Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = chemiresistive biosensors

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 2749 KiB  
Article
Graphene Amination towards Its Grafting by Antibodies for Biosensing Applications
by Maxim K. Rabchinskii, Nadezhda A. Besedina, Maria Brzhezinskaya, Dina Yu. Stolyarova, Sergei A. Ryzhkov, Sviatoslav D. Saveliev, Grigorii A. Antonov, Marina V. Baidakova, Sergei I. Pavlov, Demid A. Kirilenko, Aleksandr V. Shvidchenko, Polina D. Cherviakova and Pavel N. Brunkov
Nanomaterials 2023, 13(11), 1730; https://doi.org/10.3390/nano13111730 - 25 May 2023
Cited by 13 | Viewed by 2208
Abstract
The facile synthesis of biografted 2D derivatives complemented by a nuanced understanding of their properties are keystones for advancements in biosensing technologies. Herein, we thoroughly examine the feasibility of aminated graphene as a platform for the covalent conjugation of monoclonal antibodies towards [...] Read more.
The facile synthesis of biografted 2D derivatives complemented by a nuanced understanding of their properties are keystones for advancements in biosensing technologies. Herein, we thoroughly examine the feasibility of aminated graphene as a platform for the covalent conjugation of monoclonal antibodies towards human IgG immunoglobulins. Applying core-level spectroscopy methods, namely X-ray photoelectron and absorption spectroscopies, we delve into the chemistry and its effect on the electronic structure of the aminated graphene prior to and after the immobilization of monoclonal antibodies. Furthermore, the alterations in the morphology of the graphene layers upon the applied derivatization protocols are assessed by electron microscopy techniques. Chemiresistive biosensors composed of the aerosol-deposited layers of the aminated graphene with the conjugated antibodies are fabricated and tested, demonstrating a selective response towards IgM immunoglobulins with a limit of detection as low as 10 pg/mL. Taken together, these findings advance and outline graphene derivatives’ application in biosensing as well as hint at the features of the alterations of graphene morphology and physics upon its functionalization and further covalent grafting by biomolecules. Full article
Show Figures

Figure 1

13 pages, 2795 KiB  
Article
Superhydrophobic Paper-Based Microfluidic Field-Effect Transistor Biosensor Functionalized with Semiconducting Single-Walled Carbon Nanotube and DNAzyme for Hypocalcemia Diagnosis
by Hui Wang, Ruipeng Chen, Fan Zhang, Zhixue Yu, Yue Wang, Zhonglin Tang, Liang Yang, Xiangfang Tang and Benhai Xiong
Int. J. Mol. Sci. 2022, 23(14), 7799; https://doi.org/10.3390/ijms23147799 - 15 Jul 2022
Cited by 15 | Viewed by 2983
Abstract
Hypocalcemia is caused by a sharp decline in blood calcium concentration after dairy cow calving, which can lead to various diseases or even death. It is necessary to develop an inexpensive, easy-to-operate, reliable sensor to diagnose hypocalcemia. The cellulose-paper-based microfluidic field-effect biosensor is [...] Read more.
Hypocalcemia is caused by a sharp decline in blood calcium concentration after dairy cow calving, which can lead to various diseases or even death. It is necessary to develop an inexpensive, easy-to-operate, reliable sensor to diagnose hypocalcemia. The cellulose-paper-based microfluidic field-effect biosensor is promising for point-of-care, but it has poor mechanical strength and a short service life after exposure to an aqueous solution. Octadecyltrichlorosilane (OTS), as a popular organosilane derivative, can improve the hydrophobicity of cellulose paper to overcome the shortage of cellulose paper. In this work, OTS was used to produce the superhydrophobic cellulose paper that enhances the mechanical strength and short service life of MFB, and a microfluidic field-effect biosensor (MFB) with semiconducting single-walled carbon nanotubes (SWNTs) and DNAzyme was then developed for the Ca2+ determination. Pyrene carboxylic acid (PCA) attached to SWNTs through a non-covalent π-π stacking interaction provided a carboxyl group that can bond with an amino group of DNAzyme. Two DNAzymes with different sensitivities were designed by changing the sequence length and cleavage site, which were functionalized with SPFET/SWNTs-PCA to form Dual-MFB, decreasing the interference of impurities in cow blood. After optimizing the detecting parameters, Dual-MFB could determine the Ca2+ concentration in the range of 25 μM to 5 mM, with a detection limit of 10.7 μM. The proposed Dual-MFB was applied to measure Ca2+ concentration in cow blood, which provided a new method to diagnose hypocalcemia after dairy cow calving. Full article
(This article belongs to the Collection State-of-the-Art Materials Science in China)
Show Figures

Graphical abstract

13 pages, 9315 KiB  
Article
Effect of Al2O3 Passive Layer on Stability and Doping of MoS2 Field-Effect Transistor (FET) Biosensors
by Tung Pham, Ying Chen, Jhoann Lopez, Mei Yang, Thien-Toan Tran and Ashok Mulchandani
Biosensors 2021, 11(12), 514; https://doi.org/10.3390/bios11120514 - 13 Dec 2021
Cited by 8 | Viewed by 4772
Abstract
Molybdenum disulfide (MoS2) features a band gap of 1.3 eV (indirect) to 1.9 eV (direct). This tunable band gap renders MoS2 a suitable conducting channel for field-effect transistors (FETs). In addition, the highly sensitive surface potential in MoS2 layers [...] Read more.
Molybdenum disulfide (MoS2) features a band gap of 1.3 eV (indirect) to 1.9 eV (direct). This tunable band gap renders MoS2 a suitable conducting channel for field-effect transistors (FETs). In addition, the highly sensitive surface potential in MoS2 layers allows the feasibility of FET applications in biosensors, where direct immobilization and detection of biological molecules are conducted in wet conditions. In this work, we report, for the first time, the degradation of chemical vapor deposition (CVD) grown MoS2 FET-based sensors in the presence of phosphate buffer and water, which caused false positive response in detection. We conclude the degradation was originated by physical delamination of MoS2 thin films from the SiO2 substrate. The problem was alleviated by coating the sensors with a 30 nm thick aluminum oxide (Al2O3) layer using atomic layer deposition technique (ALD). This passive oxide thin film not only acted as a protecting layer against the device degradation but also induced a strong n-doping onto MoS2, which permitted a facile method of detection in MoS2 FET-based sensors using a low-power mode chemiresistive I-V measurement at zero gate voltage (Vgate = 0 V). Additionally, the oxide layer provided available sites for facile functionalization with bioreceptors. As immunoreaction plays a key role in clinical diagnosis and environmental analysis, our work presented a promising application using such enhanced Al2O3-coated MoS2 chemiresistive biosensors for detection of HIgG with high sensitivity and selectivity. The biosensor was successfully applied to detect HIgG in artificial urine, a complex matrix containing organics and salts. Full article
(This article belongs to the Special Issue Electrochemistry and Spectroscopy-Based Biosensors)
Show Figures

Figure 1

11 pages, 6980 KiB  
Communication
Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
by Phil M. Smith, Indorica Sutradhar, Maxwell Telmer, Rishikesh Magar, Amir Barati Farimani and B. Reeja-Jayan
Sensors 2021, 21(19), 6335; https://doi.org/10.3390/s21196335 - 22 Sep 2021
Cited by 3 | Viewed by 3328
Abstract
A longstanding challenge for accurate sensing of biomolecules such as proteins concerns specifically detecting a target analyte in a complex sample (e.g., food) without suffering from nonspecific binding or interactions from the target itself or other analytes present in the sample. Every sensor [...] Read more.
A longstanding challenge for accurate sensing of biomolecules such as proteins concerns specifically detecting a target analyte in a complex sample (e.g., food) without suffering from nonspecific binding or interactions from the target itself or other analytes present in the sample. Every sensor suffers from this fundamental drawback, which limits its sensitivity, specificity, and longevity. Existing efforts to improve signal-to-noise ratio involve introducing additional steps to reduce nonspecific binding, which increases the cost of the sensor. Conducting polymer-based chemiresistive biosensors can be mechanically flexible, are inexpensive, label-free, and capable of detecting specific biomolecules in complex samples without purification steps, making them very versatile. In this paper, a poly (3,4-ethylenedioxyphene) (PEDOT) and poly (3-thiopheneethanol) (3TE) interpenetrating network on polypropylene–cellulose fabric is used as a platform for a chemiresistive biosensor, and the specific and nonspecific binding events are studied using the Biotin/Avidin and Gliadin/G12-specific complementary binding pairs. We observed that specific binding between these pairs results in a negative ΔR with the addition of the analyte and this response increases with increasing analyte concentration. Nonspecific binding was found to have the opposite response, a positive ΔR upon the addition of analyte was seen in nonspecific binding cases. We further demonstrate the ability of the sensor to detect a targeted protein in a dual-protein analyte solution. The machine-learning classifier, random forest, predicted the presence of Biotin with 75% accuracy in dual-analyte solutions. This capability of distinguishing between specific and nonspecific binding can be a step towards solving the problem of false positives or false negatives to which all biosensors are susceptible. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

43 pages, 9328 KiB  
Review
An Overview of Artificial Olfaction Systems with a Focus on Surface Plasmon Resonance for the Analysis of Volatile Organic Compounds
by Marielle El Kazzy, Jonathan S. Weerakkody, Charlotte Hurot, Raphaël Mathey, Arnaud Buhot, Natale Scaramozzino and Yanxia Hou
Biosensors 2021, 11(8), 244; https://doi.org/10.3390/bios11080244 - 23 Jul 2021
Cited by 47 | Viewed by 9040
Abstract
The last three decades have witnessed an increasing demand for novel analytical tools for the analysis of gases including odorants and volatile organic compounds (VOCs) in various domains. Traditional techniques such as gas chromatography coupled with mass spectrometry, although very efficient, present several [...] Read more.
The last three decades have witnessed an increasing demand for novel analytical tools for the analysis of gases including odorants and volatile organic compounds (VOCs) in various domains. Traditional techniques such as gas chromatography coupled with mass spectrometry, although very efficient, present several drawbacks. Such a context has incited the research and industrial communities to work on the development of alternative technologies such as artificial olfaction systems, including gas sensors, olfactory biosensors and electronic noses (eNs). A wide variety of these systems have been designed using chemiresistive, electrochemical, acoustic or optical transducers. Among optical transduction systems, surface plasmon resonance (SPR) has been extensively studied thanks to its attractive features (high sensitivity, label free, real-time measurements). In this paper, we present an overview of the advances in the development of artificial olfaction systems with a focus on their development based on propagating SPR with different coupling configurations, including prism coupler, wave guide, and grating. Full article
(This article belongs to the Special Issue Surface Plasmon Resonance for Biosensing)
Show Figures

Figure 1

15 pages, 4266 KiB  
Article
Ultrasensitive, Label Free, Chemiresistive Nanobiosensor Using Multiwalled Carbon Nanotubes Embedded Electrospun SU-8 Nanofibers
by Matta Durga Prakash, Siva Rama Krishna Vanjari, Chandra Shekhar Sharma and Shiv Govind Singh
Sensors 2016, 16(9), 1354; https://doi.org/10.3390/s16091354 - 23 Aug 2016
Cited by 26 | Viewed by 8065
Abstract
This paper reports the synthesis and fabrication of aligned electrospun nanofibers derived out of multiwalled carbon nanotubes (MWCNTs) embedded SU-8 photoresist, which are targeted towards ultrasensitive biosensor applications. The ultrasensitivity (detection in the range of fg/mL) and the specificity of these biosensors were [...] Read more.
This paper reports the synthesis and fabrication of aligned electrospun nanofibers derived out of multiwalled carbon nanotubes (MWCNTs) embedded SU-8 photoresist, which are targeted towards ultrasensitive biosensor applications. The ultrasensitivity (detection in the range of fg/mL) and the specificity of these biosensors were achieved by complementing the inherent advantages of MWCNTs such as high surface to volume ratio and excellent electrical and transduction properties with the ease of surface functionalization of SU-8. The electrospinning process was optimized to precisely align nanofibers in between two electrodes of a copper microelectrode array. MWCNTs not only enhance the conductivity of SU-8 nanofibers but also act as transduction elements. In this paper, MWCNTs were embedded way beyond the percolation threshold and the optimum percentage loading of MWCNTs for maximizing the conductivity of nanofibers was figured out experimentally. As a proof of concept, the detection of myoglobin, an important biomarker for on-set of Acute Myocardial Infection (AMI) has been demonstrated by functionalizing the nanofibers with anti-myoglobin antibodies and carrying out detection using a chemiresistive method. This simple and robust device yielded a detection limit of 6 fg/mL. Full article
(This article belongs to the Special Issue Carbon MEMS and NEMS for Sensor Applications)
Show Figures

Figure 1

Back to TopTop