app15041748 - 8 Feb 2025
Viewed by 1441
Abstract
In practice, continuous and pulse direct current (DC) methods are embodied in classical dental iontophoresis systems (CDISs) for the treatment of dentin hypersensitivity (DH). Changes in body electrical resistance and polarization occurrence are the main problems in dental iontophoresis applications. Moreover, continuous DC [...] Read more.
In practice, continuous and pulse direct current (DC) methods are embodied in classical dental iontophoresis systems (CDISs) for the treatment of dentin hypersensitivity (DH). Changes in body electrical resistance and polarization occurrence are the main problems in dental iontophoresis applications. Moreover, continuous DC application may cause discomforts such as irritation, burning and itching on the skin. For these reasons, it is preferred to use pulse DC instead of continuous DC. However, in pulse DC applications, the treatment period is prolonged depending on the decrease in the electrical charge flow. On the other hand, the pain threshold of teeth when the electric current is applied varies from person to person. In this study, in order to reduce the problems caused by the use of CDIS methods for the treatment of DH, a microcontroller-based switched-mode dental iontophoresis system (SMDIS) using a dual-return probe (RP) is designed, and its performance is compared with CDIS methods. According to the results, the new SMDIS both reduces the polarization effect as in the classical pulse DC method and shortens the prolonged treatment duration in pulse DC by raising the pain threshold of teeth due to increased ion transfer, which is a great advantage over former methods. Full article
Show Figures

Figure 1

24 pages, 5048 KiB  
Review
Humidity Sensing Using Polymers: A Critical Review of Current Technologies and Emerging Trends
by Jintian Qian, Ruiqin Tan, Mingxia Feng, Wenfeng Shen, Dawu Lv and Weijie Song
Chemosensors 2024, 12(11), 230; https://doi.org/10.3390/chemosensors12110230 - 2 Nov 2024
Cited by 7 | Viewed by 6094
Abstract
In the post-pandemic era, human demand for a healthy lifestyle and a smart society has surged, leading to vibrant growth in the field of flexible electronic sensor technology for health monitoring. Flexible polymer humidity sensors are not only capable of the real-time monitoring [...] Read more.
In the post-pandemic era, human demand for a healthy lifestyle and a smart society has surged, leading to vibrant growth in the field of flexible electronic sensor technology for health monitoring. Flexible polymer humidity sensors are not only capable of the real-time monitoring of human respiration and skin moisture information but also serve as a non-contact human–machine interaction method. In addition, the development of moist-electric generation technology is expected to break free from the traditional reliance of flexible electronic devices on power equipment, which is of significant importance for the miniaturization, reliability, and environmentally friendly development of flexible devices. Currently, flexible polymer humidity sensors are playing a significant role in the field of wearable electronic devices and thus have attracted considerable attention. This review begins by introducing the structural types and working principles of various humidity sensors, including the types of capacitive, impedance/resistive, frequency-based, fiber optic, and voltage-based sensors. It mainly focuses on the latest research advancements in flexible polymer humidity sensors, particularly in the modification of humidity-sensitive materials, sensor fabrication, and hygrosensitivity mechanisms. Studies on material composites including different types of polymers, polymers combined with porous nanostructured materials, polymers combined with metal oxides, and two-dimensional materials are reviewed, along with a comparative summary of the fabrication and performance mechanisms of related devices. This paper concludes with a discussion on the current challenges and opportunities faced by flexible polymer humidity sensors, providing new research perspectives for their future development. Full article
Show Figures

Figure 1

25 pages, 6758 KiB  
Article
Comprehensive Advanced Physicochemical Characterization and In Vitro Human Cell Culture Assessment of BMS-202: A Novel Inhibitor of Programmed Cell Death Ligand
by Hasham Shafi, Andrea J. Lora, Haley M. Donow, Sally E. Dickinson, Georg T. Wondrak, H.-H. Sherry Chow, Clara Curiel-Lewandrowski and Heidi M. Mansour
Pharmaceutics 2024, 16(11), 1409; https://doi.org/10.3390/pharmaceutics16111409 - 1 Nov 2024
Cited by 1 | Viewed by 2140
Abstract
Background/Objectives: BMS-202, is a potent small molecule with demonstrated antitumor activity. The study aimed to comprehensively characterize the physical and chemical properties of BMS-202 and evaluate its suitability for topical formulation, focusing on uniformity, stability and safety profiles. Methods: A range of analytical [...] Read more.
Background/Objectives: BMS-202, is a potent small molecule with demonstrated antitumor activity. The study aimed to comprehensively characterize the physical and chemical properties of BMS-202 and evaluate its suitability for topical formulation, focusing on uniformity, stability and safety profiles. Methods: A range of analytical techniques were employed to characterize BMS-202. Scanning Electron Microscopy (SEM) was used to assess morphology, Differential Scanning Calorimetry (DSC) provided insights of thermal behavior, and Hot-Stage Microscopy (HSM) corroborated these thermal behaviors. Molecular fingerprinting was conducted using Raman spectroscopy and Fourier Transform Infrared (FTIR) spectroscopy, with chemical uniformity of the batch further validated by mapping through FTIR and Raman microscopies. The residual water content was measured using Karl Fisher Coulometric titration, and vapor sorption isotherms examined moisture uptake across varying relative humidity levels. In vitro safety assessments involved testing with skin epithelial cell lines, such as HaCaT and NHEK, and Transepithelial Electrical Resistance (TEER) to evaluate barrier integrity. Results: SEM revealed a distinctive needle-like morphology, while DSC indicated a sharp melting point at 110.90 ± 0.54 ℃ with a high enthalpy of 84.41 ± 0.38 J/g. HSM confirmed the crystalline-to-amorphous transition at the melting point. Raman and FTIR spectroscopy, alongside chemical imaging, confirmed chemical uniformity as well as validated the batch consistency. A residual water content of 2.76 ± 1.37 % (w/w) and minimal moisture uptake across relative humidity levels demonstrated its low hygroscopicity and suitability for topical formulations. Cytotoxicity testing showed dose-dependent reduction in skin epithelial cell viability at high concentrations (100 µM and 500 µM), with lower doses (0.1 µM to 10 µM) demonstrating acceptable safety. TEER studies indicated that BMS-202 does not disrupt the HaCaT cell barrier function. Conclusions: The findings from this study establish that BMS-202 has promising physicochemical and in vitro characteristics at therapeutic concentrations for topical applications, providing a foundation for future formulation development focused on skin-related cancers or localized immune modulation. Full article
(This article belongs to the Special Issue Dosage Form Design and Delivery Therapy for Skin Disorders)
Show Figures

Figure 1

10 pages, 1984 KiB  
Article
Ultra-Thin Highly Sensitive Electronic Skin for Temperature Monitoring
by Yuxin Wang, Yuan Meng, Jin Ning, Peike Wang, Yang Ye, Jingjing Luo, Ao Yin, Zhongqi Ren, Haipeng Liu, Xue Qi, Sisi He, Suzhu Yu and Jun Wei
Polymers 2024, 16(21), 2987; https://doi.org/10.3390/polym16212987 - 24 Oct 2024
Cited by 1 | Viewed by 1484
Abstract
Electronic skin capable of reliable monitoring of human skin temperature is crucial for the advancement of non-invasive clinical biomonitoring, disease diagnosis, and health surveillance. Ultra-thin temperature sensors, with excellent mechanical flexibility and robustness, can conformably adhere to uneven skin surfaces, making them ideal [...] Read more.
Electronic skin capable of reliable monitoring of human skin temperature is crucial for the advancement of non-invasive clinical biomonitoring, disease diagnosis, and health surveillance. Ultra-thin temperature sensors, with excellent mechanical flexibility and robustness, can conformably adhere to uneven skin surfaces, making them ideal candidates. However, achieving high sensitivity often demands sacrificing flexibility, rendering the development of temperature sensors combining both qualities a challenging task. In this study, we utilized a low-cost drop-casting technique to print ultra-thin and lightweight (thickness: approximately 3 µm, weight: 0.61 mg) temperature sensors based on a combination of vanadium dioxide and PEDOT:PSS at room temperature and atmospheric conditions. These sensors exhibit high sensitivity (temperature coefficient of resistance: −5.11%/°C), rapid response and recovery times (0.36 s), and high-temperature accuracy (0.031 °C). Furthermore, they showcased remarkable durability in extreme bending conditions (bending radius = 400 µm), along with stable electrical performance over approximately 2400 bending cycles. This work offers a low-cost, simple, and scalable method for manufacturing ultra-thin and lightweight electronic skins for temperature monitoring, which seamlessly integrate exceptional temperature-measuring capabilities with optimal flexibility. Full article
(This article belongs to the Special Issue Nature-Inspired and Polymers-Based Flexible Electronics and Sensors)
Show Figures

Figure 1

12 pages, 5884 KiB  
Article
Closed-Form Solutions for Current Distribution in Ladder-Type Textile Heaters
by Kaspar M. B. Jansen
Thermo 2024, 4(4), 433-444; https://doi.org/10.3390/thermo4040023 - 26 Sep 2024
Viewed by 1528
Abstract
Textile heaters are made from knitted conductive yarns integrated into their fabric, making them stretchable, washable, breathable and suitable for close-to-skin wear. However, the non-zero resistance in the lead wires causes non-uniform power distribution, which presents a design challenge. To address this, the [...] Read more.
Textile heaters are made from knitted conductive yarns integrated into their fabric, making them stretchable, washable, breathable and suitable for close-to-skin wear. However, the non-zero resistance in the lead wires causes non-uniform power distribution, which presents a design challenge. To address this, the electrical performance of the heaters is modeled as an n-ladder resistor network. By using the finite difference method, simple, closed-form expressions are derived for networks with their power source connected to input terminals A1B1 and A1Bn, respectively. The exact results are then used to derive approximations and design criteria. The solutions for the ladder networks presented in this paper apply to a wider class of physical problems, such as irrigation systems, transformer windings, and cooling fins. Full article
Show Figures

Figure 1

25 pages, 9089 KiB  
Article
Remotely Powered Two-Wire Cooperative Sensors for Bioimpedance Imaging Wearables
by Olivier Chételat, Michaël Rapin, Benjamin Bonnal, André Fivaz, Benjamin Sporrer, James Rosenthal and Josias Wacker
Sensors 2024, 24(18), 5896; https://doi.org/10.3390/s24185896 - 11 Sep 2024
Viewed by 1506
Abstract
Bioimpedance imaging aims to generate a 3D map of the resistivity and permittivity of biological tissue from multiple impedance channels measured with electrodes applied to the skin. When the electrodes are distributed around the body (for example, by delineating a cross section of [...] Read more.
Bioimpedance imaging aims to generate a 3D map of the resistivity and permittivity of biological tissue from multiple impedance channels measured with electrodes applied to the skin. When the electrodes are distributed around the body (for example, by delineating a cross section of the chest or a limb), bioimpedance imaging is called electrical impedance tomography (EIT) and results in functional 2D images. Conventional EIT systems rely on individually cabling each electrode to master electronics in a star configuration. This approach works well for rack-mounted equipment; however, the bulkiness of the cabling is unsuitable for a wearable system. Previously presented cooperative sensors solve this cabling problem using active (dry) electrodes connected via a two-wire parallel bus. The bus can be implemented with two unshielded wires or even two conductive textile layers, thus replacing the cumbersome wiring of the conventional star arrangement. Prior research demonstrated cooperative sensors for measuring bioimpedances, successfully realizing a measurement reference signal, sensor synchronization, and data transfer though still relying on individual batteries to power the sensors. Subsequent research using cooperative sensors for biopotential measurements proposed a method to remove batteries from the sensors and have the central unit supply power over the two-wire bus. Building from our previous research, this paper presents the application of this method to the measurement of bioimpedances. Two different approaches are discussed, one using discrete, commercially available components, and the other with an application-specific integrated circuit (ASIC). The initial experimental results reveal that both approaches are feasible, but the ASIC approach offers advantages for medical safety, as well as lower power consumption and a smaller size. Full article
Show Figures

Figure 1

13 pages, 1689 KiB  
Article
The Influence of Retinol Ointment on Rabbit Skin (Oryctolagus cuniculus) Ion Transport—An In Vitro Study
by Klaudia Dłubała, Sandra Wasiek, Patrycja Pilarska, Karolina Szewczyk-Golec, Celestyna Mila-Kierzenkowska, Krzysztof Z. Łączkowski, Marta Sobiesiak, Marcin Gackowski, Bartosz Tylkowski and Iga Hołyńska-Iwan
Int. J. Mol. Sci. 2024, 25(17), 9670; https://doi.org/10.3390/ijms25179670 - 6 Sep 2024
Cited by 1 | Viewed by 1062
Abstract
Retinoids are known to improve the condition of the skin. Transepithelial transport of sodium and chloride ions is important for proper skin function. So far, the effect of applying vitamin A preparations to the skin on ion transport has not been evaluated. In [...] Read more.
Retinoids are known to improve the condition of the skin. Transepithelial transport of sodium and chloride ions is important for proper skin function. So far, the effect of applying vitamin A preparations to the skin on ion transport has not been evaluated. In the study, electrophysiological parameters, including transepithelial electric potential (PD) and transepithelial resistance (R), of rabbit skin specimens after 24 h exposure to retinol ointment (800 mass units/g) were measured in a modified Ussing chamber. The R of the fragments incubated with retinol was significantly different than that of the control skin samples incubated in iso-osmotic Ringer solution. For the controls, the PD values were negative, whereas the retinol-treated specimens revealed positive PD values. Mechanical–chemical stimulation with the use of inhibitors of the transport of sodium (amiloride) or chloride (bumetanide) ions revealed specific changes in the maximal and minimal PD values measured for the retinol-treated samples. Retinol was shown to slightly modify the transport pathways of sodium and chloride ions. In particular, an intensification of the chloride ion secretion from keratinocytes was observed. The proposed action may contribute to deep hydration and increase skin tightness, limiting the action of other substances on its surface. Full article
(This article belongs to the Special Issue Transport of Nutrients and Ions Relevant to Human Pathophysiology)
Show Figures

Figure 1

35 pages, 18128 KiB  
Article
Straightforward Production Methods for Diverse Porous PEDOT:PSS Structures and Their Characterization
by Rike Brendgen, Thomas Grethe and Anne Schwarz-Pfeiffer
Sensors 2024, 24(15), 4919; https://doi.org/10.3390/s24154919 - 29 Jul 2024
Cited by 3 | Viewed by 1727
Abstract
Porous conductive polymer structures, in particular Poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) structures, are gaining in importance due to their versatile fields of application as sensors, hydrogels, or supercapacitors, to name just a few. Moreover, (porous) conducting polymers have become of interest for wearable and [...] Read more.
Porous conductive polymer structures, in particular Poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) structures, are gaining in importance due to their versatile fields of application as sensors, hydrogels, or supercapacitors, to name just a few. Moreover, (porous) conducting polymers have become of interest for wearable and smart textile applications due to their biocompatibility, which enables applications with direct skin contact. Therefore, there is a huge need to investigate distinct, straightforward, and textile-compatible production methods for the fabrication of porous PEDOT:PSS structures. Here, we present novel and uncomplicated approaches to producing diverse porous PEDOT:PSS structures and characterize them thoroughly in terms of porosity, electrical resistance, and their overall appearance. Production methods comprise the incorporation of micro cellulose, the usage of a blowing agent, creating a sponge-like structure, and spraying onto a porous base substrate. This results in the fabrication of various porous structures, ranging from thin and slightly porous to thick and highly porous. Depending on the application, these structures can be modified and integrated into electronic components or wearables to serve as porous electrodes, sensors, or other functional devices. Full article
Show Figures

Graphical abstract

Back to TopTop