Review

Nanomaterials for Molecular Detection and Analysis of Extracellular Vesicles

by
Mitchell Lee Taylor
,
Anthony Gregory Giacalone
,
Kristopher Daniel Amrhein
,
Raymond Edward Wilson, Jr.
,
Yongmei Wang
and
Xiaohua Huang
*
Department of Chemistry, The University of Memphis, Memphis, TN 38152, USA
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Nanomaterials 2023, 13(3), 524; https://doi.org/10.3390/nano13030524
Submission received: 4 January 2023 / Revised: 23 January 2023 / Accepted: 24 January 2023 / Published: 28 January 2023
(This article belongs to the Section Biology and Medicines)

Abstract

:
Extracellular vesicles (EVs) have emerged as a novel resource of biomarkers for cancer and certain other diseases. Probing EVs in body fluids has become of major interest in the past decade in the development of a new-generation liquid biopsy for cancer diagnosis and monitoring. However, sensitive and specific molecular detection and analysis are challenging, due to the small size of EVs, low amount of antigens on individual EVs, and the complex biofluid matrix. Nanomaterials have been widely used in the technological development of protein and nucleic acid-based EV detection and analysis, owing to the unique structure and functional properties of materials at the nanometer scale. In this review, we summarize various nanomaterial-based analytical technologies for molecular EV detection and analysis. We discuss these technologies based on the major types of nanomaterials, including plasmonic, fluorescent, magnetic, organic, carbon-based, and certain other nanostructures. For each type of nanomaterial, functional properties are briefly described, followed by the applications of the nanomaterials for EV biomarker detection, profiling, and analysis in terms of detection mechanisms.

1. Introduction

Tissue biopsy is the gold standard method in the clinic for cancer diagnostics. It plays an important role in tailoring best treatment options for individual patients. However, tissue biopsy is invasive, costly, impractical for repeated testing, and unattainable for some cancer types. In addition, tumors are heterogeneous and evolve over time. Thus, biopsy data collected from limited tumor regions can be biased and can mislead clinical decisions. Additionally, the primary tumor is not accessible after surgery, inhibiting treatment monitoring. The limitations in tissue biopsy have driven the development of liquid biopsy, a means to detect and analyze cancer biomarkers in body fluids such as blood and urine.
Current liquid biopsy uses protein, nucleic acid, or tumor cells as the biofluid analytes [1]. Extracellular vesicles (EVs), including exosomes and microvesicles, have emerged as novel analytes for liquid biopsy for diagnostics, prognosis, and treatment monitoring of cancer and other diseases, due to their unique attributes [2,3,4,5]. EVs are membrane-bound vesicles that are continuously released into the extracellular environment by virtually all cells, with exosomes of endosomal origins and microvesicles from the plasma membrane [5,6,7]. They carry DNA, mRNA, and various proteins, such as tetraspanins, receptors, and adhesion molecules, which are reflective of their parental cells [5,8,9,10]. EVs from tumor cells can transfer oncogenic factors through intercellular communication and regulate angiogenesis, immunity, and metastasis, to promote tumorigenesis and progression [11,12,13,14,15,16,17]. Tumor-derived EVs enter the blood and many other body fluids, such as urine, saliva, and ascites, and cerebrospinal fluid [18,19,20,21,22]. Thus, EVs offer a robust new source of biomarkers for noninvasive liquid biology in medicine [23].
EVs are typically collected and isolated from body fluids using density- (differential centrifugation and precipitation), size-, and affinity-based methods, as well as microfluidics, which uses one or more of the aforementioned principles [24]. These methods eliminate the proteins and cell-debris or capture one specific molecular EV subtype for downstream analysis. They also concentrate EVs to facilitate subsequent analysis.
While size and morphology can be readily characterized using dynamic light scattering (DLS), nanoparticle tracking analysis (NTA), and electron microscopes, the molecular detection and analysis of EVs, however, are challenging, due to their small sizes and correspondingly low number of analytes per EV (down to a single digit for small exosomes). In the past decade, a variety of characterization methods have been used, including traditional protein and nucleic acid methods such as polymerase chain reaction (PCR), enzyme-linked immunosorbent assay (ELISA), Western blot, and flow cytometry, as well as emerging methods that involve advanced methodologies, materials, and/or devices [25]. Compared to traditional methods, these advanced methods improve EV’s molecular detection and analysis, in terms of sensitivity, simplicity, and efficiency, and thus are promising for use in clinical settings.
Among the emerging molecular characterization techniques, nanotechnology is playing an important role, due to the unique structure and functional properties of materials at the nanometer scale [26,27,28,29,30,31]. Nanomaterials exhibit exceptional functional properties that are often not available from discrete molecules and bulk materials. Nanostructures have a large surface-to-volume ratio that allows for highly efficient target interactions. The structure and functional properties can be used to develop new assays to overcome the limitations of the traditional ones. For molecular EV detection, a variety of nanomaterials have been used (Figure 1). For example, Lee and colleagues developed a nano-plasmonic exosome (nPLEX) assay based on surface plasmon resonance (SPR) sensing, with periodic nanohole to detect surface protein markers on exosomes and with a sensitivity 104 fold higher than Western blot and 102 fold higher than ELISA [32]. Hu and co-workers developed a different nanoplasmonic approach that can quantify tumor-derived exosomes in plasma with microliter-scale samples using the SPR light scattering properties of gold (Au) nanoparticles (NPs) in spherical and rod shape [33]. Huang’s group reported a surface-enhanced Raman scattering (SERS) method with gold nanorods (AuNRs) that achieved a limit of detection (LOD) of 2 × 106 exosomes per milliliter [34].
This review will summarize and discuss the nanotechnology-based methods and devices that have been developed within past decade for molecular EV detection and analysis, aiming at cancer research and applications. Differently from previous reviews, we categorize the methods based on the type of nanostructures used, including plasmonic, fluorescent, magnetic, organic, and carbon-based nanomaterials. For each type of nanomaterials, functional properties are briefly described, followed by the applications for EV’s biomarker detection, profiling, and analysis in terms of the detection mechanisms.

2. Plasmonic Nanostructures

When conduction electrons at the interface of two materials, where the real part of the dielectric function changes sign across the interface, are stimulated by incident light, a resonant oscillation of those electrons, known as SPR, occurs. The generated surface plasmon polariton, which is a non-radiative electromagnetic wave that propagates on the dielectric interface, is sensitive to small changes at this boundary, such as the absorption or disassociation of molecules or small biological entities such as proteins [35]. This characteristic has made SPR an attractive technology for researchers interested in molecular and biological sensing, including the detection of exosomes and microvesicles.
When the dimensions of the plasmonic materials decrease to the nanoscale, the SPR is confined to the surface of the nanomaterials. This localized SPR (LSPR), which is much stronger than SPR, can be obtained either with patterned nanostructures on a two-dimensional substrate or colloidal NPs of novel metals, such as Au and silver (Ag). In particular, for decades, colloidal AuNPs have been attractive nanomaterials across many fields, from materials science to biomedical applications, owing to their intriguing LSPR-enhanced optical properties [36,37,38,39,40,41]. This LSPR is size, shape, and structure sensitive, which leads to tunable optical properties, from the visible to the near infrared (NIR) region [42,43,44,45,46,47]. For example, when the shape of AuNPs is changed from a solid sphere to a rod, the LSPR is red shifted to the NIR region, a tissue penetrative window suitable for in vivo photothermal cancer therapy [48,49,50]. Due to the LSPR, AuNPs absorb and scatter light orders of magnitude stronger than non-metallic NPs and individual organic dyes [51]. Under dark field imaging, AuNPs appear as bright fluorescence analogs, due to their strong light scattering property [52,53,54]. Unlike fluorophores, AuNPs do not photo-bleach. Thus, AuNPs have been used as excellent contrast agents for bioimaging. The LSPR induces a strong electromagnetic field around the NPs, which can enhance the Raman scattering signals of adsorbed molecules [55]. SERS spectroscopy offers a fingerprint tool for detection and quantification of targeted molecules of interest [56]. The following sections discuss the different applications of plasmonic NPs for EV molecular detection and analysis based on the mechanisms of signal readout.

2.1. SPR Sensing

Traditional SPR sensing is commonly performed using Au-coated SPR sensor chips [57]. Typically, the chip is directly functionalized with detection antibodies, to recognize target-specific surface protein markers on EVs [58]. Alternatively, EVs are molecularly detected in a sandwich assay, where the vesicles are first captured on the sensor chips via EV markers such as tetraspanin CD9 and CD63 for exosomes, and the targeted surface markers are then detected by the detection antibodies [59]. The functionalization of the chip surface induces a slight background response of the sensor surface. When EVs are introduced into the sensor device, a large SPR spectra shift is generated, due to the binding of the anchored detection antibodies to the targeted surface marker on the cancer EVs [58]. Due to the variance in the expression level, the binding of different surface markers induces different degrees of SPR spectra shift, which allows for specific detection of different markers or exosomes from different origins [58]. The response is fast, usually within 5 min of sample introduction. The SPR methods can detect exosomes in lower than 106/mL concentrations, and their ability to analyze clinical samples for cancer diagnosis has also been demonstrated for cancer diagnosis [59]. The sensor response can also be detected by a charge-coupled device (CCD) camera, a method called SPR imaging (SPRi) [60]. Recently, Liu et al. reported a small and compact intensity-modulated SPR biosensor (25 cm × 10 cm × 25 cm) for exosomal protein detection in clinical settings [61]. This sensor consisted of a single prism, a small rotation stage, a continuous wave solid-state laser at 785 nm, and a splitter, while they used epidermal growth factor receptor (EGFR) and programmed death-ligand 1 (PD-L1) as biomarkers. Using this compact SPR sensor, the group were able to detect the exosomal EGFR derived from non-small cell lung cancer (NSCLC) at a concentration of 2 × 1010 exosomes/mL.
To enhance the sensitivity and throughput of SPR techniques, Lee, Weissleder, and colleagues developed a landmark nano-plasmonic exosome (nPLEX) sensor in 2014, by engineering a periodic nanohole array device [32]. This sophisticated sensor used the transmission SPR spectrum of periodic nanohole arrays and offered improved sensitivity due to the electromagnetic enhancement at the nanoholes. The chip consisted of a lattice of 44 × 32 nanoholes on a 200 nm thick Au film on a glass substrate, where each hole was 200 nm in diameter at a hole-to-hole periodicity of 450 nm. Detection antibodies were attached to the chip via a polyethene glycol (PEG) (molecular weight: 2000) linker. Exosomes were injected into the flow cell and the associated spectral shift was measured to sense target-specific proteins on the exosomes. This nPLEX sensor produced sensitivities of 103 exosomes, which was 104 times higher than Western blot and 102 times higher than ELISA. The captured exosomes were additionally labeled with spherical AuNPs, improving the signal by 20 percent. Star shaped NPs were also used for secondary labeling, producing an enhancement of 300 percent over non-labeled exosomes. This high throughput analysis was achieved by integrating the nPLEX chip with a multi-channel microfluidic cell, where each channel could span three sensing units. The devices can measure transmission SPR intensities of 12 × 3 nanohole arrays simultaneously using the imaging setup. Using nPLEX and ascites samples from ovarian cancer patients, the authors identified exosomal CD24 and EpCAM as biomarkers for ovarian cancer diagnostics.
Four years later, the same researchers developed this nanohole-based SPR assay into a platform that can analyze both intravesicular and transmembrane proteins (Figure 2) [62]. This intravesicular nanoplasmonic system (iNPs) involves vesicle lysis, to release intravesicular proteins, binding of the proteins to antibody-functionalized iNPs chip, and further labeling of the captured proteins by AuNPs, to enhance the SPR shift. The AuNPs had 9-fold higher responses compared to EV binding without AuNPs. The iNPs only required 0.5 µL sample to analyze each marker and allowed for simultaneous analysis of 100 markers (10 × 10 array). Using iNPs, they were able to monitor drug responses and found unique drug-dependent EV protein signatures.
Other ways to enhance SPR sensitivity with nanotechnology have also been reported [63,64,65,66]. For example, Thakur made a self-assembly gold nano-islands (SAM-AuNIs) chip as an SPR sensor, by annealing an Au-coated glass slide [63]. This sensor achieved a LOD of 0.194 μg/mL and linear dynamic range of 0.194–100 µg/mL. It successfully detected and distinguished exosomes from microvesicles from cells, serum, and urine in a mouse model. Rather than making nanostructures on Au film, Wang et al. demonstrated an assay to enhance the traditional SPR sensor using a dual AuNP-assisted signal amplification approach, in which aptamer/T30 linked AuNPs were bound to the targeted surface proteins on the captured exosomes on the SPR chip, and then A30-coated AuNPs were applied to bind to the aptamer/T30 linked AuNPs [64]. This assay achieved a LOD of 5 × 103 exosomes/mL, which was 104-fold more sensitive than ELISA. An AuNP-enhancement mechanism was also achieved for the SPRi sensors [66]. Recently, multiplexed detection with an AuNP-enhanced SPRi assay was reported by Fan et al., by engineering a microarray SPRi chip [67]. This assay achieved a LOD of 107 exosome/mL.

2.2. LSPR Light Scattering Detection

The use of AuNPs to detect exosome surface protein markers based on LSPR scattering properties was first demonstrated by Liang et al. in 2017 [33]. This nanoplasmon-enhanced scattering (nPES) assay used antibody-conjugated spherical AuNPs to target one marker, such as CD63, and antibody-conjugated AuNRs to target another marker, such as CD9. As the spherical AuNPs scatter light in the visible region and AuNRs scatter in the NIR region, they are detected as green and red particles, respectively, under dark field imaging. Thus, the two targeted surface markers on exosomes could be simultaneously detected. Moreover, when the spherical and rod-shaped AuNPs were close to each other, their LSPR exerted coupling, leading to a yellow color with increased scattering intensity. The appearance of yellow particles suggested the co-expression of the two surface markers on the same exosome. The sensitivity was very high because AuNPs can be detected at single particle level under dark field imaging. Combing a purification-free exosome capture strategy with CD81 antibodies and a multi-well glass slide as the sample sensor, this nPES assay is easy-to-use and consumes low sample volumes (1 µL of plasma). Using an nPES assay, they identified ephrin type-A receptor 2 (EphA2) as an EV marker for diagnosis of pancreatic cancer. They also demonstrated that EphA2-posive EVs can be used to monitor tumor progression and treatment response, with better performance than the conventional ELISA.
Recently, we developed a facile method to detect surface proteins on individual exosomes, using AuNPs coupled with a dual imaging approach (Figure 3) [68]. In this method, small exosome-like EVs were captured onto a multi-well Au chamber slide via CD81 antibodies and labeled with cholesterol-PEG-Cy5 (Chol-PEG-Cy5, molecular weight 2000) and localized by fluorescence imaging with an angled laser excitation. Targeted specific surface proteins on EVs were labeled with antibody-conjugated 60 nm AuNPs and detected using dark field imaging. Dual mask (EV) and target (surface protein) images were achieved with a dual fluorescence and dark field imaging system at single EV and single particle level. Superimposing the mask and target images identified AuNP-bound EVs and AuNP-free EVs. Image analysis with a python-code-based single vesicle dual imaging analysis (SEDIA) method gives the EV population density profile, which shows the AuNP-bound and AuNP-free EVs. Calibration with AuNPs linked with IgG control, the dual imaging single vesicle technology (DISVT), determines the fraction of marker-targeted EVs of all captured EVs. Using DISVT, we demonstrated that DISVT, but not ELISA, detected human epidermal growth factor receptor 2 (HER2)-positive breast cancer by quantification of HER2-positive EVs among the CD81-positive plasmon EVs. This DISVT needs less than 10 µL of 20–1000 times diluted plasma per assay. The SEDIA can analyze multiple pre-processed images simultaneously and within seconds. Due to its advantages in terms of simplicity, sensitivity, and sample consumption, this facile and ultrasensitive DISVT holds great promises for clinical cancer diagnostics and real-time monitoring.

2.3. SERS Detection

Molecular detection of EVs via SERS has been reported using two different approaches: label-free and labeled assays with SERS nanotags. In the label-free detection, EVs are deposited onto SERS substrates, often a rough metal surface or Au or Ag nanopatterns on two-dimensional substrates. Molecular Raman signals from EVs such as protein, nucleic acid, and lipid are enhanced by the plasmonic substrates and detected by Raman spectroscopy [69,70,71,72,73,74]. For example, Tirinato et al. fabricated Ag nanograins on a silicon micropillar to enhance the Raman signals from exosomes deposited onto the SERS substrates [69]. They found a difference in the SERS signals from heathy and tumor cell exosomes. While exosomes from healthy cells exhibited higher intensities of peaks corresponding to lipid vibrations, exosomes from colon cancer cells showed higher signals from RNA.
In another study by Park et al., spherical AuNPs were deposited onto a cover glass through a drying process (Figure 4A) [71]. Purified exosomes from lung cancer cell lines and alveolar epithelial cells were deposited onto the AuNP-decorated cover glass and SERS signals from the exosomes were measured. The SERS signals from two different lung cancer cell lines, H522 and H1299, were different from each other and from the alveolar epithelial cells and the phosphate buffered solution (PBS) control. Principle component analysis (PCA) showed clear clusters of the four groups, indicating the ability to classify exosomes by SERS detection.
Label-free SERS detection on individual exosomes was achieved by Stremersch et al. in 2016 (Figure 4B) [75]. In this study, exosome-like vesicles were coated with 10 nm AuNPs utilizing electrostatic adsorption. These densely packed AuNPs enhanced the SERS signals from vesicles, which allowed for detection of individual vesicles with a Raman microscope. Using partial least squares discriminant analysis on the obtained spectra, they were able to differentiate vesicles of different origins, such as melanoma EVs and red blood cell EVs.
Targeted surface markers on exosomes need to be detected with SERS-active nanotags via Raman reporters [76,77]. In 2018, we demonstrated a simple, inexpensive, and portable Raman exosome assay for detecting surface protein markers on exosomes using SERS AuNRs (Figure 4C) [34]. In that study, a miniaturized Au array device was fabricated for multiple analysis by assembling a 3-D printed multi-well template and gold-coated microscopy glass slide. Exosomes purified through ultracentrifugation were captured on the device using antibodies targeting surface markers of interest. To detect the captured exosomes, AuNRs were adsorbed with a QYS21 Raman tag to form SERS nanotags. The nanotags were then adsorbed onto the exosomes through electrostatic interactions between the positively charged cetyltrimethylammonium bromide (CTAB) on the surface of AuNRs and the negatively charged lipid membrane of exosomes. Using a portable Raman spectrometer, we could quantitatively detect the exosomes on the Au device and thus detect different surface protein markers using different capture antibodies. By analyzing plasma samples from healthy donors and breast cancer patients, we identified epidermal growth factor receptor 2 (HER2) and epithelial cellular adhesion molecule (EpCAM) as exosomal biomarkers for detecting HER2-positive breast cancer.

2.4. Colorimetric Detection

A common point of care (POC) detection system is the lateral flow assay (LFA). The principle of LFA is based on the transportation of liquid samples via capillary force on a two-dimensional polymeric strip that molecularly interacts with the analytes in the liquid samples. The presence of the analytes is detected colorimetrically based on the absorbance properties of the detection labels and using the naked eye [78]. LFA is rapid, simple, and cost-effective, as well as suitable for the screening of many diseases [79]. A common strategy of LFA is the use of antibodies as the detection agents, which is called a lateral flow immunoassay (LFIA). In this method, the detection label, often AuNPs, is lined with antibodies to recognize the antigens to be detected [80]. As the light absorption of AuNPs is in the visible region around 520 nm, they are visible to the eye, thus making the assay widely accessible to the general public.
The use of LFIA to detect exosomes was reported by Oliveira-Rodrı’guez et al., in 2016 [81]. In this study, anti-CD9 and anti-CD63 monoclonal antibodies were conjugated to 40 nm AuNPs to detect exosomes. Exosomes, if present in the liquid sample, were sandwiched between the AuNP conjugates and anti-CD81 immobilized in the nitrocellulose membrane of the strip, which gave a test line. The unbound AuNP conjugates migrated further, to give a control line. This method, which requires purified exosomes, can be completed within 15 min, with a LOD of 8.5 × 108/mL. It has been tested for the reliable detection of exosomes in cell culture supernatants, human plasma, and urine. A year later, the same researchers achieved a multiple target assay, by incorporating multiple capture lines [82]. They also compared three different nanomaterials, AuNPs, magnetic nanoparticles (MNPs), and carbon black, for colorimetric readouts and found that the AuNPs gave the best results.
Another facile colorimetric detection platform using AuNPs is to use the color change through aggregation, as demonstrated by Jiang et al. [83]. The AuNPs were functionalized with a panel of aptamers. In the presence of exosomes, the specific binding of aptamers to the targeted surface proteins on exosomes displaced aptamers from AuNPs, inducing aggregation of AuNPs. This caused a color change from red to blue, due to the red shift of the LSPR of AuNPs from individual particles to aggregates.
A further colorimetric method is to use the enzymatic activity of AuNPs to generate colorimetric detection with 3,3′,5,5′- tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2), as reported by Di et al. [84]. In this approach, AuNPs were formed on the surface of exosomes by the reduction of Au (III) chloride trihydrate (HAuCl4) with sodium borate hydride (NaBH4). In the presence of TMB and H2O2, AuNPs on the surface of exosomes catalyzed the oxidation of TMB by H2O2, inducing a color change of the solution for detection either by eye or with a absorption spectrometer. This method readily detected multiple proteins with an ELISA plate reader and differentiated hepatic cell carcinoma (HCC) patients from hepatitis B patients and healthy donors, suggesting a strong diagnostic potential.

2.5. Electrochemical Detection

An electrochemical biosensor is a device that detects biomarkers by converting molecular interactions into electronic readout signals [85,86]. They have been widely used for EV detection [87,88,89,90,91,92,93]. Nanomaterials have been used in electrochemical detection systems to improve the signal readout [94,95,96]. For example, Hu et al. used AgNPs to enhance differential pulse voltammetry (DPV) signals for detection of renal binding proteins [97]. AuNPs have been widely used to enhance the electrochemical detection of DNA [98].
In 2016, Zhou et al. reported electrochemical detection of captured exosomes/microsomes with copper (Cu) NPs and AgNPs [99]. In their study, exosomes or microsomes were captured onto an aptamer-modified microfabricated chip containing 11 individual circular Au electrodes. Antibody-conjugated AgNPs were used to report EpCAM, and antibody-conjugated CuNPs were used to report prostate-specific membrane antigen (PSMA), a biomarker for prostate cancer. Electro-oxidation of these metal NPs induced an electronic response for signal readout. This sensor reached a LOD of 50 exosomes/sensor. Using this sensor, the authors reported that prostate cancer patients showed significantly higher levels of EpCAM and PSMA-positive exosomes, suggesting a good potential for diagnosis of prostate cancer.

2.6. Other Detection Methods

Other detection methods involving plasmonic nanomaterials have also been reported [100,101,102,103,104,105,106,107,108,109,110]. One of these methods is to use cantilever arrays to respond to the molecular binding of multiple targets [100]. AuNPs coated with antibodies were used to detect exosomes captured on a microcantilever. With a reference cantilever, this method detected CD24, CD63, and EGFR on exosomes simultaneously, with a LOD of ~0.1 pg/mL.
Another method is to use AuNPs to amplify a surface acoustic wave (SAW) for the detection and quantification of exosomes, as reported by Wang et al. [106]. Exosomes were captured onto a SAW chip that was functionalized with anti-CD63 antibodies. Streptavidin-conjugated AuNPs recognized exosomes via biotin-conjugated EpCAM that was bound to the exosomes in advance. This sensor reached a high sensitivity, with a LOD of 1.1 × 103 exosomes/mL. The AuNPs enhanced the signals of the SAW chip by two orders of magnitude.
A further exciting application of AuNPs for the in vivo imaging and tracking of exosomes was demonstrated by Betzer et al. in 2017 [101]. In their studies, exosomes derived from mesenchymal stem cells (MSCs) were labeled with AuNPs via active uptake of glucose-modified AuNPs. The AuNP-labeled MSC exosomes were administrated in vivo in a mouse model via intranasal (IN) or intravenous (IV) administration. Quantification of the Au amount with inductively coupled plasma (ICP) spectrometry at 24 h post-injection showed the accumulation of exosomes in a substantial amount in the brain. In an animal model of stroke, CT imaging clearly identified and tracked in real time the exosome migration and accumulation in the stroke-effected area of the mouse brain. They were detected as early as 1 h post-IN injection. This exosome labeling and in vivo imaging technique can serve as a powerful tool for the diagnosis of various brain disorders.
In addition, AuNPs can be used to work with fluorophores to detect EVs, by making use of the energy transfer process between plasmonic NPs and fluorophores [102,103]. This energy transfer leads to a quenching effect on the emission of fluorophores when the fluorophores are in proximity with AuNPs. The emission of the fluorophore is resumed when the fluorophore leaves the metal NPs. AuNPs themselves also exhibit fluorescence and thus can serve as fluorescent labels for EV detection [105]. Moreover, AuNPs can also be used as a pure scaffold to carry reporter molecules or targeting ligands for EV detection via other detection mechanisms [104].

3. Fluorescence Nanomaterials

3.1. Quantum Dots (QDs)

Quantum dots (QDs) can be used in many ways to detect EVs. One of their greatest advantages is that they are very small, being approximately 2–10 nm in diameter. This gives them the ability to be used as an efficient labeling and detection tool for small exosomes. Another advantage to using QDs is that they have strong and narrow fluorescence properties with a broad absorption spectrum. This allows for bright multicolor fluorescence imaging with a single laser excitation. In addition, they exhibit excellent photostability [111]. Furthermore, QDs functionalized with a variety of ligands are readily available from commercial resources [112].
Thus, QDs are often used as excellent fluorescent labels to detect exosomes through fluorescence imaging and spectroscopy [113,114,115,116,117,118,119,120]. One remarkable study was performed by Bai et al., who demonstrated multiplexed detection of tumor exosomes via queued beads combined with QDs in a microarray (Figure 5A) [115]. Exosomes were isolated and bound to magnetic microbeads, which were then trapped among micropillars in a microfluidic chip. Target-specific QDs were bound to exosomes on the microbead and detected by fluorescence imaging. Due to the separation of microbeads by the micropillars, fluorescence signals from QDs were dispersed into every single bead, thus avoiding optical interferences, for more accurate test results. By using QDs of different sizes and thus different colors (red, green, and yellow) with different cancer markers, they could detect exosomes derived from different cancer cell lines. Using this technique, they found that the cancer markers on exosomes derived from lung cancer cells were about six-fold higher than those from normal cell lines. Additionally, they were able to detect lung cancer with good diagnostic power using clinical plasma samples.
A different study using QDs imaged exosomes on live cells and tissue sheets (Figure 5B) [117]. In this study by Zhang et al., QDs were attached to exosomes via click chemistry. Using this labeling technique and fluorescence imaging, they were able to visualize semen EVs from human vaginal mucosa. They were also able to visualize brain EVs in real time and observe the interactions of brain EVs with microglial BV-2 cells. This method enabled the study of EV localization and function in cells and tissue sections with bright and photostable QDs.
In our recent study, we demonstrated a simple way to detect exosome surface protein markers and to diagnose cancer, using QDs combined with magnetic separation (Figure 5C) [119]. We used magnetic beads linked with CD81 antibodies to isolate exosomes from a conditioned cell culture medium and plasma samples from human subjects. QD655 was used to indirectly target the surface caner markers of interest with secondary antibodies via streptavidin and biotin chemistry. A routine fluorimeter was used to collect the fluorescence spectrum from the exosome solutions labeled with QD655 or the control without primary antibodies. This method exhibited a good sensitivity, with a LOD of 4.7 × 107 exosomes/mL. It was well correlated with ELISA, with a high Pearson correlation coefficient of 0.986. Using this method, we quantitatively determined the expression level of EpCAM, HER2, CD44, and CD24 on three breast cancer cell lines, MDA-MB-231, SKBR3, and MCF7, which were different from each other and different from that of the healthy breast cell line MCF12A. In a proof-of-concept study, with pilot clinical samples from HER2-positive breast cancer patients and healthy donors (n = 8 for each group), we showed that HER2-positive exosomes in plasma were a strong diagnostic marker for diagnosis of HER2-poisitve breast cancer, with an area under curve (AUC) around 0.97. The advantage of this method over other detection techniques is its simplicity, which only involves magnetic isolation, mixing with primary antibodies, secondary antibody-conjugated QD655, and the detection of the exosome suspension with a common fluorometer.
A different application of QDs for exosome detection was reported by Boriachek et al. in 2017 based on electrochemical detection [121]. CdSe QDs were functionalized with anti-HER2 and anti-FAM134B antibodies to target breast and colon cancer exosomes, respectively. The QDs were dissolved in acid conditions and the Cd2+ were quantified by anodic stripping voltammetry at a bare glassy carbon working electrode. This method was very sensitive, with a LOD of 105 exosomes/mL. QDs have also been used to enhance electrochemiluminescence signals (ECL) by self-assembly to Ru(dcbpy)32+, to reduce energy loss and shorten the electron transfer distance [122]. MoS2 QDs were used to fabricate a self-powered photoelectrochemical biosensor for exosomal RNA detection, by combining with TiO2 nanosilks [123].

3.2. Carbon-Based Nanoparticles

Other fluorescence NPs have also been used to detect EVs [124,125,126,127,128]. Particularly, upconversion nanoparticles (UCNPs) are attractive for EV detection, due to their strong fluorescence properties. An example is the aptasensor reported by Chen et al. in 2018 [125]. In this sensing platform, the UCNPs worked with plasmonic AuNRs for exosome detection through luminescence resonance energy transfer (LRET) from UCNPs to AuNPs. This was done by linking the two nanoplatforms using aptamers via specific binding to the targeted molecules on the surface of exosomes. The presence of exosomes quenched the fluorescence of UCNPs, which enabled the quantitative detection of exosomes. This LRET-based mechanism achieved a LOD of 1.1 × 106 exosomes/mL. The same group later replaced AuNPs with a rhodamine dye and achieved a much higher detection sensitivity, with a LOD of 8 × 104 exosomes/mL [127].
A remarkable recent study by Huang et al. extended UCNPs to detect single EVs [129]. The authors found that while the Er3+-doped UCNPs had a better brightness, the Tm3+-doped UCNPs had a better resolution beyond the diffraction limit. Using a super-resolution microscope, they could distinguish adjacent UCNPs on single small EVs. They also found that the number of bound UCNPs ranged from 3 to 21 when using super-resolution fluorescence imaging. This method opens an exciting opportunity to measure the number of surface antigens on single EVs using fluorescence NPs.

4. Magnetic Nanostructures

Magnetic nanostructures such as MNPs and magnetic nanowires are often used to isolate and purify EVs from cell culture supernatant and body fluids [130,131,132,133,134,135,136,137,138,139,140,141,142,143]. However, they can also be used as signal readout agents to the detect molecular constitutes of EVs. A major approach was developed by Lee, Weissleder, and co-authors, who also developed the nanoplasmonic sensors described above [144]. They designed a microfluidic chip that can isolate and concentrate MNP-bound EVs and also provide in-line detection, via a micro-nuclear magnetic resonance (µNMR) device that they developed previously for cancer cell detection [145,146,147]. The principle of µNMR is based on the measurement of the transverse decay rate (R2), which is proportional to the MNP concentration. This allows quantification of the targets of interest via MNP-labeling. To detect microvesicles with µNMR, they labeled the vesicles with target-specific MNPs via a two-step biorthogonal approach. To calibrate the vesicle total counts, they used CD63 as an internal reference marker. The signal linearly corresponded with the amount of microvesicles. The µNMR method was highly sensitive, being 104, 103, and 102-fold more sensitive than Western blotting, ELISA, and NTA, respectively. Using µNMR with MNPs as the detection agents, they confirmed that the protein profile of microvesicles from glioblastoma multiforme (GBM) indeed reflects that of their parental cells. Using the µNMR system, the authors found that circulating GBM microvesicles can serve as a surrogate for tumor mutations and monitor treatment-induced changes.
Lee, Weissleder, and co-authors later developed another μNMR system integrated with online isolation (Figure 6) [148]. The μNMR system had a membrane filter and capillary guide sandwiched between two ring magnets, to isolate microvesicles from blood. After isolation, the microvesicles were collected in a reservoir and labeled with MNPs, which were then detected by measuring the transverse relaxation rate. The whole process was performed entirely on the chip, eliminating the need for external vesicle operations. Using this μNMR system, the authors found that the counts of microvesicles increased with the aging of blood, but the levels of protein expression, such as for CD235a, CD44, CD47, and CD55, were the same. They also found that microvesicles had the ability to induce oxidative stress and consumed nitric oxide. This suggests that this system can be used to interrogate and monitor blood quality and blood transfusion safety.
Similarly to other nanomaterials, MNPs can also be used as a nanocarrier of bioactive molecules for exosome detection. For example, Chen et al. functionalized Fe3O4 NPs with EpCAM-specific aptamers [149]. In the presence of exosomes, the aptamers on the Fe3O4 NPs bound to the exosomes and thus were displaced from the NPs. The aptamer-bound Fe3O4 NPs had a higher peroxidase activity than untreated ones. Thus, the presence of exosomes decreased the catalytic activity of Fe3O4 NPs, which led to a lower degree of oxidation of TMB by H2O2 than the control without exosomes or with exosomes bearing a low level of EpCAM. This colorimetric change can be used to quantitatively measure the level of targeted exosomes. MNPs can also be used for direct colorimetric detection of EVs via LFIA using the brown color of the NPs [150].

5. Organic Frameworks

5.1. Metal Organic Frameworks (MOFs)

Metal-organic Frameworks (MOFs) are a category of 2-D and 3-D synthesized organic and crystalline nanomaterials formed from the self-assembly of organic linkers and metal ions [151,152,153]. MOFs are highly tunable, porous, rigid, and stable materials. In some cases, MOFs can expand and contract based on their environment and the material loaded within the pores [151,152,153]. MOFs are used in various applications, such as solar panels, carbon capture, drug delivery, and cancer detection [154].
A novel application of MOFs is to build an electrochemical biosensor for exosome detection, as demonstrated by Sun et al. in 2020, by making use of the high porosity property of MOFs (Figure 7) [155]. In this technique, highly porose UiO-66-NH2, a typical Zr-MOF, was synthesized and loaded with electroactive redox indicator methylene blue (MB), which is often used for electrochemical detection [156]. A specially-designed peptide was assembled on the electrode surface to recognize EGFR and EGFR variant (v) III mutation (EGFRvIII), the GBM protein biomarkers, so as to capture GBM exosomes. Then, the MB@Zr-MOFs bound to the captured exosomes, producing a highly amplified electrochemical signal via the interaction between the Zr4+ from the MOFs and phosphate head of the lipid membrane from the exosomes. This electrochemical signal, recorded by the square wave voltammograms (SWV) was linearly proportional to the concentration of the bound exosomes. This sensor exhibited a LOD of 7.83 × 106 exosomes/mL. Using this sensor, the authors distinguished GBM patients from healthy groups by detecting and quantifying EGFR/EGFRvIII positive exosomes from serum samples.
A portable paper-based electrochemical biosensor using Zr-MOFs was later reported by Liu et al. [157]. This sensor was developed by combing a Zr-MOF functionalized paper and a screen-printed electrode (SPE). Zr-MOFs were coated on the surface of the paper sensor to capture exosomes via the Zr-P-O interactions. Then, an aptamer was added to recognize CD63. The aptamer also triggered hybridization chain reaction (HCR) amplification, which then catalyzed the oxidation of TMB and thus reduced the signal response of TMB on SPE. Due to the HCR, this sensor is highly sensitive, with a LOD of 5 × 103 exosomes/mL. A different DNA amplification strategy involving MOF was reported by Cao et al. [158]. They made a pH-sensitive (via polyvinylpyrrolidone (PVP)) and horseradish peroxidase (HRP)-encapsulating zeolitic imidazolate framework-8 (ZIF-8). Hyperbranched rolling circle amplification (HRCA) was introduced on the capture probe of exosomes to release protons and thus lower the pH of the local environment where the PVP@HRP@ZIF-8 was located. At low pH, the MOF complex released HRP, to amplify electrochemical signals. This sensor reached a superior sensitivity, with a LOD of 334 exosomes/mL.
By varying the strategies in the signal readout and the MOF function, different electrochemical sensors can be developed for EV detection, in terms of both protein and RNA markers [159,160]. By combining other detection approaches, MOFs can be used to capture and purify exosomes with or without MNPs [141,161,162,163]. For example, an MOF made of Tim4@ILI-01 immunoaffinity flake, has the ability to capture and separate exosomes in samples from healthy patients and those diagnosed with lung adenocarcinoma [161]. The Fe3O4@UiO-66-NH2@PA-Ti4+ exhibited an exosome capture and recovery rate of 97.3% within 5 min of exosomes [141].

5.2. Carbon Organic Frameworks (COFs)

Covalent organic frameworks (COFs) have started to garner interest for EV detection and capture in recent years, due to their high porosity. COFs are 2-D and 3-D crystalline structures exhibiting strong covalent bonds producing a tunable, porous, and extremely stable material. Unlike MOFs, COFs do not contain metal but are constructed through covalently bonded organic materials [164]. A recent work by Wang et al. demonstrated the use of COFs for the detection of colorectal cancer exosomes [165]. In this work, a COF-based nanoprobe was fabricated by complexing para-sulfocalix arene hydrate (pSC4), AuNPs and HRP. This HRP-pSC4-AuNPs@COFs was bound with amino acids on the exosome surface via pSC4. The high porosity of COFs ensured the high loading amount of HRP. The AuNPs boost the migration of charge carriers and the response of biosensors for exosome detection. Due to these unique features, this nanoprobe exhibited a high LOD of 1.6 × 105 exosomes/mL. It successfully differentiated exosomes between colorectal cancer patients and heathy controls.

6. Carbon Nanomaterials

6.1. Carbon Nanotubes (CNTs)

Carbon nanotubes (CNTs) are nanoscale tubes made of carbon bonds [166]. The two categories of carbon nanotubes are single-wall carbon nanotubes (SWCNTs) and multi-wall carbon nanotubes (MWCNTs) [166,167]. CNTs have been used for many applications, from catalyst supports, to biochemical sensors and drug delivery carriers [168,169,170,171]. By making CNT arrays, exosomes can be isolated and purified for downstream applications [172].
An interesting application for EV detection was demonstrated by Xia et al., who developed a colorimetric sensor by confirming the surface chemistry of SWCNTs (Figure 8A) [173]. In this method, a CD63-specific aptamer was conjugated to SWCNTs, to improve the peroxidase activity of SWCNTs. This induced a bright blue color from the TMB solution. When the SWCNTs were exposed to exosomes, the aptamers bound to CD63 on exosomes and are thus were disposed from the SWCNTs. This resulted in a reduction in the peroxidase activity of the SWCNTs and thus a reduction in the color intensity of TMB. Although this method is not super sensitive (LOD = 5.2 × 108 exosomes/mL), it is very simple and easily accessible to the general public, as it can be detected using the naked eye or regular a UV-Vis spectrometer.
Another interesting application is to use CNTs as a quencher to develop a fluorometric nanosensor for exosome detection and quantification, as shown by Tayebi et al. (Figure 8B) [174]. In this method, MoS2-MWCNT was modified with PE-conjugated CD63 antibody. The fluorescence of PE on the CD63 antibody was quenched using the MoS2-MWCNT in the absence of exosomes. In the presence of exosomes, the PE-conjugated CD63 antibody binds to exosomes and thus leaves the MoS2-MWCNT, which recovers the fluorescence of PE molecules, so as to quantitatively measure the level of exosomes with targeted surface protein markers.
Li et al. have developed a field-effect transistor (FET) biosensor for the detection of miRNA from tumor exosomes by making a polymer-sorted high purity semiconducting CNT film on a Si/SiO2 substrate [175] (Figure 8C). On top of the CNT film, a thin film (3 nm) of yttrium was deposited by electron beam evaporation (EBE) and oxidized to yttrium oxide, to form an insulating layer. Then, Au was deposited by EBE to form AuNPs to anchor the oligonucleotide. This oligonucleotide probe binds to miRNA via hybridization, to induce current changes, allowing the detection and quantification of exosomes. This FET sensor achieved a sensitivity of 0.87 aM miRNA.
CNTs can also be used to develop electrochemical-based EV sensors. For example, Si et al. reported electrochemcial detection of lung cancer exosomes using DNA/ferrocene-modified SWCNT [176]. Sahraei et al. developed a biodegradable electrochemical paper-based device (ePAD) by incorporating synthetic carbon, a silver ink screen, and AuNPs on paper [177]. CD9 antibodies were coordinated on the surface of the nanocomposites for detection. This sensor exhibited superior sensitivity, with a LOD of 7 × 104 exosomes/mL. In the studies by Hashkavayi, MWCNT, ionic liquid, and chitosan were incorporated onto a screen-printed carbon electrode and modified with CD63, to capture exosomes (Figure 7D) [178]. Then, the EpCAM or HER2 positive exosomes bound to a EpCAM or HER2 aptamer, with primer sequences that acted as a rolling circle amplification (RCA) reaction initiator. After RCA, the addition of copper and lead ions led to strong electrochemical signals that were measured by DPV due to their complexation with the RCA products.
Figure 8. Exosome detection with CNTs. (a) Schematic of a colorimetric aptasensor based on DNA−capped SWCNTs for exosome detection. Reprinted with permission from ref. [173]. Copyright@ 2017 Elsevier B.V. (b) Schematic of the detection mechanism of a MoS2−MWCNT-based nanosensor for exosome detection and quantification. Reproduced from ref. [174] with permission from the Royal Society of Chemistry. (c) Schematic of the detection of exosomal miRNA21 using DNA-functionalized CNT FET biosensor. Reprinted with permission from [175]. Copyright {2021} American Chemical Society. (d) Schematic of an electrochemical aptasensor for the multiplexed detection of exosome biomarkers. Reprinted with permission from ref. [178]. Copyright@ 2017 Elsevier.
Figure 8. Exosome detection with CNTs. (a) Schematic of a colorimetric aptasensor based on DNA−capped SWCNTs for exosome detection. Reprinted with permission from ref. [173]. Copyright@ 2017 Elsevier B.V. (b) Schematic of the detection mechanism of a MoS2−MWCNT-based nanosensor for exosome detection and quantification. Reproduced from ref. [174] with permission from the Royal Society of Chemistry. (c) Schematic of the detection of exosomal miRNA21 using DNA-functionalized CNT FET biosensor. Reprinted with permission from [175]. Copyright {2021} American Chemical Society. (d) Schematic of an electrochemical aptasensor for the multiplexed detection of exosome biomarkers. Reprinted with permission from ref. [178]. Copyright@ 2017 Elsevier.
Nanomaterials 13 00524 g008

6.2. Carbon Nanosheet

Graphitic carbon nitride nanosheets (g-C3N4 NSs) are two-dimension nanomaterials with graphene-like properties, which have been used for various applications, from materials science to disease diagnostics [179,180,181]. An example using g-C3N4 NSs for EV detection was demonstrated by Wang et al., who exploited the peroxidase-like activities of the nanosheet for colorimetric detection of exosomes [182]. Without exosomes, the single stranded DNA (ssDNA) adsorbed on g-C3N4 NSs enhanced the catalytic activity of the nanosheet, and thus TMB was strongly oxidized by H2O2, to give an intense blue color. In the presence of exosomes, however, the ssDNA binds to the targeted surface proteins on exosomes. Thus, the catalytic activity of the g-C3N4 NSs was not enhanced and the TMB oxidation by H2O2 was only moderate. Under this situation, the color of the oxidized TMB was weaker than the control without exosomes. This sensor was sensitive, capable of differentiating the level of CD63 expression on exosomes between MCF7 breast cancer cells and MCF-1-A normal cells.

6.3. Graphene

Graphene is a two-dimension sheet of SP2 hybridized carbon atoms [183]. The long range pi conjugation in graphene leads to outstanding electrical, thermal, and mechanical properties [184]. These properties have been recently used for molecular detection and analysis of circulating biomarkers including EVs [185]. The electrical property of graphene and graphene oxide provide an excellent opportunity to design field-effect-transistor (FET)-based biosensors for EV detection [186,187,188,189,190]. For example, Tsang et al. fabricated a back-gated graphene FET biosensor by depositing a graphene monolayer onto a microfluidic device by chemical vapor deposition [186]. Functionalization of the graphene surface with CD63 antibodies captured the exosomes. The microfluidic channel separates the graphene into sample touched and sample-free areas. These two areas exhibit different electric properties and can sensor the binding of exosomes in the solution using the current. This sensor exhibited a LOD down to 0.1 µg/mL. In another study, Yu et al. fabricated a reduced graphene oxide (RGO) FET, functionalized with CD63 to capture and detect exosomes [187]. This method achieved a low LOD of 3.3 × 104 exosomes/mL. This label-free technique can directly quantify exosomes in serum samples and has shown diagnostic potential for prostate cancer. Additionally, the porous structure has been used to isolate exosomes with and without other isolation materials and devices [191,192,193].

7. Other Nanomaterials

In addition to the nanomaterials discussed above, various other nanomaterials have also been reported including polymer nanowires [194], DNA nanomaterials [195,196,197,198,199,200,201], fluorescent metal compound NPs [202], and lipid-based NPs [203]. For example, He et al. developed a aptamer-based fluorescence DNA nanodevice (ABDNs) to visualize and quantify exosomes in plasma samples at single vesicle level [201]. The high sensitivity was driven by the HCR of the aptamer probe on the surface of exosomes using fluorescence molecular hairpins. The HCR led to nanoscale DNA long chains on the surface of the exosomes, allowing fluorescent detection of single exosomes. In another DNA-based platform by Zhao et al., exosomes with aptamers were detected through the detection of exosomal DNAs [199]. Target-specific recognition was amplified by the movement of a 3-D DNA walker and then detected by an electrochemical ratiometric sensor. This approach achieved a LOD of 1.3 × 104 exosomes/mL.

8. Summary and Perspective

We have summarized and discussed recent analytical technologies and devices that made use of classic nanomaterials for the detection of proteins and nucleic acids of exosomes and microvesicles (Table 1). These nanomaterials were used either alone or with other nanomaterials or molecules for molecular EV detection, with different mechanisms such as light scattering imaging, fluorescence detection, and electrochemical sensing. The detection sensitivity had a varied ranged, from 108 EVs/mL down to single EV, depending on the type of nanomaterials and the signal readout. The most widely used nanomaterials were plasmonic NPs, due to their wide range of properties, including plasmonic sensing, light scattering, SERS, and fluorescence.
While nanomaterials and associated technologies are promising and have significant advantages over other existing technologies, they also have some limitations. One generic limitation is the challenge in the detection of small EVs at single vesicle level. Except QDs, the size of NPs is usually large and more than 20 nm. Attachment with target ligands such as antibodies further increases the particle’s size. However, EVs can be as small as 30 nm. In our studies, we showed that only one AuNP of 60 nm in diameter can bind to an EV of 40 nm in diameter [68]. They cannot detect EVs smaller than 40 nm. Such sized AuNPs cannot be used to quantify a number of the targeted surface proteins. The additional limitations of each type of nanomaterial-based technique depend on the structural and functional properties of nanomaterials. For example, the µMR devices using MNPs are sophisticated and require specialized skills and personnel to operate; similarly to the electrochemical sensors that require expertise in electric chemistry. The colorimetric detection approaches are easy and inexpensive, but they typically have a limited sensitivity.
Despite these limitations, the popularity of nanomaterials for molecular EV detection and analysis is expected to rise rapidly, owing to the unique structural and functional properties of nanoscale materials and devices. In particular, research is going to focus on single EV detection. This is because EVs are heterogeneous, and disease-derived EVs are mixed with a vast background of non-tumor EVs from various tissues and hematopoietic cells. The bulk methods are inherently contaminated with normal exosomes, which masks EV heterogeneity and limits the sensitivity of detection in analyzing clinical samples. To more sensitively, precisely, and quantitatively detect, monitor, and investigate cancer EVs, EVs need to be analyzed at the single vesicle level. Different single vesicle technologies have been reported in recent years [204]. We expect nanomaterials will play a rapidly increasing role in the development of new SVTs for EV protein and nucleic acid detection and profiling, for basic vesicle research and clinical applications.

Author Contributions

Writing-original draft preparation, M.L.T., A.G.G. and K.D.A.; writing—review and editing, R.E.W.J., Y.W. and X.H.; funding acquisition, Y.W. and X.H. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the National Institutes of Health/National Cancer Institute (Grant no. 1R15CA238890-01A1).

Data Availability Statement

Not applicable.

Acknowledgments

Y.W. and X.H. thank the National Institutes of Health/National Cancer Institute for the financial support (Grant no. 1R15CA238890-01A1).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Huang, X.; O’Connor, R.; Kwizera, E.A. Gold Nanoparticle Based Platforms for Circulating Cancer Marker Detection. Nanotheranostics 2017, 1, 80–102. [Google Scholar] [CrossRef] [PubMed]
  2. Fais, S.; O’Driscoll, L.; Borras, F.E.; Buzas, E.; Camussi, G.; Cappello, F.; Carvalho, J.; Cordeiro da Silva, A.; Del Portillo, H.; El Andaloussi, S.; et al. Evidence-Based Clinical Use of Nanoscale Extracellular Vesicles in Nanomedicine. ACS Nano 2016, 10, 3886–3899. [Google Scholar] [CrossRef]
  3. Xu, R.; Rai, A.; Chen, M.; Auwakulsiri, W.; Greening, D.W.; Simpson, R.J. Extracellular Vesicles in Cancer—Implications for Future Improvements in Cancer Care. Nat. Rev. Clin. Oncol. 2018, 15, 617–638. [Google Scholar] [CrossRef]
  4. Yu, D.; Li, Y.; Wang, M.; Gu, J.; Xu, W.; Cai, H.; Fang, X.; Zhang, X. Exosomes as a New Frontier of Cancer Liquid Biopsy. Mol. Cancer 2022, 21, 56. [Google Scholar] [CrossRef]
  5. Kalluri, R.; LeBleu, V.S. The Biology, Function, and Biomedical Applications of Exosomes. Science 2020, 367, eaau6977. [Google Scholar] [CrossRef]
  6. van Niel, G.; D’Angelo, G.; Raposo, G. Shedding Light on the Cell Biology of Extracellular Vesicles. Nat. Rev. Mol. Cell Biol. 2018, 19, 213–228. [Google Scholar] [CrossRef]
  7. Teng, F.; Fussenegger, M. Shedding Light on Extracellular Vesicle Biogenesis and Bioengineering. Adv. Sci. 2021, 8, 2003505. [Google Scholar] [CrossRef]
  8. D’Souza-Schorey, C.; Di Vizio, D. Biology and Proteomics of Extracellular Vesicles: Harnessing Their Clinical Potential. Expert Rev. Proteom. 2014, 11, 251–253. [Google Scholar] [CrossRef] [Green Version]
  9. Zaborowski, M.P.; Balaj, L.; Breakefield, X.O.; Lai, C.P. Extracellular Vesicles: Composition, Biological Relevance, and Methods of Study. BioScience 2015, 65, 783–797. [Google Scholar] [CrossRef] [Green Version]
  10. Mashouri, L.; Yousefi, H.; Aref, A.R.; Ahadi, A.M.; Molaei, F.; Alahari, S.K. Exosomes: Composition, Biogenesis, and Mechanisms in Cancer Metastasis and Drug Resistance. Mol. Cancer 2019, 18, 75. [Google Scholar] [CrossRef] [PubMed]
  11. Zhang, H.-G. (Ed.) Emerging Concepts of Tumor Exosome–Mediated Cell-Cell Communication; Springer: New York, NY, USA, 2013; ISBN 978-1-4614-3696-6. [Google Scholar]
  12. Rak, J. Extracellular Vesicles—Biomarkers and Effectors of the Cellular Interactome in Cancer. Front. Pharmacol. 2013, 4, 21. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  13. Zhang, W.E.; Grizzle, H.G. A Novel Pathway of Local and Distant Intercellular Communication That Facilitates the Growth and Metastasis of Neoplastic Lesions. Am. J. Pathol. 2014, 184, 28–41. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  14. Lowry, M.C.; Gallagher, W.M.; O’Driscoll, L. The Role of Exosomes in Breast Cancer. Clin. Chem. 2015, 61, 1457–1465. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Rajagopal, C.; Harikumar, K.B. The Origin and Functions of Exosomes in Cancer. Front. Oncol. 2018, 8, 66. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  16. McAndrews, K.M.; Kalluri, R. Mechanisms Associated with Biogenesis of Exosomes in Cancer. Mol. Cancer 2019, 18, 52. [Google Scholar] [CrossRef] [PubMed]
  17. Syn, N.; Wang, L.; Sethi, G.; Thiery, J.-P.; Goh, B.-C. Exosome-Mediated Metastasis: From Epithelial–Mesenchymal Transition to Escape from Immunosurveillance. Trends Pharmacol. Sci. 2016, 37, 606–617. [Google Scholar] [CrossRef]
  18. Sauter, E.R. Exosomes in Blood and Cancer. Transl. Cancer Res. 2017, 6, S1316–S1320. [Google Scholar] [CrossRef]
  19. Pisitkun, T.; Shen, R.-F.; Knepper, M.A. Identification and Proteomic Profiling of Exosomes in Human Urine. Proc. Natl. Acad. Sci. USA 2004, 101, 13368–13373. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Nair, S.; Tang, K.D.; Kenny, L.; Punyadeera, C. Salivary Exosomes as Potential Biomarkers in Cancer. Oral Oncol. 2018, 84, 31–40. [Google Scholar] [CrossRef]
  21. Runz, S.; Keller, C.; Rupp, A.; Stoeck, Y.; Issa, D.; Koensgen, A.; Mustea, J.; Sehouli, G.; Kristiansen, P.; Altevogt, S. Malignant Ascites-Derived Exosomes of Ovarian Carcinoma Patients Contain CD24 and EpCAM. Gynecol. Oncol. 2007, 107, 563–571. [Google Scholar] [CrossRef]
  22. Whitehead, C.A.; Luwor, R.B.; Morokoff, A.P.; Kaye, A.H.; Stylli, S.S. Cancer Exosomes in Cerebrospinal Fluid. Transl. Cancer Res. 2017, 6, 19. [Google Scholar] [CrossRef]
  23. Properzi, M.; Logozzi, S.; Fais, F. Exosomes: The Future of Biomarkers in Medicine. Biomarkers Med. 2013, 7, 769–778. [Google Scholar] [CrossRef] [PubMed]
  24. Li, M.; Kaslan, S.H.; Lee, J.; Yao, Z.; Gao, P. Progress in Exosome Isolation Techniques. Theranostics 2017, 7, 789–804. [Google Scholar] [CrossRef] [PubMed]
  25. Hartjes, S.; Mytnyk, G.W.; Jenster, V.; van Steijn, M.E.; van Royen, T.A. Extracellular Vesicle Quantification and Characterization: Common Methods and Emerging Approaches. Bioengineering 2019, 6, 7. [Google Scholar] [CrossRef] [Green Version]
  26. Zhang, L.; Gu, C.; Wen, J.; Liu, G.; Liu, H.; Li, L. Recent Advances in Nanomaterial-Based Biosensors for the Detection of Exosomes. Anal. Bioanal. Chem. 2021, 413, 83–102. [Google Scholar] [CrossRef]
  27. Fang, X.; Wang, Y.; Wang, S.; Liu, B. Nanomaterials Assisted Exosomes Isolation and Analysis towards Liquid Biopsy. Mater. Today Bio. 2022, 16, 100371. [Google Scholar] [CrossRef]
  28. Lee, M.; Kim, J.; Jang, M.; Park, C.; Lee, J.-H.; Lee, T. Introduction of Nanomaterials to Biosensors for Exosome Detection: Case Study for Cancer Analysis. Biosensors 2022, 12, 648. [Google Scholar] [CrossRef]
  29. Wang, N.; Yuan, S.; Fang, C.; Hu, X.; Zhang, Y.-S.; Zhang, L.-L.; Zeng, X.-T. Nanomaterials-Based Urinary Extracellular Vesicles Isolation and Detection for Non-Invasive Auxiliary Diagnosis of Prostate Cancer. Front. Med. 2022, 8, 800889. [Google Scholar] [CrossRef]
  30. Hsu, C.-C.; Wu, Y. Recent Advances in Nanotechnology-Enabled Biosensors for Detection of Exosomes as New Cancer Liquid Biopsy. Exp. Biol. Med. 2022, 247, 2152–2172. [Google Scholar] [CrossRef]
  31. Wang, Y.; Wang, W.; Kong, F.; Zhang, Q.; Xiao, J.; Zhang, Y.; Yan, B. Tango of Dual Nanoparticles: Interplays between Exosomes and Nanomedicine. Bioeng. Transl. Med. 2022, 7, e10269. [Google Scholar] [CrossRef]
  32. Im, H.; Shao, H.; Park, Y.I.; Peterson, V.M.; Castro, C.M.; Weissleder, R.; Lee, H. Label-Free Detection and Molecular Profiling of Exosomes with a Nano-Plasmonic Sensor. Nat. Biotechnol. 2014, 32, 490–495. [Google Scholar] [CrossRef] [Green Version]
  33. Liang, K.; Liu, F.; Fan, J.; Sun, D.; Liu, C.; Lyon, C.J.; Bernard, D.W.; Li, Y.; Yokoi, K.; Katz, M.H.; et al. Nanoplasmonic Quantification of Tumour-Derived Extracellular Vesicles in Plasma Microsamples for Diagnosis and Treatment Monitoring. Nat. Biomed. Eng. 2017, 1, 21. [Google Scholar] [CrossRef] [Green Version]
  34. Kwizera, R.; O’Connor, V.; Vinduska, M.; Wiliams, E.R.; Butch, S.E.; Snyder, X.; Chen, X.; Huang, A. Molecular Detection and Analysis of Exosomes Using Surface Enhanced Raman Scattering Gold Nanorods and a Miniaturized Device. Theranostics 2018, 8, 2722–2738. [Google Scholar] [CrossRef]
  35. Guo, X. Surface Plasmon Resonance Based Biosensor Technique: A Review. J. Biophotonics 2012, 5, 483–501. [Google Scholar] [CrossRef]
  36. Daniel, M.-C.; Astruc, D. Gold Nanoparticles: Assembly, Supramolecular Chemistry, Quantum-Size-Related Properties, and Applications toward Biology, Catalysis, and Nanotechnology. Chem. Rev. 2004, 104, 293–346. [Google Scholar] [CrossRef]
  37. Paciotti, G.F.; Kingston, D.G.; Tamarkin, L. Colloidal Gold Nanoparticles: A Novel Nanoparticle Platform for Developing Multifunctional Tumor-Targeted Drug Delivery Vectors. Drug Dev. Res. 2006, 67, 47–54. [Google Scholar] [CrossRef]
  38. Huang, X.; Jain, P.K.; El-Sayed, I.H.; El-Sayed, M.A. Gold Nanoparticles: Interesting Optical Properties and Recent Applications in Cancer Diagnostics and Therapy. Nanomedicine 2007, 2, 681–693. [Google Scholar] [CrossRef] [Green Version]
  39. Huang, M.A.; El-Sayed, X. Gold Nanoparticles: Optical Properties and Implementations in Cancer Diagnosis and Photothermal Therapy. J. Adv. Res. 2010, 1, 13–28. [Google Scholar] [CrossRef] [Green Version]
  40. Dreaden, A.M.; Alkilany, X.; Huang, C.J.; Murphy, M.A.; El-Sayed, E.C. The Golden Age: Gold Nanoparticles for Biomedicine. Chem. Soc. Rev. 2012, 41, 2740–2779. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  41. Abadeer, N.S.; Murphy, C.J. Recent Progress in Cancer Thermal Therapy Using Gold Nanoparticles. J. Phys. Chem. C 2016, 120, 4691–4716. [Google Scholar] [CrossRef]
  42. Link, S.; El-Sayed, M.A. Size and Temperature Dependence of the Plasmon Absorption of Colloidal Gold Nanoparticles. J. Phys. Chem. B 1999, 103, 4212–4217. [Google Scholar] [CrossRef]
  43. Link, M.A.; El-Sayed, S. Spectral Properties and Relaxation Dynamics of Surface Plasmon Electronic Oscillations in Gold and Silver Nanodots and Nanorods. J. Phys. Chem. B 1999, 103, 8410–8426. [Google Scholar] [CrossRef]
  44. Link, S.; El-Sayed, M.A. Shape and Size Dependence of Radiative, Non-Radiative and Photothermal Properties of Gold Nanocrystals. Int. Rev. Phys. Chem. 2000, 19, 409–453. [Google Scholar] [CrossRef]
  45. Murphy, C.J.; Sau, T.K.; Gole, A.M.; Orendorff, C.J.; Gao, J.; Gou, L.; Hunyadi, S.E.; Li, T. Anisotropic Metal Nanoparticles: Synthesis, Assembly, and Optical Applications. J. Phys. Chem. B 2005, 109, 13857–13870. [Google Scholar] [CrossRef] [PubMed]
  46. Eustis, S.; El-Sayed, M.A. Why Gold Nanoparticles Are More Precious than Pretty Gold: Noble Metal Surface Plasmon Resonance and Its Enhancement of the Radiative and Nonradiative Properties of Nanocrystals of Different Shapes. Chem. Soc. Rev. 2006, 35, 209–217. [Google Scholar] [CrossRef]
  47. Li, P.; Zhao, D.; Astruc, N. Anisotropic Gold Nanoparticles: Synthesis, Properties, Applications, and Toxicity. Angew. Chem. Int. Ed. 2014, 53, 1756–1789. [Google Scholar] [CrossRef]
  48. Pérez-Juste, J.; Pastoriza-Santos, I.; Liz-Marzán, L.M.; Mulvaney, P. Gold Nanorods: Synthesis, Characterization and Applications. Coord. Chem. Rev. 2005, 249, 1870–1901. [Google Scholar] [CrossRef]
  49. Huang, S.; Neretina, M.A.; El-Sayed, X. Gold Nanorods: From Synthesis and Properties to Biological and Biomedical Applications. Adv. Mater. 2009, 21, 4880–4910. [Google Scholar] [CrossRef]
  50. Huang, X.; El-Sayed, M.A. Plasmonic Photo-Thermal Therapy (PPTT). Alex. J. Med. 2011, 47, 1–9. [Google Scholar] [CrossRef] [Green Version]
  51. Lee, M.A.; El-Sayed, S.K. Gold and Silver Nanoparticles in Sensing and Imaging: Sensitivity of Plasmon Response to Size, Shape, and Metal Composition. J. Phys. Chem. B 2006, 110, 19220. [Google Scholar] [CrossRef]
  52. Yguerabide, J.; Yguerabide, E.E. Light-Scattering Submicroscopic Particles as Highly Fluorescent Analogs and Their Use as Tracer Labels in Clinical and Biological Applications. I. Theory. Anal. Biochem. 1998, 262, 137–156. [Google Scholar] [CrossRef]
  53. Yguerabide, J.; Yguerabide, E.E. Light-Scattering Submicroscopic Particles as Highly Fluorescent Analogs and Their Use as Tracer Labels in Clinical and Biological Applications. II. Experimental Characterization. Anal. Biochem. 1998, 262, 157–186. [Google Scholar] [CrossRef] [PubMed]
  54. Yguerabide, J.; Yguerabide, E.E. Resonance Light Scattering Particles as Ultrasensitive Labels for Detection of Analytes in a Wide Range of Applications. J. Cell Biochem. Supp. 2001, 37, 71–81. [Google Scholar] [CrossRef]
  55. Lance, K.K.; Coronado, E.; Zhao, L.L.; Schatz, G.C. The Optical Properties of Metal Nanoparticles: The Influence of Size, Shape, and Dielectric Environment. J. Phys. Chem. B 2003, 107, 668–677. [Google Scholar]
  56. Kneipp, K.; Kneipp, H.; Itzkan, I.; Dasari, R.R.; Feld, M.S. Surface-Enhanced Raman Scattering and Biophysics. J. Phys. Condens. Matter 2002, 14, R597–R624. [Google Scholar] [CrossRef] [Green Version]
  57. Falkowski, P.; Lukaszewski, Z.; Gorodkiewicz, E. Potential of Surface Plasmon Resonance Biosensors in Cancer Detection. J. Pharm. Biomed. Anal. 2021, 194, 113802. [Google Scholar] [CrossRef] [PubMed]
  58. Grasso, R.; Wyss, L.; Weidenauer, A.; Thampi, D.; Demurtas, M.; Prudent, N.; Lion, H.; Vogel, L. Molecular Screening of Cancer-Derived Exosomes by Surface Plasmon Resonance Spectroscopy. Anal. Bioanal. Chem. 2015, 407, 5425–5432. [Google Scholar] [CrossRef] [Green Version]
  59. Sina, A.A.I.; Vaidyanathan, R.; Dey, S.; Carrascosa, L.G.; Shiddiky, M.J.; Trau, M. Real Time and Label Free Profiling of Clinically Relevant Exosomes. Sci. Rep. 2016, 6, 30460. [Google Scholar] [CrossRef] [Green Version]
  60. Zhu, L.; Wang, K.; Cui, J.; Liu, H.; Bu, X.; Ma, H.; Wang, W.; Gong, H.; Lausted, C.; Hood, L.; et al. Label-Free Quantitative Detection of Tumor-Derived Exosomes through Surface Plasmon Resonance Imaging. Anal. Chem. 2014, 86, 8857–8864. [Google Scholar] [CrossRef] [Green Version]
  61. Liu, C.; Zeng, X.; An, Z.; Yang, Y.; Eisenbaum, M.; Gu, X.; Jornet, J.M.; Dy, G.K.; Reid, M.E.; Gan, Q.; et al. Sensitive Detection of Exosomal Proteins via a Compact Surface Plasmon Resonance Biosensor for Cancer Diagnosis. ACS Sens. 2018, 3, 1471–1479. [Google Scholar] [CrossRef]
  62. Park, H.; Im, S.; Hong, C.M.; Castro, R.; Weissleder, H.; Lee, J. Analyses of Intravesicular Exosomal Proteins Using a Nano-Plasmonic System. ACS Photonics 2018, 5, 487–494. [Google Scholar] [CrossRef] [PubMed]
  63. Thakur, G.; Qiu, S.P.; Ng, J.; Guan, J.; Yue, Y.; Lee, C.L.; Wu, A. Direct Detection of Two Different Tumor-Derived Extracellular Vesicles by SAM-AuNIs LSPR Biosensor. Biosens. Bioelectron. 2017, 94, 400–407. [Google Scholar] [CrossRef] [PubMed]
  64. Wang, Q.; Zou, L.; Yang, X.; Liu, X.; Nie, W.; Zheng, Y.; Cheng, Q.; Wang, K. Direct Quantification of Cancerous Exosomes via Surface Plasmon Resonance with Dual Gold Nanoparticle-Assisted Signal Amplification. Biosens. Bioelectron. 2019, 135, 129–136. [Google Scholar] [CrossRef] [PubMed]
  65. Raju, D.; Bathini, S.; Badilescu, S.; Ouellette, R.J.; Ghosh, A.; Packirisamy, M. Study of Detection and Capture of Exosomes by Using the Morphologies of Ex Situ and In Situ Nanostructures. J. Electrochem. Soc. 2019, 166, B3001–B3006. [Google Scholar] [CrossRef]
  66. Chen, W.; Li, J.; Wei, X.; Fan, Y.; Qian, H.; Li, S.; Xiang, Y.; Ding, S. Surface Plasmon Resonance Biosensor Using Hydrogel-AuNP Supramolecular Spheres for Determination of Prostate Cancer-Derived Exosomes. Microchim Acta 2020, 187, 590. [Google Scholar] [CrossRef] [PubMed]
  67. Fan, Y.; Duan, X.; Zhao, M.; Wei, X.; Wu, J.; Chen, W.; Liu, P.; Cheng, W.; Cheng, Q.; Ding, S. High-Sensitive and Multiplex Biosensing Assay of NSCLC-Derived Exosomes via Different Recognition Sites Based on SPRi Array. Biosens. Bioelectron. 2020, 154, 112066. [Google Scholar] [CrossRef] [PubMed]
  68. Amrhein, K.; Taylor, M.L.; Wilson, R.; Gallops, C.E.; Annamer, A.; Vinduska, V.; Kwizera, E.A.; Zhang, H.; Wang, Y.; Hoang, T.B.; et al. Dual Imaging Single Vesicle Surface Protein Profiling and Early Cancer Detection. ACS Appl. Mater. Interfaces 2023, 15, 2679–2692. [Google Scholar] [CrossRef]
  69. Tirinato, F.; Gentile, D.; Di Mascolo, M.L.; Coluccio, G.; Das, C.; Liberale, S.A.; Pullano, G.; Perozziello, M.; Francardi, A.; Accardo, F.; et al. SERS Analysis on Exosomes Using Super-Hydrophobic Surfaces. Microelectron. Eng. 2012, 97, 337–340. [Google Scholar] [CrossRef]
  70. Lee, R.P.; Carney, S.; Hazari, Z.J.; Smith, A.; Knudson, C.S.; Robertson, K.S.; Lam, S.; Wachsmann-Hogiu, C. 3D Plasmonic Nanobowl Platform for the Study of Exosomes in Solution. Nanoscale 2015, 7, 9290–9297. [Google Scholar] [CrossRef]
  71. Park, M.; Hwang, B.H.; Choi, H.; Jeong, J.; Jung, H.K.; Kim, S.; Hong, J.; Park, Y.; Choi, J. Exosome Classification by Pattern Analysis of Surface-Enhanced Raman Spectroscopy Data for Lung Cancer Diagnosis. Anal. Chem. 2017, 89, 6695–6701. [Google Scholar] [CrossRef]
  72. Carmicheal, J.; Hayashi, C.; Huang, X.; Liu, L.; Lu, Y.; Krasnoslobodtsev, A.; Lushnikov, A.; Kshirsagar, P.G.; Patel, A.; Jain, M.; et al. Label-Free Characterization of Exosome via Surface Enhanced Raman Spectroscopy for the Early Detection of Pancreatic Cancer. Nanomed: Nanotechnol. Bio. Med. 2019, 16, 88–96. [Google Scholar] [CrossRef]
  73. Ferreira, N.; Marques, A.; Águas, H.; Bandarenka, H.; Martins, R.; Bodo, C.; Costa-Silva, B.; Fortunato, E. Label-Free Nanosensing Platform for Breast Cancer Exosome Profiling. ACS Sens. 2019, 4, 2073–2083. [Google Scholar] [CrossRef]
  74. Chen, H.; Luo, C.; Yang, M.; Li, J.; Ma, P.; Zhang, X. Intracellular Uptake of and Sensing with SERS-Active Hybrid Exosomes: Insight into a Role of Metal Nanoparticles. Nanomedicine 2020, 15, 913–926. [Google Scholar] [CrossRef]
  75. Stremersch, M.; Marro, B.; Pinchasik, P.; Baatsen, A.; Hendrix, S.C.; De Smedt, P.; Loza-Alvarez, A.G.; Skirtach, K.; Raemdonck, K.; Braeckmans, S. Identifi Cation of Individual Exosome-like Vesicles by Surface Enhanced Raman Spectroscopy. Small 2016, 12, 3292–3301. [Google Scholar] [CrossRef] [PubMed]
  76. Zong, S.; Wang, L.; Chen, C.; Lu, J.; Zhu, D.; Zhang, Y.; Wang, Z.; Cui, Y. Facile Detection of Tumor-Derived Exosomes Using Magnetic Nanobeads and SERS Nanoprobes. Analy. Methods 2016, 8, 5001–5008. [Google Scholar] [CrossRef]
  77. Sivashanmugan, K.; Huang, W.-L.; Lin, C.-H.; Liao, J.-D.; Lin, C.-C.; Su, W.-C.; Wen, T.-C. Bimetallic Nanoplasmonic Gap-Mode SERS Substrate for Lung Normal and Cancer-Derived Exosomes Detection. J. Tianwan Inst. Chem. Eng. 2017, 80, 149–155. [Google Scholar] [CrossRef]
  78. Koczula, K.M.; Gallotta, A. Lateral Flow Assays. Essays Biochem. 2016, 60, 111–120. [Google Scholar] [CrossRef] [PubMed]
  79. Liu, Y.; Zhan, L.; Qin, Z.; Sackrison, J.; Bischof, J.C. Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis. ACS Nano 2021, 15, 3593–3611. [Google Scholar] [CrossRef]
  80. Mirica, A.-C.; Stan, D.; Chelcea, I.-C.; Mihailescu, C.M.; Ofiteru, A.; Bocancia-Mateescu, L.-A. Latest Trends in Lateral Flow Immunoassay (LFIA) Detection Labels and Conjugation Process. Front. Bioeng. Biotechnol. 2022, 10, 922772. [Google Scholar] [CrossRef]
  81. Oliveira-Rodríguez, S.; López-Cobo, H.T.; Reyburn, A.; Costa-García, S.; López Martín, S.M.; Yáñez-Mo, E.; Cernuda-Morollón, A.; Paschen, M.; Valés-Gómez, M.C.; Blanco-López, M. Development of a Rapid Lateral Flow Immunoassay Test for Detection of Exosomes Previously Enriched from Cell Culture Medium and Body Fluids. J. Extracell. Vesicles 2016, 5, 31803–31813. [Google Scholar] [CrossRef] [Green Version]
  82. Oliveira-Rodríguez, E.; Serrano-Pertierra, A.C.; García, S.L.; Martín, M.Y.; Mo, E.; Cernuda-Morollón, M.C.; Blanco-López, M. Point-of-Care Detection of Extracellular Vesicles: Sensitivity Optimization and Multiple-Target Detection. Biosens. Bioelectron. 2017, 87, 38–45. [Google Scholar] [CrossRef]
  83. Jiang, Y.; Shi, M.; Liu, Y.; Wan, S.; Cui, C.; Zhang, L.; Tan, W. Aptamer/AuNP Biosensor for Colorimetric Profiling of Exosomal Proteins. Angew. Chem. Int. Ed. 2017, 56, 11916–11920. [Google Scholar] [CrossRef]
  84. Di, H.; Mi, Z.; Sun, Y.; Liu, X.; Liu, X.; Li, A.; Jiang, Y.; Gao, H.; Rong, P.; Liu, D. Nanozyme-Assisted Sensitive Profiling of Exosomal Proteins for Rapid Cancer Diagnosis. Theranostics 2020, 10, 9303–9314. [Google Scholar] [CrossRef] [PubMed]
  85. Zhou, H.; Du, X.; Zhang, Z. Electrochemical Sensors for Detection of Markers on Tumor Cells. Int. J. Mol. Sci. 2021, 22, 8184. [Google Scholar] [CrossRef] [PubMed]
  86. Grieshaber, D.; MacKenzie, R.; Vörös, J.; Reimhult, E. Electrochemical Biosensors—Sensor Principles and Architectures. Sensors 2008, 8, 1400–1458. [Google Scholar] [CrossRef]
  87. Vaidyanathan, M.; Naghibosadat, S.; Rauf, D.; Korbie, L.G.; Carrascosa, M.J.A.; Shiddiky, M.; Trau, R. Detecting Exosomes Specifically: A Multiplexed Device Based on Alternating Current Electrohydrodynamic Induced Nanoshearing. Anal. Chem. 2014, 86, 11125–11132. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  88. Doldán, P.; Fagúndez, A.; Cayota, J.; Laíz, J.P.; Tosar, X. Electrochemical Sandwich Immunosensor for Determination of Exosomes Based on Surface Marker-Mediated Signal Amplification. Anal. Chem. 2016, 88, 10466–10473. [Google Scholar] [CrossRef] [PubMed]
  89. Jeong, J.; Park, D.; Pathania, C.M.; Castro, R.; Weissleder, H.; Lee, S. Integrated Magneto–Electrochemical Sensor for Exosome Analysis. ACS Nano 2016, 10, 1802–1809. [Google Scholar] [CrossRef] [Green Version]
  90. Li, G.K.; Tofaris, J.J.; Davis, Q. Concentration-Normalized Electroanalytical Assaying of Exosomal Markers. Anal. Chem. 2017, 9, 3184–3190. [Google Scholar] [CrossRef]
  91. Wang, L.; Zeng, L.; Wang, Y.; Chen, T.; Chen, W.; Chen, G.; Li, C.; Chen, J. Electrochemical Aptasensor Based on Multidirectional Hybridization Chain Reaction for Detection of Tumorous Exosomes. Sens. Actuators B Chem. 2021, 332, 129471. [Google Scholar] [CrossRef]
  92. Fan, C.; Jiang, B.; Shi, W.; Chen, D.; Zhou, M. Tri-Channel Electrochemical Immunobiosensor for Combined Detections of Multiple Exosome Biomarkers of Lung Cancer. Biosensors 2022, 12, 435. [Google Scholar] [CrossRef] [PubMed]
  93. Zhang, J.; Hao, L.; Zhao, Z.; Jiang, D.; Chao, J. Multiple Signal Amplification Electrochemiluminescence Biosensor for Ultra-Sensitive Detection of Exosomes. Sens. Actuators B Chem. 2022, 369, 132332. [Google Scholar] [CrossRef]
  94. Pumera, S.; Sanchez, I.; Ichinose, J.; Tang, M. Electrochemical Nanobiosensors. Sens. Actuators B Chem. 2007, 123, 1195–1205. [Google Scholar] [CrossRef]
  95. O’Riordan, A.; Barry, S. Electrochemical Nanosensors: Advances and Applications. Rep. Electrochem. 2016, 2016, 1–14. [Google Scholar]
  96. Lee, S.; Crulhas, B.P.; Suvakov, S.; Verkhoturov, S.V.; Verkhoturov, D.S.; Eller, M.J.; Malhi, H.; Garovic, V.D.; Schweikert, E.A.; Stybayeva, G.; et al. Nanoparticle-Enabled Multiplexed Electrochemical Immunoassay for Detection of Surface Proteins on Extracellular Vesicles. ACS Appl. Mater. Interfaces 2021, 13, 52321–52332. [Google Scholar] [CrossRef]
  97. Hu, C.; Yang, D.-P.; Xu, K.; Cao, H.; Wu, B.; Cui, D.; Jia, N. Ag@BSA Core/Shell Microspheres As an Electrochemical Interface for Sensitive Detection of Urinary Retinal-Binding Protein. Anal. Chem. 2012, 84, 10324–10331. [Google Scholar] [CrossRef]
  98. Rasheed, P.A.; Sandhyarani, N. Electrochemical DNA Sensors Based on the Use of Gold Nanoparticles: A Review on Recent Developments. Microchim. Acta 2017, 184, 981–1000. [Google Scholar] [CrossRef]
  99. Zhou, R.M.; Mohamadi, M.; Poudineh, L.; Kermanshah, S.; Ahmed, T.S.; Safaei, J.; Stojcic, R.K.; Nam, E.H.; Sargent, S.O.; Kelley, Y.G. Interrogating Circulating Microsomes and Exosomes Using Metal Nanoparticles. Small 2016, 12, 727–732. [Google Scholar] [CrossRef]
  100. Etayash, A.R.; McGee, K.; Kaur, T.; Thundat, H. Nanomechanical Sandwich Assay for Multiple Cancer Biomarkers in Breast Cancer Cell-Derived Exosomes. Nanoscale 2016, 8, 15137–15141. [Google Scholar] [CrossRef] [PubMed]
  101. Betzer, O.; Perets, N.; Angel, A.; Motiei, M.; Sadan, T.; Yadid, G.; Offen, D.; Popovtzer, R. In Vivo Neuroimaging of Exosomes Using Gold Nanoparticles. ACS Nano 2017, 11, 10883–10893. [Google Scholar] [CrossRef]
  102. Huang, L.; Wang, D.-B.; Singh, N.; Yang, F.; Gu, N.; Zhang, X.-E. A Dual-Signal Amplification Platform for Sensitive Fluorescence Biosensing of Leukemia-Derived Exosomes. Nanoscale 2018, 10, 20289–20295. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  103. Zhai, L.-Y.; Li, M.-X.; Pan, W.-L.; Chen, Y.; Li, M.-M.; Pang, J.-X.; Zheng, L.; Chen, J.-X.; Duan, W.-J. In Situ Detection of Plasma Exosomal MicroRNA-1246 for Breast Cancer Diagnostics by a Au Nanoflare Probe. ACS Appl. Mater. Interfaces 2018, 10, 39478–39486. [Google Scholar] [CrossRef] [PubMed]
  104. Gao, M.-L.; Yin, B.-C.; Ye, B.-C. Construction of a DNA-AuNP-Based Satellite Network for Exosome Analysis. Analyst 2019, 144, 5996–6003. [Google Scholar] [CrossRef]
  105. Lyu, Y.; Cui, D.; Huang, J.; Fan, W.; Miao, Y.; Pu, K. Near-Infrared Afterglow Semiconducting Nano-Polycomplexes for the Multiplex Differentiation of Cancer Exosomes. Angew. Chem. Int. Ed. 2019, 131, 5037–5041. [Google Scholar] [CrossRef]
  106. Wang, C.; Wang, C.; Jin, D.; Yu, Y.; Yang, F.; Zhang, Y.; Yao, Q.; Zhang, G.-J. AuNP-Amplified Surface Acoustic Wave Sensor for the Quantification of Exosomes. ACS Sens. 2020, 5, 362–369. [Google Scholar] [CrossRef] [PubMed]
  107. Zhang, H.; Wang, Z.; Wang, F.; Zhang, Y.; Wang, H.; Liu, Y. In Situ Formation of Gold Nanoparticles Decorated Ti 3 C 2 MXenes Nanoprobe for Highly Sensitive Electrogenerated Chemiluminescence Detection of Exosomes and Their Surface Proteins. Anal. Chem. 2020, 92, 5546–5553. [Google Scholar] [CrossRef]
  108. Gong, L.; Weng, Y.; Zhou, W.; Zhang, K.; Li, W.; Jiang, J.; Zhu, J. In Vivo CT Imaging of Gold Nanoparticle-Labeled Exosomes in a Myocardial Infarction Mouse Model. Ann. Transl. Med. 2021, 9, 504. [Google Scholar] [CrossRef]
  109. You, Q.; Zhuang, L.; Chang, Z.; Ge, M.; Mei, Q.; Yang, L.; Dong, W.-F. Hierarchical Au Nanoarrays Functionalized 2D Ti2CTx MXene Membranes for the Detection of Exosomes Isolated from Human Lung Carcinoma Cells. Biosens. Bioelectron. 2022, 216, 114647. [Google Scholar] [CrossRef]
  110. Cheng, Y.; Xie, Q.; He, M.; Chen, B.; Chen, G.; Yin, X.; Kang, Q.; Xu, Y.; Hu, B. Sensitive Detection of Exosomes by Gold Nanoparticles Labeling Inductively Coupled Plasma Mass Spectrometry Based on Cholesterol Recognition and Rolling Circle Amplification. Anal. Chim. Acta 2022, 1212, 339938. [Google Scholar] [CrossRef] [PubMed]
  111. Bera, D.; Qian, L.; Tseng, T.-K.; Holloway, P.H. Quantum Dots and Their Multimodal Applications: A Review. Materials 2010, 3, 2260–2345. [Google Scholar] [CrossRef] [Green Version]
  112. Foubert, A.; Beloglazova, N.V.; Rajkovic, A.; Sas, B.; Madder, A.; Goryacheva, I.Y.; Saeger, S.D. Bioconjugation of Quantum Dots: Review & Impact on Future Application. TrAC Trends Anal. Chem. 2016, 83, 31–48. [Google Scholar]
  113. Madhankumar, A.B.; Mrowczynski, O.D.; Patel, S.R.; Weston, C.L.; Zacharia, B.E.; Glantz, M.J.; Siedlecki, C.A.; Xu, L.-C.; Connor, J.R. Interleukin-13 Conjugated Quantum Dots for Identification of Glioma Initiating Cells and Their Extracellular Vesicles. Acta Biomater. 2017, 58, 205–213. [Google Scholar] [CrossRef]
  114. Dobhal, G.; Ayupova, D.; Laufersky, G.; Ayed, Z.; Nann, T.; Goreham, R. Cadmium-Free Quantum Dots as Fluorescent Labels for Exosomes. Sensors 2018, 18, 3308. [Google Scholar] [CrossRef] [PubMed]
  115. Bai, Y.; Lu, Y.; Wang, K.; Cheng, Z.; Qu, Y.; Qiu, S.; Zhou, L.; Wu, Z.; Liu, H.; Zhao, J.; et al. Rapid Isolation and Multiplexed Detection of Exosome Tumor Markers Via Queued Beads Combined with Quantum Dots in a Microarray. Nano-Micro Lett. 2019, 11, 59. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  116. Zhang, J.; Zhu, Y.; Shi, J.; Zhang, K.; Zhang, Z.; Zhang, H. Sensitive Signal Amplifying a Diagnostic Biochip Based on a Biomimetic Periodic Nanostructure for Detecting Cancer Exosomes. ACS Appl. Mater. Interfaces 2020, 12, 33473–33482. [Google Scholar] [CrossRef]
  117. Zhang, M.; Vojtech, L.; Ye, Z.; Hladik, F.; Nance, E. Quantum Dot Labeling and Visualization of Extracellular Vesicles. ACS Appl. Nano Mater. 2020, 3, 7211–7222. [Google Scholar] [CrossRef]
  118. Kim, H.-M.; Oh, C.; An, J.; Baek, S.; Bock, S.; Kim, J.; Jung, H.-S.; Song, H.; Kim, J.-W.; Jo, A.; et al. Multi-Quantum Dots-Embedded Silica-Encapsulated Nanoparticle-Based Lateral Flow Assay for Highly Sensitive Exosome Detection. Nanomaterials 2021, 11, 768. [Google Scholar] [CrossRef] [PubMed]
  119. Vinduska, V.; Gallops, C.E.; O’Connor, R.; Wang, Y.; Huang, X. Exosomal Surface Protein Detection with Quantum Dots and Immunomagnetic Capture for Cancer Detection. Nanomaterials 2021, 11, 1853. [Google Scholar] [CrossRef] [PubMed]
  120. Wu, M.; Chen, Z.; Xie, Q.; Xiao, B.; Zhou, G.; Chen, G.; Bian, Z. One-Step Quantification of Salivary Exosomes Based on Combined Aptamer Recognition and Quantum Dot Signal Amplification. Biosens. Bioelectron. 2021, 171, 112733. [Google Scholar] [CrossRef]
  121. Boriachek, K.; Islam, M.N.; Gopalan, V.; Lam, A.K.; Nguyen, N.-T.; Shiddiky, M.J.A. Quantum Dot-Based Sensitive Detection of Disease Specific Exosome in Serum. Analyst 2017, 142, 2211–2219. [Google Scholar] [CrossRef]
  122. Fang, D.; Zhao, D.; Zhang, S.; Huang, Y.; Dai, H.; Lin, Y. Black Phosphorus Quantum Dots Functionalized MXenes as the Enhanced Dual-Mode Probe for Exosomes Sensing. Sens. Actuators B Chem. 2020, 305, 127544. [Google Scholar] [CrossRef]
  123. Pang, X.; Zhang, X.; Gao, K.; Wan, S.; Cui, C.; Li, L.; Si, H.; Tang, B.; Tan, W. Visible Light-Driven Self-Powered Device Based on a Straddling Nano-Heterojunction and Bio-Application for the Quantitation of Exosomal RNA. ACS Nano 2019, 13, 1817–1827. [Google Scholar] [CrossRef] [PubMed]
  124. Dong, D.; Zhu, L.; Hu, J.; Pang, D.-W.; Zhang, Z.-L. Simple and Rapid Extracellular Vesicles Quantification via Membrane Biotinylation Strategy Coupled with Fluorescent Nanospheres-Based Lateral Flow Assay. Talanta 2019, 200, 408–414. [Google Scholar] [CrossRef] [PubMed]
  125. Chen, X.; Lan, J.; Liu, Y.; Li, L.; Yan, L.; Xia, Y.; Wu, F.; Li, C.; Li, S.; Chen, J. A Paper-Supported Aptasensor Based on Upconversion Luminescence Resonance Energy Transfer for the Accessible Determination of Exosomes. Biosens. Bioelectron. 2018, 102, 582–588. [Google Scholar] [CrossRef] [PubMed]
  126. Xia, Y.; Wang, L.; Li, J.; Chen, X.; Lan, J.; Yan, A.; Lei, Y.; Yang, S.; Yang, H.; Chen, J. A Ratiometric Fluorescent Bioprobe Based on Carbon Dots and Acridone Derivate for Signal Amplification Detection Exosomal MicroRNA. Anal. Chem. 2018, 90, 8969–8976. [Google Scholar] [CrossRef]
  127. Wang, Y.; Luo, D.; Fang, Y.; Wu, W.; Wang, Y.; Xia, Y.; Wu, F.; Li, C.; Lan, J.; Chen, J. An Aptasensor Based on Upconversion Nanoparticles as LRET Donors for the Detection of Exosomes. Sens. Actuators B Chem. 2019, 298, 126900. [Google Scholar] [CrossRef]
  128. He, F.; Wang, J.; Yin, B.-C.; Ye, B.-C. Quantification of Exosome Based on a Copper-Mediated Signal Amplification Strategy. Anal. Chem. 2018, 90, 8072–8079. [Google Scholar] [CrossRef]
  129. Huang, G.; Liu, Y.; Wang, D.; Zhu, Y.; Wen, S.; Ruan, J.; Jin, D. Upconversion Nanoparticles for Super-Resolution Quantification of Single Small Extracellular Vesicles. eLight 2022, 2, 20. [Google Scholar] [CrossRef]
  130. Chang, M.; Chang, Y.-J.; Chao, P.Y.; Yu, Q. Exosome Purification Based on PEG-Coated Fe3O4 Nanoparticles. PLoS ONE 2018, 13, e0199438. [Google Scholar] [CrossRef]
  131. Lim, J.; Choi, M.; Lee, H.; Kim, Y.-H.; Han, J.-Y.; Lee, E.S.; Cho, Y. Direct Isolation and Characterization of Circulating Exosomes from Biological Samples Using Magnetic Nanowires. J. Nanobiotechnol. 2019, 17, 1. [Google Scholar] [CrossRef]
  132. Shi, L.; Ba, L.; Xiong, Y.; Peng, G. A Hybridization Chain Reaction Based Assay for Fluorometric Determination of Exosomes Using Magnetic Nanoparticles and Both Aptamers and Antibody as Recognition Elements. Microchim. Acta 2019, 186, 796. [Google Scholar] [CrossRef]
  133. Boriachek, K.; Masud, M.K.; Palma, C.; Phan, H.-P.; Yamauchi, Y.; Hossain, S.A.; Nguyen, N.-T.; Salomon, C.; Shiddiky, M.J.A. Avoiding Pre-Isolation Step in Exosome Analysis: Direct Isolation and Sensitive Detection of Exosomes Using Gold-Loaded Nanoporous Ferric Oxide Nanozymes. Anal. Chem. 2019, 91, 3827–3834. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  134. Wang, Y.; Liu, Z.; Wang, X.; Dai, Y.; Li, X.; Gao, S.; Yu, P.; Lin, Q.; Fan, Z.; Ping, Y.; et al. Rapid and Quantitative Analysis of Exosomes by a Chemiluminescence Immunoassay Using Superparamagnetic Iron Oxide Particles. J. Biomed. Nanotechnol. 2019, 15, 1792–1800. [Google Scholar] [CrossRef]
  135. Nemati, Z.; Zamani Kouhpanji, M.R.; Zhou, F.; Das, R.; Makielski, K.; Um, J.; Phan, M.-H.; Muela, A.; Fdez-Gubieda, M.L.; Franklin, R.R.; et al. Isolation of Cancer-Derived Exosomes Using a Variety of Magnetic Nanostructures: From Fe3O4 Nanoparticles to Ni Nanowires. Nanomaterials 2020, 10, 1662. [Google Scholar] [CrossRef]
  136. Nemati, Z.; Um, J.; Zamani Kouhpanji, M.R.; Zhou, F.; Gage, T.; Shore, D.; Makielski, K.; Donnelly, A.; Alonso, J. Magnetic Isolation of Cancer-Derived Exosomes Using Fe/Au Magnetic Nanowires. ACS Appl. Nano Mater. 2020, 3, 2058–2069. [Google Scholar] [CrossRef]
  137. Chen, H.; Luo, D.; Shang, B.; Cao, J.; Wei, J.; Chen, Q.; Chen, J. Immunoassay-Type Biosensor Based on Magnetic Nanoparticle Capture and the Fluorescence Signal Formed by Horseradish Peroxidase Catalysis for Tumor-Related Exosome Determination. Microchim. Acta 2020, 187, 282. [Google Scholar] [CrossRef] [PubMed]
  138. Li, B.; Pan, W.; Liu, C.; Guo, J.; Shen, J.; Feng, J.; Luo, T.; Situ, B.; Zhang, Y.; An, T.; et al. Homogenous Magneto-Fluorescent Nanosensor for Tumor-Derived Exosome Isolation and Analysis. ACS Sens. 2020, 5, 2052–2060. [Google Scholar] [CrossRef]
  139. Koo, K.M.; Soda, N.; Shiddiky, M.J.A. Magnetic Nanomaterial–Based Electrochemical Biosensors for the Detection of Diverse Circulating Cancer Biomarkers. Curr. Opin. Electrochem. 2021, 25, 100645. [Google Scholar] [CrossRef]
  140. Yang, W.; Yu, Y.; Shou, X.; Zhang, D.; Liang, G.; Zhao, Y. Hedgehog-Inspired Magnetic Nanoparticles for Effectively Capturing and Detecting Exosomes. NPG Asia Mater. 2021, 13, 78. [Google Scholar] [CrossRef]
  141. Zhang, C.; Pan, Y.; Zhao, Y.; Wang, P.; Zhang, L.; Zhang, W. Design and Application of Hydrophilic Bimetallic Metal-Organic Framework Magnetic Nanoparticles for Rapid Capture of Exosomes. Analy. Chim. Acta 2021, 1186, 339099. [Google Scholar] [CrossRef]
  142. Farhana, F.Z.; Umer, M.; Saeed, A.; Pannu, A.S.; Shahbazi, M.; Jabur, A.; Nam, H.J.; Ostrikov, K.; Sonar, P.; Firoz, S.H.; et al. Isolation and Detection of Exosomes Using Fe 2 O 3 Nanoparticles. ACS Appl. Nano Mater. 2021, 4, 1175–1186. [Google Scholar] [CrossRef]
  143. Zhu, N.; Zhang, Y.; Cheng, J.; Mao, Y.; Kang, K.; Li, G.; Yi, Q.; Wu, Y. Immuno-Affinitive Supramolecular Magnetic Nanoparticles Incorporating Cucurbit[8]Uril-Mediated Ternary Host-Guest Complexation Structures for High-Efficient Small Extracellular Vesicle Enrichment. J. Colloid Interface Sci. 2022, 611, 462–471. [Google Scholar] [CrossRef]
  144. Shao, J.; Chung, L.; Balaj, A.; Charest, D.D.; Bigner, B.S.; Carter, F.H.; Hochberg, X.O.; Breakefield, R.; Weissleder, H.; Lee, H. Protein Typing of Circulating Microvesicles Allows Real-Time Monitoring of Glioblastoma Therapy. Nat. Med. 2012, 18, 1835–1840. [Google Scholar] [CrossRef]
  145. Lee, H.; Sun, E.; Ham, D.; Weissleder, R. Chip–NMR Biosensor for Detection and Molecular Analysis of Cells. Nat. Med. 2008, 14, 869–874. [Google Scholar] [CrossRef] [Green Version]
  146. Issadore, D.; Min, C.; Liong, M.; Chung, J.; Weissleder, R.; Lee, H. Miniature Magnetic Resonance System for Point-of-Care Diagnostics. Lab Chip 2011, 11, 2282. [Google Scholar] [CrossRef] [PubMed]
  147. Haun, J.B.; Castro, C.M.; Wang, R.; Peterson, V.M.; Marinelli, B.S.; Lee, H.; Weissleder, R. Micro-NMR for Rapid Molecular Analysis of Human Tumor Samples. Sci. Transl. Med. 2011, 3, 7lra16. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  148. Rho, J.; Chung, J.; Im, H.; Liong, M.; Shao, H.; Castro, C.M.; Weissleder, R.; Lee, H. Magnetic Nanosensor for Detection and Profiling of Erythrocyte-Derived Microvesicles. ACS Nano 2013, 7, 11227–11233. [Google Scholar] [CrossRef] [Green Version]
  149. Chen, J.; Xu, Y.; Lu, Y.; Xing, W. Isolation and Visible Detection of Tumor-Derived Exosomes from Plasma. Anal. Chem. 2018, 90, 14207–14215. [Google Scholar] [CrossRef] [PubMed]
  150. Wang, B.; Moyano, A.; Duque, J.M.; Sánchez, L.; García-Santos, G.; Flórez, L.J.G.; Serrano-Pertierra, E.; Blanco-López, M.d.C. Nanozyme-Based Lateral Flow Immunoassay (LFIA) for Extracellular Vesicle Detection. Biosensors 2022, 12, 490. [Google Scholar] [CrossRef] [PubMed]
  151. James, S.L. Metal-Organic Frameworks. Chem. Soc. Rev. 2003, 32, 276–288. [Google Scholar] [CrossRef]
  152. Zhou, H.-C.; Long, J.R.; Yaghi, O.M. Introduction to Metal–Organic Frameworks. Chem. Rev. 2012, 112, 673–674. [Google Scholar] [CrossRef]
  153. Li, Y.; Wen, G.; Li, J.; Li, Q.; Zhang, H.; Tao, B.; Zhang, J. Synthesis and Shaping of Metal-Organic Frameworks: A Review. Chem. Commun. 2022, 58, 11488–11506. [Google Scholar] [CrossRef] [PubMed]
  154. Furukawa, H.; Cordova, K.E.; O’Keeffe, M.; Yaghi, O.M. The Chemistry and Applications of Metal-Organic Frameworks. Science 2013, 341, 1230444. [Google Scholar] [CrossRef] [PubMed]
  155. Sun, Z.; Wang, L.; Wu, S.; Pan, Y.; Dong, Y.; Zhu, S.; Yang, J.; Yin, Y.; Li, G. An Electrochemical Biosensor Designed by Using Zr-Based Metal–Organic Frameworks for the Detection of Glioblastoma-Derived Exosomes with Practical Application. Anal. Chem. 2020, 92, 3819–3826. [Google Scholar] [CrossRef] [PubMed]
  156. Sun, Y.; Jin, H.; Jiang, X.; Gui, R. Assembly of Black Phosphorus Nanosheets and MOF to Form Functional Hybrid Thin-Film for Precise Protein Capture, Dual-Signal and Intrinsic Self-Calibration Sensing of Specific Cancer-Derived Exosomes. Anal. Chem. 2020, 92, 2866–2875. [Google Scholar] [CrossRef] [PubMed]
  157. Liu, X.; Gao, X.; Yang, L.; Zhao, Y.; Li, F. Metal–Organic Framework-Functionalized Paper-Based Electrochemical Biosensor for Ultrasensitive Exosome Assay. Anal. Chem. 2021, 93, 11792–11799. [Google Scholar] [CrossRef]
  158. Cao, Y.; Wang, Y.; Yu, X.; Jiang, X.; Li, G.; Zhao, J. Identification of Programmed Death Ligand-1 Positive Exosomes in Breast Cancer Based on DNA Amplification-Responsive Metal-Organic Frameworks. Biosens. Bioelectron. 2020, 166, 112452. [Google Scholar] [CrossRef] [PubMed]
  159. Wang, F.; Gui, Y.; Liu, W.; Li, C.; Yang, Y. Precise Molecular Profiling of Circulating Exosomes Using a Metal–Organic Framework-Based Sensing Interface and an Enzyme-Based Electrochemical Logic Platform. Anal. Chem. 2022, 94, 875–883. [Google Scholar] [CrossRef]
  160. Zhang, Y.; Zhu, H.; Ying, Z.; Gao, X.; Chen, W.; Zhan, Y.; Feng, L.; Liu, C.C.; Dai, Y. Design and Application of Metal Organic Framework ZIF-90-ZnO-MoS 2 Nanohybrid for an Integrated Electrochemical Liquid Biopsy. Nano Lett. 2022, 22, 6833–6840. [Google Scholar] [CrossRef]
  161. Zhang, L.; Wang, H.; Zhao, G.; Li, N.; Wang, X.; Li, Y.; Jia, Y.; Qiao, X. Anti-Tim4 Grafting Strongly Hydrophilic Metal–Organic Frameworks Immunoaffinity Flake for High-Efficiency Capture and Separation of Exosomes. Anal. Chem. 2021, 93, 6534–6543. [Google Scholar] [CrossRef]
  162. Zhand, S.; Xiao, K.; Razavi Bazaz, S.; Zhu, Y.; Bordhan, P.; Jin, D.; Warkiani, M.E. Improving Capture Efficiency of Human Cancer Cell Derived Exosomes with Nanostructured Metal Organic Framework Functionalized Beads. Appl. Mater. Today 2021, 23, 100994. [Google Scholar] [CrossRef]
  163. Zheng, H.; Guan, S.; Wang, X.; Zhao, J.; Gao, M.; Zhang, X. Deconstruction of Heterogeneity of Size-Dependent Exosome Subpopulations from Human Urine by Profiling N-Glycoproteomics and Phosphoproteomics Simultaneously. Anal. Chem. 2020, 92, 9239–9246. [Google Scholar] [CrossRef] [PubMed]
  164. Geng, K.; He, T.; Liu, R.; Dalapati, S.; Tan, K.T.; Li, Z.; Tao, S.; Gong, Y.; Jiang, Q.; Jiang, D. Covalent Organic Frameworks: Design, Synthesis, and Functions. Chem. Rev. 2020, 120, 8814–8933. [Google Scholar] [CrossRef] [PubMed]
  165. Wang, M.; Pan, Y.; Wu, S.; Sun, Z.; Wang, L.; Yang, J.; Yin, Y.; Li, G. Detection of Colorectal Cancer-Derived Exosomes Based on Covalent Organic Frameworks. Biosens. Bioelectron. 2020, 169, 112638. [Google Scholar] [CrossRef]
  166. Iijima, S. Helical Microtubules of Graphitic Carbon. Nature 1991, 354, 56–58. [Google Scholar] [CrossRef]
  167. Oberlin, A.; Endo, M.; Koyama, T. Filamentous Growth of Carbon through Benzene Decomposition. J. Cryst. Growth 1976, 32, 335–349. [Google Scholar] [CrossRef]
  168. Sharma, P.; Mehra, N.K.; Jain, K.; Jain, N. Biomedical Applications of Carbon Nanotubes: A Critical Review. Curr. Drug Deliv. 2016, 13, 796–817. [Google Scholar] [CrossRef]
  169. Rajabathar, J.R.; Periyasami, G.; Alanazi, A.M.; Govindasamy, M.; Arunachalam, P. Review on Carbon Nanotube Varieties for Healthcare Application: Effect of Preparation Methods and Mechanism Insight. Processes 2020, 8, 1654. [Google Scholar] [CrossRef]
  170. Rathinavel, S.; Priyadharshini, K.; Panda, D. A Review on Carbon Nanotube: An Overview of Synthesis, Properties, Functionalization, Characterization, and the Application. Mater. Sci. Eng. B 2021, 268, 115095. [Google Scholar] [CrossRef]
  171. Shoukat, R.; Khan, M.I. Carbon Nanotubes: A Review on Properties, Synthesis Methods and Applications in Micro and Nanotechnology. Microsyst. Technol. 2021, 27, 4183–4192. [Google Scholar] [CrossRef]
  172. Yeh, Y.-T.; Zhou, Y.; Zou, D.; Liu, H.; Yu, H.; Lu, H.; Swaminathan, V.; Mao, Y.; Terrones, M. Rapid Size-Based Isolation of Extracellular Vesicles by Three-Dimensional Carbon Nanotube Arrays. ACS Appl. Mater. Interfaces 2020, 12, 13134–13139. [Google Scholar] [CrossRef] [PubMed]
  173. Xia, Y.; Liu, M.; Wang, L.; Yan, A.; He, W.; Chen, M.; Lan, J.; Xu, J.; Guan, L.; Chen, J. A Visible and Colorimetric Aptasensor Based on DNA-Capped Single-Walled Carbon Nanotubes for Detection of Exosomes. Biosens. Bioelectron. 2017, 92, 8–15. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  174. Tayebi, M.; Tavakkoli Yaraki, M.; Yang, H.Y.; Ai, Y. A MoS2 –MWCNT Based Fluorometric Nanosensor for Exosome Detection and Quantification. Nanoscale Adv. 2019, 1, 2866–2872. [Google Scholar] [CrossRef]
  175. Li, T.; Liang, Y.; Li, J.; Yu, Y.; Xiao, M.-M.; Ni, W.; Zhang, Z.; Zhang, G.-J. Carbon Nanotube Field-Effect Transistor Biosensor for Ultrasensitive and Label-Free Detection of Breast Cancer Exosomal MiRNA21. Anal. Chem. 2021, 93, 15501–15507. [Google Scholar] [CrossRef] [PubMed]
  176. Si, F.; Liu, Z.; Li, J.; Yang, H.; Liu, Y.; Kong, J. Sensitive Electrochemical Detection of A549 Exosomes Based on DNA/Ferrocene-Modified Single-Walled Carbon Nanotube Complex. Analy. Biochem. 2023, 660, 114971. [Google Scholar] [CrossRef]
  177. Sahraei, N.; Mazloum-Ardakani, M.; Khoshroo, A.; Hoseynidokht, F.; Mohiti, J.; Moradi, A. Electrochemical System Designed on a Paper Platform as a Label-Free Immunosensor for Cancer Derived Exosomes Based on a Mesoporous Carbon Foam- Ternary Nanocomposite. J. Electroanaly. Chem. 2022, 920, 116590. [Google Scholar] [CrossRef]
  178. Hashkavayi, A.B.; Cha, B.S.; Lee, E.S.; Park, K.S. Dual Rolling Circle Amplification-Enabled Ultrasensitive Multiplex Detection of Exosome Biomarkers Using Electrochemical Aptasensors. Anal. Chim. Acta 2022, 1205, 339762. [Google Scholar] [CrossRef]
  179. Zhao, Z.; Sun, Y.; Dong, F. Graphitic Carbon Nitride Based Nanocomposites: A Review. Nanoscale 2015, 7, 15–37. [Google Scholar] [CrossRef]
  180. Ahmad, R.; Tripathy, N.; Khosla, A.; Khan, M.; Mishra, P.; Ansari, W.A.; Syed, M.A.; Hahn, Y.-B. Review—Recent Advances in Nanostructured Graphitic Carbon Nitride as a Sensing Material for Heavy Metal Ions. J. Electrochem. Soc. 2020, 167, 037519. [Google Scholar] [CrossRef]
  181. Pourmadadi, M.; Rajabzadeh-Khosroshahi, M.; Saeidi Tabar, F.; Ajalli, N.; Samadi, A.; Yazdani, M.; Yazdian, F.; Rahdar, A.; Díez-Pascual, A.M. Two-Dimensional Graphitic Carbon Nitride (g-C3N4) Nanosheets and Their Derivatives for Diagnosis and Detection Applications. J. Funct. Biomater. 2022, 13, 204. [Google Scholar] [CrossRef]
  182. Wang, Y.-M.; Liu, J.-W.; Adkins, G.B.; Shen, W.; Trinh, M.P.; Duan, L.-Y.; Jiang, J.-H.; Zhong, W. Enhancement of the Intrinsic Peroxidase-Like Activity of Graphitic Carbon Nitride Nanosheets by SsDNAs and Its Application for Detection of Exosomes. Anal. Chem. 2017, 89, 12327–12333. [Google Scholar] [CrossRef] [PubMed]
  183. Allen, M.J.; Tung, V.C.; Kaner, R.B. Honeycomb Carbon: A Review of Graphene. Chem. Rev. 2010, 110, 132–145. [Google Scholar] [CrossRef] [PubMed]
  184. Ghuge, A.D.; Shirode, A.R.; Kadam, V.J. Graphene: A Comprehensive Review. Curr. Drug. Targets. 2017, 18, 724–733. [Google Scholar] [CrossRef] [PubMed]
  185. Chen, S.-L.; Chen, C.-Y.; Hsieh, J.C.-H.; Yu, Z.-Y.; Cheng, S.-J.; Hsieh, K.Y.; Yang, J.-W.; Kumar, P.V.; Lin, S.-F.; Chen, G.-Y. Graphene Oxide-Based Biosensors for Liquid Biopsies in Cancer Diagnosis. Nanomaterials 2019, 9, 1725. [Google Scholar] [CrossRef] [Green Version]
  186. Kwong Hong Tsang, D.; Lieberthal, T.J.; Watts, C.; Dunlop, I.E.; Ramadan, S.; del Rio Hernandez, A.E.; Klein, N. Chemically Functionalised Graphene FET Biosensor for the Label-Free Sensing of Exosomes. Sci. Rep. 2019, 9, 13946. [Google Scholar] [CrossRef] [Green Version]
  187. Yu, Y.; Li, Y.-T.; Jin, D.; Yang, F.; Wu, D.; Xiao, M.-M.; Zhang, H.; Zhang, Z.-Y.; Zhang, G.-J. Electrical and Label-Free Quantification of Exosomes with a Reduced Graphene Oxide Field Effect Transistor Biosensor. Anal. Chem. 2019, 91, 10679–10686. [Google Scholar] [CrossRef]
  188. Wu, D.; Zhang, H.; Jin, D.; Yu, Y.; Pang, D.-W.; Xiao, M.-M.; Zhang, Z.-L.; Zhang, Z.-Y.; Zhang, G.-J. Microvesicle Detection by a Reduced Graphene Oxide Field-Effect Transistor Biosensor Based on a Membrane Biotinylation Strategy. Analyst 2019, 144, 6055–6063. [Google Scholar] [CrossRef]
  189. Feng, D.; Ren, M.; Miao, Y.; Liao, Z.; Zhang, T.; Chen, S.; Ye, K.; Zhang, P.; Ma, X.; Ni, J.; et al. Dual Selective Sensor for Exosomes in Serum Using Magnetic Imprinted Polymer Isolation Sandwiched with Aptamer/Graphene Oxide Based FRET Fluorescent Ignition. Biosens. Bioelectron. 2022, 207, 114112. [Google Scholar] [CrossRef]
  190. Huang, J.; Yan, H.; Ma, M.; Tian, N.; Ni, H.; Xia, M.; Pei, K.; Ye, P. Hydroxylated Graphene Porous Membrane-Based Biosensor for Exosome Isolation and Detection. ACS Appl. Nano Mater. 2022, 5, 6115–6124. [Google Scholar] [CrossRef]
  191. Zhang, P.; He, M.; Zeng, Y. Ultrasensitive Microfluidic Analysis of Circulating Exosomes Using a Nanostructured Graphene Oxide/Polydopamine Coating. Lab Chip 2016, 16, 3033–3042. [Google Scholar] [CrossRef] [Green Version]
  192. He, N.; Thippabhotla, S.; Zhong, C.; Greenberg, Z.; Xu, L.; Pessetto, Z.; Godwin, A.K.; Zeng, Y.; He, M. Nano Pom-Poms Prepared Exosomes Enable Highly Specific Cancer Biomarker Detection. Commun. Biol. 2022, 5, 660. [Google Scholar] [CrossRef] [PubMed]
  193. Huang, W.; Yu, Y.; Yang, C.; Zhang, X.; Shang, L.; Zu, Y.; Shi, K. Aptamer Decorated Magnetic Graphene Oxide Nanoparticles for Effective Capture of Exosomes. Chem. Eng. J. 2022, 431, 133849. [Google Scholar] [CrossRef]
  194. Lim, J.; Choi, M.; Lee, H.; Han, J.-Y.; Cho, Y. A Novel Multifunctional Nanowire Platform for Highly Efficient Isolation and Analysis of Circulating Tumor-Specific Markers. Front. Chem. 2019, 6, 6644. [Google Scholar] [CrossRef]
  195. Zheng, J.; Li, N.; Li, C.; Wang, X.; Liu, Y.; Mao, G.; Ji, X.; He, Z. A Nonenzmmatic DNA Nanomachine for Biomolecular Detection by Target Recycling of Hairpin DNA Cascade Amplification. Biosens. Bioelectron. 2018, 107, 40–46. [Google Scholar] [CrossRef] [PubMed]
  196. Zhang, J.; Wang, L.-L.; Hou, M.-F.; Xia, Y.-K.; He, W.-H.; Yan, A.; Weng, Y.-P.; Zeng, L.-P.; Chen, J.-H. A Ratiometric Electrochemical Biosensor for the Exosomal MicroRNAs Detection Based on Bipedal DNA Walkers Propelled by Locked Nucleic Acid Modified Toehold Mediate Strand Displacement Reaction. Biosens. Bioelectron. 2018, 102, 33–40. [Google Scholar] [CrossRef]
  197. Huang, R.; He, L.; Xia, Y.; Xu, H.; Liu, C.; Xie, H.; Wang, S.; Peng, L.; Liu, Y.; Liu, Y.; et al. A Sensitive Aptasensor Based on a Hemin/G-Quadruplex-Assisted Signal Amplification Strategy for Electrochemical Detection of Gastric Cancer Exosomes. Small 2019, 15, 1900735. [Google Scholar] [CrossRef] [PubMed]
  198. Dong, H.; Chen, H.; Jiang, J.; Zhang, H.; Cai, C.; Shen, Q. Highly Sensitive Electrochemical Detection of Tumor Exosomes Based on Aptamer Recognition-Induced Multi-DNA Release and Cyclic Enzymatic Amplification. Anal. Chem. 2018, 90, 4507–4513. [Google Scholar] [CrossRef]
  199. Zhao, L.; Sun, R.; He, P.; Zhang, X. Ultrasensitive Detection of Exosomes by Target-Triggered Three-Dimensional DNA Walking Machine and Exonuclease III-Assisted Electrochemical Ratiometric Biosensing. Anal. Chem. 2019, 91, 14773–14779. [Google Scholar] [CrossRef]
  200. Cao, Y.; Li, L.; Han, B.; Wang, Y.; Dai, Y.; Zhao, J. A Catalytic Molecule Machine-Driven Biosensing Method for Amplified Electrochemical Detection of Exosomes. Biosens. Bioelectron. 2019, 141, 111397. [Google Scholar] [CrossRef]
  201. He, D.; Ho, S.-L.; Chan, H.-N.; Wang, H.; Hai, L.; He, X.; Wang, K.; Li, H.-W. Molecular-Recognition-Based DNA Nanodevices for Enhancing the Direct Visualization and Quantification of Single Vesicles of Tumor Exosomes in Plasma Microsamples. Anal. Chem. 2019, 91, 2768–2775. [Google Scholar] [CrossRef]
  202. Jiang, Q.; Liu, Y.; Wang, L.; Adkins, G.B.; Zhong, W. Rapid Enrichment and Detection of Extracellular Vesicles Enabled by CuS-Enclosed Microgels. Anal. Chem. 2019, 91, 15951–15958. [Google Scholar] [CrossRef] [PubMed]
  203. Liu, C.; Kannisto, E.; Yu, G.; Yang, Y.; Reid, M.E.; Patnaik, S.K.; Wu, Y. Non-Invasive Detection of Exosomal MicroRNAs via Tethered Cationic Lipoplex Nanoparticles (TCLN) Biochip for Lung Cancer Early Detection. Front. Genet. 2020, 11, 258. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  204. Kwon, Y.; Park, J. Methods to Analyze Extracellular Vesicles at Single Particle Level. Micro Nano Syst. Lett. 2022, 10, 14. [Google Scholar] [CrossRef]
Figure 1. Overview of the application of nanomaterials and detection methods for extracellular vesicles. Abbreviation: NPs—nanoparticles, SPR—surface plasmon resonance, SERS—surface enhanced Raman scattering, µNMR: micro-nuclear magnetic resonance.
Figure 1. Overview of the application of nanomaterials and detection methods for extracellular vesicles. Abbreviation: NPs—nanoparticles, SPR—surface plasmon resonance, SERS—surface enhanced Raman scattering, µNMR: micro-nuclear magnetic resonance.
Nanomaterials 13 00524 g001
Figure 2. AuNP−amplified iNPS assay for the detection of intravesicular and transmembrane proteins. (a) Schematic of the methodology for EV protein detection. EVs are lysed to release proteins. Targeted proteins are captured on the iNPS chip via affinity ligands and detected by antibodies on AuNPs. (b) Scanning electron microscope image showing AuNPs on the iNPS sensor. (c) Finite difference time−domain (FDTD) simulation showing the concentration of the electrical fields on AuNPs. (d) Comparison of the signals with and without AuNPs on the iNPS sensor. (e) Protein profiling of EVs derived from ovarian cells. (f) Drug (HSP90 inhibitor) response monitoring of OV90 cells by EV protein detection with iNPS. The fold change is the protein level changes monitored by the iNPS spectral shifts after drug treatment. Reprinted with permission from [62]. Copyright (2018) American Chemical Society.
Figure 2. AuNP−amplified iNPS assay for the detection of intravesicular and transmembrane proteins. (a) Schematic of the methodology for EV protein detection. EVs are lysed to release proteins. Targeted proteins are captured on the iNPS chip via affinity ligands and detected by antibodies on AuNPs. (b) Scanning electron microscope image showing AuNPs on the iNPS sensor. (c) Finite difference time−domain (FDTD) simulation showing the concentration of the electrical fields on AuNPs. (d) Comparison of the signals with and without AuNPs on the iNPS sensor. (e) Protein profiling of EVs derived from ovarian cells. (f) Drug (HSP90 inhibitor) response monitoring of OV90 cells by EV protein detection with iNPS. The fold change is the protein level changes monitored by the iNPS spectral shifts after drug treatment. Reprinted with permission from [62]. Copyright (2018) American Chemical Society.
Nanomaterials 13 00524 g002
Figure 3. DISVT for surface protein detection of single EVs. (a) Schematic of the DISVT principle showing exosome capture with CD81 antibodies, membrane labeling with lipophilic Chol–PEG−Cy5, and surface protein labeling with antibody-conjugated AuNPs. (b) Optical properties of AuNPs and Chol–PEG−Cy5. (c) Fluorescence image of CD81−captured plasma EVs from a stage III HER2-positive breast cancer patient after dual labeling with Chol–PEG−Cy5 and HER2/AuNPs. (d) Dark field image of (c). (e) Superimposed image of (c) and (d) showing AuNP-bound EVs (overlapped red and yellow labels) and AuNP−free EVs (red labels only). (f) EV population density histogram showing the AuNP−bound EVs (blue peak) and AuNP−free EVs (orange peak). (g) EV population density histogram of EVs from a stage I HER2−positive breast cancer patient. (h) EV population density histogram of EVs from a stage III HER2−positive breast cancer patient. (i) Box plot showing the diagnostic potential of DISVT for early detection of HER2−positive breast cancer (n = 10 for each group). Reprinted with permission from [68]. Copyright (2023) American Chemical Society.
Figure 3. DISVT for surface protein detection of single EVs. (a) Schematic of the DISVT principle showing exosome capture with CD81 antibodies, membrane labeling with lipophilic Chol–PEG−Cy5, and surface protein labeling with antibody-conjugated AuNPs. (b) Optical properties of AuNPs and Chol–PEG−Cy5. (c) Fluorescence image of CD81−captured plasma EVs from a stage III HER2-positive breast cancer patient after dual labeling with Chol–PEG−Cy5 and HER2/AuNPs. (d) Dark field image of (c). (e) Superimposed image of (c) and (d) showing AuNP-bound EVs (overlapped red and yellow labels) and AuNP−free EVs (red labels only). (f) EV population density histogram showing the AuNP−bound EVs (blue peak) and AuNP−free EVs (orange peak). (g) EV population density histogram of EVs from a stage I HER2−positive breast cancer patient. (h) EV population density histogram of EVs from a stage III HER2−positive breast cancer patient. (i) Box plot showing the diagnostic potential of DISVT for early detection of HER2−positive breast cancer (n = 10 for each group). Reprinted with permission from [68]. Copyright (2023) American Chemical Society.
Nanomaterials 13 00524 g003
Figure 4. SERS—based molecular detection of exosomes. (a) Exosome classification through SERS detection of exosomes from normal and lung cancer cells. Left: Schematic of SERS detection of exosomes. Middle: SERS spectra of exosomes from different origins and control using PBS. Right: Principle component scatter plot showing clusters of exosomes from different origins. Reprinted with permission from [71]. Copyright (2017) American Chemical Society. (b) Individual molecular detection of exosome-like vesicles by label-free SERS spectroscopy. Left: Schematic of single EV detection. Each spectrum was recorded from one vesicle to another by moving the laser to a different spatial location of 1, 2, 3, etc. Middle: Representative SERS spectrum of EVs derived from B16F10 melanoma cells. Right: Representative SERS spectrum of EVs derived from red blood cells. Reprinted with permission from [75]. Copyright 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. (c) Molecular detection and analysis of exosomes with SERS AuNRs. Left: Schematic of the detection principle showing exosome capture with target-specific antibodies on an Au array device and exosome detection with SERS AuNRs via electrostatic interactions with exosome membranes. Middle: Detection of different surface protein markers on exosomes derived from SKBR3 breast cancer cells. Right: Detection of HER2-breast cancer by quantification of HER2-positive plasma exosomes. Cited from ref. [34].
Figure 4. SERS—based molecular detection of exosomes. (a) Exosome classification through SERS detection of exosomes from normal and lung cancer cells. Left: Schematic of SERS detection of exosomes. Middle: SERS spectra of exosomes from different origins and control using PBS. Right: Principle component scatter plot showing clusters of exosomes from different origins. Reprinted with permission from [71]. Copyright (2017) American Chemical Society. (b) Individual molecular detection of exosome-like vesicles by label-free SERS spectroscopy. Left: Schematic of single EV detection. Each spectrum was recorded from one vesicle to another by moving the laser to a different spatial location of 1, 2, 3, etc. Middle: Representative SERS spectrum of EVs derived from B16F10 melanoma cells. Right: Representative SERS spectrum of EVs derived from red blood cells. Reprinted with permission from [75]. Copyright 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. (c) Molecular detection and analysis of exosomes with SERS AuNRs. Left: Schematic of the detection principle showing exosome capture with target-specific antibodies on an Au array device and exosome detection with SERS AuNRs via electrostatic interactions with exosome membranes. Middle: Detection of different surface protein markers on exosomes derived from SKBR3 breast cancer cells. Right: Detection of HER2-breast cancer by quantification of HER2-positive plasma exosomes. Cited from ref. [34].
Nanomaterials 13 00524 g004
Figure 5. Fluorescent detection of exosomes using QDs. (a) Isolation and multiplexed detection of exosomal tumor markers using QDs and magnetic beads in a microarray chip. Left: Schematic of the methodology showing exosome isolation with single magnetic bead trapped in the microfluidic pillars and multiplexed detection with multicolor QDs. Right: Fluorescence images of exosomes derived from different cell lines using three different target-specific QDs: QD525, QD585, and QD625. Cited from ref. [115]. (b) EV labeling and visualization with QDs. Left: Schematic of EV labeling with QDs. Middle: Photostability of QDs in comparison to Dil dye. Right: Fluorescence imaging showing the distribution of QD-labeled EVs (red) on lection stained BV-2 cells (green). Reprinted with permission from [117]. Copyright (2020) American Chemical Society. (c) Detection of breast cancer with QDs combined with immunomagnetic separation. Left: Schematic of the immunomagnetic isolation with magnetic beads and fluorescence detection of surface protein markers by QD655. Right: Fluorescence spectrum of exosomes from HER2-positive breast cancer patients and healthy donors after labeling with HER2-targeted QDs showing diagnosis potential of QDs for detection of HER2-positive breast cancer. Cited from ref. [119].
Figure 5. Fluorescent detection of exosomes using QDs. (a) Isolation and multiplexed detection of exosomal tumor markers using QDs and magnetic beads in a microarray chip. Left: Schematic of the methodology showing exosome isolation with single magnetic bead trapped in the microfluidic pillars and multiplexed detection with multicolor QDs. Right: Fluorescence images of exosomes derived from different cell lines using three different target-specific QDs: QD525, QD585, and QD625. Cited from ref. [115]. (b) EV labeling and visualization with QDs. Left: Schematic of EV labeling with QDs. Middle: Photostability of QDs in comparison to Dil dye. Right: Fluorescence imaging showing the distribution of QD-labeled EVs (red) on lection stained BV-2 cells (green). Reprinted with permission from [117]. Copyright (2020) American Chemical Society. (c) Detection of breast cancer with QDs combined with immunomagnetic separation. Left: Schematic of the immunomagnetic isolation with magnetic beads and fluorescence detection of surface protein markers by QD655. Right: Fluorescence spectrum of exosomes from HER2-positive breast cancer patients and healthy donors after labeling with HER2-targeted QDs showing diagnosis potential of QDs for detection of HER2-positive breast cancer. Cited from ref. [119].
Nanomaterials 13 00524 g005
Figure 6. Magnetic nanosensor for the detection and profiling of microvesicles derived from red blood cells (RBC). (a) Schematic of microvesicle labeling with MNPs. (b) Schematic of the µNMR system showing the derived sensor coupled with membrane filter for microvesicle separation. (c) Relaxation rate change (ΔR2CD235a) versus the number of microvesicles using CD235a targeted MNPs. (d) ΔR2CD235a at different days of red blood cell storage showing stable vesicle expression of CD235a. (e) Relative changes in the expression levels of CD44, CD47, and CD55 during storage of red blood cells showing little changes in the expression levels of these proteins on microvesicles. * p > 0.48; ** p > 0.15; *** p > 0.17. (f) Microvesicle concentration over storage time showing the increase of the amount of microvesicles with storage time. Reprinted with permission from [148]. Copyright (2013) American Chemical Society.
Figure 6. Magnetic nanosensor for the detection and profiling of microvesicles derived from red blood cells (RBC). (a) Schematic of microvesicle labeling with MNPs. (b) Schematic of the µNMR system showing the derived sensor coupled with membrane filter for microvesicle separation. (c) Relaxation rate change (ΔR2CD235a) versus the number of microvesicles using CD235a targeted MNPs. (d) ΔR2CD235a at different days of red blood cell storage showing stable vesicle expression of CD235a. (e) Relative changes in the expression levels of CD44, CD47, and CD55 during storage of red blood cells showing little changes in the expression levels of these proteins on microvesicles. * p > 0.48; ** p > 0.15; *** p > 0.17. (f) Microvesicle concentration over storage time showing the increase of the amount of microvesicles with storage time. Reprinted with permission from [148]. Copyright (2013) American Chemical Society.
Nanomaterials 13 00524 g006
Figure 7. Detection of Glioblastoma-derived exosomes with Zr−based MOFs. (a) Schematic of the preparation of MB@UiO−66 nanoprobes. (b) Scanning microscope image of MB@UiO−66 nanoprobes. (c) Schematic of the principle of electrochemical detection of exosomes using MB@UiO−66 nanoprobes. (d) SWV recorded with different concentrations of exosomes. (e) Scattered dot plots of exosomes from different human subjects. HS: healthy subjects. GBM: Glioblastoma. GBM−AS: GMB after surgery. ***: p < 0.0001. **: p < 0.001. Error bars represent the standard deviation of three independent experiments. Reprinted with permission from [155]. Copyright (2020) American Chemical Society.
Figure 7. Detection of Glioblastoma-derived exosomes with Zr−based MOFs. (a) Schematic of the preparation of MB@UiO−66 nanoprobes. (b) Scanning microscope image of MB@UiO−66 nanoprobes. (c) Schematic of the principle of electrochemical detection of exosomes using MB@UiO−66 nanoprobes. (d) SWV recorded with different concentrations of exosomes. (e) Scattered dot plots of exosomes from different human subjects. HS: healthy subjects. GBM: Glioblastoma. GBM−AS: GMB after surgery. ***: p < 0.0001. **: p < 0.001. Error bars represent the standard deviation of three independent experiments. Reprinted with permission from [155]. Copyright (2020) American Chemical Society.
Nanomaterials 13 00524 g007
Table 1. Summary of the major nanomaterials for molecular detection and analysis of extracellular vesicles.
Table 1. Summary of the major nanomaterials for molecular detection and analysis of extracellular vesicles.
Type of NanomaterialsMaterial Composition Detection
Mechanism
Lowest LOD Clinical TestReference
Plasmonic NPs
and nanopatterns
AuNPs, nanostar,
nanoisland, nanowhole array
SPR3000 exosomesOvarian, prostate, and lung cancers[32,62,63,64,65,66,67]
AuNPs, AuNRsLight scatteringSingle vesiclePancreatic and breast cancers[33,68]
AuNPs, AuNRs, Ag nanograins, Ag nanocube, Au-Ag core-shell NPsSERSSingle vesicleBreast and
pancreatic cancers
[34,69,70,71,72,73,74,75,76,77]
AuNPsColorimetric108 exosomes/mLLiver cancer[81,82,83,84]
AgNPs, CuNPsElectrochemical50 exosomes/sensorProstate cancer[99]
AuNPsAcoustic, mechanic, CT, fluorescence1000 exosomes/mLBreast and
lung cancers
[100,101,102,103,104,105,106,107,108,109,110]
Fluorescence NPsQDsFluorescence105 exosomes/mLBreast, colorectal, lung, and pancreatic cancers [113,114,115,116,117,118,119,120]
Electrochemical105 exosomes/mLN/A[121,122,123]
UCNPs and other carbon-base NPsFluorescence Single vesicleN/A[124,125,126,127,128,129]
Magnetic NPsIO NPsµNMR104 microvesiclesGlioblastoma[144,148]
IO NPsColorimetric and
others
3.6 × 109 exosomes/mLProstate cancer[149,150]
Organic framework NPsMOFsElectrochemical334 exosomes/mLGlioblastoma, breast, and lung cancers [155,156,157,158,159,160]
COFsColorimetric1.6 × 105 exosomes/mLColorectal cancer[165]
Carbon nanomaterialsCNTsColorimetric5.2 × 108 exosomes/mLBreast[173]
CNTsFluorescence1.5 × 106 exosomes/mLN/A[174]
CNTsFET0.87 aM exosomesBreast cancer[175]
CNTsElectrochemical1 exosome/mLN/A[176,177,178]
g-C3N4 NSsColorimetric1.4 × 109 exosomes/mLBreast cancer[182]
GrapheneFET9 × 103 exosomes/mLProstate and
breast cancers
[186,187,188,189,190]
Other nanomaterialsConductive polymer NWsElectricN/ALung cancer[194]
DNA NPsFluorescenceN/AN/A[195]
DNA NPsElectrochemical9.5 × 102 exosomes/mLBreast cancer
and leukemia
[196,197,198,199,200,201]
CuS NPsChemiluminescence104 exosomes/mLBreast cancer[202]
Lipid-based NPsFluorescence N/ALung cancer[203]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Taylor, M.L.; Giacalone, A.G.; Amrhein, K.D.; Wilson, R.E., Jr.; Wang, Y.; Huang, X. Nanomaterials for Molecular Detection and Analysis of Extracellular Vesicles. Nanomaterials 2023, 13, 524. https://doi.org/10.3390/nano13030524

AMA Style

Taylor ML, Giacalone AG, Amrhein KD, Wilson RE Jr., Wang Y, Huang X. Nanomaterials for Molecular Detection and Analysis of Extracellular Vesicles. Nanomaterials. 2023; 13(3):524. https://doi.org/10.3390/nano13030524

Chicago/Turabian Style

Taylor, Mitchell Lee, Anthony Gregory Giacalone, Kristopher Daniel Amrhein, Raymond Edward Wilson, Jr., Yongmei Wang, and Xiaohua Huang. 2023. "Nanomaterials for Molecular Detection and Analysis of Extracellular Vesicles" Nanomaterials 13, no. 3: 524. https://doi.org/10.3390/nano13030524

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.