Next Article in Journal
Non-Destructive Estimation of Moisture Percentage in Fired Red Brick Using Digital Image Processing and Artificial Intelligence
Previous Article in Journal
Optimization Using Central Composite Design of the Response Surface Methodology for the Compressive Strength of Alkali-Activated Material from Rice Husk Ash
Previous Article in Special Issue
Impact of Freeze–Thaw Cycling on the Mechanical and Durability Properties of Rapid Repair-Based Overlay Systems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Comparison of the Corrosion Resistance of Fiber-Reinforced Concrete with Steel and Polypropylene Fibers in an Acidic Environment

by
Sergii Kroviakov
1,
Vitalii Kryzhanovskyi
2,* and
Daria Hedulian
1
1
Department of Highways and Airfields, Odessa State Academy of Civil Engineering and Architecture, Didrihsona Street 4, 65029 Odessa, Ukraine
2
Department of Buidilng Materials, TU Dortmund, 44227 Dortmund, Germany
*
Author to whom correspondence should be addressed.
Constr. Mater. 2025, 5(1), 6; https://doi.org/10.3390/constrmater5010006
Submission received: 14 December 2024 / Revised: 21 January 2025 / Accepted: 22 January 2025 / Published: 1 February 2025
(This article belongs to the Special Issue Modelling and Analysis of Concrete Degradation)

Abstract

:
Rigid road pavements and industrial floors are not only subjected to moving traffic loads, but can also be exposed to environmental influences such as acid attack. The strength and corrosion resistance of fiber-reinforced concrete with steel fibers (15–25 kg/m3) and polypropylene fibers (2–3 kg/m3) in an acidic environment were compared. The influence of the amount and type of dispersed reinforcement on water absorption and the volume of permeable voids, which in turn characterizes the durability of fiber-reinforced concrete under the action of acids, was determined. The change in the compressive strength of the studied fiber-reinforced concrete after 12 months of exposure in an acidic environment was studied. At low dosages of fibers (15 kg/m3 for steel and 2 kg/m3 for polypropylene fibers), dispersed reinforcement has little effect on the corrosion resistance of concrete. In turn, the decrease in the compressive strength of concrete without fibers after 12 months of aging in acid medium led to a reduction in the design class of the concrete from C25/30 to C20/25. At a higher consumption of dispersed reinforcement (25–30 kg/m3 of steel fiber and 2.5–3.0 kg/m3 of polypropylene fiber), fiber-reinforced concrete had a higher corrosion resistance while maintaining the design compressive strength class C25/30. Structural changes in fiber-reinforced concrete after aging in an acidic environment were determined by X-ray diffraction analysis and compared with samples aged in water. It has been experimentally confirmed that the efficiency of polypropylene fibers in an acidic environment is not lower than that of steel fibers. However, the use of polypropylene fibers is economically advantageous.

1. Introduction

Highways and industrial floors are an integral part of industrial construction. They are critical structures that contribute to the uniform distribution of moving and static loads on the subgrade soils. According to the principle of mechanical operation, they represent a beam on an elastic base. Fiber concrete is widely used to ensure the high-performance characteristics of road pavements and industrial floors [1,2,3,4,5,6,7,8,9].
Such materials are a family of concrete composites, which can contain dispersed fibers from different materials (steel, polypropylene, basalt, glass, carbon, kevlar, etc.) that form a spatial reinforcing framework across the entire cross-section of the structure. Fiber concretes have high tensile and flexural strength [10,11,12,13,14,15], crack resistance [16,17], frost resistance [18,19,20,21] and low abrasion resistance [22,23], which is very important for floor structures and road pavements.
An additional problem in the operation of industrial floors is the exposure to various chemicals at the respective industry facilities, in particular acids. In the case of road rigid pavements, subgrade soils with high amounts of SO42− sulfates and their presence in the infiltration water of the surrounding area can pose such a hazard [24,25,26,27,28].
In the study of corrosion resistance of ultra-high-performance concrete based on ordinary cement, with steel fibers of 13 mm length and 0.2 mm diameter, there was no negative effect of increasing the amount of fiber up to 2% by the volume of concrete. The compressive strength remained at 130 MPa after 1 year of curing in an acidic environment [29]. The authors of [30] noted an increase in the corrosion resistance of fiber concrete when using 0.15% polypropylene fibers with a length of 12 mm and a diameter of 0.03 mm. Increasing the fiber consumption to 0.3% did not improve the resistance of the concrete in an aggressive environment. The investigated dispersion-reinforced concretes were produced on the basis of ordinary cement; the compressive strength at the age of 28 days was 60 MPa. Fiber-reinforced concretes produced using ordinary cement and propylene fibers with a length of 19 mm and diameters of 0.03 mm and 0.1 mm, as well as a length of 50 mm and a diameter of 0.8 mm were moistened and dried in a 10% sodium sulfate solution. The holding period was 5 months (3 days of humidification and 4 days of drying—1 cycle). The positive influence of polypropylene fiber on corrosion resistance was found, and the greater efficiency of the combined fiber reinforcement of different lengths was also noted. The compressive strength of dispersion-reinforced concretes at the age of 28 days was not less than 40 MPa [31]. In [32], the effectiveness of dispersed reinforcement with different types of fibers on the fracture behavior of fiber concretes in aggressive environment is indicated. This was achieved by increasing the crack resistance and, as a consequence, increasing the time of further failure compared to control concrete samples without fibers. Certain modifications of fiber concrete with a steel filament consumption of 2% (with a length of 50 mm and a diameter of 2 mm) kept for one month in a 1% sulfuric acid solution shows a loss of the concrete’s compressive strength not more than 0.32%, with a weight loss not more than 0.2%. The same fiber concrete composition after exposure to a 1% hydrochloric acid solution had a compressive strength loss of 0.7% and a weight loss of 0.23% [33]. Using experimental and statistical modeling techniques, the optimum amount of steel and polypropylene fiber for acid resistance (to H2SO4 and Na2SO4 solutions) was determined. In order to maintain the balance of compressive strength with minimum mass loss, it is recommended to use 0.04% of steel fibers of a 30 mm length and a 0.9 mm diameter in combination with 0.23% of polypropylene fibers of a 40 mm length and a 0.75 mm diameter [34]. Meanwhile, one study [35] reported the effectiveness of 0.25% of polypropylene fibers and 1% of steel fibers. Researchers [36] have emphasized the effectiveness of the fiber reinforcement of concrete in terms of increasing the resistance of airfield pavements after exposure to defrosting agents up to 70%. The authors of [37] point out the necessity of observing the technological process of fiber concrete preparation to resist the effects of chlorides. The clumping of the fibers used leads to an increase in the pore space in the concrete body, which leads to a decrease in strength and durability characteristics. The use of 12 mm long polypropylene fibers in the amount of 1 kg/m3 contributed to increasing the resistance of fiber concrete under acid attack [38]. Researchers [39] have emphasized the positive effect of introducing steel fibers into the concrete mixture to resist acid corrosion. Microstructural analysis confirms the densification of the microstructure of the investigated concretes, based on which the pore structure of fiber concretes is improved and their resistance to acid attack is increased. The use of 1% of polypropylene fibers with a length of 30 mm contributed to an increase in resistance to sulfate corrosion of fiber concrete up to 54% with a compressive strength increase from 25 to 35 MPa. In a study of the flexural characteristics of steel fiber concrete, there was a negative effect of increasing the amount of steel fibers of a length of 35 mm up to 40 kg/m3 of concrete. A decrease in the flexural strength of up to 65% was observed [40].
As can be seen from the analysis of the literature sources, only the geometric characteristics of the applied fibers were varied in the conducted experiments. There is no comparative analysis of polypropylene and steel fibers in terms of obtaining concrete of the same strength class based on the basic composition. It is notable that in all of the processed sources, fiber concretes were produced using Type I cement.
Accordingly, the aim of the authors was to compare the effect of steel and polypropylene fibers on the strength and structural changes in fiber-reinforced concrete based on Type II cement after 1 year of exposure to an acidic environment (pH = 3). This study is a continuation of the experiment [41] and provides a more complete picture in terms of the durability of dispersion-reinforced concretes for rigid road pavements and industrial floors. Such a direct comparison of the resistance to aggressive environments of similar concrete compositions with competing types of fiber reinforcement is of economic and environmental significance, as well as being important from a practical application point of view.

2. Materials and Methods

The following components were used in the production of fiber-reinforced concrete: Portland cement CEM II/A-S 42.5 R [42,43] produced by CRH Ukraine (Podilsky Cement PJSC, Podilsk, Ukraine), crushed granite breakstone of a 5–20 mm fraction [44,45], natural quartz sand of a 0–2 mm fraction [44,46], the water-reducing admixture MC-PowerFlow 3200 manufactured by MC-Bauchemie, Bottrop, Germany [47,48], steel hooked-end fibers (SFs) [49,50] produced by Stalkanat-Silur, Odessa, Ukraine, and polypropylene fibers (PFs) “Baumesh” [51,52] produced by Bautech-Ukraine, Odessa, Ukraine. The appearance of the fibers is shown in Figure 1, the characteristics of the fibers are given in Table 1.
Table 2 shows the compositions of the investigated disperse fiber-reinforced concretes according to [41].
Since a constant W/C = 0.5 was chosen for all the compositions under study within the framework of the experiment, the design workability S4 (slump 16–21 cm) [53,54] was achieved by changing the amount of plasticizer. As can be seen from Table 2, when using SFs, it is necessary to increase the dosage of plasticizer by 7% compared to the CC composition. In turn, the compositions of fiber concretes with PFs require an increase in the amount of plasticizer up to 20% in relation to the CC composition. This is explained by the large amount of PFs despite the lower dosage compared to SFs.
At a design age of 28 days, all the tested concretes conformed to compressive strength class C25/30 [55]. It is worth noting the equal effect of PFs and SFs on the flexural strength of concrete. Therefore, despite the lower dosage of PFs in the studied compositions, in the range of 2–3 kg/m3, in comparison with the consumption of SFs at 15–25 kg/m3, the flexural strength at the age of 28 days was in the range from 4.45 to 4.75 MPa [41]. It should be noted that flexural strength is an important quality indicator for concrete structures that are being operated in an acidic environment, as it largely determines the crack resistance of the material [56,57]. Under the influence of an aggressive acidic environment, the destruction of concrete as a composite material occurs mainly due to the development of cracks [58].

2.1. Water Adsorption and Volume of Permeable Voids

The permeability of concretes and fiber concretes plays an important role in their durability. Low permeability increases the resistance of concretes to moisture migration, which increases the protection against sulfate attack [59,60,61]. The test was carried out according to the methodology of [62]. For each studied composition from Table 2, six cubes of 10 × 10 × 10 cm were produced. The samples were cured in a climatic chamber (t = 20 ± 2 °C, relative humidity 65 ± 5%) for 28 days [63,64]. The specimens were then dried to a constant mass (A) for 24 h at 105 °C. The next step was to saturate the samples in 21 °C water for 48 h with the fixation of their weight (B), followed by boiling for 5 h. Subsequently, the specimens were cooled for 14 h to a temperature of 25 °C. After removing the moisture with a cloth, the mass of the sample was recorded (C). Then, the apparent mass of the samples suspended on a wire in water was measured (D). At the end, the water absorption was calculated according to Formula (1) and the volume of permeable voids was calculated according to Formula (2):
Water adsorption, % = [(B – A)/A] × 100
Volume of permeable pore space, % = (C − A)/(C − D) × 100

2.2. Corrosion Resistance

The determination of the corrosion resistance of dispersion-reinforced concretes was carried out after 12 months of acid exposure (pH = 3), which was obtained by mixing sulfuric acid and distilled water. Twelve 10 × 10 × 10 cm cube specimens were manufactured for each batch of fiber concretes under study. For the first 28 days of hardening, the specimens were stored in a normal curing chamber (t = 20 ± 2 °C, relative humidity 65 ± 5%) [63,64]. Then, the samples were divided into two series (6 specimens in each). The first series was cured in water and the second series in an acidic environment (pH = 3) [65]. Throughout the tests, visual evaluation of the specimens for defects was performed. After 6 and 12 months of exposure, the change in mass of the samples and their compressive strength were determined. Figures of the samples aged in water and in an acidic environment are shown in [41].

2.3. X-Ray Analysis

To determine the microstructural changes in the studied dispersion-reinforced concretes after exposure to an acidic medium, X-ray diffraction analysis was carried out. Diffractograms of the cement–sand matrix samples were recorded using an ElvaX Light SDD spectrometer (range 10–105° 2θ, using CuKα1 radiation (λ = 1.5406 Å) and operating at 40 kV and 15 mA).
The general flowchart of the conducted research is shown in Figure 2.

3. Research Results and Analysis

3.1. Water Adsorption and Volume of Permeable Voids

Figure 3 reflects the data on the water absorption and volume of the permeable voids of the investigated fiber concretes.
The data in Figure 3 show the positive effect of the introduction of dispersed reinforcing fibers of both types on the reduction in water absorption and the volume of permeable voids. The decreased water absorption of the fiber concretes ensures their lower open porosity, which is in agreement with previous studies [66,67]. Also, from the diagram in Figure 3b, the better effect of PFs in terms of reducing the volume of permeable voids can be seen. This can be explained by the higher quantitative content of PFs compared SFs, which prevents moisture migration into the body of the fiber concrete.

3.2. Corrosion Resistance

As noted above, the corrosion resistance of fiber-reinforced concrete in an acidic environment was determined by comparing the properties of samples kept in water or in an acidic environment of pH = 3 [65]. The compressive strength of the studied fiber concrete and the CC composition after 6 months [41] and 12 months of exposure, as well as the amount of reduction in the concrete’s compressive strength in an acidic environment, are shown in Table 3.
After 12 months of exposure to an acidic environment, individual corrosion-induced surface defects were observed on the samples, as shown in Figure 4. However, the overall geometric dimensions of the samples with both fiber types did not change.
The diagrams shown in Figure 5 were drawn using the data from Table 3. The analysis of the data allows us to conclude that, after 6 and 12 months of water curing, the effect of dispersed steel and polypropylene fiber reinforcement on the compressive strength of the concrete is similar to the effect of the fibers on its strength at the standard age.
Under the influence of an acidic environment, the nature of the fibers’ effect on changes to the concrete’s compressive strength. Based on this, in a non-aggressive water environment, SFs showed a slightly higher efficiency, while after aging in an acidic environment, the degree of influence of different fiber types on the concrete’s compressive strength actually leveled out. It is also notable that, in an acidic environment, at low dosages of fibers (15 kg/m3 for SFs and 2 kg/m3 for PFs), dispersed reinforcement has a small impact on compressive strength and does not increase the corrosion resistance of the concrete. At higher amounts of fibers (20–25 kg/m3 for SFs, and 2.5–3.0 kg/m3 for PFs), the studied fiber-reinforced concrete has a higher corrosion resistance. It is also remarkable that the loss of compressive strength after the first 6 months of exposure to aggressive environments is more sensitive than in the next 6 months for the CC composition and the compositions with dispersed reinforcement.
The positive impact of dispersed reinforcement on corrosion resistance in an acidic environment is explained by the fact that, as a result of the reaction of concrete components with acids, calcium carbonate CaCO3 is formed, which is insoluble in water. Over time, some of the calcium carbonate can turn into ettringite (a highly insoluble calcium hydrosulfoaluminate) [68]. Accordingly, the accumulation of calcium carbonate in pores and microcracks leads to concrete cracking [56,68,69]. Such processes are confirmed, in particular, by the fact that after 6 months of exposure to an acidic environment, the mass of specimens differed from the mass of similar specimens aged in water by no more than 1.9% (Table 4) [41]. However, after 12 months of aging, the mass of the samples in an acidic environment due to the appearance of individual defects was less than the mass of similar samples aged in water by up to 2.3% for dispersion-reinforced concrete and 7.5% for the CC composition.
The above-described main mechanism of the corrosion failure of concrete in an acidic environment was also confirmed by a comparative X-ray diffraction analysis of the cement–sand matrix of concrete samples with a CC composition after 12 months of aging in water and an acidic environment (Figure 6).
It was found that the main hydrate phases in the matrix are portlandite and calcite. Aggregates are represented by quartz and albite (feldspar). In the samples aged in an acidic environment, the formation of ettringite was established (Figure 6b). The most probable reaction is the interaction of acid with calcium carbonate, a product of the carbonization of calcium hydroxide: CaCO3 + H2SO4 = CaSO4·2H2O + H2CO3 (H2O + CO2). The next reaction is the formation of ettringite: C3AH6 + 3(CaSO4·2H2O) + 20H2O = C3A 3CaSO4·32H2O.
In other words, dispersed reinforcement with SFs and PFs contributes to increasing the corrosion resistance of concrete under conditions of the accumulation of hardly soluble compounds in its pores and microcracks, which cause internal stresses. Fiber helps redistribute these stresses, which inhibits the destruction of concrete as a composite material. A similar positive result from the use of dispersed reinforcement in aggressive environments was obtained, for example, in [58,68]. At the same time, the effectiveness of dispersed reinforcement significantly depends on the number of filaments, which should be rational for each type of fiber [68,69].

4. Conclusions

The paper analyses the changes in physical, mechanical and structural properties of fiber concrete for road pavements and industrial floors after 12 months of exposure in an aggressive acidic environment. The obtained experimental data make it possible to draw the following conclusions:
-
The use of dispersed reinforcement with both types of fibers reduces the water absorption of concrete by up to 30% and the volume of permeable voids by up to 11% in comparison with control concrete without dispersed reinforcement;
-
A low dosage of steel and polypropylene fibers (15 kg/m3 and 2 kg/m3) does not lead to an increase in the corrosion resistance of fiber concretes. For the effective operation of industrial floors and rigid road pavements, it is recommended to use steel fibers in the amount of 20–25 kg/m3 and polypropylene fibers from 2.5 to 3 kg/m3. At the same time, visual inspection showed the absence of geometrical changes in the specimens after sulfate exposure, and the obtained results of compressive strength confirmed the effectiveness of dispersed reinforcement in terms of maintaining the design class of the concrete as C20/25 even after 12 months of exposure to an aggressive environment;
-
The possible mechanism of resistance of the fiber concretes in an acid medium on the basis of strength indicators and X-ray phase analysis is described, and the scenario of microstructural changes in the investigated composites is proposed.
In general, regardless of the lower consumption of polypropylene fibers, their efficiency is not lower than that of steel fibers. This makes the use of polypropylene fibers cost-effective. In addition, the production of 2.5–3 kg of polypropylene fiber produces a smaller carbon footprint than the production of 20–25 kg of steel fiber.
A high corrosion resistance makes it possible to recommend fiber concretes with polypropylene fibers for industrial floors, road pavements and warehouses at enterprises associated with the use or production of substances creating an acidic environment, for example, at mineral fertilizer factories.
Further research is planned in order to study the corrosion resistance of road pavements and industrial floors with hybrid reinforcement using steel and polypropylene fibers. The aim will be to study not only compressive strength, but also flexural strength and abrasion resistance after acid attack, as these parameters determine the quality and operational reliability of these types of structures.

Author Contributions

Conceptualization, V.K. and S.K.; methodology, S.K., V.K. and D.H.; formal analysis, V.K. and S.K.; resources, V.K. and D.H.; data curation, D.H. and S.K.; writing—original draft preparation, S.K. and V.K.; writing—review and editing, S.K. and D.H.; visualization, S.K. and V.K.; supervision, S.K. and V.K.; project administration, D.H. and S.K.; funding acquisition, V.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data supporting this study are available from the author on request.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Lau, C.K.; Chegenizadeh, A.; Htut, T.N.S.; Nikraz, H. Performance of the Steel Fibre Reinforced Rigid Concrete Pavement in Fatigue. Buildings 2020, 10, 186. [Google Scholar] [CrossRef]
  2. Patil, R.R.; Katare, V.D. Application of Fiber Reinforced Cement Composites in Rigid Pavements: A review. Mater. Today Proc. 2023. [Google Scholar] [CrossRef]
  3. Kabashi, N.; Krasniqi, C.; Hadri, R.; Sadikaj, A. Effect of Fibre Reinforced Concrete and Behaviour in Rigid Pavement. Int. J. Struct. Civ. Eng. Res. 2018, 7, 29–33. [Google Scholar] [CrossRef]
  4. Suksawang, N.; Yohannes, D. Using Fiber Reinforced Concrete to Control Early-Age Shrinkage in Replacement Concrete Pavement. In Fibre Reinforced Concrete: Improvements and Innovations; Serna, P., Llano-Torre, A., Martí-Vargas, J.R., Navarro-Gregori, J., Eds.; BEFIB 2020. RILEM Bookseries; Springer Nature: Berlin, Germany, 2020; Volume 30, pp. 12–23. [Google Scholar] [CrossRef]
  5. Awad, R.; Barakat, S.; Leblouba, M.; Altoubat, S.; Maalej, M. Reliability-based Design of Fiber Reinforced Concrete Slabs-on-Ground in Flexure as per ACI 360. Structures 2022, 39, 207–217. [Google Scholar] [CrossRef]
  6. Alani, A.; Beckett, D.; Khosrowshahi, F. Mechanical Behaviour of a Steel Fibre Reinforced Concrete Ground Slab. Mag. Concr. Res. 2012, 64, 593–604. [Google Scholar] [CrossRef]
  7. Alsharie, H. Applications and Prospects of Fiber Reinforced Concrete in Industrial Floors. Open J. Civ. Eng. 2015, 5, 185–189. [Google Scholar] [CrossRef]
  8. Marushchak, U.; Sydor, N.; Braichenko, S.; Margal, I.; Soltysik, R. Modified Fiber Reinforced Concrete for Industrial Floors. In Proceedings of the IOP Conference Series: Materials Science and Engineering, Reliability and Durability of Railway Transport Engineering Structures and Buildings, Kharkiv, Ukraine, 20–22 November 2019; Volume 708. [Google Scholar] [CrossRef]
  9. Pombo, R.; Altamirano, M.G.; Giaccio, G.M.; Zerbino, R.L. Design and Execution of Floors on Ground and Industrial Pavements with Fibre Reinforced Concrete. In Fibre Reinforced Concrete: Improvements and Innovations II; Serna, P., Llano-Torre, A., Martí-Vargas, J.R., Navarro-Gregori, J., Eds.; BEFIB 2021. RILEM Bookseries, 36; Springer: Cham, Switzerland, 2021. [Google Scholar] [CrossRef]
  10. Dvorkin, L.; Konkol, J.; Marchuk, V.; Huts, A. Efficient, Fine-Grained Fly Ash Concrete Based on Metal and Basalt Fibers. Materials 2023, 16, 3969. [Google Scholar] [CrossRef] [PubMed]
  11. Kos, Z.; Kroviakov, S.; Mishutin, A.; Poltorapavlov, A. An Experimental Study on the Properties of Concrete and Fiber-Reinforced Concrete in Rigid Pavements. Materials 2023, 16, 5886. [Google Scholar] [CrossRef]
  12. Marushchak, U.; Sanytsky, M.; Korolko, S.; Shabatura, U.; Sydor, U. Development of Nanomodified Rapid Hardening Fiber reinforced Concretes for Special-purpose Facilities. East. Eur. J. Enterp. Technol. 2018, 2, 34–41. [Google Scholar] [CrossRef]
  13. Surianinov, M.; Andronov, V.; Otrosh, Y.; Makovkina, T.; Vasiukov, S. Concrete and Fiber Concrete Impact Strength. Mater. Sci. Forum 2020, 1006, 101–106. [Google Scholar] [CrossRef]
  14. Korneeva, I.; Neutov, S.; Suriyaninov, M. Experimental Studies of Fiber Concrete Creep. MATEC Web Conf. 2017, 116, 02021. [Google Scholar] [CrossRef]
  15. Spyridis, P.; Mellios, N. Tensile Performance of Headed Anchors in Steel Fiber Reinforced and Conventional Concrete in Uncracked and Cracked State. Materials 2022, 15, 1886. [Google Scholar] [CrossRef]
  16. Dong, S.; Wang, D.; Hui, E.; Gao, C.; Zhang, H.; Tan, Y. An Overview of the Application of Fiber-Reinforced Cementitious Composites in Spray Repair of Drainage Pipes. Buildings 2023, 13, 1119. [Google Scholar] [CrossRef]
  17. Kryzhanovskyi, V.; Umbach, C.; Orlowsky, J.; Middendorf, B.; Auras, M.; Grillich, P. Denkmalkonforme Instandsetzung der Beton-Glas-Fenster der St.-Mauritius-Kirche. Bautechnik 2024, 101, 299–308. [Google Scholar] [CrossRef]
  18. Mishutin, A.; Kroviakov, S.; Kryzhanovskyi, V.; Chintea, L. Fiber-reinforced Concrete for Rigid Road Pavements Modified with Polycarboxylate Admixture and Metakaolin. Adv. Civ. Archit. Eng. 2021, 12, 1–10. [Google Scholar] [CrossRef]
  19. Niu, D.; Gong, S.; Guo, B.; Cao, Z.; Wang, Y. Study on Frost Resistance of Steel-PVA Hybrid Fiber Concrete. In Advances in Frontier Research on Engineering Structures. Lecture Notes in Civil Engineering; Yang, Y., Ed.; Springer: Singapore, 2023; Volume 286, pp. 105–112. [Google Scholar] [CrossRef]
  20. Tan, Y.; Long, J.; Xiong, W.; Chen, X.; Zhao, B. Effects of Polypropylene Fibers on the Frost Resistance of Natural Sand Concrete and Machine-Made Sand Concrete. Polymers 2022, 14, 4054. [Google Scholar] [CrossRef] [PubMed]
  21. Kos, Ž.; Kroviakov, S.; Kryzhanovskyi, V.; Grynyova, I. Research of Strength, Frost Resistance, Abrasion Resistance and Shrinkage of Steel Fiber Concrete for Rigid Highways and Airfields Pavement Repair. Appl. Sci. 2022, 12, 1174. [Google Scholar] [CrossRef]
  22. Wu, F.; Yu, Q.; Chen, X. Effects of Steel Fibre Type and Dosage on Abrasion Resistance of Concrete Against Debris Flow. Cem. Concr. Compos. 2022, 134, 104776. [Google Scholar] [CrossRef]
  23. Kamel, O.A.; Abouhussien, A.A.; Hassan, A.A.; AbdelAleem, B.H. Assessment of Abrasion Resistance of Fiber-Reinforced Concrete at Cold Temperatures through Acoustic Emission Analysis. ACI Mater. J. 2023, 120, 41–54. [Google Scholar] [CrossRef]
  24. Seco, A.; del Castillo, J.M.; Perlot, C.; Marcelino-Sádaba, S.; Prieto, E.; Espuelas, S. Experimental Study of the Valorization of Sulfate Soils for Use as Construction Material. Sustainability 2022, 14, 6609. [Google Scholar] [CrossRef]
  25. Kampala, A.; Jitsangiam, P.; Pimraksa, K.; Chindaprasirt, P. An Investigation of Sulfate Effects on Compaction Characteristics and Strength Development of Cement-treated Sulfate Bearing Clay Subgrade. Road Mater. Pavement Des. 2021, 22, 2396–2409. [Google Scholar] [CrossRef]
  26. Adeleke, B.; Kinuthia, J.; Oti, J. Strength and Swell Performance of High-Sulphate Kaolinite Clay Soil. Sustainability 2020, 12, 10164. [Google Scholar] [CrossRef]
  27. Zhao, X.; Shen, A.; Guo, Y.; Li, P.; Lv, Z. Pavement Mechanic Response of Sulfate Saline Soil Subgrade Section Based on Fluid–structure Interaction Model. Int. J. Pavement Res. Technol. 2017, 10, 497–506. [Google Scholar] [CrossRef]
  28. Kowalska, M.; Grzesik, B.; Adamczyk, Z.; Nowak, J.; Konsek, A. Swelling of Sulfate-bearing Soil: A Case Study of A1 Highway Pavement Failure. Case Stud. Constr. Mater. 2023, 18, e02081. [Google Scholar] [CrossRef]
  29. Valcuende, M.; Lliso-Ferrando, J.R.; Ramón-Zamora, J.E.; Soto, J. Corrosion Resistance of Ultra-high performance Fibre- reinforced Concrete. Constr. Build. Mater. 2021, 306, 124914. [Google Scholar] [CrossRef]
  30. Alomayri, T.; Ali, B.; Raza, S.S.; Ahmed, H.; Hamad, M. Investigating the Effects of Polypropylene Fibers on the Mechanical Strength, Permeability, and Erosion Resistance of Freshwater and Seawater Mixed Concretes. J. Mar. Sci. Eng. 2023, 11, 1224. [Google Scholar] [CrossRef]
  31. Liang, N.; Mao, j.; Yan, R.; Liu, X.; Zhou, X. Corrosion Resistance of Multiscale Polypropylene Fiber-reinforced Concrete under Sulfate Attack. Case Stud. Constr. Mater. 2022, 16, e01065. [Google Scholar] [CrossRef]
  32. Naidu Gopu, G.; Joseph, S.A. Corrosion Behavior of Fiber-Reinforced Concrete—A Review. Fibers 2022, 10, 38. [Google Scholar] [CrossRef]
  33. Arivudamai, V.; Velkennedy, R. Acid Attack on Hybrid Fiber Reinforced High Strength Concrete with Manufactured Sand and Coconut Shell. J. Adv. Chem. 2017, 12, 5825–5828. [Google Scholar]
  34. Bankir, M.B.; Sevim, U.K. Performance Optimization of Hybrid Fiber Concretes against Acid and Sulfate Attack. J. Build. Eng. 2020, 32, 101443. [Google Scholar] [CrossRef]
  35. Somasekharaiah, H.M.; Shobha, M.S.; Mallikarjuna, H.M. Mechanical Properties and Acid Attack Test of Hybrid Fiber Reinforced High Performance Concrete for Fly Ash based Mineral Admixture. Mater. Today Proc. 2022, 51, 742–749. [Google Scholar] [CrossRef]
  36. Xu, L.; Lai, Y.; Ma, D.; Wang, J.; Li, M.; Li, L.; Gao, Z.; Liu, Y.; He, P.; Zhang, Y. Effects of Fiber and Surface Treatment on Airport Pavement Concrete against Freeze–Thawing and Salt Freezing. Materials 2022, 15, 7528. [Google Scholar] [CrossRef] [PubMed]
  37. Lee, S.-J.; Shin, H.; Lee, H.-N.; Park, S.-H.; Kim, H.-M.; Park, C.-G. Effect of Waste PET Fiber on the Mechanical Properties and Chloride Ion Penetration of Emergency Repair Concrete for Road Pavement. Materials 2024, 17, 5352. [Google Scholar] [CrossRef] [PubMed]
  38. Huang, Y.; Ji, Y.; Wang, J.; Wang, Z.; Yu, B.; Zhang, S. Experimental and Modeling Analysis of Polypropylene Fiber Reinforced Concrete Subjected to Alkali Attack And Freeze–Thaw Cycling Effect. Materials 2024, 17, 4529. [Google Scholar] [CrossRef]
  39. Chen, Y.; Waheed, M.S.; Iqbal, S.; Rizwan, M.; Room, S. Durability Properties of Macro-Polypropylene Fiber Reinforced Self-Compacting Concrete. Materials 2024, 17, 284. [Google Scholar] [CrossRef] [PubMed]
  40. Fernandes, M.; Neves, R. Assessment of Fiber Corrosion Inflence in the Flexural Performance of Steel Fiber-Reinforced Concrete. Appl. Sci. 2024, 14, 5611. [Google Scholar] [CrossRef]
  41. Kos, Ž.; Kroviakov, S.; Kryzhanovskyi, V.; Hedulian, D. Strength, Frost Resistance, and Resistance to Acid Attacks on Fiber-Reinforced Concrete for Industrial Floors and Road Pavements with Steel and Polypropylene Fibers. Materials 2022, 15, 8339. [Google Scholar] [CrossRef] [PubMed]
  42. DIN EN 197-1:2011; Cement—Part 1: Composition, Specifications and Conformity Criteria for Common Cements. Deutsches Institut für Normung: Berlin, Germany, 2011.
  43. DIN EN 196-1:2016; Methods of Testing Cement. Determination of Strength. Deutsches Institut für Normung: Berlin, Germany, 2016.
  44. DIN EN 12620:2008-07; Aggregates for Concrete. Deutsches Institut für Normung: Berlin, Germany, 2008.
  45. DSTU B V.2.7-75-98; Crushed Stone and Gravel Are Dense Natural for Building Materials, Products, Structures and Works. 1999. Available online: https://online.budstandart.com/ua/catalog/doc-page.html?id_doc=4674 (accessed on 12 December 2024).
  46. DSTU B V.2.7-32-95; Building Materials. Sand Dense Natural for Construction Materials, Products, Designs and Works. Specifications. 1996. Available online: https://online.budstandart.com/ua/catalog/doc-page.html?id_doc=4053 (accessed on 12 December 2024).
  47. Information about MC-PowerFlow 3200 on the Official Website of MC-Bauchemie. Available online: https://www.mc-bauchemie.com/products/admixtures-and-additives/superplasticizers/mc-powerflow-3200.html (accessed on 12 December 2024).
  48. DIN EN 934-2:2012; Admixtures for Concrete, Mortar and Grout Concrete Admixtures. Definitions, Requirements, Conformity, Marking and Labelling. Deutsches Institut für Normung: Berlin, Germany, 2012.
  49. Information about Steel Fiber on the Official Website of Stalkanat-Silur. Available online: https://stalkanat.com.ua/en/catalog/stalnaya-fibra-s-zagnutymi-konczami-he/ (accessed on 12 December 2024).
  50. DIN EN 14889-1:2006; Fibres for Concrete—Part 1: Steel Fibres–Definitions, Specifications and Conformity. Deutsches Institut für Normung: Berlin, Germany, 2006.
  51. Information about Polypropylene Fiber on the Official Website of Bautech-Ukraine. Available online: https://bautech.com.ua/product/baumesh/ (accessed on 12 December 2024).
  52. DIN EN 14889-2:2006; Fibres for Concrete—Part 2: Polymer Fibres–Definitions, Specifications and Conformity. Deutsches Institut für Normung: Berlin, Germany, 2006.
  53. DIN EN 12350-2:2019; Testing Fresh Concrete. Slump Test. Deutsches Institut für Normung: Berlin, Germany, 2019.
  54. DSTU B V.2.7-114:2002; Concrete Mixtures. Test Methods. 2002. Available online: https://online.budstandart.com/ua/catalog/doc-page?id_doc=4913 (accessed on 12 December 2024).
  55. DIN EN 206-1:2001; Concrete. Specification, Performance, Production and Conformity. Deutsches Institut für Normung: Berlin, Germany, 2001.
  56. Huber, B.; Hilbig, H.; Drewes, J.E.; Müller, E. Evaluation of Concrete Corrosion after Short- and Long-term Xxposure to Chemi-cally and Microbially Generated Sulfuric Acid. Cem. Concr. Res. 2017, 94, 36–48. [Google Scholar] [CrossRef]
  57. Shen, Y.; Liu, B.; Lv, J.; Shen, M. Mechanical Properties and Resistance to Acid Corrosion of Polymer Concrete Incorporating Ceramsite, Fly Ash and Glass Fibers. Materials 2019, 12, 2441. [Google Scholar] [CrossRef]
  58. Song, Z.; Li, S.; Brouwers, H.J.H.; Yu, Q. Corrosion Risk and Corrosion-induced Deterioration of Ultra-High-Performance Fiber-reinforced Concrete Containing Initial Micro-defects. Cem. Concr. Compos. 2023, 142, 105208. [Google Scholar] [CrossRef]
  59. Rajkohila, A.; Prakash Chandar, S.; Ravichandran, P.T. Influence of Natural Fiber Derived from Agricultural Waste on Durability and Micro-Morphological Analysis of High-Strength Concrete. Buildings 2023, 13, 1667. [Google Scholar] [CrossRef]
  60. Antón, C.; Gurdián, H.; de Vera, G.; Climent, M.-Á. Effect of a Crystalline Admixture on the Permeability Properties of Concrete and the Resistance to Corrosion of Embedded Steel. Appl. Sci. 2024, 14, 1731. [Google Scholar] [CrossRef]
  61. Htet, P.; Chen, W.; Hao, H.; Li, Z.; Shaikh, F. Hybrid Fibre Reinforced Recycled Aggregate Concrete: Dynamic Mechanical Properties and Durability. Constr. Build. Mater. 2024, 415, 134044. [Google Scholar] [CrossRef]
  62. ASTM C642-21; Standard Test Method for Density, Absorption, and Voids in Hardened Concrete. ASTM International: West Conshohocken, PA, USA, 2021.
  63. DIN EN 12390-2:2019; Testing Hardened Concrete. Making and Curing Specimens for Strength Tests. Deutsches Institut für Normung: Berlin, Germany, 2019.
  64. DSTU B V.2.7-2014:2009; Building Materials. Concrete. Methods of Determining the Strength of Control Samples. Available online: https://online.budstandart.com/ua/catalog/doc-page.html?id_doc=25943 (accessed on 12 December 2024).
  65. DSTU B GOST 27677:2011; Corrosion Protection in Construction. Concretes. General Requirements for Testing. 2011. Available online: http://online.budstandart.com/ua/catalog/doc-page?id_doc=28066 (accessed on 12 December 2024).
  66. Wang, Y.; Li, L.; An, M.; Sun, Y.; Yu, Z.; Huang, H. Factors Influencing the Capillary Water Absorption Characteristics of Concrete and Their Relationship to Pore Structure. Appl. Sci. 2022, 12, 2211. [Google Scholar] [CrossRef]
  67. Li, C. Relationship Between Water Absorption and Porosity in Concrete with Limestone Powder Addition. Struct. Concr. 2021, 23, 3284–3293. [Google Scholar] [CrossRef]
  68. Sun, R.; Wang, D.; Wang, Y.; Zhang, L.; Gu, Y. Durability and Improvement of Cement-Based Revetment Materials Serving in Subtidal, Intertidal, and Supratidal Environments. Materials 2022, 15, 3210. [Google Scholar] [CrossRef] [PubMed]
  69. Jain, A.; Gencturk, B. Multiphysics and Multiscale Modeling of Coupled Transport of Chloride Ions in Concrete. Materials 2021, 14, 885. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Steel hooked-end fiber (above) and polypropylene fiber (below).
Figure 1. Steel hooked-end fiber (above) and polypropylene fiber (below).
Constrmater 05 00006 g001
Figure 2. Flowchart of investigated concretes and fiber concretes.
Figure 2. Flowchart of investigated concretes and fiber concretes.
Constrmater 05 00006 g002
Figure 3. The influence of the SF (a) and PF (b) amounts on the water adsorption and volume of the permeable voids of the investigated fiber-reinforced concretes.
Figure 3. The influence of the SF (a) and PF (b) amounts on the water adsorption and volume of the permeable voids of the investigated fiber-reinforced concretes.
Constrmater 05 00006 g003
Figure 4. The appearance of the tested fiber concrete samples after 6 months (a) and 12 months (b) of aging in an acidic environment of pH = 3.
Figure 4. The appearance of the tested fiber concrete samples after 6 months (a) and 12 months (b) of aging in an acidic environment of pH = 3.
Constrmater 05 00006 g004
Figure 5. The influence of the SF (a) and PF (b) dosage on the change in compressive strength of the concretes after 6 and 12 months of exposure to water and an acidic environment.
Figure 5. The influence of the SF (a) and PF (b) dosage on the change in compressive strength of the concretes after 6 and 12 months of exposure to water and an acidic environment.
Constrmater 05 00006 g005
Figure 6. The results of the X-ray analysis of the cement–sand matrix of concrete samples with a CC composition after 12 months of aging in water (a) and an acidic environment (b).
Figure 6. The results of the X-ray analysis of the cement–sand matrix of concrete samples with a CC composition after 12 months of aging in water (a) and an acidic environment (b).
Constrmater 05 00006 g006
Table 1. Characteristics of fibers used.
Table 1. Characteristics of fibers used.
Fiber TypeLength, mmDiameter, mmUltimate Tensile Strength, MPaE-Modul, GPa
SF5011150210
PF360.685302
Table 2. Compositions of the investigated concrete and fiber concretes with different fiber types [41].
Table 2. Compositions of the investigated concrete and fiber concretes with different fiber types [41].
No. of MixtureMarkingCompositions, kg/m3
CementCrushed StoneSandSFPFMC-Power
Flow 3200
Water
1Control concrete (CC)36011107803.40180
2Fiber concrete with steel fibers at 15 kg/m3 (SF 15)779153.64
3Fiber concrete with steel fibers at 20 kg/m3 (SF 20)77820
4Fiber concrete with steel fibers at 25 kg/m3 (SF 25)77725
5Fiber concrete with polypropylene fibers at 2.0 kg/m3 (PF 2)11057702.04.08
6Fiber concrete with polypropylene fibers at 2.5 kg/m3 (PF 2.5)11037672.5
7Fiber concrete with polypropylene fibers at 3.0 kg/m3 (PF 3)11027633.0
Table 3. The compressive strength of the studied fiber concrete after 6 and 12 months of exposure to water and an acidic environment.
Table 3. The compressive strength of the studied fiber concrete after 6 and 12 months of exposure to water and an acidic environment.
Mixture 6 Months of Exposure12 Months of Exposure
Strength After Soaking in Water, MPaStrength After Aging in an Acidic Environment, MPaStrength ReductionStrength After Soaking in Water, MPaStrength After Aging in an Acidic Environment, MPaStrength
Reduction
CC45.434.424%52.933.736%
SF 1549.536.426%55.236.035%
SF 2052.640.423%56.538.432%
SF 2553.841.623%56.840.329%
PF 248.236.225%53.635.334%
PF 2.550.139.421%54.837.931%
PF 352.442.020%56.641.127%
Table 4. Changes in the weight of the investigated fiber-reinforced concretes after 6 and 12 months of aging in water and an acidic environment.
Table 4. Changes in the weight of the investigated fiber-reinforced concretes after 6 and 12 months of aging in water and an acidic environment.
Mixture Average Weight of Samples Before Aging, g6 Months of Exposure12 Months of Exposure
Average Weight of Samples After Aging in Water, gAverage Weight of Samples After Aging in Acidic Medium, gDifferenceAverage Weight of Samples After Aging in Water, gAverage Weight of Samples After Aging in Acidic Medium, gDifference
CC242024222437+0.6%24312248−7.5%
SF 15244024422404−1.6%24522407−1.8%
SF 20243724492404−1.8%24632407−2.3%
SF 25244624382402−1.5%24512408−1.8%
PF 2242324222402−0.8%24262399−1.1%
PF 2.5242524232376−1.9%24252369−2.3%
PF 3242624252419−0.2%24282413−0.6%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Kroviakov, S.; Kryzhanovskyi, V.; Hedulian, D. Comparison of the Corrosion Resistance of Fiber-Reinforced Concrete with Steel and Polypropylene Fibers in an Acidic Environment. Constr. Mater. 2025, 5, 6. https://doi.org/10.3390/constrmater5010006

AMA Style

Kroviakov S, Kryzhanovskyi V, Hedulian D. Comparison of the Corrosion Resistance of Fiber-Reinforced Concrete with Steel and Polypropylene Fibers in an Acidic Environment. Construction Materials. 2025; 5(1):6. https://doi.org/10.3390/constrmater5010006

Chicago/Turabian Style

Kroviakov, Sergii, Vitalii Kryzhanovskyi, and Daria Hedulian. 2025. "Comparison of the Corrosion Resistance of Fiber-Reinforced Concrete with Steel and Polypropylene Fibers in an Acidic Environment" Construction Materials 5, no. 1: 6. https://doi.org/10.3390/constrmater5010006

APA Style

Kroviakov, S., Kryzhanovskyi, V., & Hedulian, D. (2025). Comparison of the Corrosion Resistance of Fiber-Reinforced Concrete with Steel and Polypropylene Fibers in an Acidic Environment. Construction Materials, 5(1), 6. https://doi.org/10.3390/constrmater5010006

Article Metrics

Back to TopTop