Abstract
Background: Surgical aortic valve replacement with rapid deployment bioprosthesis guarantees good hemodynamic results but carries the risk of paravalvular leaks. To address this issue, an annulus stabilization technique has been recently developed. Methods: Clinical and hemodynamic parameters from patients treated for aortic valve replacement with the rapid deployment bioprosthesis and a concomitant annulus stabilization technique were prospectively collected and retrospectively analyzed. Echocardiographic data at discharge and at 1-year follow-up were collected and analysed. Results: A total of 57 patients (mean age 74.3 ± 6.1 years) with symptomatic aortic valve stenosis underwent aortic valve replacement with the rapid deployment bioprosthesis and concomitant annulus stabilization technique (mean valve size: 23.8 ± 1.9 mm). Combined procedures accounted for 56.1%. Hospital mortality was 1.8% and a new pacemaker for conduction abnormalities was implanted in 10 patients. The pre-discharge echocardiographic control showed absence of paravalvular leaks of any degree in all patients with mean valve gradient of 9.6 ± 4.0 mmHg. The 1-year echocardiographic control confirmed the good valve hemodynamic (mean gradient of 8.0 ± 2.8 mmHg) and absence of leaks. Conclusion: In this preliminary clinical experience, the annulus stabilization technique prevents postoperative paravalvular leaks after rapid deployment aortic valve implantation, up to 1-year postoperatively. Studies on larger series are of paramount importance to confirm the long-term efficacy of this new surgical technique.
1. Introduction
Surgical aortic valve replacement (SAVR) with use of biological prosthesis remains the treatment of choice in case of aortic valve disease, reasonable surgical risk, and adequate patient’s age. Recently, the rapid deployment Intuity™ heart valve system (Edwards Lifesciences, Irvine, CA, USA) has been developed in order to improve the surgical implanting time and facilitate the aortic valve replacement in minimally invasive settings [1,2,3]. This bioprosthesis combines the excellent hemodynamic characteristics of the well-known Perimount™ pericardial valve (Edwards Lifesciences, Irvine, CA, USA) with the advantages of an innovative implanting system consisting of a balloon-expanding stent placed below the sewing ring level. The Intuity valve has already shown excellent hemodynamic results in published studies, as well as an extreme versatility, but still carries the risk of postoperative mild to moderate paravalvular leak (PVL), mainly related to the intrinsic characteristics of both the aortic annulus and the fixation system [4,5,6,7]. Therefore, we recently proposed an innovative surgical technique aimed at reducing the risk of PVL following the implantation of the Intuity valve system. This technique consists of a surgical stabilization of the aortic annulus that is performed in concomitance with the aortic valve replacement and allows a better match between the annulus itself and the stent of the Intuity valve [8]. The present study analyses the hemodynamic results and the presence of PVL in a group of patients treated for aortic valve stenosis with the Intuity valve system and concomitant annulus stabilization technique.
2. Methods
This is a monocentric non-randomized retrospective study including patients suffering from aortic valve disease (isolated or not) that were operated on for aortic valve replacement with the rapid deployment Intuity valve system and concomitant annulus stabilization technique. Patients signed the informed consent for the surgical procedure and for the treatment of the anonymized clinical data for research purposes. The present investigation abides by the principles outlined in the Declaration of Helsinki (Ethical Principles for Medical Research Involving Human Subjects) adopted by the 18th WMA General Assembly in Helsinki, Finland, June 1964. Ethical review and approval were waived for this study given the retrospective nature of this work.
2.1. The Rapid Deployment Intuity Valve System
The Intuity valve system employed in the present study is the model 8300A from Edwards Lifesciences, available in 5 sizes: 19, 21, 23, 25, and 27 mm. The bioprosthesis is a tri-leaflet stented bovine pericardial valve with a cloth-covered balloon-expanding stent placed below the sewing ring and protruding for 6.6–8.0 mm into the left ventricular outflow tract (Figure 1). The valve requires 3 guiding sutures placed at the nadir of the leaflets’ insertions to the aortic valve annulus, and the nominal balloon inflation pressure required to expand the stent ranges between 4.5 and 5.0 atmosphere according to the manufacturer and depending on the valve size. A layer of low-density polyester cloth envelops the stent to prevent PVL and facilitate the match between the valve and the annulus.
Figure 1.
The rapid-deployment Intuity™ aortic valve system (Edwards Lifesciences, Irvine, CA, USA).
2.2. The Annulus Stabilization Technique
After removing the aortic leaflets and placing the three guiding sutures, a 3-0 polypropylene purse string suture is performed along the bottom edge of the aortic annulus (Figure 2) [8]. The suture starts at left side (surgical view) of the commissure between the non-coronary and the left-coronary cusp and runs, clockwise, 1–2 mm below and parallel to the edge of the aortic annulus. In order to prevent the risk of atrio-ventricular block with subsequent pacemaker implantation, care is taken when the suture approaches the fibrous trigon. In that region, the suture is brought above the annulus and passed behind the commissure. Then, the suture is brought again below the annulus and parallel to the hinge point of the anterior mitral leaflet and finishes at the right side of the commissure between the non-coronary and the left-coronary cusp. At the end of this phase, the purse string suture is not pulled and is left on stand-by. Hence, after inserting the Intuity into the annulus, ballooning the stent, and tightening the 3 guiding sutures, the valve holder is removed and the Intuity is inspected. When the valve is well seated and well-functioning, the purse string suture for the annulus stabilization is pulled and tightened in order to better match the annulus to the stent and prevent paravalvular leaks.
Figure 2.
A schematic view of the 3-0 polypropylene purse string suture (red line) seen from the surgeon’s point of view. LCA = left coronary artery; RCA = right coronary artery. The brown triangle identifies the fibrous trigon.
2.3. Definitions
Hospital mortality is defined as any death occurring during the hospitalization or within 30 days from the index surgical procedure. Echocardiographic data were collected preoperatively, at discharge, and at one-year follow-up. The degrees of PVL at echocardiographic control were defined as none or trace (not detected or minimal jet (+)), mild (++), moderate (+++), and severe (++++).
2.4. Statistical Analysis
Descriptive data were collected, after anonymization, in an Excel spreadsheet (Microsoft Corporation, Cupertino, CA, USA). Continuous variables are described as mean with standard deviation or as median and interquartile range. Dichotomous variables are expressed as absolute number with a percentage of the total.
3. Results
From September 2015 to September 2021, 57 consecutive patients with severe symptomatic aortic valve stenosis underwent aortic valve replacement with the Intuity valve system and concomitant annulus stabilization technique. The mean age was 74.3 ± 6.1 years and 35.1% were female patients. Preoperative characteristics are listed in Table 1. The preoperative echocardiogram showed mean left ventricular ejection fraction of 59.7 ± 9.1%, mean aortic orifice area of 0.78 ± 0.2 cm2, and mean aortic valve gradient of 42.9 ± 18.4 mmHg.
Table 1.
Patients’ characteristics.
The surgical and echocardiographic details are listed in Table 2. The procedures were performed either through a full sternotomy (n = 30; 52.6%) or an upper mini-sternotomy in case of isolated SAVR (n = 27; 47.4%). The mean Intuity valve size was 23.8 ± 1.9 mm, the mean aortic cross-clamp time was 71.9 ± 23.4 min, the mean cardiopulmonary bypass time was 95.7 ± 31.4 min, and the mean surgical time was 228.4 ± 63.0 min.
Table 2.
Intraoperative data.
Patients were discharged after a median intensive care unit stay of one day (Interquartile Range 1–3) and a median hospital stay of nine days (Interquartile Range 7–11) (Table 3).
Table 3.
Outcome.
Hospital mortality was 1.8% as one patient died on postoperative day seven for multiple organ failure. In terms of postoperative complications, 10 patients (17.5%) required a permanent pacemaker implantation for intra-cardiac conduction abnormalities and 2 patients (3.5%) experienced neurological disorders (1 TIA and 1 non-disabling stroke completely restored before discharge).
The pre-discharge echocardiographic control confirmed the successful positioning of the rapid deployment Intuity aortic valves, with mean gradient of 9.6 ± 4.0 mmHg and absence of any degree of paravalvular leak in all patients (Table 4). The 1-year echocardiographic follow-up (available for 39 patients) confirmed the good valve hemodynamic with mean gradient of 8.0 ± 2.8 mmHg and absence of any degree of PVL.
Table 4.
Echocardiographic data.
4. Discussion
This is a preliminary study aiming at analysing the results of a cohort of patients operated for SAVR with the Intuity aortic valve system and concomitant annulus stabilization technique. The major findings are the confirmation of the good Intuity valve hemodynamic at 1-year follow-up and the absence of any degree of paravalvular leak both at postoperative and at 1-year echocardiographic control.
The Intuity valve system has already proven its good hemodynamic characteristics in previously published studies when compared to the well-renowned standard counterpart (the Perimount valve), but there is still a debate when the risk of permanent pacemaker implantation or the presence of paravalvular leaks are concerned [1,2,3,5,6,7,9,10]. In fact, the rapid deployment Intuity valve features a sub-annular balloon-expanding stent that is dilated after the placement of the valve into the annulus. The effectiveness of this anchoring system depends on the intraoperative valve sizing as well as on the characteristics of the aortic annulus when the radial forces of the stent apply against it [7,11,12,13]. In order to reduce the risk of PVL and to anchor the valve, the balloon-expanding stent is intraoperatively ballooned with 4.5 or 5.0 atmospheres, depending on the valve size. However, this step may damage the cardiac conduction system at the level of the fibrous trigon, requiring the implantation of a permanent pacemaker. Moreover, despite the enlargement of the sub-valvular stent, there is still a risk of postoperative PVL, which can lead to an increased mortality rate when moderate or severe, or can cause haemolysis when it is generated by small defects with high-velocity jets [14]. In the TRITON study as well as in other published retrospective studies, the average rate of mild-to-severe postoperative paravalvular leak after Intuity valve implantation still ranges between 1.4% and 13%, and some patients required surgical reoperations in order to address this issue [1,2,3,5,6,7,9,10,11,12,13].
Following these findings, we recently developed a new surgical technique aiming at better matching the aortic annulus to the Intuity valve ring by using a purse string suture running parallel and below the aortic annulus [8]. After a first feasibility study, this is the first clinical report describing a cohort of SAVR patients with the Intuity valve and annulus stabilization technique in which the valve hemodynamic and the echocardiographic results at discharge, and at 1-year follow-up, are recorded and analysed. The results seem to validate the usefulness of the annulus stabilisation technique by showing absence of any degree of PVL in all patients at discharge and after 1-year postoperatively. This is an important achievement suggesting that this technique, easy and reproducible, can be performed in all patients undergoing SAVR with the rapid deployment Intuity valve system.
However, despite the fact that we did not observe complications related to the annulus stabilization technique, we noticed a pacemaker implantation rate of 17.5%, which is slightly higher than the average rate of 5–12.3% reported in previously published papers [2,5,6,7,10,11,15,16,17,18,19]. As already known, the risk of conduction abnormalities is related to the surgical annulus decalcification but also to the stent of the Intuity valve that applies against the conduction system. Therefore, we can imagine that a possible prevention of intra-cardiac conduction abnormalities following the Intuity valve implantation can be a lower inflation pressure for the stent ballooning. This assumption has already been validated in a study from Vogt and co-workers where not the Intuity but a similar valve, the sutureless Perceval valve, was implanted and ballooned at different pressure levels [19,20]. In their study, the balloon post-dilation at a lower pressure, along with the adoption of others technical improvements, was associated with a reduced rate of pacemaker implantation with the Perceval valve. Thus, we can assume that a concomitant annulus stabilization technique can be helpful in preventing PVL with the Intuity valve while the stent is dilated with a lower balloon pressure level, compared to what recommended by the manufacturer. However, in order to confirm this hypothesis, further clinical studies are needed. Another point is that the annulus stabilization technique itself can be a cause of conduction abnormality if the bites of the suture are too deep at septal level. Nevertheless, this is not easy to show, and we suggest the placement of the suture very close to the ventricular rim of the aortic annulus, and not too deep in that region, in order to lower the risk of conduction system damage.
Finally, the annulus stabilization technique can also be useful in case of pure aortic valve insufficiency or aortic valve bicuspidy as these are, so far, contraindications for the use of the Intuity valve system, as higher degrees of PVL are expected. The annulus stabilization technique can also prevent PVL in patients with bicuspidy and pure regurgitation treated with the Intuity valve, and consequently the Intuity can become a bioprosthesis without contraindications for its use; however, this is yet to be demonstrated.
The present study has some limitations as it is a single-centre retrospective study, with a small sample size, no control group, and a short follow-up time. Nevertheless, this is the first report on the clinical use of a new surgical technique aimed at preventing PVL after rapid deployment Intuity valve implantation. In conclusion, further clinical reports with more patients involved are mandatory to demonstrate the effectiveness of this technique, also in bicuspid aortic valves and in pure aortic regurgitations. We also recommend a longer follow-up study to support the long-term effectiveness of this technique in preventing PVL.
Author Contributions
Conceptualization, E.F., E.C. and R.L.; methodology, E.F., E.C. and T.T.; validation, F.T., A.P., G.P. and S.D.; formal analysis, E.F. and E.C.; investigation, E.F. and E.C.; resources, E.F. and E.C.; data curation, E.F. and E.C.; writing—original draft preparation, E.F. and E.C.; writing—review and editing, E.F., E.C., R.L, G.P. and S.D.; supervision, E.F. and S.D.; project administration, E.F. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study was conducted according to the guidelines of the Declaration of Helsinki. Ethical review and approval were waived for this study, due to its retrospective characteristics.
Informed Consent Statement
Informed consent for the retrospective use of anonymized clinical data was obtained from all subjects involved in the study.
Data Availability Statement
All data are available at Cardiocentro Ticino Institute.
Conflicts of Interest
E. Ferrari is a consultant for Edwards Lifesciences. Other authors do not declare conflict of interests.
References
- Borger, M.A.; Dohmen, P.; Misfeld, M.; Mohr, F.W. Current trends in aortic valve replacement: Development of the rapid deployment EDWARDS INTUITY valve system. Expert Rev. Med. Devices 2013, 10, 461–470. [Google Scholar] [CrossRef] [PubMed]
- Kocher, A.A.; Laufer, G.; Haverich, A.; Shrestha, M.; Walther, T.; Misfeld, M.; Kempfert, J.; Gillam, L.; Schmitz, C.; Wahlers, T.C.; et al. One-year outcomes of the Surgical Treatment of Aortic Stenosis with a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the Edwards Intuity Valve System. J. Thorac. Cardiovasc. Surg. 2013, 145, 110–115. [Google Scholar] [CrossRef] [PubMed]
- Pelce, E.; Porto, A.; Gariboldi, V.; Ben Lagha, A.; Amanatiou, C.; Collart, F.; Theron, A. Five-year outcomes of rapid-deployment aortic valve replacement with the Edwards Intuity valve. J. Card. Surg. 2021, 36, 2826–2833. [Google Scholar] [CrossRef] [PubMed]
- Ferrari, E.; Siniscalchi, G.; Marinakis, S.; Berdajs, D.; von Segesser, L.K. Fast implantable aortic valve implantation and concomitant mitral procedures. Interact. Cardiovasc. Thorac. Surg. 2014, 19, 682–684. [Google Scholar] [CrossRef] [PubMed][Green Version]
- Ferrari, E.; Roduit, C.; Salamin, P.; Caporali, E.; Demertzis, S.; Tozzi, P.; Berdajs, D.; von Segesser, L. Rapid-deployment aortic valve replacement versus standard bioprosthesis implantation. J. Card. Surg. 2017, 32, 322–327. [Google Scholar] [CrossRef] [PubMed]
- Wahlers, T.C.W.; Andreas, M.; Rahmanian, P.; Candolfi, P.; Zemanova, B.; Giot, C.; Ferrari, E.; Laufer, G. Outcomes of a rapid deployment aortic valve versus its conventional counterpart: A propensity-matched analysis. Innovations 2018, 13, 177–183. [Google Scholar] [CrossRef] [PubMed]
- Arribas-Leal, J.M.; Rivera-Caravaca, J.M.; Aranda-Domene, R.; Moreno-Moreno, J.A.; Espinosa-Garcia, D.; Jimenez-Aceituna, A.; Perez-Andreu, J.; Taboada-Martin, R.; Saura-Espin, D.R.; Canovas-Lopez, S.J. Mid-term outcomes of rapid deployment aortic prostheses in patients with small aortic annulus. Interact. Cardiovasc. Thorac. Surg. 2021, 33, 695–701. [Google Scholar] [CrossRef]
- Ferrari, E.; Siniscalchi, G.; Tozzi, P.; von Segesser, L.K. Aortic annulus stabilization technique for rapid deployment aortic valve replacement. Innovations 2015, 10, 360–362. [Google Scholar] [CrossRef]
- D’Onofrio, A.; Tessari, C.; Cibin, G.; Lorenzoni, G.; Martinelli, G.L.; Solinas, M.; Gerosa, G.; INTU-ITA Group; Gregori, D.; Alamanni, F.; et al. Clinical and Hemodynamic Outcomes of Rapid-Deployment Aortic Bioprostheses. Semin. Thorac. Cardiovasc. Surg. 2021. [Google Scholar] [CrossRef] [PubMed]
- Berretta, P.; Meuris, B.; Kappert, U.; Andreas, M.; Fiore, A.; Solinas, M.; Misfeld, M.; Carrel, T.P.; Villa, E.; Savini, C.; et al. Sutureless versus rapid deployment aortic valve replacement: Results from a multicentric registry. Ann. Thorac. Surg. 2021, in press. [Google Scholar] [CrossRef] [PubMed]
- Di Eusanio, M.; Berretta, P. The sutureless and rapid-deployment aortic valve replacement international registry: Lessons learned from more than 4500 patients. Ann. Cardiothorac. Surg. 2020, 9, 289–297. [Google Scholar] [CrossRef] [PubMed]
- Sohn, S.H.; Kang, Y.; Kim, J.S.; Choi, J.W.; Jang, M.J.; Hwang, H.Y. Direct comparison of rapid deployment versus sutureless aortic valve replacement: A meta-analysis. J. Thorac. Dis. 2021, 13, 2203–2215. [Google Scholar] [CrossRef] [PubMed]
- Park, S.J.; Rhee, Y.; Lee, C.H.; Kim, H.J.; Kim, J.B.; Choo, S.J.; Lee, J.W. 3-Dimensional computed tomographic assessment predicts conduction block and paravalvular leakage after rapid-deployment aortic valve replacement. Eur. J. Cardiothorac. Surg. 2021, ezab431. [Google Scholar] [CrossRef] [PubMed]
- Bernard, S.; Yucel, E. Paravalvular Leaks-From Diagnosis to Management. Curr. Treat. Options Cardiovasc. Med. 2019, 21, 67. [Google Scholar] [CrossRef] [PubMed]
- Sohn, S.H.; Kim, K.H.; Kang, Y.; Kim, J.S.; Choi, J.W. Recovery from Conduction Abnormalities After Aortic Valve Replacement Using Edwards Intuity. Ann. Thorac. Surg. 2021, 112, 1356–1362. [Google Scholar] [CrossRef] [PubMed]
- Gonzalez-Barbeito, M.; Arribas, J.M.; Vazquez, A.; Carnero, M.; Sarralde, J.A.; Cal-Purriños, N.; Cánovas, S.J.; Maroto, L.; Gutiérrez, F.; Hornero, F.; et al. Risk Factors for Postoperative Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement: Results from the RADAR Registry. Adv Ther. 2021, 38, 1832–1842. [Google Scholar] [CrossRef] [PubMed]
- Hori, D.; Yamamoto, T.; Kusadokoro, S.; Fujimori, T.; Mieno, M.N.; Kimura, N.; Yamaguchi, A. Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve. J. Artif. Organs. 2021. [Google Scholar] [CrossRef] [PubMed]
- Romano, M.A.; Koeckert, M.; Mumtaz, M.A.; Slachman, F.N.; Patel, H.J.; Chitwood, W.R., Jr.; Barnhart, G.R.; Grossi, E.A.; TRANSFORM Trial Investigators. Permanent Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement. Ann. Thorac. Surg. 2018, 106, 685–690. [Google Scholar] [CrossRef] [PubMed]
- Pollari, F.; Vogt, F.; Fischlein, T. Higher rates of pacemaker implantation after rapid-deployment intuity aortic valve replacement: Can it be improved? Eur. J. Cardiothorac. Surg. 2021, 59, 287. [Google Scholar] [CrossRef] [PubMed]
- Vogt, F.; Moscarelli, M.; Nicoletti, A.; Gregorini, R.; Pollari, F.; Kalisnik, J.M.; Pfeiffer, S.; Fischlein, T.; Santarpino, G. Sutureless aortic valve and pacemaker rate: From surgical tricks to clinical outcomes. Ann. Thorac. Surg. 2019, 108, 99–105. [Google Scholar] [CrossRef] [PubMed]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).