Next Article in Journal
Research on Application of Fractional Calculus Operator in Image Underlying Processing
Previous Article in Journal
The Multiscale Principle in Nature (Principium luxuriæ): Linking Multiscale Thermodynamics to Living and Non-Living Complex Systems
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Panchal et al. 3D FEM Simulation and Analysis of Fractal Electrode-Based FBAR Resonator for Tetrachloroethene (PCE) Gas Detection. Fractal Fract. 2022, 6, 491

by
Bhargav Panchal
1,2,*,
Avanish Bhadauria
1,* and
Soney Varghese
2
1
Council of Scientific and Industrial Research–Central Electronics Engineering Research Institute (CSIR–CEERI), Pilani 333031, India
2
Nanomaterials & Devices Research Laboratory, National Institute of Technology, Calicut 673601, India
*
Authors to whom correspondence should be addressed.
Fractal Fract. 2024, 8(1), 36; https://doi.org/10.3390/fractalfract8010036
Submission received: 13 December 2023 / Accepted: 21 December 2023 / Published: 4 January 2024

Avanish Bhadauria from the Council of Scientific and Industrial Research–Central Electronics Engineering Research Institute (CSIR–CEERI), India, was not included as an author in the original publication [1]. The corrected Author Contributions statement appears here:
  • Author Contributions: Conceptualization, B.P., A.B. and S.V.; methodology, B.P.; software, B.P.; validation, S.V., A.B. and B.P.; formal analysis, B.P., A.B. and S.V.; investigation, B.P., A.B. and S.V.; resources, B.P. and A.B.; data curation, B.P.; writing—original draft, B.P.; writing—review and editing, A.B. and S.V.; visualization, B.P.; supervision, A.B. and S.V.; project administration, A.B. and S.V. All authors have read and agreed to the published version of the manuscript.
In the original publication, there was a mistake in Figure 2. It has been changed into a single port to align with the simulation. The correct Figure 2 appears below:
In Section 3.2.3, page 7, the dimension was changed from 50 μm × 50 μm to 49 μm × 49 μm as the fractal electrode with a width of 1 μm which was implanted on the top electrode of FBAR. A correction has been made as follows:
A 49 μm × 49 μm area was selected for its high resonance frequency of 2.52 GHz and maximum sensitivity of 4.83 kHz/ppm.
Also, changes on units were made from kHz/ppb to kHz/ppm throughout Section 3.2.4. In Table 6 of Section 4, the unit in Column 5, Row 1 (Present Work) was changed from kHz/ppb to kHz/ppm.
The authors state that the scientific conclusions are unaffected. This correction was approved by the Academic Editors and the Editor-in-Chief. The original publication has also been updated.

Reference

  1. Panchal, B.; Bhadauria, A.; Varghese, S. 3D FEM Simulation and Analysis of Fractal Electrode-Based FBAR Resonator for Tetrachloroethene (PCE) Gas Detection. Fractal Fract. 2022, 6, 491. [Google Scholar] [CrossRef]
Figure 2. Butterworth–Vandyke (BVD) Equivalent circuit of FBAR.
Figure 2. Butterworth–Vandyke (BVD) Equivalent circuit of FBAR.
Fractalfract 08 00036 g002
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Panchal, B.; Bhadauria, A.; Varghese, S. Correction: Panchal et al. 3D FEM Simulation and Analysis of Fractal Electrode-Based FBAR Resonator for Tetrachloroethene (PCE) Gas Detection. Fractal Fract. 2022, 6, 491. Fractal Fract. 2024, 8, 36. https://doi.org/10.3390/fractalfract8010036

AMA Style

Panchal B, Bhadauria A, Varghese S. Correction: Panchal et al. 3D FEM Simulation and Analysis of Fractal Electrode-Based FBAR Resonator for Tetrachloroethene (PCE) Gas Detection. Fractal Fract. 2022, 6, 491. Fractal and Fractional. 2024; 8(1):36. https://doi.org/10.3390/fractalfract8010036

Chicago/Turabian Style

Panchal, Bhargav, Avanish Bhadauria, and Soney Varghese. 2024. "Correction: Panchal et al. 3D FEM Simulation and Analysis of Fractal Electrode-Based FBAR Resonator for Tetrachloroethene (PCE) Gas Detection. Fractal Fract. 2022, 6, 491" Fractal and Fractional 8, no. 1: 36. https://doi.org/10.3390/fractalfract8010036

Article Metrics

Back to TopTop