21 pages, 1929 KB  
Article
Clinical Validation of Respiratory Rate Estimation Using Acoustic Signals from a Wearable Device
by Rawan S. Abdulsadig, Nikesh Devani, Sukhpreet Singh, Zaibaa Patel, Renard Xaviero Adhi Pramono, Swapna Mandal and Esther Rodriguez-Villegas
J. Clin. Med. 2024, 13(23), 7199; https://doi.org/10.3390/jcm13237199 - 27 Nov 2024
Cited by 5 | Viewed by 4105
Abstract
Objectives: Respiratory rate (RR) is a clinical measure of breathing frequency, a vital metric for clinical assessment. However, the recording and documentation of RR are considered to be extremely poor due to the limitations of the current approaches to measuring RR, including [...] Read more.
Objectives: Respiratory rate (RR) is a clinical measure of breathing frequency, a vital metric for clinical assessment. However, the recording and documentation of RR are considered to be extremely poor due to the limitations of the current approaches to measuring RR, including capnography and manual counting. We conducted a validation of the automatic RR measurement capability of AcuPebble RE100 (Acurable, London, UK) against a gold-standard capnography system and a type-III cardiorespiratory polygraphy system in two independent prospective and retrospective studies. Methods: The experiment for the prospective study was conducted at Imperial College London. Data from AcuPebble RE100 (Acurable, London, UK) and the reference capnography system (Capnostream™35, Medtronic, Minneapolis, MN, USA) were collected simultaneously from healthy volunteers. The data from a previously published study were used in the retrospective study, where the patients were recruited consecutively from a standard Obstructive Sleep Apnea (OSA) diagnostic pathway in a UK hospital. Overnight data during sleep were collected using the AcuPebble SA100 (Acurable, London, UK) sensor and a type-III cardiorespiratory polygraphy system (Embletta MPR Sleep System, Natus Medical, Pleasanton, CA, USA) at the patients’ homes. Data from 15 healthy volunteers were used in the prospective study. For the retrospective study, 150 consecutive patients had been referred for OSA diagnosis and successfully completed the study. Results: The RR output of AcuPebble RE100 (Acurable, London, UK) was compared against the reference device in terms of the Root Mean Squared Deviation (RMSD), mean error, and standard deviation (SD) of the difference between the paired measurements. In both the prospective and retrospective studies, the AcuPebble RE100 algorithms provided accurate RR measurements, well within the clinically relevant margin of error, typically used by FDA-approved respiratory rate monitoring devices, with the RMSD under three breaths per minute (BPM) and mean errors of 1.83 BPM and 1.4 BPM, respectively. Conclusions: The evaluation results provide evidence that AcuPebble RE100 (Acurable, London, UK) algorithms produce reliable results and are hence suitable for overnight monitoring of RR. Full article
(This article belongs to the Section Respiratory Medicine)
Show Figures

Figure 1

12 pages, 1958 KB  
Article
Validation of Tracheal Sound-Based Respiratory Effort Monitoring for Obstructive Sleep Apnoea Diagnosis
by Mireia Muñoz Rojo, Renard Xaviero Adhi Pramono, Nikesh Devani, Matthew Thomas, Swapna Mandal and Esther Rodriguez-Villegas
J. Clin. Med. 2024, 13(12), 3628; https://doi.org/10.3390/jcm13123628 - 20 Jun 2024
Cited by 2 | Viewed by 2559
Abstract
Background: Respiratory effort is considered important in the context of the diagnosis of obstructive sleep apnoea (OSA), as well as other sleep disorders. However, current monitoring techniques can be obtrusive and interfere with a patient’s natural sleep. This study examines the reliability of [...] Read more.
Background: Respiratory effort is considered important in the context of the diagnosis of obstructive sleep apnoea (OSA), as well as other sleep disorders. However, current monitoring techniques can be obtrusive and interfere with a patient’s natural sleep. This study examines the reliability of an unobtrusive tracheal sound-based approach to monitor respiratory effort in the context of OSA, using manually marked respiratory inductance plethysmography (RIP) signals as a gold standard for validation. Methods: In total, 150 patients were trained on the use of type III cardiorespiratory polygraphy, which they took to use at home, alongside a neck-worn AcuPebble system. The respiratory effort channels obtained from the tracheal sound recordings were compared to the effort measured by the RIP bands during automatic and manual marking experiments. A total of 133 central apnoeas, 218 obstructive apnoeas, 263 obstructive hypopneas, and 270 normal breathing randomly selected segments were shuffled and blindly marked by a Registered Polysomnographic Technologist (RPSGT) in both types of channels. The RIP signals had previously also been independently marked by another expert clinician in the context of diagnosing those patients, and without access to the effort channel of AcuPebble. The classification achieved with the acoustically obtained effort was assessed with statistical metrics and the average amplitude distributions per respiratory event type for each of the different channels were also studied to assess the overlap between event types. Results: The performance of the acoustic effort channel was evaluated for the events where both scorers were in agreement in the marking of the gold standard reference channel, showing an average sensitivity of 90.5%, a specificity of 98.6%, and an accuracy of 96.8% against the reference standard with blind expert marking. In addition, a comparison using the Embla Remlogic 4.0 automatic software of the reference standard for classification, as opposed to the expert marking, showed that the acoustic channels outperformed the RIP channels (acoustic sensitivity: 71.9%; acoustic specificity: 97.2%; RIP sensitivity: 70.1%; RIP specificity: 76.1%). The amplitude trends across different event types also showed that the acoustic channels exhibited a better differentiation between the amplitude distributions of different event types, which can help when doing manual interpretation. Conclusions: The results prove that the acoustically obtained effort channel extracted using AcuPebble is an accurate, reliable, and more patient-friendly alternative to RIP in the context of OSA. Full article
(This article belongs to the Section Respiratory Medicine)
Show Figures

Figure 1

14 pages, 1373 KB  
Article
Validation of a Wearable Medical Device for Automatic Diagnosis of OSA against Standard PSG
by Jesus Sanchez Gomez, Renard Xaviero Adhi Pramono, Syed Anas Imtiaz, Esther Rodriguez-Villegas and Agustin Valido Morales
J. Clin. Med. 2024, 13(2), 571; https://doi.org/10.3390/jcm13020571 - 19 Jan 2024
Cited by 18 | Viewed by 4427
Abstract
Study objective: The objective of this study was to assess the accuracy of automatic diagnosis of obstructive sleep apnea (OSA) with a new, small, acoustic-based, wearable technology (AcuPebble SA100), by comparing it with standard type 1 polysomnography (PSG) diagnosis. Material and methods: This [...] Read more.
Study objective: The objective of this study was to assess the accuracy of automatic diagnosis of obstructive sleep apnea (OSA) with a new, small, acoustic-based, wearable technology (AcuPebble SA100), by comparing it with standard type 1 polysomnography (PSG) diagnosis. Material and methods: This observational, prospective study was carried out in a Spanish hospital sleep apnea center. Consecutive subjects who had been referred to the hospital following primary care suspicion of OSA were recruited and underwent in-laboratory attended PSG, together with the AcuPebble SA100 device simultaneously overnight from January to December 2022. Results: A total of 80 patients were recruited for the trial. The patients had a median Epworth scoring of 10, a mean of 10.4, and a range of 0–24. The mean AHI obtained with PSG plus sleep clinician marking was 23.2, median 14.3 and range 0–108. The study demonstrated a diagnostic accuracy (based on AHI) of 95.24%, sensitivity of 92.86%, specificity of 97.14%, positive predictive value of 96.30%, negative predictive value of 94.44%, positive likelihood ratio of 32.50 and negative likelihood ratio of 0.07. Conclusions: The AcuPebble SA100 (EU) device has demonstrated an accurate automated diagnosis of OSA in patients undergoing in-clinic sleep testing when compared against the gold-standard reference of in-clinic PSG. Full article
(This article belongs to the Section Clinical Research Methods)