Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = autostrainer

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
8 pages, 190 KB  
Article
SPECT Perfusion Defects and Impaired Strain in Mild COVID-19: A Multimodal Imaging Study with a Female-Predominant Cohort
by Ji-Cheng Hsieh, Tanzim Bhuiya, Jonathan H. Sussman, Tony Dong, Danni Fu, David W. Wu and John Makaryus
Healthcare 2025, 13(5), 548; https://doi.org/10.3390/healthcare13050548 - 4 Mar 2025
Viewed by 3719
Abstract
Background/Objectives: This study investigates the association between mild first-wave COVID-19 infection and subclinical abnormalities in echocardiographic strain parameters and myocardial perfusion using single-photon emission computed tomography (SPECT). Methods: We conducted a retrospective analysis of patients from June 2020 to March 2021 with a [...] Read more.
Background/Objectives: This study investigates the association between mild first-wave COVID-19 infection and subclinical abnormalities in echocardiographic strain parameters and myocardial perfusion using single-photon emission computed tomography (SPECT). Methods: We conducted a retrospective analysis of patients from June 2020 to March 2021 with a history of mild first-wave COVID-19 infection, presenting with nonspecific cardiac symptoms and referred for SPECT myocardial perfusion stress testing. Patients had no obstructive coronary artery disease (CAD) on follow-up invasive angiography or cardiac computed tomography angiography (CCTA) and had transthoracic echocardiographic images of sufficient quality for strain analysis using AutoSTRAIN (TOMTEC®). Results: Fifteen patients met the inclusion criteria. SPECT and echocardiography were reviewed for perfusion and strain defects, respectively, in the inferior, anterior, lateral, and septal myocardial segments. All patients had at least one perfusion abnormality on SPECT: 2/15 (13%) had a fixed defect in one segment, 3/15 (20%) in two, 3/15 (20%) in three, and 7/15 (47%) in four. While 13/15 (87%) patients had normal qualitative findings on traditional echocardiography, 12/15 (80%) had abnormal global longitudinal strain (GLS) (>−18%) and transregional wall strain abnormality in at least one segment. Abnormalities on SPECT and strain echocardiography demonstrated a moderate but significant 60% concordance, with an intraclass correlation coefficient (ICC) of 0.486 (p = 0.028). Conclusions: Patients with ‘mild’ COVID-19 infection demonstrated a high frequency of abnormalities on SPECT myocardial perfusion imaging (even in the absence of obstructive CAD) which appeared to be concordant with abnormal strain parameters on echocardiography, suggesting possible subclinical effects on myocardial tissue. Full article
9 pages, 1889 KB  
Article
Trajectory of Diastolic Function after Heart Transplantation as Assessed by Left Atrial Deformation Analysis
by Borbála Edvi, Alexandra Assabiny, Tímea Teszák, Máté Tolvaj, Alexandra Fábián, István Hartyánszky, Miklós Pólos, Bálint Károly Lakatos, Hajnalka Vágó, Balázs Sax, Béla Merkely and Attila Kovács
Diagnostics 2024, 14(11), 1136; https://doi.org/10.3390/diagnostics14111136 - 29 May 2024
Viewed by 2009
Abstract
Diastolic dysfunction (DD) is a prevalent and clinically significant complication after heart transplantation (HTX). We aimed to characterize the diastolic function of HTX recipients with both short-term and long-term follow-ups by applying left atrial (LA) deformation analysis. We consecutively enrolled and followed up [...] Read more.
Diastolic dysfunction (DD) is a prevalent and clinically significant complication after heart transplantation (HTX). We aimed to characterize the diastolic function of HTX recipients with both short-term and long-term follow-ups by applying left atrial (LA) deformation analysis. We consecutively enrolled and followed up with 33 HTX patients. Three assessments were performed one month, 3–5 months, and 3–5 years after surgery. Beyond conventional echocardiographic measurements, apical four-chamber views optimized for speckle tracking analysis were acquired and post-processed by dedicated software solutions (TomTec AutoStrain LA and LV). Left atrial phasic functions were characterized by reservoir, conduit, and contraction strains. We categorized diastolic function according to current guidelines (normal diastolic function, indeterminate, DD). At the first assessment, nine (27%) patients were in the DD category, and eleven (33%) were indeterminate. At the second assessment, only one patient (3%) remained in the DD category and six (18%) were indeterminate. At the third assessment, 100% of patients were categorized as having normal diastolic function. LA reservoir strain gradually increased over time. LA contraction strain significantly improved from the second to the third assessment. We found a correlation between the LA reservoir strain and NT-proBNP (r = 0.40, p < 0.05). DD is prevalent immediately after HTX but rare until the end of the first postoperative quarter. Speckle tracking analysis enables the characterization of LA phasic functions that may reflect both short- and long-term changes in diastolic function and correlate with NT-proBNP. Full article
(This article belongs to the Special Issue Echocardiography in the Diagnosis of Cardiac Disease)
Show Figures

Figure 1

18 pages, 5836 KB  
Article
CFD Analysis of the Pressure Drop Caused by the Screen Blockage Rate in a Membrane Strainer
by Inhong Min, Jongwoong Choi, Gwangjae Kim and Hyunsik Jo
Processes 2024, 12(4), 831; https://doi.org/10.3390/pr12040831 - 19 Apr 2024
Cited by 3 | Viewed by 4137
Abstract
Autostrainer is used for the purpose of debris removal in order to increase the efficiency of the heat exchanger by taking the required raw water as a heat source for the pre-cooling hydrothermal system. During the operation of the autostrainer, a pressure drop [...] Read more.
Autostrainer is used for the purpose of debris removal in order to increase the efficiency of the heat exchanger by taking the required raw water as a heat source for the pre-cooling hydrothermal system. During the operation of the autostrainer, a pressure drop occurs due to the blockage of the screen in the autostrainer. As a result, the resistance of the pipe network for the intake system is changed, and the operating efficiency point of the pump, valve, heat exchanger, etc., is altered. By calculating the system resistance taking into account the pressure drop caused by the blockage rate of the screen in the autostrainer, the optimum operating efficiency can be expected when the intake system such as a pump, valve or heat exchanger, etc. is constructed. In this study, Computational Fluid Dynamics (CFD) was used to construct a scenario in which screen blockage may occur, predicting pressure drop for the slot cross-section of the screen in the autostrainer to derive a resistance coefficient value. The resistance coefficient value was applied to the porous region corresponding to the screen in the autostrainer’s 3D shape and compared with the experimental value for the pressure drop and headloss coefficient. By predicting the pressure drop for the autostrainer’s screen blockage rate of 0% to 50%, the coefficient of headloss required for the design of the intake system was calculated. Additionally, in order to predict the debris removal rate, which is the original role of the autostrainer, the debris was assumed to be particles, and sedimentation rate was predicted according to the size and weight of the particles. Building on this, when introducing the autostrainer used in pre-cooling into the membrane filtration process, due to the pressure loss caused by the inflow of debris during the use of the autostrainer, this study aims to utilize Computational Fluid Dynamics (CFD) to derive the head loss coefficients according to the screen blockage rate, and use these coefficients to calculate the system’s resistance curve. Additionally, in this study, the term “autostrainer” is used instead of the term “membrane strainer” to align with more popular terminology. Full article
(This article belongs to the Section Materials Processes)
Show Figures

Figure 1

13 pages, 2431 KB  
Article
Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis
by Daniela Toma, Rodica Toganel, Amalia Fagarasan, Manuela Cucerea, Dorottya Gabor-Miklosi, Andreea Cerghit-Paler, Diana-Ramona Iurian, Horea Gozar, Elena Moldovan, Mihaela Iancu and Liliana Gozar
Int. J. Environ. Res. Public Health 2022, 19(14), 8620; https://doi.org/10.3390/ijerph19148620 - 15 Jul 2022
Cited by 5 | Viewed by 2330
Abstract
Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal [...] Read more.
Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal and regional strain measurements. A total of 127 full-term newborns were examined to be included in the study, of which 103 were analyzed. We used two-dimensional acquisitions from apical four-chamber view of both ventricles and analyzed the autostrain function offline. We obtained interobserver agreement between the two observers ranging from good to excellent for all speckle-tracking parameters except for the strain of the medial portion of the left ventricle (LV) lateral wall and the strain measured on the basal portion of the inter-ventricular septum, which reflected a fair interobserver reproducibility (ICC = 0.52, 95% IC: 0.22–0.72 and ICC = 0.43, 95% IC: 0.12–0.67, respectively). The reference values obtained for the LV peak longitudinal strain were between −24.65 and −14.62, those for the right ventricle (RV) free wall were from −28.69 to −10.68, and those for the RV global four-chamber were from −22.30 to −11.37. In conclusion, two-dimensional peak longitudinal LV and RV strains are reproducible with good to excellent agreement and may represent a possible alternative for the cardiac assessment of healthy newborns in the clinical practice. Full article
(This article belongs to the Special Issue New Advance in Cardiovascular Care)
Show Figures

Figure 1

Back to TopTop