Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645
1. Errors in Figure and Table
2. Text Correction
Reference
- Hu, J.; Li, Y.; Zhang, X.; Wang, Y.; Zhang, J.; Yan, J.; Li, J.; Zhang, Z.; Yin, H.; Wei, Q.; et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. [Google Scholar] [CrossRef] [PubMed]
Method | Material | Linear Range (LOD) | Reference |
---|---|---|---|
Differential pulse Voltammetry (DPV) | Au@Fe3O4 | 0.01 pg/mL~30 ng/mL (3 fg/mL) | Yang et al., 2016 [16] |
Photocurrent response | TiO2 nanotubes | 0.72 pM~3.6 nM (0.14 pM) | Mi et al., 2016 [17] |
Square wave voltammetry (SWV) | Prepared poly(thionine)-Au | 100 ng/mL~10 fg/mL (4.6 fg/mL) | Wang et al., 2017 [40] |
Cyclic voltammetry and differential pulse voltammetry | Multiwalled carbon nanotube (MWCNT) | 0.6~6.6 ng/mL (0.58 pg/mL) | Desai et al., 2018 [18] |
Linear sweep voltammetry (LSV) | AuNPs | 10~100 ng/mL (6.0 ng/mL) | Lopes et al., 2019 [15] |
Square wave voltammetry (SWV) | Graphene oxide-ferrocene nanofilm | 0.1~1000 ng/mL (0.03 ng/mL) | Erika et al., 2019 [41] |
Electrochemiluminescent (ECL) | Graphene composite (G/mRub) | 1.0 fg/mL~10 ng/mL (0.38 fg/mL) | Zhao et al., 2019 [19] |
Interdigitated electrode (IDE) | Polypyrrole/carbon nanotube | 0~300 ng/mL (28 ng/mL) | Ferreira et al., 2020 [20] |
Field effect transistor (FET) | Silicon nanowire | 1 ag/mL~1 ng/mL (0.2529 ag/mL) | This work |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Hu, J.; Li, Y.; Zhang, X.; Wang, Y.; Zhang, J.; Yan, J.; Li, J.; Zhang, Z.; Yin, H.; Wei, Q.; et al. Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. Biosensors 2024, 14, 461. https://doi.org/10.3390/bios14100461
Hu J, Li Y, Zhang X, Wang Y, Zhang J, Yan J, Li J, Zhang Z, Yin H, Wei Q, et al. Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. Biosensors. 2024; 14(10):461. https://doi.org/10.3390/bios14100461
Chicago/Turabian StyleHu, Jiawei, Yinglu Li, Xufang Zhang, Yanrong Wang, Jing Zhang, Jiang Yan, Junjie Li, Zhaohao Zhang, Huaxiang Yin, Qianhui Wei, and et al. 2024. "Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645" Biosensors 14, no. 10: 461. https://doi.org/10.3390/bios14100461
APA StyleHu, J., Li, Y., Zhang, X., Wang, Y., Zhang, J., Yan, J., Li, J., Zhang, Z., Yin, H., Wei, Q., Jiang, Q., Wei, S., & Zhang, Q. (2024). Correction: Hu et al. Ultrasensitive Silicon Nanowire Biosensor with Modulated Threshold Voltages and Ultra-Small Diameter for Early Kidney Failure Biomarker Cystatin C. Biosensors 2023, 13, 645. Biosensors, 14(10), 461. https://doi.org/10.3390/bios14100461