Next Article in Journal
Effects of the Maillard Reaction on the Structural and Functional Properties of Camel Whey Protein
Previous Article in Journal
Factors Influencing Consumer Behavior and Purchasing Decisions Regarding Mud Crabs (Scylla paramamosain) in the Major Cities of Vietnam
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Hydrophobic Ratiometric Fluorescent Indicator Film Using Electrospinning for Visual Monitoring of Meat Freshness

1
Agricultural Product Processing and Storage Lab, School of Food and Biological Engineering, Jiangsu University, Zhenjiang 212013, China
2
Wencheng Institution of Modern Agriculture and Healthcare Industry, Wencheng, Wenzhou 325300, China
3
School of Electrical Engineering, Yancheng Institute of Technology, Yancheng 224051, China
*
Authors to whom correspondence should be addressed.
Foods 2025, 14(13), 2200; https://doi.org/10.3390/foods14132200
Submission received: 19 May 2025 / Revised: 17 June 2025 / Accepted: 20 June 2025 / Published: 23 June 2025
(This article belongs to the Special Issue Novel Smart Packaging in Foods)

Abstract

A ratiometric fluorescent film with high gas sensitivity and stability was developed using electrospinning technology for monitoring food spoilage. 5(6)-Carboxyfluorescein (5(6)-FAM) was used as the indicator, combined with the internal reference Rhodamine B (RHB), to establish a composite ratiometric fluorescent probe (FAM@RHB). The hydrophobic fluorescent films were fabricated by incorporating FAM@RHB probes into polyvinylidene fluoride (PVDF) at varying molar ratios through electrospinning. The FR-2 film with a 2:8 ratio of 5(6)-FAM to RHB exhibited the best performance, demonstrating excellent hydrophobicity with a water contact angle (WCA) of 113.45° and good color stability, with a ΔE value of 2.05 after 14 days of storage at 4 °C. Gas sensitivity tests indicated that FR-2 exhibited a limit of detection (LOD) of 0.54 μM for trimethylamine (TMA). In the application of monitoring the freshness of pork and beef at 4 °C, the fluorescence color of the FR-2 film significantly changed from orange–yellow to green, enabling the visual monitoring of meat freshness. Hence, this study provides a new approach for intelligent food packaging.

1. Introduction

Meat is a crucial nutritional source, rich in proteins, fats, and minerals for human nutrition [1]. However, it easily undergoes biochemical reactions like microbial contamination, enzymatic reactions, and lipid oxidation, which compromise its freshness and lead to spoilage [2,3,4]. Total volatile basic nitrogen (TVB-N) is a crucial indicator of meat spoilage, mainly composed of volatile substances like ammonia (NH3), dimethylamine (DMA), and trimethylamine (TMA) [2,5,6]. Smart packaging can conduct real-time monitoring and feedback on the volatile compounds generated during the deterioration of food. It can dynamically indicate the freshness of food in an intuitive way, such as through color changes, making it convenient for both producers and consumers to use [7,8,9,10,11,12].
Freshness indicators are functional labels that intuitively reflect food freshness through signal changes like color and electrochemical indicators, including gas or pH-sensitive indicators [13], microbial indicators [14], time–temperature indicators [15], and so on. Colorimetric indicators are more convenient to use compared to electrochemical indicators because they can directly indicate freshness through color changes. Their responsive properties are harnessed to monitor spoilage: for example, decomposing meats and fish release volatile amines (e.g., trimethylamine and putrescine) that trigger distinct chromatic or fluorescent shifts of colorimetric indicators. These visual markers provide intuitive, real-time feedback on amine concentration changes, enabling rapid freshness evaluation without complex instrumentation.
Fluorescence sensors, known for their simplicity, cost-effectiveness, and visual output, are increasingly being integrated into smart packaging solutions [16,17,18,19]. However, traditional monochromatic fluorescent probes, which operate on a simple “off-on” mechanism, suffer from limitations such as low sensitivity, poor visual differentiation, and practical portability issues [4,20,21,22]. These probes are also vulnerable to environmental and instrumental interference, and the subtle changes in single-color brightness are often imperceptible to the human eye [4,16,23]. Additionally, fluorescent indicators are prone to aggregation quenching, and the indicator films suffer from low self-stability in the packaging environment of high-humidity meat products. These issues significantly limit the practical prospects of these fluorescent indicator films.
In contrast, ratiometric fluorescent sensors that utilize two luminophores (one indicator and one internal reference) possess superior self-calibration capabilities and exhibit enhanced sensitivity and accuracy [24,25,26,27]. Many studies have confirmed that ratiometric fluorescent probes can provide built-in self-calibration by calculating the intensity ratio of two fluorescent signals, thereby enabling more accurate quantification [28,29,30,31,32].
Rhodamine B (RHB), a cost-effective fluorescent dye, exhibits red fluorescence with a high quantum yield, strong absorption coefficient, pH-resistant fluorescence, and stable chemical properties, making it an ideal self-reference signal [33,34]. Some scholars used Rhodamine B as an internal reference, salicylamide as a pH indicator, and polyvinyl alcohol as the base material to prepare a pH-responsive intelligent packaging system for the real-time monitoring of the freshness of seafood [35]. Some scholars used Rhodamine B (internal reference) and fluorescein isothiocyanate (indicator) to detect histamine in raw meat, a combination that exhibited a notable color transition from yellow to green [36]. In addition, 5(6)-Carboxyfluorescein (5(6)-FAM) is a fluorescent indicator with high sensitivity and stability, featuring favorable optical properties, ease of biomolecule conjugation, and low cytotoxicity, which make it ideal for biomedical applications [37].
Electrospinning technology has been widely used in the preparation of polymer fiber films. The intelligent indicator films developed through electrospinning possess advantages such as high encapsulation efficiency, adjustable porosity, easy manipulation of chemical compositions, and flexible material selection. The porous network of electrospun nanofibers increases the number of active sites for interaction with target molecules, thus improving the sensitivity of the films [38,39]. Meanwhile, the semi-embedded hydrophobic matrix prepared by electrospinning technology can enhance the stability of the indicator films in meat packaging. However, there are few studies that combine fluorescent sensors with electrospinning to develop intelligent packaging for monitoring food freshness [40,41,42,43].
Our recent study successfully developed a ratiometric fluorescent sensor using as-synthesized carbon dots as the probes [44]. In comparison, this study employed both Rhodamine B and 5(6)-FAM as probes due to their commercial availability, making s the fluorescent sensor more conducive to commercialization.
This study involved the development of a ratiometric fluorescent probe, FAM@RHB, by combining RHB as the internal reference and 5(6)-FAM as the indicator. The optimal ratio of these two components was systematically determined. Subsequently, FAM@RHB was incorporated into PVDF nanofibers using electrospinning technology to develop and characterize a hydrophobic ratiometric fluorescent film. The sensitivity of the indicator film to trimethylamine and its stability were the primary focus of this study. Finally, it was applied for monitoring the freshness of pork and beef.

2. Materials and Methods

2.1. Materials

5(6)-Carboxyfluorescein (5(6)-FAM, purity: 95%), Rhodamine B (RHB, purity: 99%), and ammonia solution (NH3) (25–28 wt%) were obtained from Shanghai Macklin Biochemical Technology Co., Ltd. (Shanghai, China). Polyvinylidene fluoride (PVDF, purity: ≥99.9%) was supplied from Shanghai Yuanye Bio-Technology Co., Ltd. (Shanghai, China). N,N-Dimethylformamide (DMF, purity: ≥99.5%) and magnesium oxide (MgO, purity: 99%) were purchased from Aladdin Biochemical Technology Co., Ltd. (Shanghai, China). Acetone (purity: ≥99.5%), boric acid (H3BO3, purity: ≥99.5%), and hydrochloric acid (HCl, 36%~38%) were acquired from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Deionized water was used throughout the experiments. All chemicals were of analytical grade and used as received without further purification.

2.2. Preparation of Ratiometric Fluorescent Probes

Initially, 10 mg of 5(6)-FAM was dissolved in 10 mL of deionized water under continuous magnetic stirring at room temperature for 10 min and then ultrasonicated for 5 min, yielding a homogeneous yellow–green solution. Simultaneously, 10 mg of RHB was dissolved in 10 mL of absolute ethanol through magnetic stirring and then ultrasonicated for 10 min, resulting in a uniform orange solution.
The process of optimizing the ratio of 5(6)-FAM to RHB was as follows: firstly, the 5(6)-FAM and RHB solutions were mixed at varying volume ratios (1:9, 2:8, 3:7, 4:6, and 5:5) for the preparation of ratiometric fluorescent probes. A 10 μL aliquot of the ratiometric fluorescent probe was diluted with 3 mL of ultrapure water. A specific volume of TMA solution was then added to the mixture, which was thoroughly mixed and allowed to react for 3 min. The fluorescence spectra of the FAM@RHB mixtures were recorded using a fluorescence spectrophotometer both before and after the reaction. The parameters were set as follows: excitation wavelength of 490 nm, emission wavelength range of 490–650 nm, scanning speed of 1000 nm/min, excitation bandwidth and emission bandwidth of 10 nm, and gain of 7 steps [45]. By comparing the fluorescence intensity ratios of the two emission peaks before and after the reaction, the FAM@RHB ratiometric fluorescent probe with the highest degree of reaction was identified.

2.3. Preparation of Electrospun Ratiometric Fluorescent Films

To create the electrospinning substrate solution, 1.5 g of PVDF powder was dissolved in 10 mL of a binary solvent system consisting of DMF and acetone with a volume ratio of 4:1. The mixture was magnetically stirred at 40 °C for 3 h to obtain a transparent PVDF polymer solution. Subsequently, 2% (w/v) of the prepared FAM@RHB fluorescent probe solutions were individually incorporated into the PVDF solution [8]. Each mixture was subjected to magnetic stirring for 30 min followed by 30 min of ultrasonication to ensure complete homogenization and bubble removal, yielding clear and transparent red-colored electrospinning solutions.
The ratiometric fluorescent films were fabricated using an electrospinning apparatus. The polymer solution was loaded into a 10 mL syringe equipped with a stainless steel needle (0.91 mm outer diameter, 0.58 mm inner diameter). The electrospinning parameters were optimized as follows: a positive voltage of 15 kV, a negative voltage of −3 kV, a chamber temperature of 35 °C, a relative humidity of 45%, a needle-to-collector distance of 20 cm, a solution flow rate of 0.001 mm/s, and a receiver rotation speed of 20 r/min. To enable seamless film collection, the drum receiver was lined with silicone-coated greaseproof paper, ensuring optimal deposition of the electrospun fibers under the high-voltage electrostatic field [46]. The resulting fluorescent films were designated as FR-1, FR-2, FR-3, FR-4, and FR-5, corresponding to the respective volume ratios of 5(6)-FAM to RHB (1:9, 2:8, 3:7, 4:6, and 5:5) incorporated in each film.

2.4. Scanning Electron Microscopy (SEM) of Indicator Films

The samples were trimmed into appropriate sizes and mounted onto SEM stubs using a conductive adhesive, ensuring flat surface attachment. Prior to imaging, the samples were sputter-coated with a thin layer of gold for 5 min to enhance conductivity [47]. The surface morphology and fiber architecture were examined using field emission scanning electron microscopy (S-4800, Hitachi High Technologies Corporation, Tokyo, Japan) at an accelerating voltage of 5 kV. Fiber diameter distribution was quantitatively analyzed using Nano Measurer 1.2 software.

2.5. Laser Confocal Image of the Indicator Film

For confocal microscopy analysis, the indicator films were precisely sectioned into thin strips and mounted onto glass slides. The specimens were meticulously placed at the central area of the slide and then sealed with a coverslip to guarantee consistent flatness across the sample surface [48]. The edges were secured with laboratory tape to prevent movement during imaging. The prepared slides were then inverted and positioned on the microscope stage for imaging. Fluorescence imaging was performed using a laser scanning confocal microscope (TCS SP5, Leica, Germany) with an excitation wavelength of 488 nm.

2.6. Fourier Transform Infrared Spectroscopy (FTIR) of Indicator Films

The chemical composition of the indicator films was characterized using FTIR in attenuated total reflectance (ATR) mode [49]. Spectra were acquired over a wavenumber range of 525–4000 cm−1 with a spectral resolution of 4 cm−1. Each measurement was performed with 32 scans at room temperature to ensure an optimal signal-to-noise ratio. Prior to analysis, the ATR crystal was carefully cleaned with ethanol, and background spectra were collected. The spectra that were obtained were processed with baseline correction and normalization using the instrument-specific software (omnic 8.2), facilitating comparative analysis.

2.7. Water Contact Angle (WCA) of the Indicator Film

Static water contact angle measurements were conducted to assess the surface hydrophobicity of the indicator films [50]. Film samples were precisely cut into 20 × 20 mm squares and mounted onto glass slides using double-sided adhesive tape, ensuring a flat and wrinkle-free surface. The prepared samples were placed on a leveled stage of the contact angle goniometer. A 5 μL droplet of deionized water was carefully dispensed onto the film surface using a precision microsyringe. The droplet profile was captured using a high-speed camera equipped with image analysis software. The WCA was determined using the Young–Laplace fitting method, with measurements taken at three different locations on each sample to ensure reproducibility. All measurements were conducted under ambient conditions (25 ± 1 °C, 50 ± 5% relative humidity).

2.8. Stability of Indicator Films

The color stability of the indicator films was systematically evaluated through controlled storage experiments. Film samples were stored in a temperature-controlled chamber maintained at 4 ± 0.5 °C for a duration of 14 days. Colorimetric analysis was performed at two-day intervals to monitor any chromatic changes. For fluorescence imaging, the films were placed in a UV chamber equipped with 365 nm excitation and photographed using a digital camera with fixed parameters. The camera position and imaging conditions were rigorously maintained throughout the experiment to ensure consistency and minimize experimental variability. The L* (lightness), a* (red-to-green), and b* (blue-to-yellow) values of the photos were using a calibrated imaging system [51]. Triplicate measurements were performed for each sample, and the mean values were calculated to ensure statistical reliability. The total color difference (ΔE) between initial and stored samples was calculated using the following equation:
Δ E = Δ L * 2 + Δ a * 2 + Δ b * 2
where ΔL* = L* − L0*, Δa = a* − a0*, Δb = b* − b0*. L*, a*, and b* are the color parameters of the indicator film after a certain storage time. L0*, a0*, and b0* are the initial color parameters of the indicator film.

2.9. Response of Indicator Films to TMA

TMA, a well-established biomarker for meat spoilage, was used to evaluate the gas-sensing performances of the developed indicator films [52]. A 1 × 1 cm film sample was placed in a sealed test chamber maintained under controlled conditions (25 °C, 60% relative humidity). A microliter syringe was used to inject TMA solution into the chamber, and the system was allowed to stand for 60 min to ensure a complete reaction. The concentrations of TMA in the testing chamber were 0, 2.86, 5.71, 8.57, 14.28, 20, 28.57, 57.14, 85.71, and 142.86 μM, respectively. Triplicate parallel experiments were carried out to ensure reproducibility, and the fluorescence color parameters of the indicator films were collected. The ΔE values were calculated according to Equation 2.1, and the average value was taken as the final result. The following is the formula used for calculating the concentration of TMA in the testing chamber:
C = W S   V S   ρ S M   V
where C (mol/L) is the concentration of the analyte in the test chamber; ρS is the density of the analyte (g/mL); VS is the volume of the analyte (mL); Ws is the mass fraction of the analyte; M is the molar mass of the analyte (g/mol); V is the volume of the reaction vessel (L).
The limit of detection (LOD) of the indicator film can be calculated by using the following formula [53]:
LOD = 3 σ N
where σ is the standard deviation of 13 replicate blank measurements, and N is the absolute value of the slope of the calibration curve.

2.10. Application of Indicator Films for Livestock Meat Freshness Monitoring

For the same batch of purchased meat, one part was used for application testing, while the other part was utilized to determine total volatile basic nitrogen (TVB-N). Both beef (loin) and pork (loin) were sampled from the longissimus dorsi muscle. Visible fat and connective tissues were excised, and sterile stainless steel molds were employed to cut the meat into 60 ± 1 g cuboids, ensuring uniform muscle fiber orientation.
FR-2 fluorescent indicator films (1.5 × 1.5 cm) were affixed to the interior top surface of each container. The thickness of the applied FR-2 film was approximately 126 ± 2 μm. The packaged samples were stored in a temperature-controlled refrigerator at 4 °C for 7 days. The fluorescence response was monitored daily using a UV chamber (365 nm excitation), with digital images captured at 24 h intervals using a standardized camera setup. To assess the effectiveness of the indicator film in evaluating meat freshness, the TVB-N values of pork and beef were measured. The measurements were carried out according to the Chinese National Standard GB 5009.228-2016 [54] and previous research methods [55]. To ensure that the two groups of samples were as identical as possible, we used large cuts of pork and beef from the same source. On the first day, the large cuts of pork and beef were sliced into smaller pieces of a uniform size. Portions of the pork and beef pieces were placed into packaging boxes equipped with fluorescent indicator films, while the remaining portions were placed into identical packaging boxes without indicator films. Both groups were stored under the same conditions. Samples for TVB-N testing were taken from the packaging boxes without indicator films.

2.11. Statistical Analysis

All experiments were repeated three times and the results were averaged over the three times. Significant differences between data were determined using Duncan’s multiple range test, defining p < 0.05 as significant. Graphs were plotted using IBM SPSS Statistics 25 and Origin 2019 analysis.

3. Results and Discussion

3.1. Optical Properties of 5(6)-FAM and RHB

Figure 1 illustrates the fluorescence emission spectra of 5(6)-FAM and RHB under varying excitation wavelengths. The maximum emission intensity of 5(6)-FAM was observed at an excitation wavelength of 490 nm, with a corresponding emission peak at 516 nm. Notably, the emission peak positions of 5(6)-FAM remained constant across excitation wavelengths ranging from 450 nm to 550 nm. Similarly, as shown in Figure 1B, RHB exhibited its maximum fluorescence intensity at an excitation wavelength of 550 nm, with an emission peak at 580 nm. The emission characteristics of RHB demonstrated wavelength independence within the excitation range of 500 nm to 600 nm. This spectral behavior can be attributed to the fundamental principles of fluorescence emission, where π-electrons transition from the lowest vibrational level of the first excited state to various vibrational levels of the ground state. The consistent emission peak positions, independent of excitation wavelength, confirm the potential of 5(6)-FAM and RHB as reliable components for ratiometric fluorescent probes. Given that 5(6)-FAM functions as the TMA-responsive component in the FAM@RHB ratiometric fluorescent probe system, 490 nm was identified as the optimal excitation wavelength for subsequent experiments. This selection ensures maximum sensitivity while maintaining the ratiometric characteristics of the probe system [56].

3.2. Construction and Ratio Optimization of FAM@RHB Fluorescent Probe

To identify the optimal FAM@RHB probe ratio demonstrating maximal sensitivity to TMA, various probe formulations were prepared with 5(6)-FAM to RHB volume ratios of 1:9, 2:8, 3:7, 4:6, and 5:5. The TMA responsiveness of these probes was evaluated using a 20 μM TMA solution, as illustrated in Figure 2. At the 1:9 ratio, the fluorescence intensity at 516 nm (F516nm) increased from 64 to 222, while the fluorescence intensity at 580 nm (F580nm) remained almost unchanged upon TMA exposure (Figure 2A), with a corresponding ratiometric fluorescence difference (F516nm/F580nm) of 0.35 before and after the reaction (Figure 2F). This limited responsiveness can be attributed to the relatively low concentration of 5(6)-FAM, the TMA-sensitive component, in the probe formulation.
The most pronounced response was observed at the 2:8 ratio, where F516nm increased from 151 to 614 following TMA exposure. As shown in Figure 2B,F, this formulation exhibited the maximum ratiometric fluorescence difference (F516nm/F580nm) of 0.94. Interestingly, a further increase in the 5(6)-FAM proportion resulted in diminished responsiveness, as evidenced by gradually decreasing F516nm/F580nm differences (Figure 2C–F). This phenomenon likely reflects the stoichiometric requirements of the reaction, where higher indicator concentrations necessitate proportionally greater TMA quantities to achieve equivalent response levels, consequently reducing the apparent sensitivity of the probe.

3.3. UV–Vis Spectra of FAM@RHB

The ultraviolet–visible (UV–Vis) absorption spectra of 5(6)-FAM and RHB are presented in Figure 3. The absorption spectrum of 5(6)-FAM can be categorized into two distinct regions: the ultraviolet (UV) region and the visible region. A significant portion of the absorption is observed below 300 nm, a characteristic feature of this fluorescein derivative. Additionally, 5(6)-FAM exhibits minor absorption in the visible region, with absorption bands observed at 452 nm and 480 nm, corresponding to the enol and keto forms of fluorescein, respectively [57]. The absorption peak at 230 nm is attributed to the π–π* electronic transition of the ester group [58]. The presence of these distinct absorption features in the visible region is particularly significant for the development of optical sensors, as it enables selective excitation of the fluorophore within the visible spectrum. As shown in Figure 3, RHB displays characteristic absorption features in both UV and visible regions. RHB exhibits a prominent absorption band in the visible region at 554 nm, which is primarily attributed to the C=N and C=O structures within its conjugated system. Additionally, RHB shows absorption peaks in the UV region at 258 nm and 352 nm mainly originating from its benzene ring structure [59]. These absorption features demonstrate RHB’s strong light-absorbing properties across a broad spectral range, making it suitable for various photochemical applications.

3.4. FAM@RHB Assay for TMA

During meat storage, microbial growth is the primary factor driving gradual spoilage. This process is accompanied by the generation of a range of characteristic spoilage gases, including TMA and NH3, which are widely recognized as key indicators for evaluating meat freshness [60]. Therefore, TMA was selected as a representative gas to evaluate the fluorescent color response capability of the FAM@RHB probe.
Figure 4A demonstrates the TMA-responsive characteristics of the FAM@RHB probe. As TMA concentration increased from 1.67 to 40 μM, F516nm progressively increased, while F580nm remained nearly constant. As shown in Figure 4D, with increasing TMA concentration, the FAM@RHB fluorescent probe exhibited a progressive color shift from red to orange and finally to light green under 365 nm UV irradiation, consistent with the variations in the emission peak intensity of the fluorescence spectrum. Under natural light, a distinct red-to-orange transition was evident. With increasing TMA concentration, the ratiometric fluorescence values (F516nm/F580nm) exhibited a strong linear correlation with TMA concentration (y = 0.079x + 0.062, R2 = 0.980), as shown in Figure 4B. These results confirm the probe’s excellent TMA detection capability.

3.5. Microstructure of the Indicator Film

Figure 5A presents the microscopic morphology of the indicator films. All films exhibited a three-dimensional network structure composed of interwoven nanofibers with rough surfaces, attributed to the polymer characteristics and electrospinning conditions. This surface roughness could enhance the gas sensitivity of films by increasing the effective contact area with TMA. Compared with the FR-3, FR-4, and FR-5 indicator films, the FR-1 and FR-2 films exhibited higher porosity and smaller fiber diameters. This phenomenon can be attributed to the higher loading of 5(6)-FAM in the FR-3, FR-4, and FR-5 films, which resulted in an increased number of positively charged hydrogen atoms. These hydrogen atoms may have established electrostatic interactions with the electronegative fluorine atoms on PVDF, consequently modifying the substrate’s physical properties. The FR-2 indicator film exhibited a smaller fiber diameter, providing a higher specific surface area of fibers for its subsequent favorable response to TMA.

3.6. Hydrophobicity of the Indicator Film

The hydrophobicity of the indicator films is closely related to their performance in high-humidity meat packaging applications. Films with stronger hydrophobicity demonstrate enhanced stability in high-humidity environments by preventing the leaching of indicator materials.
The WCA value of the unmodified PVDF film and the five FR indicator films are presented in Figure 6A. The WCA value of the blank PVDF film was 123.60°, which was higher than those of the five FR indicator films. This suggests that the incorporation of the indicator reduced the hydrophobicity of the films. From FR-1 to FR-5, as the RHB content decreased and the 5(6)-FAM content increased, the amount of hydrophilic moieties (for instance, hydroxyl groups) within the indicator films was reduced. Consequently, the indicator film WCA values increased from 99.63° to 121.69°, indicating a gradual enhancement in hydrophobicity. In addition, FR-1 exhibited significantly lower and different hydrophobicity (p < 0.05) when compared to the other four FR indicator films and the blank PVDF film (Figure 6B). A surface with a WCA value greater than 90° is generally considered hydrophobic. Overall, all five indicator films exhibited good hydrophobicity, demonstrating their potential for application in high-humidity meat packaging.

3.7. Laser Confocal Images of the Indicator Films

Figure 7 shows the laser confocal images of the indicator films. In the green channel, the green fluorescence of the FR-5 indicator film was obviously stronger than that of the FR-1 indicator film, while in the red channel, the red fluorescence of the FR-5 indicator film was obviously weaker than that of the FR-1 indicator film, which was due to the difference in fluorescence intensity caused by the gradual increase in the proportion of 5(6)-FAM in the indicator films from FR-1 to FR-5 and the gradual decrease in the proportion of RHB. In addition, according to the fluorescence distribution, it can be observed that the fluorescent probes were evenly loaded into the fibers, without an obvious aggregation phenomenon. In the bright-field image, it can be observed that the polymer fibers were well defined, which made the indicator film have a good porous structure for subsequent gas sensing.

3.8. FTIR Spectral Analysis of the Indicator Film

Figure 8 presents the FTIR spectra of the fluorescent probes RHB and 5(6)-FAM, as well as the FR-2 film and the blank PVDF film. In the FTIR spectrum of 5(6)-FAM, the broad absorption peak observed at 3434 cm−1 is assigned to the O-H stretching vibration. The characteristic absorption peak at 1697 cm−1 corresponds to the C=O stretching vibration of the carbonyl group. Additionally, two distinct bands near 1392 cm−1 are associated with the C-O-C stretching vibration in the ester-based structure [61]; in the IR spectrum of RHB, the peak at 2990 cm−1 is attributed to the C-H bending vibration. The characteristic absorption peak at 1699 cm−1 arises from the C=O stretching vibration of the carbonyl group, while the peak at 759 cm−1 corresponds to the stretching vibration of the aliphatic C-Cl bond. Furthermore, the absorption peak at 1343 cm−1 is assigned to the C-N stretching vibration.
In the blank PVDF and FR-2 films, the characteristic peaks observed at 1175 cm−1 and 1176 cm−1 are assigned to the stretching vibration of the C-F group in fluorocarbons [62], while the peaks at 1412 cm−1 and 1409 cm−1 correspond to the bending vibrations of C=C bonds. Notably, after loading the fluorescent probe FAM@RHB into the PVDF fibers, the characteristic peak at 769 cm−1 is attributed to the stretching vibration of the C-Cl bond in RHB. Additionally, the presence of the characteristic peak at 607 cm−1 in FR-2 is associated with the in-plane bending vibration of the keto structure (C-C=O) in 5(6)-FAM. This observation is consistent with the UV–Vis spectrum of 5(6)-FAM discussed in Section 3.3. Importantly, no new characteristic peaks emerged during the loading process, indicating that no new substances were formed and the original structures of the components remained intact.

3.9. Storage Stability of the Indicator Film

Fluorescent color stability plays a critical role in determining the indication accuracy of the indicator film. Figure 9 illustrates the fluorescence color changes in the indicator films after 14 days of storage at 4 °C. Generally, when ΔE is less than two, no significant color change is discernible to the naked eye [63,64]. In contrast, the FR-1 and FR-2 indicator films exhibited superior stability, with ΔE values of 1.16 and 1.24 after 8 days of storage, respectively. After 14 days of storage, their ΔE values increased only slightly to 1.71 and 2.05, respectively, rendering the color changes nearly invisible to the naked eye. On the other hand, the color differences of the FR-3, FR-4, and FR-5 indicator films were more pronounced, with ΔE values of 2.78, 3.58, and 4.89, respectively. This trend can be attributed to the gradual decrease in RHB content and the corresponding increase in 5(6)-FAM content from FR-1 to FR-5, as RHB demonstrated better photostability than 5(6)-FAM. In this study, all the films showed ΔE values lower than two within 7 days, implying that these films could be used for foods with a shelf life below 7 days.

3.10. Fluorescent Color Response of Indicator Films to TMA

As illustrated in Figure 10A, as the TMA concentration increased, the fluorescence colors of the five indicator films gradually shifted from yellow to yellow–green and finally to green, albeit with varying intensities. Specifically, the FR-1 indicator film initially exhibited an orange–yellow color in the absence of TMA. While the TMA concentration was elevated from 2.86 μM to 142.86 μM, the fluorescence color transitioned from orange–yellow to yellow–green, accompanied by an increase in the ΔE from 0 to 13.87. The FR-1 indicator film initially exhibited an orange–yellow color before reacting with TMA. During the increase in the TMA concentration from 2.86 μM to 142.86 μM, the film’s fluorescence color transitioned from orange–yellow to yellowish–green, accompanied by an increase in the ΔE from 0 to 13.87. However, the overall fluorescence color change remained relatively subtle. This phenomenon may be attributed to the low proportion of the fluorescent probe FAM in the FR-1 indicator film, resulting in its reduced responsiveness to TMA. Similarly, the FR-2 indicator film initially displayed an orange–yellow color in the absence of TMA. However, unlike the FR-1 film, the FR-2 film demonstrated significantly higher sensitivity to TMA. At a TMA concentration of 28.57 μM, the ΔE reached 16.19, and at 142.86 μM, the ΔE value increased to 21.01, with the fluorescence color transitioning from orange to green. In contrast, the FR-3 indicator film exhibited an initial fluorescence color of yellow, which shifted to green at the endpoint of the TMA reaction, corresponding to a ΔE value of 12.79.
The FR-4 and FR-5 indicator films initially exhibited a yellowish–green color, which transitioned to green at the reaction endpoint. At a TMA concentration of 142.86 μM, their ΔE values were 10.56 and 11.8, respectively. This can be explained by the higher content of FAM fluorescent probes in the FR-4 and FR-5 films, which required a greater amount of TMA to trigger a response. As a result, these films demonstrated comparatively poorer responsiveness than the FR-1 and FR-2 indicator films.
Additionally, the linear relationship between the fluorescence color change of the indicator films and the TMA concentration (ranging from 0 to 28.57 μM), as well as the sensitivity of the indicator films to TMA, were investigated. As shown in Figure 10B–F, there was a good linear relation between ΔE and TMA concentration in the range of 0–28.57 μM, with R2 values not less than 0.94. Based on calculations, the LOD values of the FR-1, FR-2, FR-3, FR-4, and FR-5 indicator films were determined to be 0.72, 0.54, 0.90, 1.06, and 1.10 μM, respectively. These results indicated that the FR-2 indicator film presented the best sensitivity to TMA.
Compared with other indicator films in Table 1, the fluorescent sensor developed in this study exhibited a lower LOD value, namely better gas sensitivity, making it suitable for practical application.

3.11. Application of Indicator Film in Livestock Meat Freshness Monitoring

The FR-2 indicator film exhibited excellent hydrophobicity, high stability, and strong sensitivity to TMA, making it an ideal candidate for monitoring the freshness of livestock meat. As shown in Figure 11A, the fluorescence color of the FR-2 film transitioned significantly from orange to green as the storage time increased and the pork and beef gradually spoiled. Furthermore, as illustrated in Figure 11B, by the third day of pork storage, the TVB-N content increased from 9.34 mg/100 g to 14.69 mg/100 g. According to the national standard [74], the maximum TVB-N value for pork is 15 mg/100 g, indicating that the pork on the third day is still safe to consume. However, by day 3.2, the TVB-N reached the critical threshold of 15 mg/100 g. At this point, the ΔE of the FR-2 indicator film was 7.4, and it showed a shift in fluorescence color from orange–yellow to yellow–green, signaling that the pork was no longer suitable for consumption. By the sixth day, the TVB-N value of the pork had increased to 25.88 mg/100 g, far exceeding the national standard, indicating serious spoilage. Concurrently, the fluorescence color of the indicator film turned green, with a ΔE value of 15.75. A similar trend was observed for beef, which reached the national standard limit of 15 mg/100 g on day 4.3. At this stage, the ΔE value of the indicator film was 9.2, and its fluorescence color transitioned from orange–yellow to green. The relationships between the ΔE values of the FR-2 film and the TVB-N values of beef and pork were shown in Figure 11D and Figure 11E, respectively. These results demonstrated that the FR-2 indicator film could effectively provide an early warning of pork and beef spoilage.

4. Conclusions

In this study, a composite ratiometric fluorescent probe was developed using 5(6)-FAM and RHB, which exhibited dual emission peaks at 516 nm and 580 nm under 490 nm excitation. SEM and laser confocal microscopy confirmed the uniform distribution of the fluorescent probes within the hydrophobic electrospun indicator film. The optimal mass ratio of 5(6)-FAM to RHB was determined to be 2:8 to develop the fluorescent film, namely the FR-2 film. The FR-2 film demonstrated superior sensitivity and stability, with an LOD value of 0.54 μM. The film maintained high stability after 14 days of storage at 4 °C, with a minimal change in the ΔE of only 2.05. The FR-2 indicator film used to monitor the freshness of pork and beef stored at 4 °C exhibited a distinct color transition from orange–yellow to green.
These findings highlight the potential of the FR-2 indicator film as a reliable tool for assessing the freshness of livestock meat in practical applications. The indicator film can be directly integrated into the headspace of existing meat packaging lids without direct food contact, responding to volatile compounds released during storage via visible color changes to indicate freshness levels. Unlike traditional indicators, this film requires UV light irradiation for color change observation, enabling freshness grading: consumers can use the included mini UV flashlight for detection, while producers may install fixed UV lamps on production lines for automated monitoring. PVDF offers exceptional chemical inertness, is non-toxic, is water-insoluble, and is free from F or small-molecule organic substance release. Listed by the U.S. FDA as a food-contact material, it is widely applicable in food packaging and beverage pipelines. However, Rhodamine B—a potentially toxic chemical—requires strict safety protocols for industrial and research use. Notably, the indicator film’s non-direct contact with meat products minimizes leakage risks. Future studies may explore whether the 5(6)-FAM to RHB leach from the films to the packaging environment or to the surface of meats.

Author Contributions

Conceptualization, X.Z. and X.M.; methodology, X.Z., X.M., W.S., Y.X., W.S., X.H. and Z.L.; software, X.Z., X.M. and W.S.; validation, X.Z., Y.X. and W.S.; formal analysis, X.Z.; investigation, X.Z., W.B. and X.M.; resources, X.Z., Y.S., X.H. and Z.L.; data curation, X.Z. and X.M.; writing—original draft preparation, X.Z. and X.M.; writing—review and editing, X.Z., X.M., K.W., Z.C., W.Z., B.L. and L.Z.; visualization, T.S.; supervision, X.Z.; project administration, X.Z., Y.S., T.S., X.H. and Z.L.; funding acquisition, X.Z., Y.S., T.S., Q.S., J.Z., X.H. and Z.L. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the National Key Research and Development Program of China, grant numbers 2023YFE0105500 and 2024YFE0117000, the National Natural Science Foundation of China, grant numbers 32102080, 31801631, 1601360061, 32150410347, and 32272407, the Zhejiang Postdoctoral Programs, grant number ZJ2022135, the Postdoctoral project of the Institute of Modern Agriculture and Health Care Industry of Wencheng, grant number 2022NKY05, the Natural Science Foundation of Jiangsu Province, grant numbers BK20220058, BK20200103, and BK2022011, and the Foundation of Jiangsu Specially-Appointed Professors, grant number 202074.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available upon request from the corresponding author. The data are not publicly available due to product development privacy.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Shi, J.Y.; Liu, C.A.P.; Li, Z.H.; Huang, X.W.; Zhai, X.D.; Hu, X.T.; Zhang, X.A.; Zhang, D.; Zou, X.B. Detection of Low Chromaticity Difference Foreign Matters in Soy Protein Meat Based on Hyperspectral Imaging Technology. Spectrosc. Spectr. Anal. 2022, 42, 1299–1305. [Google Scholar] [CrossRef]
  2. Fan, L.; Chen, Y.; Zeng, Y.; Yu, Z.; Dong, Y.; Li, D.; Zhang, C.; Ye, C. Application of visual intelligent labels in the assessment of meat freshness. Food Chem. 2024, 460, 140562. [Google Scholar] [CrossRef] [PubMed]
  3. Sun, Z.; Liang, L.; Yan, X.; Zou, X.; Wang, T.; Liu, X.; Li, J. Detection of Freshness Indexes of Imported Chilled Beef Using Hyperspectral Imaging Technology. Food Sci. 2020, 41, 315–323. [Google Scholar]
  4. Zhang, D.; Wang, Y.; Geng, W.; Liu, H. Rapid detection of tryptamine by optosensor with molecularly imprinted polymers based on carbon dots-embedded covalent-organic frameworks. Sens. Actuators B-Chem. 2019, 285, 546–552. [Google Scholar] [CrossRef]
  5. Lee, E.-J.; Shin, H.-S. Development of a freshness indicator for monitoring the quality of beef during storage. Food Sci. Biotechnol. 2019, 28, 1899–1906. [Google Scholar] [CrossRef]
  6. Shi, T.; Hu, H.; Xiong, Z.; Wang, L.; Yuan, L.; Gao, R. Application and Mechanism of High-Sensitivity Indicator Film for Monitoring Fish Freshness. Food Sci. 2023, 44, 150–158. [Google Scholar]
  7. Hashim, S.B.; Tahir, H.E.; Lui, L.; Zhang, J.; Zhai, X.; Mahdi, A.A.; Ibrahim, N.A.; Mahunu, G.K.; Hassan, M.M.; Xiaobo, Z. Smart films of carbohydrate-based/sunflower wax/purple Chinese cabbage anthocyanins: A biomarker of chicken freshness. Food Chem. 2023, 399, 133824. [Google Scholar] [CrossRef]
  8. Shao, X.; Lin, H.; Wang, Z.; Li, Y.; Chen, Q. Design and application of portable intelligent rice freshness detection system. Food Mach. 2023, 39, 45–52,104. [Google Scholar]
  9. Guo, Z.; Zhang, P.; Li, Z.; Xu, B.; Shi, J.; Zou, X.; Chen, J. Advance of Food Intelligent Storage and Packaging Technology and High-end Equipment. J. Chin. Inst. Food Sci. Technol. 2025, 25, 12–25. [Google Scholar]
  10. Wang, K.; Wang, R.; Li, Y.; Bai, F.; Gao, R.; Wang, J.; Xu, P.; Zhao, Y. Effects of alpha-Tocopherol and Vacuum Packaging on the Quality of Sturgeon Surimi Incorporated with Chicken Meat during Frozen Storage. Food Sci. 2021, 42, 195–204. [Google Scholar]
  11. Zhang, Z.; Zhou, R.; Ke, L.; Li, J.; Jayan, H.; El-Seedi, H.R.; Zou, X.; Guo, Z. Development of multifunctional metal-organic frameworks (MOFs)-based nanofiller materials in food packaging: A comprehensive review. Trends Food Sci. Technol. 2024, 154, 104771. [Google Scholar] [CrossRef]
  12. Kan, J.; Liu, J.; Xu, F.; Yun, D.; Yong, H.; Liu, J. Development of pork and shrimp freshness monitoring labels based on starch/polyvinyl alcohol matrices and anthocyanins from 14 plants: A comparative study. Food Hydrocoll. 2022, 124, 107293. [Google Scholar] [CrossRef]
  13. Zheng, Y.; Gao, H.; Liu, Z.; Li, C.; Feng, X.; Chen, L. Ammonia/pH super-sensitive colorimetric labels based on gellan gum, sodium carboxymethyl cellulose, and dyes for monitoring freshness of lamb meat. Int. J. Biol. Macromol. 2024, 274, 133227. [Google Scholar] [CrossRef] [PubMed]
  14. Yun, X.; Yuan, S.; Shi, S.; Wang, Y.; Liu, L.; Song, L.; Dong, T. Amine-responsive PVA-based fluorescent indicator films incorporating β-Glucan/FITC for visual detection of chilled meat freshness. Food Biosci. 2024, 62, 105584. [Google Scholar] [CrossRef]
  15. Liu, Y.; Li, L.; Yu, Z.; Ye, C.; Pan, L.; Song, Y. Principle, development and application of time-temperature indicators for packaging. Pack. Technol. Sci. 2023, 36, 833–853. [Google Scholar] [CrossRef]
  16. Jia, R.; Tian, W.; Bai, H.; Zhang, J.; Wang, S.; Zhang, J. Amine-responsive cellulose-based ratiometric fluorescent materials for real-time and visual detection of shrimp and crab freshness. Nat. Commun. 2019, 10, 795. [Google Scholar] [CrossRef]
  17. Zhou, J.; Bi, X.; Li, L.; You, T. Research progress of synthesis of carbon dots and fluorescent sensor based on carbon dots for mercury detection. Trans. Chin. Soc. Agric. Eng. 2020, 36, 134–142. [Google Scholar]
  18. Hu, X.T.; Shi, J.Y.; Li, Y.X.; Shi, Y.Q.; Li, W.T.; Zou, X.B. Sensitive Determination of Trypsin in Urine Using Carbon Nitride Quantum Dots and Gold Nanoclusters. Spectrosc. Spectr. Anal. 2019, 39, 2901–2906. [Google Scholar]
  19. Yuan, H.; Li, Y.; Lv, J.; An, Y.; Guan, D.; Liu, J.; Tu, C.; Wang, X.; Zhou, H. Recent Advances in Fluorescent Nanoprobes for Food Safety Detection. Molecules 2023, 28, 5604. [Google Scholar] [CrossRef]
  20. Zhang, X.; Chen, C.; Peng, D.; Zhou, Y.; Zhuang, J.; Zhang, X.; Lei, B.; Liu, Y.; Hu, C. pH-Responsive carbon dots with red emission for real-time and visual detection of amines. J. Mater. Chem. C 2020, 8, 11563–11571. [Google Scholar] [CrossRef]
  21. Yang, X.; Lu, X.; Wang, J.; Zhang, Z.; Du, X.; Zhang, J.; Wang, J. Near-Infrared Fluorescent Probe with a Large Stokes Shift for Detection of Hydrogen Sulfide in Food Spoilage, Living Cells, and Zebrafish. J. Agric. Food Chem. 2022, 70, 3047–3055. [Google Scholar] [CrossRef] [PubMed]
  22. Long, L.; Cao, S.; Jin, B.; Yuan, X.; Han, Y.; Wang, K. Construction of a Novel Fluorescent Probe for On-site Measuring Hydrogen Sulfide Levels in Food Samples. Foods Anal. Methods 2019, 12, 852–858. [Google Scholar] [CrossRef]
  23. Zhou, Z.; Li, C.; He, J.; Hou, X. A dual-color ratiometric fluorescence sensor of biogenic amines with dye encapsulated covalent organic framework for meat freshness. Lwt-Food Sci. Technol. 2024, 209, 116788. [Google Scholar] [CrossRef]
  24. Gui, R.; Jin, H.; Bu, X.; Fu, Y.; Wang, Z.; Liu, Q. Recent advances in dual-emission ratiometric fluorescence probes for chemo/biosensing and bioimaging of biomarkers. Coord. Chem. Rev. 2019, 383, 82–103. [Google Scholar] [CrossRef]
  25. Shi, J.Y.; Li, W.T.; Hu, X.T.; Shi, Y.Q.; Zou, X.B. A New Ratiometric Fluorescence Probe Based on CuNCs and CQDs and Its Application in the Detection of Hg2+. Spectrosc. Spectr. Anal. 2019, 39, 3925–3931. [Google Scholar]
  26. Xing, Y.; Zhu, Y.; Tang, Y.; Mao, Y.; Han, J.; Wang, Y.; Ni, L. Construction and application of a ratiometric fluorescent probe for detecting endogenous ClO~. Chin. J. Anal. Lab. 2020, 39, 772–776. [Google Scholar]
  27. Sun, Y.; Zhai, X.; Zou, X.; Shi, J.; Huang, X.; Li, Z. A ratiometric fluorescent sensor based on silicon quantum dots and silver nanoclusters for beef freshness monitoring. Foods 2023, 12, 1464. [Google Scholar] [CrossRef]
  28. Hu, X.; Cao, H.; Dong, W.; Tang, J. Ratiometric fluorescent sensing of ethanol based on copper nanoclusters with tunable dual emission. Talanta 2021, 233, 122480. [Google Scholar] [CrossRef]
  29. Li, W.; Shi, Y.; Hu, X.; Li, Z.; Huang, X.; Holmes, M.; Gong, Y.; Shi, J.; Zou, X. Visual detection of nitrite in sausage based on a ratiometric fluorescent system. Food Control 2019, 106, 106704. [Google Scholar] [CrossRef]
  30. Long, L.; Han, Y.; Yuan, X.; Cao, S.; Liu, W.; Chen, Q.; Wang, K.; Han, Z. A novel ratiometric near-infrared fluorescent probe for monitoring cyanide in food samples. Food Chem. 2020, 331, 127359. [Google Scholar] [CrossRef]
  31. Fang, X.; Liu, T.; Xue, C.; Xue, G.; Wu, M.; Liu, P.; Hammock, B.D.; Lai, W.; Peng, J.; Zhang, C. Competitive ratiometric fluorescent lateral flow immunoassay based on dual emission signal for sensitive detection of chlorothalonil. Food Chem. 2024, 433, 137200. [Google Scholar] [CrossRef]
  32. Chen, X.; Zhao, C.; Zhao, Q.; Yang, Y.; Yang, S.; Zhang, R.; Wang, Y.; Wang, K.; Qian, J.; Long, L. Construction of a Colorimetric and Near-Infrared Ratiometric Fluorescent Sensor and Portable Sensing System for On-Site Quantitative Measurement of Sulfite in Food. Foods 2024, 13, 1758. [Google Scholar] [CrossRef]
  33. Liu, Y.; Jiang, W.; Yang, Z.; Tong, F.; Wang, L.; Zhu, L.; Yu, Z.; Zheng, M.; Xiao, Y.; Zhou, Y. Intelligent biogenic amine-responsive fluorescent label for visual and real-time monitoring of seafood freshness. Food Chem. 2022, 388, 132963. [Google Scholar] [CrossRef]
  34. Han, G.; Cai, J.; Yang, L.; Li, X.; Wang, X. Fluorescent Paper Based on CQDs/Rhodamine B: A Ratio and Sensitive Detection Platform for On-Site Fe3+ Sensing. Molecules 2024, 29, 1658. [Google Scholar] [CrossRef] [PubMed]
  35. Xia, F.; Shi, W.; Yu, Y.; Jiang, C.; Zhang, H.; Zhang, P.; Sun, W. Intelligent pH-responsive ratiometric fluorescent nanofiber films for visual and real-time seafood freshness monitoring. Food Chem. 2025, 466, 142240. [Google Scholar] [CrossRef]
  36. Chen, L.-J.; Wang, J.-Y.; Zhao, X.; Yan, X.-P. Biogenic amine-responsive ratiometric fluorescent microneedle sensor for real-time visualization of meat freshness. Food Chem. 2025, 482, 144144. [Google Scholar] [CrossRef] [PubMed]
  37. Luo, Y.; Yang, P.; Bi, M.; Xu, L.; Du, F.; Ming, J. Monitoring Xylem Transport in the Stem of Lilium lancifolium Using Fluorescent Dye 5(6)-Carboxyfluorescein Diacetate. Phyton-Int. J. Exp. Bot. 2024, 93, 1057–1066. [Google Scholar] [CrossRef]
  38. Li, K.; Cai, J.; Zhang, Z.; Wu, S. Research Progress of Electrospun Natural Polymer Water Treatment Membranes. Polymer Bull. 2022, 35, 28–36. [Google Scholar]
  39. Li, K.; Cai, J.; Zhang, Z.; Tao, J.; Wu, J.; Zeng, S.; Wu, S. Application of electrospun bio-based nanofibrous membranes in water treatment. J. Funct. Mater. 2021, 52. [Google Scholar] [CrossRef]
  40. Zhang, J.; Huang, X.; Zhang, J.; Liu, L.; Shi, J.; Muhammad, A.; Zhai, X.; Zou, X.; Xiao, J.; Li, Z.; et al. Development of nanofiber indicator with high sensitivity for pork preservation and freshness monitoring. Food Chem. 2022, 381, 132224. [Google Scholar] [CrossRef]
  41. Zhang, J.; Zhang, J.; Guan, Y.; Huang, X.; Arslan, M.; Shi, J.; Li, Z.; Gong, Y.; Holmes, M.; Zou, X. High- sensitivity bilayer nanofiber film based on polyvinyl alcohol/sodium alginate/polyvinylidene fluoride for pork spoilage visual monitoring and preservation. Food Chem. 2022, 394, 133439. [Google Scholar] [CrossRef] [PubMed]
  42. Chen, M.; Yan, T.; Jiang, Q.; Li, J.; Ali, U.; Miao, Y.; Farooq, S.; Hu, Y.; Zhang, H. Real-time shrimp freshness detection by anthocyanin-enriched wheat gluten/gelatin electrospun nanofiber films. Food Chem. 2025, 469, 142542. [Google Scholar] [CrossRef]
  43. Zhai, X.; Xue, Y.; Song, W.; Sun, Y.; Shen, T.; Zhang, X.; Li, Y.; Ding, F.; Zhang, D.; Zhou, C.; et al. A ratiometric fluorescent electrospun film with high amine sensitivity and stability for visual monitoring of livestock meat freshness. Food Chem.-X 2024, 24, 101801. [Google Scholar] [CrossRef] [PubMed]
  44. Song, W.; Zhai, X.; Shi, J.; Zou, X.; Xue, Y.; Sun, Y.; Sun, W.; Zhang, J.; Huang, X.; Li, Z.; et al. A ratiometric fluorescence amine sensor based on carbon quantum dot-loaded electrospun polyvinylidene fluoride film for visual monitoring of food freshness. Food Chem. 2024, 434, 137423. [Google Scholar] [CrossRef] [PubMed]
  45. Povedailo, V.A.; Tikhomirov, S.A.; Yakovlev, D.L.; Lysenko, I.L.; Fan, F.; Shmanai, V.V. Fluorescence of the 5-and 6-Carboxyfluorescein Bifluorophores. J. Appl. Spectrosc. 2021, 88, 33–39. [Google Scholar] [CrossRef]
  46. Kravets, L.; Vinogradov, I.; Rossouw, A.; Gorberg, B.; Nechaev, A.; Apel, P. Functionalization of PET track-etched membranes with electrospun PVDF nanofibers for hybrid membranes fabrication in water desalination. Sep. Purif. Technol. 2025, 371, 133395. [Google Scholar] [CrossRef]
  47. Rashid, A.; Qayum, A.; Liang, Q.; Kang, L.; Raza, H.; Chi, Z.; Chi, R.; Ren, X.; Ma, H. Preparation and characterization of ultrasound-assisted essential oil-loaded nanoemulsions stimulated pullulan-based bioactive film for strawberry fruit preservation. Food Chem. 2023, 422, 136254. [Google Scholar] [CrossRef]
  48. Zhang, C.; Li, C.; Abdel-Samie, M.A.; Cui, H.; Lin, L. Unraveling the inhibitory mechanism of clove essential oil against Listeria monocytogenes biofilm and applying it to vegetable surfaces. LWT-Food Sci. Technol. 2020, 134, 110210. [Google Scholar] [CrossRef]
  49. Kang, L.; Liang, Q.; Chen, H.; Zhou, Q.; Chi, Z.; Rashid, A.; Ma, H.; Ren, X. Insights into ultrasonic treatment on the properties of pullulan/oat protein/nisin composite film:mechanical, structural and physicochemical properties. Food Chem. 2023, 402, 134237. [Google Scholar] [CrossRef]
  50. Cui, H.; Cheng, Q.; Li, C.; Khin, M.N.; Lin, L. Schiff base cross-linked dialdehyde β-cyclodextrin/gelatin-carrageenan active packaging film for the application of carvacrol on ready-to-eat foods. Food Hydrocoll. 2023, 141, 108744. [Google Scholar] [CrossRef]
  51. Han, Y.; Zhou, M.; Deng, J.; Cheng, C.; Xu, Z.; Hou, W.; Yi, Y.; McClements, D.J.; Chen, S. Intelligent carrageenan-based composite films containing color indicator-loaded nanoparticles for monitoring fish freshness. Food Packag. Shelf Life 2025, 47, 101420. [Google Scholar] [CrossRef]
  52. Zhai, X.; Wang, X.; Zhang, J.; Yang, Z.; Sun, Y.; Li, Z.; Huang, X.; Holmes, M.; Gong, Y.; Povey, M.; et al. Extruded low density polyethylene-curcumin film: A hydrophobic ammonia sensor for intelligent food packaging. Food Packag. Shelf Life 2020, 26, 100595. [Google Scholar] [CrossRef]
  53. Lu, Z.; Chen, S.; Chen, M.; Ma, H.; Wang, T.; Liu, T.; Yin, J.; Sun, M.; Wu, C.; Su, G.; et al. Trichromatic ratiometric fluorescent sensor based on machine learning and smartphone for visual and portable monitoring of tetracycline antibiotics. Chem. Eng. J. 2023, 454, 140492. [Google Scholar] [CrossRef]
  54. GB 5009.228-2016; National Food Safety Standard—Determination of Volatile Basic Nitrogen in Foods. Standards Press of China: Beijing, China, 2016.
  55. Zhang, X.; Chen, X.; Dai, J.; Cui, H.; Lin, L. A pH indicator film based on dragon fruit peel pectin/cassava starch and cyanidin/alizarin for monitoring the freshness of pork. Food Packag. Shelf Life 2023, 40, 101215. [Google Scholar] [CrossRef]
  56. Bei, Y.; Arkin, K.; Zheng, Y.; Ma, X.; Zhao, J.; Jin, H.; Shang, Q. Construction of a ratiometric fluorescent probe for visual detection of urea in human urine based on carbon dots prepared from Toona sinensis leaves and 5-carboxyfluorescein. Anal. Chim. Acta 2023, 1240, 340733. [Google Scholar] [CrossRef]
  57. Sasazawa, K.; Yamada, Y.; Sawada, H. Preparation and properties of fluoroalkyl end-capped oligomer/fluoresceins nanocomposites. J. Mater. Sci. 2008, 43, 1366–1375. [Google Scholar] [CrossRef]
  58. Wen, D.; Liu, Q.; Cui, Y.; Kong, J.; Yang, H.; Liu, Q. DNA based click polymerization for ultrasensitive IFN-γ fluorescent detection. Sens. Actuators B-Chem. 2018, 276, 279–287. [Google Scholar] [CrossRef]
  59. Dai, Q.; Jiang, L.; Luo, X. Electrochemical Oxidation of Rhodamine B: Optimization and Degradation Mechanism. Int. J. Electrochem. 2017, 12, 4265–4276. [Google Scholar] [CrossRef]
  60. Bao, Y.; Cui, H.; Tian, J.; Ding, Y.; Tian, Q.; Zhang, W.; Wang, M.; Zang, Z.; Sun, X.; Li, D.; et al. Novel pH sensitivity and colorimetry-enhanced anthocyanin indicator films by chondroitin sulfate co-pigmentation for shrimp freshness monitoring. Food Control 2022, 131, 108441. [Google Scholar] [CrossRef]
  61. Sali, R.; Naik, L.; Mohan, S. Optical and Microstructural Changes in 5(6)-Carboxyfluorescein Doped PVA. J. Polym. Compos. 2016, 4, 45–51. [Google Scholar]
  62. Ji, Y.; Liu, J.; Jiang, Y.; Liu, Y. Analysis of Raman and infrared spectra of poly(vinylidene fluoride) irradiated by KrF excimer laser. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 2008, 70, 297–300. [Google Scholar] [CrossRef]
  63. Won, K.; Jang, N.Y.; Jeon, J. A Natural Component-Based Oxygen Indicator with In-Pack Activation for Intelligent Food Packaging. J. Agric. Food Chem. 2016, 64, 9675–9679. [Google Scholar] [CrossRef] [PubMed]
  64. Mokrzycki, W.; Tatol, M. Colour difference∆ EA survey. Mach. Graph. Vis 2011, 20, 383–411. [Google Scholar]
  65. Han, Q.; Yang, M.; Zhang, Z.; Bai, X.; Liu, X.; Qin, Z.; Zhang, W.; Wang, P.; Zhu, L.; Shu, Z.; et al. Amine vapor-responsive ratiometric sensing tag based on HPTS/TPB-PVA fluorescent film for visual determination of fish freshness. Food Chem. X 2024, 21, 101152. [Google Scholar] [CrossRef]
  66. Ma, Y.; Li, Y.; Huang, T.; Yang, X.; Huang, J.; Huang, M. Preparation of an ammonia-responsive sensor based on bacterial cellulose film with enhanced AIE/ESIPT emission of fluorescent molecules bound to europium-based metal–organic framework. Chem. Eng. J. 2025, 513, 163034. [Google Scholar] [CrossRef]
  67. Zhao, X.; Wang, W.; Cheng, J.; Xia, Y.; Duan, C.; Zhong, R.; Zhao, X.; Li, X.; Ni, Y. Nanolignin-containing cellulose nanofibrils (LCNF)-enabled multifunctional ratiometric fluorescent bio-nanocomposite films for food freshness monitoring. Food Chem. 2024, 453, 139673. [Google Scholar] [CrossRef]
  68. Almeida, C.M.R.; Pina, J.; Magalhães, J.M.C.S.; Barroso, M.F.; Durães, L. One-pot synthesis of lanthanide-doped silica film as a ratiometric fluorescent probe for selective amine vapours detection. Opt. Mater. 2023, 145, 114396. [Google Scholar] [CrossRef]
  69. Huang, K.; Wang, L.; Deng, Y.; Zheng, H.; Wu, S.; Li, Z.; Lei, H.; Yu, Q.; Guo, Z. Development of amine-sensitive intelligent film with MIL-100(Fe) as function filler based on anthocyanins/pectin for monitoring chilled meat freshness. Int. J. Biol. Macromol. 2024, 270, 132463. [Google Scholar] [CrossRef]
  70. Teymouri, Z.; Shekarchizadeh, H.; Karami, K. Innovative real-time monitoring of fish freshness via agar-based film embedded with Cu-MOF colorimetric indicators. Chem. Eng. J. 2025, 510, 161751. [Google Scholar] [CrossRef]
  71. Zheng, M.; Ma, Q.; Li, L.; Wang, Y.; Suo, R.; Wang, W.; Sun, J.; Wang, J.; Liu, H. Gelatin-based smart film incorporated with nano cerium oxide for rapid detection of shrimp freshness. LWT 2023, 175, 114417. [Google Scholar] [CrossRef]
  72. Yang, Y.; Hu, L.; Yao, Y.; Zhong, K.; Yan, X.; Tang, L. A novel naphthol-malononitrile-based fluorescent dye capable of imaging amines in living cells and its polyvinyl alcohol film for real-time visual monitoring of fish freshness. J. Food Compos. Anal. 2025, 142, 107477. [Google Scholar] [CrossRef]
  73. Zhang, J.; Yu, J.; Yin, H.; Jia, Z.; Shi, C.; Yue, Y. An ammonia-sensitive fluorescence sensor based on polyvinyl alcohol-graphene quantum dots/halloysite nanotubes hybrid film for monitoring fish freshness. Food Chem. 2024, 454, 139734. [Google Scholar] [CrossRef] [PubMed]
  74. GB 2707-2016; National Food Safety Standard—Fresh and Frozen Livestock and Poultry Products. Standards Press of China: Beijing, China, 2016.
Figure 1. Fluorescence spectra of 5(6)-FAM (A) and RHB (B) at different excitation wavelengths.
Figure 1. Fluorescence spectra of 5(6)-FAM (A) and RHB (B) at different excitation wavelengths.
Foods 14 02200 g001
Figure 2. Fluorescence spectra (excitation wavelength of 490 nm) of the FAM@RHB probe solution at different volume ratios of FAM–RHB, before and after reacting with TMA (AE); the F1-F0 of different ratios of fluorescent probes (F): F1 is F516nm/F580nm after the reaction, and F0 is F516nm/F580nm before the reaction.
Figure 2. Fluorescence spectra (excitation wavelength of 490 nm) of the FAM@RHB probe solution at different volume ratios of FAM–RHB, before and after reacting with TMA (AE); the F1-F0 of different ratios of fluorescent probes (F): F1 is F516nm/F580nm after the reaction, and F0 is F516nm/F580nm before the reaction.
Foods 14 02200 g002
Figure 3. The UV–Vis absorption spectra of RHB and 5(6)-FAM.
Figure 3. The UV–Vis absorption spectra of RHB and 5(6)-FAM.
Foods 14 02200 g003
Figure 4. Fluorescence spectra of the FAM@RHB fluorescent probe (2:8) reacting with different concentrations of TMA under 490 nm excitation (A); linear relationship of the FAM@RHB ratiometric fluorescence intensity (F516nm/F580nm) versus TMA concentration (B); the color changes in the FAM@RHB fluorescent probe under daylight (C) and UV light (D) at different TMA concentrations.
Figure 4. Fluorescence spectra of the FAM@RHB fluorescent probe (2:8) reacting with different concentrations of TMA under 490 nm excitation (A); linear relationship of the FAM@RHB ratiometric fluorescence intensity (F516nm/F580nm) versus TMA concentration (B); the color changes in the FAM@RHB fluorescent probe under daylight (C) and UV light (D) at different TMA concentrations.
Foods 14 02200 g004
Figure 5. SEM images of FR-1, FR-2, FR-3, FR-4, and FR-5 films (A); fiber diameters of FR-1, FR-2, FR-3, FR-4, and FR-5 films (B).
Figure 5. SEM images of FR-1, FR-2, FR-3, FR-4, and FR-5 films (A); fiber diameters of FR-1, FR-2, FR-3, FR-4, and FR-5 films (B).
Foods 14 02200 g005aFoods 14 02200 g005b
Figure 6. The WCA images (A) and significance analysis (B) of the pure PVDF film, FR-1 film, FR-2 film, FR-3 film, FR-4 film, and FR-5 film. Different letters in the figure indicate statistically significant differences (p < 0.05).
Figure 6. The WCA images (A) and significance analysis (B) of the pure PVDF film, FR-1 film, FR-2 film, FR-3 film, FR-4 film, and FR-5 film. Different letters in the figure indicate statistically significant differences (p < 0.05).
Foods 14 02200 g006
Figure 7. Confocal fluorescence images of five different films.
Figure 7. Confocal fluorescence images of five different films.
Foods 14 02200 g007
Figure 8. FTIR spectra of the FR-2 film.
Figure 8. FTIR spectra of the FR-2 film.
Foods 14 02200 g008
Figure 9. The fluorescent color changes (A) and color difference value ΔE change (B) in the films stored at 4 °C for 14 days.
Figure 9. The fluorescent color changes (A) and color difference value ΔE change (B) in the films stored at 4 °C for 14 days.
Foods 14 02200 g009
Figure 10. The colors of the FR-1, FR-2, FR-3, FR-4, and FR-5 films in response to TMA at different concentrations (A); the plot of the ΔE values of the FR-1, FR-2, FR-3, FR-4, and FR-5 films versus the concentration of TMA (BF).
Figure 10. The colors of the FR-1, FR-2, FR-3, FR-4, and FR-5 films in response to TMA at different concentrations (A); the plot of the ΔE values of the FR-1, FR-2, FR-3, FR-4, and FR-5 films versus the concentration of TMA (BF).
Foods 14 02200 g010
Figure 11. The photos of pork and beef packaging containing a FR-2 film under 4 °C under visible light and UV light (A). The relation between ΔE values of the FR-2 film and TVB-N values of pork (B) and beef (C). Correlation analysis of ΔE values of the FR-2 film with TVB-N values of pork (D) and beef (E).
Figure 11. The photos of pork and beef packaging containing a FR-2 film under 4 °C under visible light and UV light (A). The relation between ΔE values of the FR-2 film and TVB-N values of pork (B) and beef (C). Correlation analysis of ΔE values of the FR-2 film with TVB-N values of pork (D) and beef (E).
Foods 14 02200 g011
Table 1. A comparison of previously reported works and this work.
Table 1. A comparison of previously reported works and this work.
No.ProbeVisible Light/FluorescenceAnalytesLODLinear RangeLiquids or Solid Sensors for UseFood TypeRef.
1βGlu-FITCFluorescenceAmmonia————PVA filmPork[14]
2HPTS/TPB FluorescenceAmmonia————PVA filmFish[65]
3BTCP-Ac@Eu-MOFFluorescenceAmmonia0.68 ppm——Bacterial cellulose membraneChicken meat[66]
4FITC- Eu(Phen)2FluorescenceAmmonia 1.83 ppm ——LCNF filmShrimp[67]
5Tb3+ and Eu3+ co-doped silicaFluorescenceAmine———— Filter paper Fish[68]
6ANs@MIL-2Visible lightAmmonia———— Pectin film Chicken breasts[69]
7Cu-MOFVisible lightAmmonia7.31 μM—— Agar film Fish[70]
8FITC/PpIXFluorescenceAmmonia5.0–2.5 × 104 ppm——CA filmShrimp[16]
9 CeNPs Visible lightHX35 μM6.2–200 μMGelatin film Shrimp [71]
10HYMFluorescencePutrescine4.23 μM1.259–5.428 μMPVA film Fish [72]
11 N-GQD Fluorescence Ammonia 0.63 ppm 20–500 ppmPVA film Fish [73]
125(6)-FAM/RHBFluorescenceTrimethylamine0.54 μM——Electrospun filmsBeef and
pork
This work
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Zhai, X.; Ma, X.; Sun, Y.; Xue, Y.; Ban, W.; Song, W.; Shen, T.; Li, Z.; Huang, X.; Sun, Q.; et al. A Hydrophobic Ratiometric Fluorescent Indicator Film Using Electrospinning for Visual Monitoring of Meat Freshness. Foods 2025, 14, 2200. https://doi.org/10.3390/foods14132200

AMA Style

Zhai X, Ma X, Sun Y, Xue Y, Ban W, Song W, Shen T, Li Z, Huang X, Sun Q, et al. A Hydrophobic Ratiometric Fluorescent Indicator Film Using Electrospinning for Visual Monitoring of Meat Freshness. Foods. 2025; 14(13):2200. https://doi.org/10.3390/foods14132200

Chicago/Turabian Style

Zhai, Xiaodong, Xingdan Ma, Yue Sun, Yuhong Xue, Wanwan Ban, Wenjun Song, Tingting Shen, Zhihua Li, Xiaowei Huang, Qing Sun, and et al. 2025. "A Hydrophobic Ratiometric Fluorescent Indicator Film Using Electrospinning for Visual Monitoring of Meat Freshness" Foods 14, no. 13: 2200. https://doi.org/10.3390/foods14132200

APA Style

Zhai, X., Ma, X., Sun, Y., Xue, Y., Ban, W., Song, W., Shen, T., Li, Z., Huang, X., Sun, Q., Wu, K., Chen, Z., Zou, W., Liu, B., Zhang, L., & Zhu, J. (2025). A Hydrophobic Ratiometric Fluorescent Indicator Film Using Electrospinning for Visual Monitoring of Meat Freshness. Foods, 14(13), 2200. https://doi.org/10.3390/foods14132200

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop