Previous Article in Journal
Hybrid Fusion of Time–Intensity Curve, Deep Learning, and Fractional Zernike–Caputo Features for Accurate Liver Lesion Classification in DCE-MRI
Previous Article in Special Issue
Influence of Intrapancreatic Fat Deposition on Regional and Total Pancreatic T1 Relaxation Times at 3.0 Tesla MRI
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI

by
Abla Bedoui
1,*,
Julieta Anahí Rancati
2,
Ignacio Lugones
2 and
Mohammed Cherkaoui
1
1
School of Engineering, Computer Science and Artificial Intelligence, Long Island University, Brooklyn, NY 11201, USA
2
Unidad de Cirugía Cardiovascular, Hospital General de Niños “Dr. Pedro de Elizalde”, Buenos Aires C1270AAN, Argentina
*
Author to whom correspondence should be addressed.
J. Imaging 2026, 12(9), 416; https://doi.org/10.3390/jimaging12090416
Submission received: 2 July 2026 / Revised: 18 August 2026 / Accepted: 27 August 2026 / Published: 3 September 2026

Abstract

Automated segmentation of the left and right ventricles (LVs and RVs) in cine cardiac MRI (CMR) underpins reliable volumetry and mass estimation. However, papillary muscles and trabeculae (PM/T) introduce clinically meaningful variability and exacerbate cross-dataset domain shift. We present VentrEX, an anatomically guided pipeline. The core segmenter, VentrEX-Seg, is a 3D encoder-decoder with parallel channel-spatial attention and a Transformer bottleneck. Training is performed exclusively on ACDC. A lightweight PM/T module automatically extracts papillary and trabecular burdens and standardizes cavity volumes. External evaluation is zero-shot (no fine-tuning) on Sunnybrook (LV) and MM-WHS MRI (RV). We report Dice, HD95 (mm); for volumetry, we use Bland-Altman analyses (LV and RV volumes). Attention/Grad-CAM visualizations support interpretability. On ACDC, VentrEX achieved higher Dice and lower boundary error than U-Net, nnU-Net, CBAM, and VentrEX-Seg. Zero-shot performance was preserved externally (e.g., Sunnybrook LV Dice 0.9053, HD95 4.95 mm; MM-WHS RV Dice 0.9236, HD95 6.61 mm). Patient-level Bland–Altman analyses characterized LV and RV volumetric agreement. Qualitative overlays and 3D reconstructions showed fewer PM/T “leaks” and anatomically plausible borders across ED/ES. Single-source training with dual zero-shot external tests demonstrates robustness under domain shift. The combination of parallel attention and a Transformer bottleneck enables accurate, transparent cine-CMR segmentation across datasets.
Keywords: cardiac MRI; deep learning; transformer; ventricular segmentation; papillary muscles; trabeculae; explainable AI; domain shift cardiac MRI; deep learning; transformer; ventricular segmentation; papillary muscles; trabeculae; explainable AI; domain shift

Share and Cite

MDPI and ACS Style

Bedoui, A.; Anahí Rancati, J.; Lugones, I.; Cherkaoui, M. VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI. J. Imaging 2026, 12, 416. https://doi.org/10.3390/jimaging12090416

AMA Style

Bedoui A, Anahí Rancati J, Lugones I, Cherkaoui M. VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI. Journal of Imaging. 2026; 12(9):416. https://doi.org/10.3390/jimaging12090416

Chicago/Turabian Style

Bedoui, Abla, Julieta Anahí Rancati, Ignacio Lugones, and Mohammed Cherkaoui. 2026. "VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI" Journal of Imaging 12, no. 9: 416. https://doi.org/10.3390/jimaging12090416

APA Style

Bedoui, A., Anahí Rancati, J., Lugones, I., & Cherkaoui, M. (2026). VentrEX: An Anatomically Guided Deep Learning Pipeline for Ventricular Segmentation in Cine Cardiac MRI. Journal of Imaging, 12(9), 416. https://doi.org/10.3390/jimaging12090416

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Article metric data becomes available approximately 24 hours after publication online.
Back to TopTop