Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = Ferrlecit

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 1127 KB  
Article
Determination of Non-Transferrin Bound Iron, Transferrin Bound Iron, Drug Bound Iron and Total Iron in Serum in a Rats after IV Administration of Sodium Ferric Gluconate Complex by Simple Ultrafiltration Inductively Coupled Plasma Mass Spectrometric Detection
by Murali K. Matta, Christopher R. Beekman, Adarsh Gandhi, Suresh Narayanasamy, Christopher D. Thomas, Adil Mohammad, Sharron Stewart, Lin Xu, Ashok Chockalingam, Katherine Shea, Vikram Patel and Rodney Rouse
Nanomaterials 2018, 8(2), 101; https://doi.org/10.3390/nano8020101 - 11 Feb 2018
Cited by 12 | Viewed by 8369
Abstract
A rapid, sensitive and specific ultrafiltration inductively-coupled plasma mass spectrometry method was developed and validated for the quantification of non-transferrin bound iron (NTBI), transferrin bound iron (TBI), drug bound iron (DI) and total iron (TI) in the same rat serum sample after intravenous [...] Read more.
A rapid, sensitive and specific ultrafiltration inductively-coupled plasma mass spectrometry method was developed and validated for the quantification of non-transferrin bound iron (NTBI), transferrin bound iron (TBI), drug bound iron (DI) and total iron (TI) in the same rat serum sample after intravenous (IV) administration of iron gluconate nanoparticles in sucrose solution (Ferrlecit®). Ultrafiltration with a 30 kDa molecular cut-off filter was used for sample cleanup. Different elution solvents were used to separate each form of iron from sample serum. Isolated fractions were subjected to inductively-coupled mass spectrometric analysis after microwave digestion in 4% nitric acid. The reproducibility of the method was evaluated by precision and accuracy. The calibration curve demonstrated linearity from 5–500 ng/mL with a regression (r2) of more than 0.998. This method was effectively implemented to quantify rat pharmacokinetic study samples after intravenous administration of Ferrlecit®. The method was successfully applied to a pharmacokinetic (PK) study of Ferrlecit in rats. The colloidal iron followed first order kinetics with half-life of 2.2 h and reached background or pre-dose levels after 12 h post-dosing. The drug shown a clearance of 0.31 mL/min/kg and volume of distribution of 0.05 L/kg. 19.4 ± 2.4 mL/h/kg. Full article
(This article belongs to the Special Issue Pharmaceutical Nanotechnology)
Show Figures

Figure 1

18 pages, 2697 KB  
Article
Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: Physicochemical Characterization
by Dajun Sun, Rodney Rouse, Vikram Patel, Yong Wu, Jiwen Zheng, Alokita Karmakar, Anil K. Patri, Priyanka Chitranshi, David Keire, Jia Ma and Wenlei Jiang
Nanomaterials 2018, 8(1), 25; https://doi.org/10.3390/nano8010025 - 5 Jan 2018
Cited by 19 | Viewed by 13535
Abstract
The objective of this study was to evaluate physicochemical equivalence between brand (i.e., Ferrlecit) and generic sodium ferric gluconate (SFG) in sucrose injection by conducting a series of comparative in vitro characterizations using advanced analytical techniques. The elemental iron and carbon content, thermal [...] Read more.
The objective of this study was to evaluate physicochemical equivalence between brand (i.e., Ferrlecit) and generic sodium ferric gluconate (SFG) in sucrose injection by conducting a series of comparative in vitro characterizations using advanced analytical techniques. The elemental iron and carbon content, thermal properties, viscosity, particle size, zeta potential, sedimentation coefficient, and molecular weight were determined. There was no noticeable difference between brand and generic SFG in sucrose injection for the above physical parameters evaluated, except for the sedimentation coefficient determined by sedimentation velocity analytical ultracentrifugation (SV-AUC) and molecular weight by asymmetric field flow fractionation-multi-angle light scattering (AFFF-MALS). In addition, brand and generic SFG complex products showed comparable molecular weight distributions when determined by gel permeation chromatography (GPC). The observed minor differences between brand and generic SFG, such as sedimentation coefficient, do not impact their biological activities in separate studies of in vitro cellular uptake and rat biodistribution. Coupled with the ongoing clinical study comparing the labile iron level in healthy volunteers, the FDA-funded post-market studies intended to illustrate comprehensive surveillance efforts ensuring safety and efficacy profiles of generic SFG complex in sucrose injection, and also to shed new light on the approval standards on generic parenteral iron colloidal products. Full article
(This article belongs to the Special Issue Pharmaceutical Nanotechnology)
Show Figures

Figure 1

15 pages, 2868 KB  
Article
Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: Biodistribution after Intravenous Dosing in Rats
by Christopher R. Beekman, Murali K. Matta, Christopher D. Thomas, Adil Mohammad, Sharron Stewart, Lin Xu, Ashok Chockalingam, Katherine Shea, Dajun Sun, Wenlei Jiang, Vikram Patel and Rodney Rouse
Nanomaterials 2018, 8(1), 10; https://doi.org/10.3390/nano8010010 - 28 Dec 2017
Cited by 10 | Viewed by 7127
Abstract
Relative biodistribution of FDA-approved innovator and generic sodium ferric gluconate (SFG) drug products was investigated to identify differences in tissue distribution of iron after intravenous dosing to rats. Three equal cohorts of 42 male Sprague-Dawley rats were created with each cohort receiving one [...] Read more.
Relative biodistribution of FDA-approved innovator and generic sodium ferric gluconate (SFG) drug products was investigated to identify differences in tissue distribution of iron after intravenous dosing to rats. Three equal cohorts of 42 male Sprague-Dawley rats were created with each cohort receiving one of three treatments: (1) the innovator SFG product dosed intravenously at a concentration of 40 mg/kg; (2) the generic SFG product dosed intravenously at a concentration of 40 mg/kg; (3) saline dosed intravenously at equivalent volume to SFG products. Sampling time points were 15 min, 1 h, 8 h, 1 week, two weeks, four weeks, and six weeks post-treatment. Six rats from each group were sacrificed at each time point. Serum, femoral bone marrow, lungs, brain, heart, kidneys, liver, and spleen were harvested and evaluated for total iron concentration by ICP-MS. The ICP-MS analytical method was validated with linearity, range, accuracy, and precision. Results were determined for mean iron concentrations (µg/g) and mean total iron (whole tissue) content (µg/tissue) for each tissue of all groups at each time point. A percent of total distribution to each tissue was calculated for both products. At any given time point, the overall percent iron concentration distribution did not vary between the two SFG drugs by more than 7% in any tissue. Overall, this study demonstrated similar tissue biodistribution for the two SFG products in the examined tissues. Full article
(This article belongs to the Special Issue Pharmaceutical Nanotechnology)
Show Figures

Figure 1

12 pages, 7499 KB  
Article
Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: In Vitro Cellular Uptake
by Min Wu, Dajun Sun, Katherine Tyner, Wenlei Jiang and Rodney Rouse
Nanomaterials 2017, 7(12), 451; https://doi.org/10.3390/nano7120451 - 15 Dec 2017
Cited by 6 | Viewed by 7711
Abstract
Iron deficiency anemia is a common clinical consequence for people who suffer from chronic kidney disease, especially those requiring dialysis. Intravenous (IV) iron therapy is a widely accepted safe and efficacious treatment for iron deficiency anemia. Numerous IV iron drugs have been approved [...] Read more.
Iron deficiency anemia is a common clinical consequence for people who suffer from chronic kidney disease, especially those requiring dialysis. Intravenous (IV) iron therapy is a widely accepted safe and efficacious treatment for iron deficiency anemia. Numerous IV iron drugs have been approved by U.S. Food and Drug Administration (FDA), including a single generic product, sodium ferric gluconate complex in sucrose. In this study, we compared the cellular iron uptake profiles of the brand (Ferrlecit®) and generic sodium ferric gluconate (SFG) products. We used a colorimetric assay to examine the amount of iron uptake by three human macrophage cell lines. This is the first published study to provide a parallel evaluation of the cellular uptake of a brand and a generic IV iron drug in a mononuclear phagocyte system. The results showed no difference in iron uptake across all cell lines, tested doses, and time points. The matching iron uptake profiles of Ferrlecit® and its generic product support the FDA’s present position detailed in the draft guidance on development of SFG complex products that bioequivalence can be based on qualitative (Q1) and quantitative (Q2) formulation sameness, similar physiochemical characterization, and pharmacokinetic bioequivalence studies. Full article
(This article belongs to the Special Issue Pharmaceutical Nanotechnology)
Show Figures

Figure 1

Back to TopTop