Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK
Abstract
1. Introduction
2. Materials and Methods
3. Results
4. Discussion
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Savini, G.; Hoffer, K.J. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vis. 2018, 5, 18. [Google Scholar] [CrossRef] [PubMed][Green Version]
- Wang, L.; Spektor, T.; de Souza, R.G.; Koch, D.D. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. J. Cataract. Refract. Surg. 2019, 45, 1416–1421. [Google Scholar] [CrossRef] [PubMed]
- Choi, J.Y.; Choi, A.; Kwon, H.; Jeon, S. Accuracy of IOL power calculation formulas for quadrifocal AcrySof IQ Panoptix TFNT implantation in patients with previous corneal refractive surgery: Comparison of SS-OCT-based biometers. J. Refract. Surg. 2021, 37, 836–841. [Google Scholar] [CrossRef] [PubMed]
- Yeo, T.K.; Heng, W.J.; Pek, D.; Wong, J.; Fam, H.B. Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery. Eye 2021, 35, 1705–1711. [Google Scholar] [CrossRef]
- Lawless, M.; Jiang, J.Y.; Hodge, C.; Sutton, G.; Roberts, T.V.; Barrett, G. Total keratometry in intraocular lens power calculation in eyes with previous laser refractive surgery. Clin. Exp. Ophthalmol. 2020, 48, 749–756. [Google Scholar] [CrossRef]
- Savini, G.; Hoffer, K.J.; Barboni, P.; Balducci, N.; Schiano-Lomoriello, D. Validation of the SToP formula for calculating intraocular lens power in eyes with previous myopic excimer laser surgery. J. Cataract. Refract. Surg. 2019, 45, 1562–1567. [Google Scholar] [CrossRef]
- Savini, G.; Hoffer, K.J.; Ribeiro, F.J.; Mendanha Dias, J.; Coutinho Catarina, P.; Barboni, P.; Schiano-Lomoriello, D. Intraocular lens power calculation with ray tracing based on AS-OCT and adjusted axial length after myopic excimer laser surgery. J. Cataract. Refract. Surg. 2022, 48, 947–953. [Google Scholar] [CrossRef]
- Savini, G.; Taroni, L.; Schiano-Lomoriello, D.; Hoffer, K.J. Repeatability of total keratometry and standard keratometry by the IOLMaster 700 and comparison to total corneal astigmatism by Scheimpflug imaging. Eye 2021, 35, 307–315. [Google Scholar] [CrossRef]
- Lupardi, E.; Taroni, L.; Hoffer, K.J.; Schiano-Lomoriello, D.; Savini, G. Comparison of corneal power calculation by standard keratometry and total keratometry in eyes with previous myopic FS-LASIK. J. Refract. Surg. 2021, 37, 848–852. [Google Scholar] [CrossRef]
- Haigis, W.; Lege, B.; Miller, N.; Schneider, B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefe Arch. Clin. Exp. Ophthalmol. 2000, 238, 765–773. [Google Scholar] [CrossRef]
- Aramberri, J. Intraocular lens power calculation after refractive surgery: Double-K method. J. Cataract. Refract. Surg. 2003, 29, 2063–2068. [Google Scholar] [CrossRef]
- Haigis, W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J. Cataract. Refract. Surg. 2008, 34, 1568–1663. [Google Scholar] [CrossRef] [PubMed]
- Wong, C.W.; Yuen, L.; Tseng, P.; Han, D.C. Outcomes of the Haigis-L formula for calculating intraocular lens power in Asian eyes after refractive surgery. J. Cataract. Refract. Surg. 2015, 41, 607–612. [Google Scholar] [CrossRef] [PubMed]
- Lanza, M.; Ruggiero, A.; Ha, J.; Simonelli, F.; Kane, J.X. Accuracy of formulas for intraocular lens power calculation after myopic refractive surgery. J. Refract. Surg. 2022, 38, 443–449. [Google Scholar] [CrossRef]
- Hoffer, K.J.; Savini, G. Effect of gender and race on ocular biometry. Intern. Ophthalmol. 2017, 57, 132–142. [Google Scholar] [CrossRef] [PubMed]
- Savini, G.; Hoffer, K.J.; Schiano-Lomoriello, D.; Barboni, P. Intraocular lens power calculation using a Placido disk-Scheimplug tomographer in eyes that had previous myopic corneal excimer laser surgery. J. Cataract. Refract. Surg. 2018, 44, 935–941. [Google Scholar] [CrossRef] [PubMed]
- Savini, G.; Hoffer, K.J.; Barrett, G.D. Results of the Barrett True-K formula for IOL power calculation based on Scheimpflug camera measurements in eyes with previous myopic excimer laser surgery. J. Cataract. Refract. Surg. 2020, 46, 1016–1019. [Google Scholar] [CrossRef]
- Whang, W.J.; Hoffer, K.J.; Kim, S.J.; Chung, S.H.; Savini, G. Comparison of intraocular lens power formulas according to axial length after myopic corneal laser refractive surgery. J. Cataract. Refract. Surg. 2021, 47, 297–303. [Google Scholar] [CrossRef]
- Wang, L.; Hill, W.E.; Koch, D.D. Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons post-keratorefractive intraocular lens power calculator. J. Cataract. Refract. Surg. 2010, 36, 1466–1473. [Google Scholar] [CrossRef]
- Wang, L.; Tang, M.; Huang, D.; Weikert, M.P.; Koch, D.D. Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology 2015, 122, 2443–2449. [Google Scholar] [CrossRef][Green Version]
- Liu, J.; Wang, L.; Chai, F.; Han, Y.; Qian, S.; Koch, D.D.; Weikert, M.P. Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia. J. Cataract. Refract. Surg. 2019, 45, 725–731. [Google Scholar] [CrossRef] [PubMed]
- Rong, X.; He, W.; Zhu, Q.; Qian, D.; Lu, Y.; Zhu, X. Intraocular lens power calculation in eyes with extreme myopia: Comparison of Barrett Universal II, Haigis, and Olsen formulas. J. Cataract. Refract. Surg. 2019, 45, 732–737. [Google Scholar] [CrossRef] [PubMed]
- Hamill, E.B.; Wang, L.; Chopra, H.K.; Hill, W.; Koch, D.D. Intraocular lens power calculations in eyes with previous hyperopic laser in situ keratomileusis or photorefractive keratectomy. J. Cataract. Refract. Surg. 2017, 43, 189–194. [Google Scholar] [CrossRef] [PubMed]
- Shammas, H.J.; Shammas, M.C.; Hill, W.E. Intraocular lens power calculation in eyes with previous hyperopic laser in situ keratomileusis. J. Cataract. Refract. Surg. 2013, 39, 739–744. [Google Scholar] [CrossRef]
- Hoffer, K.J.; Savini, G. Update on intraocular lens power calculation study protocols: The better way to design and report clinical trials. Ophthalmology 2021, 128, e115–e120. [Google Scholar] [CrossRef] [PubMed]
Mean ± SD | Range | |||
---|---|---|---|---|
Myopic Group | Hyperopic Group | Myopic Group | Hyperopic Group | |
Axial length (mm) | 26.49 ± 2.28 | 22.97 ± 0.77 | 21.98–33.54 | 21.66–24.52 |
Mean keratometry (D) | 40.17 ± 2.82 | 45.17 ± 1.36 | 35.96–49.55 | 42.20–47.25 |
Mean TK (D) | 39.85 ± 3.09 | 45.39 ± 1.51 | 35.42–50.21 | 42.08–47.72 |
Implanted IOL power (D) | 19.06 ± 3.19 | 22.32 ± 1.91 | 11.00–25.00 | 19.00–26.50 |
Manufacturer | Model | ULIB Constant | N° of Implanted IOLs | |
---|---|---|---|---|
Myopic Group | Hyperopic Group | |||
Alcon Laboratories, Inc. | AcrySof SN60WF | 119.0 | 20 | 15 |
Alcon Laboratories, Inc. | AcrySof Toric SN6Atx | 119.2 | 17 | 13 |
Alcon Laboratories, Inc. | Vivity DFT015 | 119.1 | 1 | 1 |
Alcon Laboratories, Inc. | Vivity Toric DF315 | 119.1 | 2 | 0 |
Alcon Laboratories, Inc. | Panoptix TFNT00 | 119.1 | 1 | 1 |
Alcon Laboratories, Inc. | Panoptix toric TFNT20 | 119.1 | 1 | 0 |
Alcon Laboratories, Inc. | Clareon CNA0T0 | 119.1 | 4 | 11 |
Alcon Laboratories, Inc. | AcrySof SN60AT | 118.8 | 0 | 1 |
J&J Vision | ZCB00/DCB00 | 119.3 | 2 | 0 |
J&J Vision | AAB00 | 119.3 | 1 | 0 |
Rayner Intraocular Vision | Rayone | 118.6 | 1 | 0 |
Soleko SPA | FIL611 | 119.1 | 1 | 0 |
Myopic Group | Hyperopic Group | |
---|---|---|
Mean PE | 0.093 ± 0.440 | −0.148 ± 0.462 |
MAE | 0.364 | 0.381 |
MedAE | 0.260 | 0.342 |
Eyes with PE ≤ ±0.25 D | 50.98% | 42.86% |
Eyes with PE ≤ ±0.50 D | 76.47% | 66.67% |
Eyes with PE ≤ ±0.75 D | 90.20% | 88.10% |
Eyes with PE ≤ ±1.00 D | 96.08% | 97.62% |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Galzignato, A.; Galvis, V.; Tello, A.; Urrea, J.F.; Hoffer, K.J.; Coutinho, C.P.; Schiano-Lomoriello, D.; Savini, G. Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK. Photonics 2023, 10, 624. https://doi.org/10.3390/photonics10060624
Galzignato A, Galvis V, Tello A, Urrea JF, Hoffer KJ, Coutinho CP, Schiano-Lomoriello D, Savini G. Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK. Photonics. 2023; 10(6):624. https://doi.org/10.3390/photonics10060624
Chicago/Turabian StyleGalzignato, Alice, Virgilio Galvis, Alejandro Tello, Juan F. Urrea, Kenneth J. Hoffer, Catarina P. Coutinho, Domenico Schiano-Lomoriello, and Giacomo Savini. 2023. "Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK" Photonics 10, no. 6: 624. https://doi.org/10.3390/photonics10060624
APA StyleGalzignato, A., Galvis, V., Tello, A., Urrea, J. F., Hoffer, K. J., Coutinho, C. P., Schiano-Lomoriello, D., & Savini, G. (2023). Accuracy of Haigis Formula Using Total Keratometry for IOL Power Calculation in Eyes with Previous Myopic and Hyperopic LASIK and PRK. Photonics, 10(6), 624. https://doi.org/10.3390/photonics10060624