Next Article in Journal
First Report of Pichia bruneiensis in a Spontaneous Sugarcane Juice Fermentation: A Case Study from an Artisanal Distillery in the Ecuadorian Amazon
Previous Article in Journal
Development and Evaluation of a Urinary Na/K Ratio Prediction Model: A Systematic Comparison from Attention-Based Deep Learning to Classical Ensemble Approaches
Previous Article in Special Issue
Clinical Evidence of Wear Occurrence in CFR-PEEK and Metallic Osteosynthesis Implants: A Systematic Literature Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study

1
Sarcoma Center, Vinmec Times City International Hospital, Vinmec Healthcare System, Hanoi 113-900, Vietnam
2
Graduate School of Medicine, Osaka Metropolitan University, Osaka 545-8585, Japan
3
College of Health Sciences, VinUniversity, Hanoi 131-001, Vietnam
4
3D Technology in Medicine Center, College of Health Sciences, VinUniversity, Hanoi 131-001, Vietnam
*
Authors to whom correspondence should be addressed.
Bioengineering 2026, 13(2), 253; https://doi.org/10.3390/bioengineering13020253
Submission received: 12 January 2026 / Revised: 25 January 2026 / Accepted: 4 February 2026 / Published: 22 February 2026

Abstract

Background: Reconstruction of the proximal humerus after wide tumor resection is technically demanding, and traditional methods such as allograft–prosthetic composites, reverse shoulder arthroplasty, and metal implants are limited by graft unavailability, pediatric size mismatch, their high cost, and metal-related stress shielding. Polyether ether ketone (PEEK), with its modulus closer to cortical bone and radiolucency, offers a promising alternative. Building upon the success in craniomaxillofacial surgery and its favorable physical characteristics, we applied personalized 3D-printed PEEK implants for proximal humerus reconstruction. This study reports the first evidence of applying patient-specific 3D-printed PEEK implants in the proximal humerus. Methods: A retrospective cohort study was conducted on seven patients who underwent wide resection of primary malignant bone tumors of the proximal humerus, followed by reconstruction using patient-specific 3D-printed PEEK implants. Implant design was based on preoperative computed tomography (CT) imaging, incorporating contralateral humeral mirroring and computer-aided design. The implants were fabricated using fused deposition modeling (FDM) with medical-grade PEEK under stringent thermal control (nozzle temperature > 400 °C and heated build chamber), followed by a controlled annealing process to minimize internal stress, optimize polymer crystallinity, and enhance mechanical durability. Outcomes assessed included implant survival, oncologic control, shoulder range of motion, and functional outcomes measured using the Musculoskeletal Tumor Society (MSTS) score. The mean follow-up duration was 56.3 months. Results: All patient-specific PEEK implants were successfully manufactured and implanted with satisfactory geometric accuracy. Mechanical implant survival was 85.7% at final follow-up, with one implant fracture occurring at 28 months. No cases of deep infection, dislocation, loosening, or permanent neurovascular injury were observed. Local soft-tissue recurrence occurred in two patients (28.6%), without distant metastasis or tumor-related mortality. The limb-salvage rate was 100%. At final follow-up, the mean MSTS score was 23.0 ± 1.6. Shoulder motion was limited but comparable to outcomes reported for conventional anatomic megaprosthetic reconstructions. Conclusions: Patient-specific 3D-printed PEEK implants provide a feasible and oncologically safe option for proximal humerus reconstruction after tumor resection, with acceptable midterm implant survival and functional outcomes. The favorable elastic modulus and radiolucency of PEEK offer distinct biomechanical and imaging advantages over metallic implants. Further design optimization and larger prospective studies are warranted to enhance mechanical durability and functional restoration.

1. Introduction

The proximal humerus is a common site for primary and metastatic bone tumors, accounting for 7–10% of bone sarcomas. It is the second most frequent site for osseous sarcomas and the third for osteosarcomas. After the femur, the humerus is the second most affected long bone for pathological fractures, with an incidence of 16–27%, significantly impacting load-bearing and daily activities [1,2,3]. Shoulder reconstruction aims to restore stability, preserve deltoid and rotator cuff function when possible, and achieve pain-free mobility to maximize quality of life after major bone loss [4].
Surgical treatment for bone tumors largely depends on tumor histology and typically involves wide resection, often resulting in significant bone defects. However, recent advancements in adjuvant therapies, including multi-target chemotherapy and localized radiation, have enabled an increasing number of patients to undergo limb-sparing tumor resections [5,6,7,8].
There is no consensus regarding the best reconstructive technique after proximal humerus resection. Several reconstructive options are available, including allografts, alloprosthetic composites (APC), megaprosthetic (megaendoprostetic) replacement (MPR), and reverse shoulder arthroplasty (RSA) [9].
Moreover, several autologous grafts (fibula, scapular crest, or clavicle) have been described. Because autologous grafts often are used in conjunction with a shoulder arthrodesis, prostheses, osteo- articular allografts, and allograft-prosthesis composites are the only reconstructions allowing for a mobile glenohumeral joint [10,11,12]. Although all of these approaches are in use, and there are some situations where only one approach might be appropriate for a particular patient, there are many scenarios in which all are potential options. However, because there are no prospective or randomized trials, it is difficult to know which approach is best in terms of functional out- come, implant survivorship, or complications.
Metallic tumor prostheses, while mechanically robust, are characterized by a high elastic modulus which contributes to stress shielding, periprosthetic bone loss, and implant-related complications, particularly in pediatric and young adult populations. In addition, metallic implants generate substantial imaging artifacts, complicating postoperative surveillance for local recurrence, in skeletally immature patients, these problems are compounded by small bone size.
Polyether ether ketone (PEEK) has emerged as a high-performance biomaterial with properties that may address several of these challenges. Advances in three-dimensional (3D) printing now make it possible to combine PEEK’s material advantages with exact anatomic matching. Additive manufacturing can fabricate a patient-specific implant directly from the patient’s Computerized Tomography (CT) or Magnetic Resonance Imaging (MRI) model, yielding a prosthesis that conforms precisely to the resected proximal humerus [13].
PEEK is a member of the Polymers class of biomaterials. Polymers consist of many repeating units of a primary sequence, i.e., monomer, which consists of a long backbone carbon chain linked by covalent bonds. PEEK is classified as a linear homopolymer, i.e., similar monomer segments. PEEK is among the newer special thermoplastic engineering plastic types and has shown promising biological, mechanical, and chemical properties [14,15].
In comparison to metals, PEEK and polymers generally have an elastic modulus closer to that of bone, thereby decreasing the stress shielding effect seen in metals used for arthroplasty or fracture fixation such as stainless steel. They also avoid the side effect of releasing metal ions in the body which may cause adverse effects such as osteolysis and immune reactions. They are more compatible with most radiological techniques such as CT and MRI scans used for the monitoring and follow-up of treatment [16].
PEEK specically has been shown to have superior properties such as high thermal stability, toughness, and rigidity, creep resistance, ease of processing, self-lubricating, and abrasion resistance [16]. It has also been shown to be relatively non-toxic with wear particles that do not damage human cells [17].
To date, however, no PEEK implants in clinical practice for shoulder reconstructions have been reported.
Accordingly, we developed patient-specific 3D-printed PEEK implants by scientist, engineer, and orthopedic doctors. The aim of this study was to evaluate midterm implant survival, shoulder function, and oncologic safety in this novel cohort. We assessed functional performance (MSTS scores, range of motion) and complications (implant failure, tumor recurrence, etc.) to determine whether patient-specific PEEK implants can provide durable, high-function reconstruction without the stress-shielding or imaging limitations of conventional metal prostheses.

2. Materials and Methods

This study was conducted using retrospective data. All patients were informed of the potential risks associated with 3D-printed humerus replacement surgery, including the possibility of requiring a second-stage procedure. This study received approval from the Ethics Committee. Written informed consent for the publication of anonymized patient information was obtained for all cases in this study.

2.1. Inclusion and Exclusion Criteria

Patients were included in this study if they met all the following criteria: histologically confirmed primary bone sarcoma involving the proximal humerus, indication for wide oncologic resection of the proximal humerus, reconstruction using a personalized 3D-printed PEEK implant, minimum postoperative follow-up of 12 months.
Exclusion Criteria: metastatic bone disease or non-sarcomatous tumors of the proximal humerus, insufficient bone quality or severe osteoporosis.

2.2. 3D-Printed PEEK Implant Production

All patients underwent preoperative imaging with thin slice computed tomography of the affected shoulder. Accurate CT data acquisition was considered essential for the design of patient-specific implants. CT scans were obtained with a slice thickness of 1.0 mm (Siemens SOMATOM series, Germany), which provides an optimal balance between spatial resolution and image noise while limiting radiation exposure (Figure 1).
Digital Imaging and Communications in Medicine (DICOM) data were imported into Mimics® software (version 28.0, Materialise, Leuven, Belgium) for three-dimensional reconstruction of the proximal humerus. Segmentation was performed to delineate cortical and cancellous bone, and a three-dimensional bone model of the affected humerus was generated. In cases of extensive tumor-related bone destruction, CT data from the contralateral healthy humerus were acquired, mirrored, and used as an anatomical template. Surface-based registration using an Iterative Closest Point algorithm was applied to align the mirrored model with the affected side, allowing restoration of native humeral length, offset, and proximal geometry.
Virtual tumor resection was performed in the computer-aided design (CAD) environment using mediCAD software (version 7.0, mediCAD Hectec GmbH, Altdorf, Germany) according to preoperative oncologic planning and intended surgical margins. Based on the residual bone morphology, a patient-specific implant was designed using CAD software. The implant consisted of an anatomically contoured proximal segment and a diaphyseal intramedullary stem. Stem diameter and length were individually determined based on the intramedullary canal dimensions of the residual humeral shaft to achieve press-fit fixation while preserving cortical bone integrity. Multiple suture tunnels (2.5–3.5 mm in diameter) were incorporated into the proximal portion of the implant to allow reattachment of the rotator cuff remnants, deltoid muscle, and joint capsule. The implant surface was designed with a smooth finish to reduce soft-tissue irritation (Figure 2).
The finalized implant design was manufactured using medical-grade PEEK by fused deposition modeling (FDM) on a PEEK-300 printer (CreateBot, Zhejiang, China). Printing was performed on a high-temperature industrial FDM printer capable of processing PEEK, equipped with a nozzle temperature exceeding 400 °C and a heated build chamber (≥120–150 °C) to ensure adequate interlayer adhesion and dimensional stability. A controlled printing environment was maintained throughout the fabrication process to minimize warping and internal stress.
Following printing, the implants underwent a controlled annealing process, consisting of gradual heating and slow cooling under predefined temperature conditions, to optimize polymer crystallinity, reduce residual stress, and enhance mechanical strength and fatigue resistance. Post-processing included removal of support structures, surface finishing, and dimensional inspection to verify geometric accuracy relative to the digital CAD model.
The total manufacturing time from finalized DICOM data to completion of the implant was approximately 7–14 days, followed by 48 h of standard medical sterilization prior to implantation. All implants were inspected for dimensional accuracy and surface integrity before surgical use. After they were made, the implants were placed in an autoclave at 121 °C for 30 min, then gamma-irradiated.

2.3. Surgical Technique

All the surgeries were performed by a team including experienced musculoskeletal oncologists (T. T. D., N. T. Q. S., T. D. T. and D. M. Q.). After general anesthesia, all patients were placed in the beach chair position. All operations were performed via a deltopectoral approach. The excision of soft tissue depended on the involvement of the tumors. The axillary nerve was identified and protected carefully during the operation. A jigsaw was used to perform the osteotomy according to the preoperative plan. The previous biopsy track along with the tumor was removed.
The patient-specific 3D-printed PEEK implant was subsequently implanted into the humeral shaft. Based on preoperative planning, fixation was achieved using a press-fit stem, with or without supplemental polymethylmethacrylate bone cement (Simplex® P, Stryker, MI, USA), and further reinforced with plate-and-screw fixation. The implant was oriented to restore appropriate humeral version and shoulder alignment (Figure 3).
Reconstruction of the soft tissues was performed using the integrated suture tunnels designed into the proximal portion of the implant. Attention was paid to reattachment of the deltoid to optimize postoperative shoulder function. After confirming implant stability and soft-tissue balance, the wound was thoroughly irrigated with saline solution.

2.4. Postoperative Management

The shoulder joint was maintained on an abduction splint for at least 6 weeks postoperatively. All patients were allowed to perform active movements of the wrist and the elbow and passive exercises of the shoulder on the first day after surgery. After 6 weeks, patients were encouraged to perform active exercises of the shoulder joint to achieve more flexible ROM.
All patients were followed up with clinical and imaging assessments. X-ray of the reconstructed shoulder joint was performed after surgery and then every 3 months thereafter. Chest CT scan was performed every 3 months, and bone scan every 6 months to identify potential metastases. At the last follow-up, active ROM, including abduction, forward flexion, external rotation and internal rotation, was measured and recorded. The MSTS functional score were also assessed at the last follow-up (Figure 4).

3. Results

3.1. Patient and Tumor Characteristics

Seven patients underwent wide resection of the proximal humerus followed by reconstruction using patient-specific 3D-printed PEEK implants. The mean age at surgery was 23 years (range: 7–58 years); five patients were male and two female. The underlying diagnoses included osteosarcoma (n = 4, 57.1%), chondrosarcoma (n = 2, 28.6%), and Ewing sarcoma (n = 1, 14.3%). All tumors were classified as Enneking stage IIB. The tumor involved the right humerus in three cases and the left in four.
Two patients (28.6%) had undergone inappropriate biopsy or unplanned surgery before referral, and two (28.6%) presented with pathologic fractures. The mean follow-up duration was 56.3 months (range: 19–112 months) (Table 1).

3.2. Design, Manufacturing, and Geometric Fidelity

All seven patient-specific implants were successfully designed using contralateral mirroring and segmental defect reconstruction, then manufactured via high-temperature FDM of medical-grade PEEK followed by annealing. Post-manufacturing quality control confirmed that all implants met the predefined geometric tolerance, with a maximum surface deviation of less than 2 mm compared with the original CAD model. No gross dimensional mismatch was recorded between planned and produced constructs (Table 2).

3.3. Surgical Complications

Three patients (42.8%) experienced complications related to the procedure or implant. Two patients (28.6%) developed local soft-tissue recurrence within the operative field. One patient (14.3%) sustained an implant fracture 28 months postoperatively after a traumatic fall. No cases of dislocation, deep infection, clinically significant loosening, vascular injury, or permanent major nerve injury were observed.
Mechanical implant survival, defined as absence of fracture or loosening, was 85.7% (6/7) at final follow-up. All patients, including the one who underwent revision for implant fracture, maintained limb salvage, resulting in a 100% limb-salvage rate.

3.4. Oncologic Outcomes

Two patients (28.6%) developed soft-tissue local recurrence, both managed without amputation. No patient developed distant metastasis during the observation period. At latest follow-up, six of seven patients (85.7%) had no evidence of disease (disease-free), while oncologic status was indeterminate in one patient due to incomplete follow-up data. There were no tumor-related deaths in this cohort (Table 3).

3.5. Functional Outcomes

At final follow-up, the mean MSTS score was 23.0 ± 1.6 (range, 21–25). Analysis of shoulder range of motion demonstrated a mean flexion of 35.7°, extension 20.0°, abduction 30.7°, internal rotation 80.0°, and external rotation 45.7° (Table 4 and Table 5).

4. Discussion

The optimal approach to reconstructing proximal humerus defects following sarcoma resection remains a subject of ongoing debate. Successful reconstruction must balance oncologic safety with long-term preservation of limb function. Various surgical techniques have been proposed for humeral reconstruction, each with specific advantages and limitations.
PEEK was first introduced in orthopedics in the late 1980s, initially for internal fixation and femoral stems. Its application expanded in the mid-to-late 1990s with spinal interbody fusion cages [18]. By 2005, the U.S. FDA approved a dynamic pedicle screw fixation system incorporating PEEK for lumbar fusion, signaling broader clinical acceptance. Over the past two decades, PEEK has gained widespread use in spinal and trauma devices due to its favorable mechanical and biocompatibility profiles.
Several intrinsic properties of PEEK support its use in limb-sparing oncologic reconstruction. First, its elastic modulus (~3–4 GPa) closely approximates that of cortical bone, in contrast to titanium (~110 GPa) [19]. This modulus-matching reduces stress shielding and may mitigate long-term complications such as bone resorption and implant loosening [20]. These properties are particularly relevant in young patients requiring durable reconstructions, where metallic megaprostheses often fail over time due to biomechanical mismatch [21]. Nevertheless, one implant in our series failed due to fracture at 28 months, highlighting the need for continued optimization of fatigue resistance. Future iterations may consider carbon fiber reinforcement or design modifications to improve mechanical durability while maintaining elasticity.
Second, PEEK is radiolucent and MRI-compatible, offering a clear advantage in postoperative surveillance. In oncologic cases, early detection of local recurrence is critical.
Third, the combination of 3D printing and PEEK allows for truly patient-specific reconstruction. Given the variability of bone defects after tumor resection, especially in skeletally immature or anatomically complex cases, the ability to design implants that precisely replicate the resected anatomy is invaluable. In our study, all constructs were based on contralateral mirroring and achieved sub-millimeter geometric accuracy. Prior work has demonstrated the feasibility of using 3D-printed PEEK in shoulder reconstructions with satisfactory fit and early outcomes [22]. Moreover, the lower density of PEEK (~1.3 g/cm3 versus ~4.5 g/cm3 for titanium) may reduce mechanical strain on adjacent soft tissues, potentially improving comfort and functional endurance, although this was not directly measured in our cohort.
Despite these advantages, pure PEEK is biologically inert and hydrophobic, limiting osseointegration. In osteoporotic or elderly bone, adding 20% nano-hydroxyapatite and 10% carbon fiber, or using 3D printing to create controlled porous architectures, can enhance bioactivity and tissue integration without compromising mechanical performance. In our series, additional fixation with plates and screws was employed to ensure primary stability.
When considered in context, the functional and survival outcomes in our cohort are comparable to, and in some respects exceed, those reported for conventional megaprosthetic and allograft reconstructions of the proximal humerus (Table 6). Standard modular megaprostheses (metallic endoprostheses) have historically yielded MSTS scores between 60 and 80% [23]. Osteoarticular allografts, another widely used option, offer anatomical restoration of the resected segment by preserving the graft’s joint surface. Systematic reviews report average MSTS scores of 79–82% following proximal humerus allograft-prosthetic composite (APC) reconstruction, which parallels the functional outcomes observed in our PEEK cohort [24]. However, APCs carry notable risks: union failure or graft resorption occurs in approximately 26% of cases, allograft fractures in ~10%, and overall complication rates may reach 50% [24]. These data suggest that a well-engineered polymer-based implant can serve as a viable and competitive alternative for limb-salvage reconstruction in musculoskeletal oncology.
In our series, the average forward flexion and abduction reflect a markedly limited overhead range of motion, consistent with historical outcomes of hemiarthroplasty-based megaprostheses, which typically achieve only 40–60° of flexion and 30–60° of abduction [25]. This limitation is inherent to anatomic reconstructions using either traditional tumor endoprostheses or our PEEK design, where the prosthesis often functions primarily as a spacer, particularly in the absence of a functional rotator cuff. Shoulder stability may also be compromised by axillary nerve sacrifice, leading to prosthesis subluxation or migration due to imbalanced deltoid forces [12,26,27].
To address these limitations, reverse shoulder arthroplasty (RSA) has been employed in cases of rotator cuff insufficiency, including tumor resections [12,27,28]. These semi-constrained designs medialize and distalize the center of rotation, allowing the deltoid muscle to drive shoulder function effectively [12,29,30]. In a comparative study, Grosel et al. reported superior outcomes with RSA versus hemiarthroplasty following proximal humerus tumor resection, with mean abduction reaching 85° in RSA patients compared to 28° in those receiving hemiarthroplasty [31].
The relatively modest ROM in our cohort may be attributed to the anatomic nature of the reconstruction. Our patient-specific 3D-printed PEEK prostheses restored bone length and geometry but maintained a traditional articulation with the native glenoid. Unlike reverse designs, these implants do not leverage mechanical constraints or altered biomechanics to augment deltoid-driven movement. While PEEK proved to be a safe and effective material for patient-specific reconstruction, it did not confer an intrinsic advantage in range of motion.
Our early experience with 3D-printed PEEK implants for proximal humerus reconstruction demonstrates technical feasibility and acceptable midterm outcomes. To improve implant durability, future work should focus on design optimization using finite element analysis, especially in light of the single implant fracture observed. As PEEK is biologically inert, enhancing osseointegration—via surface roughening or incorporation of bioactive fillers such as hydroxyapatite—may strengthen long-term fixation [32,33].
Patient-specific strategies are key. Pediatric patients may especially benefit from the radiolucency, weight, and customizability of PEEK. Future work should explore hybrid strategies combining the anatomical benefits of personalized PEEK implants with functional enhancements—such as reverse articulation mechanisms or integration with biological grafts—to better restore shoulder motion in this challenging patient population.
This study is limited by the small sample size, which reflects the rarity of proximal humeral sarcomas and the early clinical use of PEEK implants. Therefore, the findings should be interpreted as preliminary and not broadly generalizable. In addition, shoulder function remained limited, particularly in overhead motion, with the reconstruction serving primarily as a stable spacer rather than restoring full mobility. These functional constraints should be clearly discussed with patients preoperatively. Finally, the absence of a control group, such as metallic megaprostheses or reverse total shoulder arthroplasty, limits direct comparison, although published data suggest that RSA may provide superior range of motion through altered biomechanics rather than material-related advantages.
This study presents the first reported series of 3D-printed PEEK-based reconstructions for proximal humerus defects. The findings support PEEK as a promising alternative to metal implants and allografts, particularly due to its favorable biomechanical properties and compatibility. However, larger studies with extended follow-up are necessary to confirm long-term mechanical durability and further optimize clinical outcomes.
Table 6. Comparative clinical and functional outcomes of reconstruction methods.
Table 6. Comparative clinical and functional outcomes of reconstruction methods.
Reconstruction MethodImplant SurvivalMajor
Complications
Mean MSTS ScoreImaging ArtifactCustomization
3D-printed PEEK
(our study)
85.7%Implant fracture (14.3%)23.0 ± 1.6NonePatient-specific
Metal megaprosthesis [34]70–85%Infection,
instability,
loosening
18–24ModerateModular only
APC [35]55–75%Nonunion,
graft fracture,
resorption
19–26ModerateLimited
Osteoarticular allograft [36]40–65%Fracture,
collapse,
degeneration
18–25NoneLimited
3D-printed titanium implant [37]80–95%Stress shielding, stiffness
Mismatch
22–26ModeratePatient-specific
RSA [38]89%Shoulder
instability
23.4ModerateLimited

5. Conclusions

In conclusion, midterm outcomes of 3D-printed PEEK implants showed satisfactory implant survival and functional results, comparable to metal and allograft alternatives. PEEK’s modulus and radiolucency offer biomechanical and imaging advantages. However, limited shoulder motion and one implant fracture highlight the need for further design optimization. Enhancing osseointegration and customizing function-oriented features may improve functional results. PEEK shows strong potential as a patient-specific, limb-sparing solution in orthopedic oncology.

Author Contributions

T.T.D., T.D.T. and L.D.H. conceived and designed the analysis. N.T.Q.S., N.D.T., V.D.T., L.D.H., L.T.H., L.H.P., L.N.A. and D.M.Q. were involved in outlining the methodology, validation, investigation, and data collection. V.S.Q.N. and P.T.H. were involved in methodology, validation, investigation. T.D.T., N.D.T. and L.D.H. wrote the manuscript. T.D.T. and L.D.H. contributed to the project administration. D.M.Q. and T.T.D. reviewed and checked the manuscript. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

This study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board (IRB) of Vinmec Times City International Hospital (approval number: 235/2025/CN/HĐĐĐ VMEC, date: 15/2/2025).

Informed Consent Statement

Informed consent was obtained from all participants prior to surgery, and all participants were given a detailed explanation of the potential risks associated with 3D-printed proximal humerus reconstruction and the possibility of revision procedures. Written informed consent has been obtained from the patients to publish this paper.

Data Availability Statement

The datasets analyzed during the current study are available from the corresponding authors on reasonable request.

Acknowledgments

The authors have no acknowledgments.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
APCAllograft–prosthesis composite
PEEKPolyether ether ketone
MSTSMusculoskeletal Tumor Society score
RSAReverse shoulder arthroplasty

References

  1. Klingebiel, S.; Schneider, K.N.; Gosheger, G.; Ackmann, T.; Timme, M.; Rickert, C.; Deventer, N.; Theil, C. Periprosthetic Stress Shielding of the Humerus after Reconstruction with Modular Shoulder Megaprostheses in Patients with Sarcoma. J. Clin. Med. 2021, 10, 3424. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  2. Rovere, G.; Meschini, C.; Piazza, P.; Messina, F.; Caredda, M.; De Marco, D.; Noia, G.; Maccagnano, G.; Ziranu, A. Proximal Humerus Fractures Treatment in Adult Patients with Bone Metastasis. Eur. Rev. Med. Pharmacol. Sci. 2022, 26, 100–105. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Teunis, T.; Nota, S.P.F.T.; Hornicek, F.J.; Schwab, J.H.; Lozano-Calderón, S.A. Outcome After Reconstruction of the Proximal Humerus for Tumor Resection: A Systematic Review. Clin. Orthop. Relat. Res. 2014, 472, 2245–2253. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Colò, G.; Fusini, F.; Faoro, L.; Popolizio, G.; Ferraro, S.; Ippolito, G.; Leigheb, M.; Surace, M.F. Current Evidence and Surgical Strategies in the Management of Greater Tuberosity Fracture-Dislocations: A Narrative Review. J. Clin. Med. 2025, 14, 5159. [Google Scholar] [CrossRef] [Scilit]
  5. Wafa, H.; Grimer, R.J.; Reddy, K.; Jeys, L.; Abudu, A.; Carter, S.R.; Tillman, R.M. Retrospective Evaluation of the Incidence of Early Periprosthetic Infection with Silver-Treated Endoprostheses in High-Risk Patients: Case-Control Study. Bone Jt. J. 2015, 97-B, 252–257. [Google Scholar] [CrossRef] [Scilit]
  6. Tsantes, A.G.; Altsitzioglou, P.; Papadopoulos, D.V.; Lorenzo, D.; Romanò, C.L.; Benzakour, T.; Tsukamoto, S.; Errani, C.; Angelini, A.; Mavrogenis, A.F. Infections of Tumor Prostheses: An Updated Review on Risk Factors, Microbiology, Diagnosis, and Treatment Strategies. Biology 2023, 12, 314. [Google Scholar] [CrossRef] [Scilit]
  7. Fujiwara, T.; Ebihara, T.; Kitade, K.; Setsu, N.; Endo, M.; Iida, K.; Matsumoto, Y.; Matsunobu, T.; Oda, Y.; Iwamoto, Y.; et al. Risk Factors of Periprosthetic Infection in Patients with Tumor Prostheses Following Resection for Musculoskeletal Tumor of the Lower Limb. J. Clin. Med. 2020, 9, 3133. [Google Scholar] [CrossRef] [Scilit]
  8. Miwa, S.; Yamamoto, N.; Hayashi, K.; Takeuchi, A.; Igarashi, K.; Tsuchiya, H. Surgical Site Infection after Bone Tumor Surgery: Risk Factors and New Preventive Techniques. Cancers 2022, 14, 4527. [Google Scholar] [CrossRef] [Scilit]
  9. Daher, M.; Fares, M.Y.; Gill, S.S.; Boufadel, P.; Jensen, A.R.; Eward, W.C.; Khan, A.Z.; Horneff, J.G.; Abboud, J.A. Allograft-Prosthetic Composite versus Megaprosthesis for Proximal Humerus Reconstruction after Tumor Resection: A Meta-Analysis of Clinical Outcomes. Clin. Shoulder Elb. 2025, 28, 298–305. [Google Scholar] [CrossRef] [Scilit]
  10. Amin, S.N.; Ebeid, W.A. Shoulder Reconstruction after Tumor Resection by Pedicled Scapular Crest Graft. Clin. Orthop. Relat. Res. 2002, 397, 133–142. [Google Scholar] [CrossRef] [Scilit]
  11. Bilgin, S.S. Reconstruction of Proximal Humeral Defects with Shoulder Arthrodesis Using Free Vascularized Fibular Graft. J. Bone Jt. Surg. 2012, 94, e94. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Sirveaux, F. Reconstruction techniques after proximal humerus tumour resection. Orthop. Traumatol. Surg. Res. 2019, 105, S153–S164. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Prządka, M.; Pająk, W.; Kleinrok, J.; Pec, J.; Michno, K.; Karpiński, R.; Baj, J. Advances in 3D Printing Applications for Personalized Orthopedic Surgery: From Anatomical Modeling to Patient-Specific Implants. J. Clin. Med. 2025, 14, 3989. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  14. Basgul, C.; Yu, T.; MacDonald, D.W.; Siskey, R.; Marcolongo, M.; Kurtz, S.M. Structure-Property Relationships for 3D Printed PEEK Intervertebral Lumbar Cages Produced Using Fused Filament Fabrication. J. Mater. Res. 2018, 33, 2040–2051. [Google Scholar] [CrossRef] [Scilit]
  15. Zhao, Y.; Wong, H.M.; Wang, W.; Li, P.; Xu, Z.; Chong, E.Y.W.; Yan, C.H.; Yeung, K.W.K.; Chu, P.K. Cytocompatibility, Osseointegration, and Bioactivity of Three-Dimensional Porous and Nanostructured Network on Polyetheretherketone. Biomaterials 2013, 34, 9264–9277. [Google Scholar] [CrossRef] [Scilit]
  16. Ma, H.; Suonan, A.; Zhou, J.; Yuan, Q.; Liu, L.; Zhao, X.; Lou, X.; Yang, C.; Li, D.; Zhang, Y. PEEK (Polyether-Ether-Ketone) and Its Composite Materials in Orthopedic Implantation. Arab. J. Chem. 2021, 14, 102977. [Google Scholar] [CrossRef] [Scilit]
  17. Sobieraj, M.C.; Kurtz, S.M.; Rimnac, C.M. Notch Sensitivity of PEEK in Monotonic Tension. Biomaterials 2009, 30, 6485–6494. [Google Scholar] [CrossRef] [Scilit]
  18. Toth, J.M.; Wang, M.; Estes, B.T.; Scifert, J.L.; Seim, H.B.; Turner, A.S. Polyetheretherketone as a Biomaterial for Spinal Applications. Biomaterials 2006, 27, 324–334. [Google Scholar] [CrossRef] [Scilit]
  19. Ma, R.; Tang, T. Current Strategies to Improve the Bioactivity of PEEK. Int. J. Mol. Sci. 2014, 15, 5426–5445. [Google Scholar] [CrossRef] [Scilit]
  20. Ceddia, M.; Morizio, A.; Solarino, G.; Trentadue, B.; Ceddia, M.; Morizio, A.; Solarino, G.; Trentadue, B. Evaluation of the Stress-Shielding Effect of a PEEK Knee Prosthesis. A Finite Element Study. Osteology 2025, 5, 24. [Google Scholar] [CrossRef] [Scilit]
  21. Naghavi, S.A.; Lin, C.; Sun, C.; Tamaddon, M.; Basiouny, M.; Garcia-Souto, P.; Taylor, S.; Hua, J.; Li, D.; Wang, L.; et al. Stress Shielding and Bone Resorption of Press-Fit Polyether–Ether–Ketone (PEEK) Hip Prosthesis: A Sawbone Model Study. Polymers 2022, 14, 4600. [Google Scholar] [CrossRef] [Scilit]
  22. Liu, D.; Fu, J.; Fan, H.; Li, D.; Dong, E.; Xiao, X.; Wang, L.; Guo, Z. Application of 3D-Printed PEEK Scapula Prosthesis in the Treatment of Scapular Benign Fibrous Histiocytoma: A Case Report. J. Bone Oncol. 2018, 12, 78–82. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Smolle, M.A.; Andreou, D.; Tunn, P.-U.; Leithner, A. Advances in Tumour Endoprostheses: A Systematic Review. EFORT Open Rev. 2019, 4, 445–459. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  24. Hones, K.M.; Gutowski, C.T.; Srinivasan, R.C.; Wright, J.O.; King, J.J.; Wright, T.W.; Fedorka, C.J.; Marigi, E.M.; Schoch, B.S.; Hao, K.A. Allograft-Prosthetic Composite Reconstruction for Proximal Humerus Bone Loss: A Systematic Review and Meta-Analysis of Outcomes and Complications. JBJS Rev. 2023, 11, e23. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  25. Antal, I.; Szőke, G.; Szendrői, M.; Szalay, K.; Perlaky, T.; Kiss, J.; Skaliczki, G. Functional Outcome and Quality of Life Following Resection of the Proximal Humerus Performed for Musculoskeletal Tumors and Reconstruction Done by Four Different Methods. Musculoskelet. Surg. 2023, 107, 351–359. [Google Scholar] [CrossRef] [Scilit]
  26. Cannon, C.P.; Paraliticci, G.U.; Lin, P.P.; Lewis, V.O.; Yasko, A.W. Functional Outcome Following Endoprosthetic Reconstruction of the Proximal Humerus. J. Shoulder Elb. Surg. 2009, 18, 705–710. [Google Scholar] [CrossRef] [Scilit]
  27. Dubina, A.; Shiu, B.; Gilotra, M.; Hasan, S.A.; Lerman, D.; Ng, V.Y. What Is the Optimal Reconstruction Option after the Resection of Proximal Humeral Tumors? A Systematic Review. Open Orthop. J. 2017, 11, 203–211. [Google Scholar] [CrossRef] [Scilit]
  28. Lädermann, A.; Edwards, T.B.; Walch, G. Arm Lengthening after Reverse Shoulder Arthroplasty: A Review. Int. Orthop. 2014, 38, 991–1000. [Google Scholar] [CrossRef] [Scilit]
  29. Trovarelli, G.; Cappellari, A.; Angelini, A.; Pala, E.; Ruggieri, P. What Is the Survival and Function of Modular Reverse Total Shoulder Prostheses in Patients Undergoing Tumor Resections in Whom an Innervated Deltoid Muscle Can Be Preserved? Clin. Orthop. Relat. Res. 2019, 477, 2495–2507. [Google Scholar] [CrossRef] [Scilit]
  30. Streitbuerger, A.; Henrichs, M.; Gosheger, G.; Ahrens, H.; Nottrott, M.; Guder, W.; Dieckmann, R.; Hardes, J. Improvement of the Shoulder Function after Large Segment Resection of the Proximal Humerus with the Use of an Inverse Tumour Prosthesis. Int. Orthop. 2015, 39, 355–361. [Google Scholar] [CrossRef] [Scilit]
  31. Grosel, T.W.; Plummer, D.R.; Everhart, J.S.; Kirven, J.C.; Ziegler, C.L.; Mayerson, J.L.; Scharschmidt, T.J.; Barlow, J.D. Reverse Total Shoulder Arthroplasty Provides Stability and Better Function than Hemiarthroplasty Following Resection of Proximal Humerus Tumors. J. Shoulder Elb. Surg. 2019, 28, 2147–2152. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Ozeki, K.; Masuzawa, T.; Aoki, H. Fabrication of Hydroxyapatite Thin Films on Polyetheretherketone Substrates Using a Sputtering Technique. Mater. Sci. Eng. C 2017, 72, 576–582. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Rodzeń, K.; Sharma, P.K.; McIlhagger, A.; Mokhtari, M.; Dave, F.; Tormey, D.; Sherlock, R.; Meenan, B.J.; Boyd, A. The Direct 3D Printing of Functional PEEK/Hydroxyapatite Composites via a Fused Filament Fabrication Approach. Polymers 2021, 13, 545. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  34. Messina, F.; Meschini, C.; Oliva, M.S.; Caredda, M.; Bove, A.; Rovere, G.; Ziranu, A. Megaprosthetic Reconstruction for Pathological Proximal Humerus Fractures: Infection Rates, Prevention Strategies, and Functional Outcomes—A Narrative Review. J. Clin. Med. 2025, 14, 7672. [Google Scholar] [CrossRef] [Scilit]
  35. Gregori, P.; Perricone, G.; Franceschetti, E.; Giurazza, G.; Papalia, G.F.; Zà, P.; Papalia, R. Allograft Prosthesis Composite (APC) for Proximal Humeral Bone Loss: Outcomes and Perspectives. J. Pers. Med. 2023, 13, 1301. [Google Scholar] [CrossRef] [Scilit]
  36. D’Arienzo, A.; Ipponi, E.; Ruinato, A.D.; De Franco, S.; Colangeli, S.; Andreani, L.; Capanna, R. Proximal Humerus Reconstruction after Tumor Resection: An Overview of Surgical Management. Adv. Orthop. 2021, 2021, 5559377. [Google Scholar] [CrossRef] [Scilit]
  37. Beltrami, G.; Rajan, S.; Nucci, A.M.; Galeotti, A.; Guido, D.; Campanacci, D.; Innocenti, M. Biological Prosthesis (Hollow 3D-Printed Titanium Custom-Made Prosthesis and Bone Graft) for Humeral Reconstruction in Pediatric Oncologic Patients: Surgical Indications and Results. Bioengineering 2023, 10, 1371. [Google Scholar] [CrossRef] [Scilit]
  38. Ferlauto, H.R.; Wickman, J.R.; Lazarides, A.L.; Hendren, S.; Visgauss, J.D.; Brigman, B.E.; Anakwenze, O.A.; Klifto, C.S.; Eward, W.C. Reverse total shoulder arthroplasty for oncologic reconstruction of the proximal humerus: A systematic review. J. Shoulder Elb. Surg. 2021, 30, e647–e658. [Google Scholar] [CrossRef] [Scilit]
Figure 1. Preoperative imaging and planning for reconstruction and virtual tumor resection. (A) Clinical photograph of the patient’s left shoulder. (BD) Measurements of humeral length and width on both sides.
Figure 1. Preoperative imaging and planning for reconstruction and virtual tumor resection. (A) Clinical photograph of the patient’s left shoulder. (BD) Measurements of humeral length and width on both sides.
Bioengineering 13 00253 g001
Figure 2. Computer-aided design and fabrication of the 3D-printed PEEK implant. (A) 3D reconstruction of both humeri shows similar lengths for contralateral mirroring. (B) Residual humeral bone stock after resection for stem length and fixation planning. (C) Virtual assembly confirms overlap, alignment, and restored length. (D) Implant dimensions: segment and intramedullary stem. (E) Implant features include a junctional collar and proximal suture tunnels for stability and soft-tissue reattachment. (F) Fabricated implant showing the head–shaft–stem construct.
Figure 2. Computer-aided design and fabrication of the 3D-printed PEEK implant. (A) 3D reconstruction of both humeri shows similar lengths for contralateral mirroring. (B) Residual humeral bone stock after resection for stem length and fixation planning. (C) Virtual assembly confirms overlap, alignment, and restored length. (D) Implant dimensions: segment and intramedullary stem. (E) Implant features include a junctional collar and proximal suture tunnels for stability and soft-tissue reattachment. (F) Fabricated implant showing the head–shaft–stem construct.
Bioengineering 13 00253 g002
Figure 3. Intraoperative photographs demonstrating wide tumor resection and implantation of the 3D-printed PEEK prosthesis. (A) shows the use of a patient-specific instrument (PSI) to determine the tumor resection level during surgery; (B) reveals the resected specimen after removal; In (C,D), the PEEK implant is shown after implantation in the patient’s humerus, viewed from two different positions.
Figure 3. Intraoperative photographs demonstrating wide tumor resection and implantation of the 3D-printed PEEK prosthesis. (A) shows the use of a patient-specific instrument (PSI) to determine the tumor resection level during surgery; (B) reveals the resected specimen after removal; In (C,D), the PEEK implant is shown after implantation in the patient’s humerus, viewed from two different positions.
Bioengineering 13 00253 g003
Figure 4. Radiographic follow-up of the patient at 6 months postoperatively. (A,B) show the patient’s anteroposterior and lateral radiographs; (C) shows the postoperative MRI obtained during follow-up evaluation.
Figure 4. Radiographic follow-up of the patient at 6 months postoperatively. (A,B) show the patient’s anteroposterior and lateral radiographs; (C) shows the postoperative MRI obtained during follow-up evaluation.
Bioengineering 13 00253 g004
Table 1. Patient characteristics.
Table 1. Patient characteristics.
No.Age (Years)SexDiagnosisStagePathologic FractureFollow-Up (Months)
141MaleOsteosarcomaIIBNo112
226MaleChondrosarcomaIIBNo74
313MaleEwing sarcomaIIBNo62
458MaleChondrosarcomaIIBNo52
57FemaleOsteosarcomaIIBYes49
612MaleOsteosarcomaIIBYes19
79FemaleOsteosarcomaIIBNo24
Table 2. Manufacturing parameters.
Table 2. Manufacturing parameters.
ParameterValue
Printing technologyFDM
MaterialPure medical-grade PEEK
Nozzle temperature>400 °C
Bed temperature130 °C
Build chamberHeated
Layer height0.10 mm
Infill percentage90–100%
Printing speed30 mm/s
Post-processingAnnealing 130 °C for 2 h
Mean geometric deviation<2 mm
Fixation methodScrew fixation to diaphyseal humerus, augmented with plate and screws
Soft tissue attachmentIntegrated suture tunnels
Implant weight~1.3 g/cm3
Table 3. Oncologic outcomes.
Table 3. Oncologic outcomes.
No.Local RecurrenceImplant FractureMetastasisLimb Salvage
1YesNoNoneYes
2YesNoNoneYes
3NoYesNoneYes
4NoNoNoneYes
5NoNoNoneYes
6NoNoNoneYes
7NoNoNoneYes
Table 4. Functional outcomes.
Table 4. Functional outcomes.
No.MSTSFlexion (°)Extension (°)Abduction (°)Internal Rotation (°)External Rotation (°)
1214520309080
225
32445104080
422
5254545309030
6222020258070
7222015207060
Table 5. Summary results.
Table 5. Summary results.
OutcomeValue
Mean MSTS ± SD23.0 ± 1.6
Mean Flexion (°)35.0
Mean Extension (°)22.0
Mean Abduction (°)29.0
Mean Internal Rotation (°)82.0
Mean External Rotation (°)60.0
Implant Survival Rate85.7% (6/7 with no fracture)
Local Recurrence Rate28.6% (2/7 patients)
Limb Salvage Rate100%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Thanh, T.D.; Huy, L.D.; Trung, N.D.; Anh, L.N.; Thang, V.D.; Phuc, L.H.; Hung, L.T.; Nang, V.S.Q.; Hieu, P.T.; Sang, N.T.Q.; et al. Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study. Bioengineering 2026, 13, 253. https://doi.org/10.3390/bioengineering13020253

AMA Style

Thanh TD, Huy LD, Trung ND, Anh LN, Thang VD, Phuc LH, Hung LT, Nang VSQ, Hieu PT, Sang NTQ, et al. Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study. Bioengineering. 2026; 13(2):253. https://doi.org/10.3390/bioengineering13020253

Chicago/Turabian Style

Thanh, Tran Duc, Le Duc Huy, Nguyen Duc Trung, Luong Nhat Anh, Vu Duc Thang, Luu Huu Phuc, Le The Hung, Vo Sy Quyen Nang, Pham Trung Hieu, Nguyen Tran Quang Sang, and et al. 2026. "Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study" Bioengineering 13, no. 2: 253. https://doi.org/10.3390/bioengineering13020253

APA Style

Thanh, T. D., Huy, L. D., Trung, N. D., Anh, L. N., Thang, V. D., Phuc, L. H., Hung, L. T., Nang, V. S. Q., Hieu, P. T., Sang, N. T. Q., Quang, D. M., & Dung, T. T. (2026). Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study. Bioengineering, 13(2), 253. https://doi.org/10.3390/bioengineering13020253

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop