The Ammonia Adsorption and Desorption Behavior of Nafion

1
Institute of Energy Technologies (IET-4)—Electrochemical Process Engineering, Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
2
Jülich Aachen Research Alliance (JARA-Energy), Faculty of Electrical Engineering and Information Technology, RWTH Aachen University, Schinkelstr. 2, 52062 Aachen, Germany
3
Institute of Energy Materials and Devices (IMD-3)—Photovoltaics, Forschungszentrum Jülich GmbH, 52428 Jülich, Germany
4
Faculty of Mechanical Engineering, Ruhr-Universität Bochum, Synthetic Fuels, Universitätsstr. 150, 44801 Bochum, Germany
*
Author to whom correspondence should be addressed.
Retired.
Membranes 2025, 15(5), 149; https://doi.org/10.3390/membranes15050149
Submission received: 4 March 2025 / Revised: 14 April 2025 / Accepted: 15 April 2025 / Published: 14 May 2025
(This article belongs to the Section Membrane Applications for Energy)

Abstract

The electrochemical nitrogen reduction reaction (eNRR) for electrochemical ammonia (NH3) synthesis is considered a promising alternative to the energy-intensive and highly CO2-emitting Haber-Bosch process. In numerous experiments, the Nafion membrane has been used as an electrolyte or separator. However, Nafion adsorbs and desorbs NH3, leading to erroneous measurements and making reproducibility extremely difficult. This study systematically investigates the interaction between NH3 and Nafion, underscoring the strength of the interaction between ammonium-ions (NH4+) and protons (H+). We found that minute quantities of synthesized NH3 are prone to persist within the membrane, albeit without affecting the ion conductivity and resistivity of Nafion. Consequently, the removal of NH3 from the membrane can occur under conditions where synthesis is not viable. The objective of this work is to heighten awareness regarding the interaction between NH3 and Nafion and contribute to the attainment of reliable and reproducible outcomes in eNRRs.

1. Introduction

Ammonia (NH3) is one of the most widely produced chemicals in the world, with an annual production exceeding 170 million tons [1,2]. NH3 and compounds derived from it play a crucial role in the agricultural, pharmaceutical, and textile industries. Notably, more than 80% of the NH3 produced is utilized for the production of fertilizers [3,4]. Without the industrial production of NH3 the present world population would not exist and could not be fed [5,6].
In addition to these factors, NH3 has been gaining increasing attention in the energy sector due to its potential as an energy carrier. This interest stems from its high H2 content of 17.8 wt%, and the energy density of 15.6   M J   L −1 of liquefied NH3, which is 70% higher than that of liquid H2, 9.1   M J   L −1 at a cryogenic temperature, making NH3 viable as a carbon-neutral energy carrier [7]. Additionally, the transport and storage of NH3 is simple compared to H2, as it can be liquefied and transported at 20 °C and an excess pressure of 8.6 bar [4]. Furthermore, it can be employed as a fuel in a direct ammonia fuel cell or indirectly in a hydrogen fuel cell [8]. It can also utilized as a fuel in gas turbines or generators [9].
However, for more than a hundred years, NH3 has been synthesized using the Haber-Bosch process. However, for more than a hundred years, NH3 has been synthesized using the Haber-Bosch process. This process is extremely energy intensive, consuming about 1% of the power generated globally [10] and is responsible for 1 to 2% of annual CO2 emissions [11,12,13]. The production of 1 t results in the generation of approximately 2 t of CO2 [14]. Given the substantial energy consumption and significant CO2 emissions entailed by the Haber-Bosch process, there is a compelling need to enhance the efficiency, sustainability, environmental-friendliness, and reduce the CO2 emissions of NH3 synthesis [12]. Furthermore, the decentralization of NH3 production is important for reducing dependencies in individual production countries and lowering transport and associated energy costs. Hence, the electrochemical NH3 synthesis is considered a promising, environmentally-friendly method for converting N2 into NH3 in mild conditions (below 100 °C) by means of adsorption, activation and desorption processes [15]. A CO2-neutral production process can be achieved if renewable energy is used for electricity supply and the utilization of air and water as reactants.
However, ammonia production rates are still fairly low and are hardly confirmed by the contribution of the electrochemical nitrogen reduction reaction (eNRR). This is due to the fact that different non-negligible contaminants affect the synthesis and result in false amounts of NH3 being detected. There are several sources of contamination [16,17]. One major issue is the absorption of NH3 in the electrolyte. In numerous cases, the proton-conducting membrane, Nafion, is used as the electrolyte and separator between the anode and cathode [18,19,20,21]. Due to the basic character of NH3, it reacts with the protons of Nafion, forming NH4+ ions, i.e., the NH4+-form of Nafion. This in turn has a strong influence on the unequivocal determination of the NH3 production rate, as atmospheric NH3 pollution, impurities in the feed-gas stream like NH3 itself, and impurities present within the electrochemical cell can persist in the form of NH4+ within the membrane, thereby complicating the analysis of NH3 produced by eNRR. The NH4+-ions resulting from the impurities can be expelled from the membrane and subsequently dissociate into NH3 at the cathode, leading to a falsely interpreted production rate of NH3 particularly with respect to the catalyst and operating parameters. Conversely, if NH3 is produced within the cell, it may be adsorbed by the membrane, thereby preventing the detection of NH3 at the outlet of the cell. This outcome leads to a false negative result. Moreover, the NH4+-ions within the membrane have been demonstrated to significantly affect the ion conductivity and ohmic resistance of the electrolysis system [22,23,24,25,26,27].
The objective of this study is to enhance comprehension of the adsorption behavior of NH3/NH4+ in Nafion. The investigation aims to determine the specific conditions and extent to which the NH4+-ions introduced into the membrane are expelled as NH3 from the cell especially from the membrane. In addition, this study considers the influence of the desorbed NH4+ on the properties of the Nafion membrane. The paper commences with an in-depth analysis of the adsorption and desorption behavior exclusively within the Nafion membrane. Subsequently, Nafion is integrated into an electrochemical cell configuration and its behavior meticulously examined under the dynamic influence of electrochemical reactions.

2. Materials and Methods

2.1. Nafion

Nafion® from Chemours (Tyrone, Wilmington, DE, USA) is a perfluorinated membrane, whose ion conductivity is attributable to the presence of the ionic sulfonic acid groups (R-SO2-OH). Figure 1 displays the structural formula [28] and a schematic illustration of the channel-shaped microstructure of Nafion. It is utilized in an acidic or neutral environment due to its good proton conductivity, chemical, and mechanical stability. Based on its excellent properties, Nafion is the standard material used as a proton-conducting membrane and as a separator in electrolysis processes under these environmental conditions [29].
In this study, Nafion 115, with a thickness of 127 μ m and size of 42 * 42 mm2, was used. The average weight was determined, based on five dried membrane pieces, yielding an average of 443.2   m g with an error of ± 15.3   m g . The pieces were dried in an oven at 80 °C for 1 h before the weight was measured.
The equivalent weight is defined as the value of the amount of substance of the sulfonic acid groups (-SO3H) per gram of dry polymer. For Nafion, this value is 1100 g mol−1 [30]. With respect to the weight of the membrane pieces, these contain 403 μ mol ± 14 μ mol of sulfonic acid groups.

2.2. Ion Exchange

To introduce NH3 in the form of NH4+-ions into the membrane, the protons (H+), which are bound to the sulfonic acid groups, must be exchanged with NH4+-ions. This exchange occurs in a one-to-one ratio. Thus, the maximum amount of NH3/ NH 4 + , that can be bound inside the polymer structure is 403 μ mol ± 14 μ mol. Ammonium sulfate ((NH4)2SO4) is utilized as the NH4+ source. Figure 2 depicts the principle of the ion exchange. Nafion 115 is introduced into a 25 m L (NH4)2SO4 solution. The immersion time was varied in order to investigate its influence. The ion exchanged Nafion membrane in NH4+-form is also depicted in Figure 2.
The study aims to investigate the influence of the quantity of NH 4 + in the solution and on the ion exchange. For this reason, (NH4)2SO4 solutions were prepared with different quantities of substance ( n ) of NH 4 + -ions in relation to the amount of H + in the membrane. The ratio 1:1 (Table 1) therefore means that the amount of NH 4 + in the solution is the same as the amount of H + in the membrane. To gain the specific amount of substance of NH4+, the mass (m) of (NH4)2SO4 must be calculated using the following equation (Equation (1)):
m ( ( NH 4 ) 2 SO 4 ) = β ( NH 4 + ) · V · M ( ( NH 4 ) 2 SO 4 ) 2 · M ( NH 4 + )
where β is the mass concentration inside the volume (V) of 25 m L . The molar masses are M((NH4)2SO4) = 132.14   g mol−1 and M(NH4+) = 18.04   g mol−1.
The corresponding quantity of NH 4 + to the ratio, the concentration of NH 4 + ( c ), the mass concentration of NH 4 + in the prepared (NH4)2SO4 solution, and the required mass of (NH4)2SO4 for preparing the specific NH 4 + concentration are also shown in Table 1.
After the ion exchange took place, the Nafion membrane was dried and introduced into a sulfuric acid (H2SO4) solution to expel the NH 4 + -ions from the membrane. The H2SO4 solution facilitates a re-exchange of NH4+ with H+. Subsequently, the amount that was exchanged is analyzed.
The concentration of the H2SO4 solution is 0.45 mol L −1 and the volume is 25 m L , and so a substantial excess of H+ is available.

2.3. Ammonia/Ammonium Determination

The quantity of NH4+ in the residual (NH4)2SO4 solution and in the H2SO4 solution was quantified using the indophenol blue method, which is a common technique for determining NH3 levels [4]. This method is particularly adept at measuring especially low concentrations of NH3/NH4+. The indophenol method is based on the method reported by Li et al. and Zhao et al. [31,32]. 2 m L of the sample solution was introduced into a sample vessel. 2 m L of a 1 M sodium hydroxide (NaOH) solution, including sodium salicylate and potassium sodium tartrate was added. The solution contains 5 g of sodium salicylate and 5 g of potassium sodium tartrate in 100 m L of 1 M NaOH. Subsequently, 0.2   m L of a nitroprusside solution was added, containing 0.2   g of nitroprusside that had been dissolved in 20 m L of deionized water. In the end, 1 m L of a sodium hypochlorite solution containing 0.005% sodium hypochlorite was added to the solution. Between each addition, the solution was thoroughly mixed using a vortex mixer. The samples were stored for 30 min and subsequently analyzed using the VIS-spectrometer “PV4 Spectrophotometer”, from VWR at a wavelength of 655 n m in accordance with the methodology proposed by Zhao et al. [31]. In order to achieve suitable concentrations, the samples were either diluted by 1:20 or 1:50.

3. Electrochemical Cell

For studying the NH3 adsorption and desorption behavior of Nafion 115 in an electrochemical cell, the membrane was assembled into a membrane electrode assembly (MEA). The MEA is the core of an electrochemical cell and is placed in the center of the cell. Figure 3 illustrates the cell set-up. Nafion 115 was introduced into solutions with different concentrations of (NH4)2SO4. 2 m g   c m −2 of IrOx catalyst, supplied by Alfa Aesar/Thermo Fisher Scientific (Haverhill, MA, USA) was spray-coated onto a titanium felt substrate from Bekeart, Bekipor® (Zwevegem, Belgium) 2GLD10-0.35. Prior to the spray-coating of the catalyst, a thin Ir-layer was sputter-deposited onto the substrate. This electrode functions as the anode. Knife-coating was employed to deposit 60% Pt/C HiSpec 9100 from Johnson Matthey (London, UK) onto a carbon felt substrate from Freudenberg (Weinheim, Germany) H2315 CX312. This electrode functions as the cathode. The loading of the catalyst was 1.3– 1.4   m g   c m −2. Both electrodes were produced in-house. These electrodes are common material for the reactions of the water electrolysis, H2O oxidation and H+ reduction [33,34]. In order to avoid the transfer of NH4+ from the membrane to the electrodes and to facilitate disassembling for analysis, a hot-pressing step was not employed. The active cell area was 6.25  cm2. To investigate the electrochemical change in more detail, the impedance spectra were fitted with the Zview®4 software from Scribner.
The anode and cathode side had identical components installed from the outside to the inside. The end plates were stainless steel and connected to the potentiostat “Octostat 500” from Ivium® (Eindhoven, The Netherlands) which was utilized in all of the experiments and has a maximum current supply of 5 A. The anode bipolar plate was stainless steel coated with platinum, and the cathode bipolar plate was stainless steel coated with gold. The bipolar plates featured a meandering flow field structure. The cell was sealed using PTFE layers, which were customized according to the thickness of the porous transport layer (PTL). The cell assembly process initially involved tightening at a torque of 3 N m , followed by a secondary tightening step at 5 N m . The 5 N m tightening was then repeated to ensure secure sealing.
As illustrated in Figure 4, the test rig is composed of several components. Equation (2) describes the oxidation of H2O at the anode, through the application of electrical energy, resulting in the production of O2. If the resulting H+ interacts with NH4+ within the membrane, NH4+ is displaced with H+ within the membrane. Consequently, NH4+ desorbs from the membrane. At the cathode, NH4+ deprotonates, producing NH3. The dissociated H+ is reduced to H2 with the supplied e from the cathode (Equation (3)).
(2) Anode:         2   H 2 O 4   H + + 4   e + O 2 (3) Cathode: 4   NH 4 + + 4   e 4 NH 3 + 2   H 2
H2O was pumped into the anode of the electrochemical cell with a circulation pump. The flow rate of the pump was set at 10 m L /min. On the cathode side, N2 was introduced as a carrier gas via a mass flow controller from Brooks Instruments (Dresden, Germany) to remove NH3 from the cell. The cleaning trap filled with H2SO4 is needed to remove impurities of NH3 from the N2 feed gas stream, otherwise these impurities can be detected and lead to false results. The trap collects the discharged NH3 for subsequent determination via the indophenol method. In the case that H+ does not displace NH4+, only H2 is produced in the cathode (Equations (4) and (5)).
(4) Anode:         2   H 2 O 4   H + + 4   e + O 2 (5) Cathode: 4   H + + 4   e 2   H 2

4. Results and Discussion

4.1. Ion Exchange

4.1.1. Ammonia Adsorption

The thickness and size of the membrane was determined before and after insertion of the membrane pieces in the ammonium sulfate solution using a caliper gauge. Swelling, and an increase in the size and thickness of the membrane, was not detected. The swelling behavior of Nafion in the literature is also different [35,36].
The ion exchange of H+ with NH4+ was studied at temperatures ranging from 25 °C to 80 °C and for different exchange times of 30 and 60 min. The objective was to study the effects of elevated temperatures and extended exchange times. However, it has not been proven that the quantity of the ion exchange increases at higher temperatures. Figure S1, which can be found in the Supplementary Information, illustrates this. It is assumed that the temperature difference is insufficient to influence the equilibrium. In addition, no difference in the quantity of ion exchange was observed when varying the exchange time while the membranes were placed in the same solution concentration at the same temperature (see Figure S2).
Despite this, a scattering of results was observed when the experiments were repeated. Figure 5 shows the amount of NH4+ remaining in the (NH4)2SO4 solution with the respective mean values and error bars for the ratio of NH 4 + vs. H+ 1:1 (red) and 2:1 (blue) (c(NH4+) = 0.016 and 0.032 mol L −1). The ion exchange was conducted at 25 °C (ambient temperature) for a period of 1 h for both ratios. The spread of the average value of the ratio 1:1 was ±17 μ mol, and in the case of 2:1, it was ±26 μ mol.
The question arises as to whether there is a correlation between the provided quantity of NH4+-ions and the ion exchange. Table 1 exhibits the diverse proportion of NH4+ vs. H+, which were prepared to subsequently analyze the ion exchange. The ion exchange process of the NH4+-ions and the H+ is an equilibrium-controlled process (Equation (6)). In the initial stage, the NH4+-ions are exclusively present in the solution (c(NH4+, Sol)), whereas the protons are located within the membrane (c(H+, Mem)). Over time, the process of ion exchange occurs, resulting in the exchange of H+ within the membrane with NH4+. In doing so, the H+ desorbs into the solution.
c ( NH 4 + , S o l ) + c ( H + , M e m ) < = > c ( NH 4 + , M e m ) + c ( H + , S o l )
The equilibrium constant (Keq) is determined through the concentrations of the ions in the media (membrane and solution) after reaching the equilibrium state.
K e q = c ( NH 4 + , M e m ) · c ( H + , S o l ) c ( NH 4 + , S o l ) · c ( H + , M e m )
In light of the assumption that the volume of the solution and the membrane remain constant, it is reasonable to calculate the equilibrium constant using the amount of substance in place of the concentration. As previously outlined in Section 2.2, the quantity of protons present within the membrane is 403   μ mol. The quantity of NH 4 + -ions in the solution depends on the chosen ratio of NH 4 + against H + , as illustrated in Table 1 ( NH 4 + vs. H + ). The adsorbed NH 4 + -ions within the membrane are quantified through the indophenol method after extracting it from the membrane with an excess of sulfuric acid solution (see Section 2.3). Given that the exchange of NH 4 + -ions and H + occurs in one-to-one ratio, the original NH 4 + solution now contains an equivalent quantity of H + to that of NH 4 + within the membrane.
Figure 6 shows the determined equilibrium constant of the tested NH4+ vs. H+ ratios as red squares with their respective error bars. As Keq > 1, the equilibrium is on the product side. Consequently, the NH 4 + -ions from the solution prefer to exchange with the H + within the membrane. The error bars of the ratios 0.8:1 and 1.5:1 are larger in comparison to those of 0.5:1 and 1:1, as the determined amount of NH 4 + in the solutions of these ratios showed a larger scatter compared to the latter one. This scattering has a magnifying effect on the error bar of K eq. Additionally, the error bars of the ratio of 2:1 is very large, because the concentration of H + in the membrane after exchange is calculated by subtracting the concentration of the NH 4 + -ions in the membrane after exchange from the concentration of H + in the membrane before the exchange. For the 2:1 ratio, most protons are exchanged and therefore the difference is small and on the order of the magnitude of errors of those of the minuend and subtrahend. This leads to a substantial error in Keq for the 2:1 ratio. The average value of Keq is 2.81 ± 2.62, including the ratio of 2:1. If this ratio is not considered for this reason, Keq is 2.00 ± 1.31, as depicted by the blue line in Figure 6.

4.1.2. Ammonia Desorption

The ion-exchanged Nafion membranes were immersed in a H2SO4 solution for evaluating the desorption kinetic of NH3/ NH 4 + in relation to time and temperature. This study aimed to elucidate whether increased temperature correlates with increased NH3 desorption. No correlation was found. For the desorbed quantity of NH3 at room temperature up to 80 °C was similar. Furthermore, we sought to determine the impact of the immersion duration in the H2SO4 solution on desorption behavior. The desorption time ranged from 10 to 60 min . Similar results were obtained. The Nafion pieces used, as noted previously, had a size of 17.64   c m 2 and each one contained 403   μ mol ±  14   μ mol of H + , which were bonded to sulfonic acid groups.
The red bar in Figure 7, which is the same as in Figure 5, depicts the average remaining quantity of NH 4 + in the solution. 200   μ mol of NH 4 + remaining in the solution. The green bar illustrates the amount of NH 4 + that was ion-exchanged into the membrane by subtracting the red bar from the membrane’s initial concentration of H + (403– 200   μ mol). The ion-exchanged membranes were placed in three fresh H2SO4 solutions, because during experiments it was found that the NH 4 + -ions were not fully removed from the membrane at first. An equilibrium was established between the membrane and the H2SO4 solution. By replacing the H2SO4 solution with a fresh one, the desorption of NH3 continued. Approximately 85 % of the quantity was removed in the first H2SO4 solution (1. Drag-out NH 4 + ). Nearly 15 % in the second solution (2. Drag-out NH 4 + ) and less than 0.5 % in the third one (3. Drag-out NH 4 + ). The average totaled amount of NH3 that was expelled from the membrane is displayed as the blue bar. It can be concluded that the quantity of NH 4 + that was previously exchanged into the membrane has been recovered within the margin of error.

4.2. Ammonia Desorption in the Electrochemical Cell

4.2.1. Ammonia Desorption

Figure 8 displays the desorption of NH3 during the trials of a ratio of 2:1 NH4+ vs. H+ (c(NH4+) = 0.032 mol L −1) at ambient temperature. The measurement protocol was repeated with a fresh cell, including a fresh MEA, to ensure reproducibility. The first bar of each measurement point is attributed to the first trial (T1), and the second bar is attributed to the second trial (T2). The measurement protocol was carried out in its entirely twice, with each measurement point held for a duration of 30 min. At the beginning of each run, an impedance spectrum was recorded. The impedance spectra will be subsequently discussed. For the splitting of water and the generation of H + , which are needed to drive NH 4 + out from the membrane, an electrical potential is required. For this purpose the potentials 1.5, 1.75, and 2 V were applied, which are common for water electrolysis [37]. As these potentials did not lead to the desorption of NH3, the maximum current supply of the potentiostat, 5 A, resulting in a current density of 0.8 A cm−2, was applied in order to expel NH3. After the current supply, a measurement run was finished and the next started with the stated potentials.
The values are plotted logarithmically and each run is illustrated in a different color. The graphical representation exclusively presents bars corresponding to conditions that lead to NH3 desorbed quantities surpassing the margin of the error of 0.2   μ mol. During the applications of the current density a considerable quantity of NH3/ NH 4 + was expelled from the membrane in proportion to the quantity expelled while the potentials were applied. The desorption rate declines with the second run when the highest current density was applied. In the case of the second run, the determined desorption was only 25 % of that determined in the first run. No desorbed NH3 was detected in the margin of error in the initial run when the potentials were applied and in the second run applying 2 V. However, NH3 was detected in the subsequent run after the current density was applied. This was unexpected as in the first run no NH3 was detected at 1.5 V. Therefore, it is assumed that the NH 4 + -ions were no longer ionically bound in the membrane. They were released by the previous current supply, converted to NH3, remained in the cell and subsequently left the cell by diffusion. The current densities exhibited an increase from the first run to the second, relating to the applied potentials. This increase in current density was attributed to the driving out of NH4+ from the membrane, leading to an enhancement in ionic conductivity and thus an increase in the current density.
A 1:1 ratio of NH4+ vs. H+ was employed (c(NH4+) = 0.016 mol L −1) to study when a different ratio has a major influence on the desorption behavior (Figure 9) at ambient temperature. The absolute desorption of NH3 was lower, yet the qualitative desorption was highly comparable and the experiment was also reproducible. Furthermore, the behavior subsequent to the initiation of the current density of 0.8 A c m −2 was investigated. Therefore, the potential was set to 0 V, precluding any further electrochemical reaction that results in an NH3 desorption. However, NH3 was driven out at the dead-voltage state, as depicted in Figure 9. The results underscore that the NH 4 + -ions were no longer ionically bound, but already in the NH3 state and were subsequently removed by diffusion. Hence, the desorption of NH3 was not solely contingent upon electrochemical processes driven by potential, but diffusion also plays a contributory role. Apparently, some NH3 was removed from the membrane under the current flow and persisted in another part of the cell, from where it could be expelled by a purely diffusive process in the subsequent step with no potentials applied. Additionally, a third run was executed at 0.8 A c m −2. The trend continuous and the desorbed quantity declines with successive runs.
In order to demonstrate the transparency and reliability of NH3 desorption and the resulting consequences of this on the properties of the membrane, both trials of the respective ratios of 1:2 and 1:1 of NH 4 + vs. H + are shown in Figure 10.
The expelled quantity of NH3 was totaled in the respective experiments to determine whether the amount that was ion-exchanged into the membrane was expelled. This result is displayed in Figure 10. Figure 10a displays the outcome of the 2:1 ratio and Figure 10b the outcome of the 1:1 NH4+ vs. H+ ratio. The determined expelled quantities of NH3 are shown as green bars and in red are shown the calculated quantities of NH3/NH4+, which were in the membrane at the start of the trials. The red bar is based on the subtraction of the average value from the initial NH4+ concentration of the (NH4)2SO4 solution and the NH4+ concentration in the solution after the ion exchange. The ratio of the values (green bar divided by the red one) for each experiment is plotted as green square dots on the right-hand y-axis. It can be seen that only 25–30% of the NH3 present in the whole membranes were desorbed from them. It must be taken into account that the active cell areas of the membranes, where the electrochemical reactions occur, were 6.25  cm2, whereas their total areas were 17.64  cm2. The ratios of the desorbed quantities in relation to those in the active cell area are shown as blue dots. A significant proportion of the NH 4 + -ions, between 70 and 80 % , in the active cell area were expelled. The remaining 20 to 30 % of the NH 4 + -ions were still chemically bounded to the sulfonic acid groups within the membrane.
Galvanostatic experiments performed at the maximum current density of 0.8 A c m −2 are presented in Figure 11. On the left-hand side are shown the results of the 2:1 ratio and on the right-hand side those of the 1:1 NH4+ vs. H+ one. The measured voltages were highest during the first run, especially during the second trial of the 2:1 NH4+ vs. H+ (T2) ratio. Apart from this, the voltages decreased up to approximately 600–800 s . Afterwards, they remained constant over time. Compared to the first run, the potentials decreased in the second. This decrease was particularly pronounced in T2 of the 2:1 NH4+ vs. H+ ratio. It is assumed, that in the case of T2, the quantity of the NH 4 + -ions within the active cell area was larger in comparison to T1. However, as a consequence of the elevated current supply during the initial run, approximately 57 % of NH3, which was bounded as NH 4 + to the sulfonic acid groups in the channel-shaped microstructure of Nafion in the active cell area, was expelled from the membrane. This desorption resulted in the liberation of sufficient channels from NH 4 + -ions, thereby drastically increasing the conductivity of H + through the membrane. As a result, a significant reduction in the potential for the second run of T2 was observed, so that the measured potential is similar to that from T1. No substantial change in measured potentials was evident from the second to the third run due to the fact that the remaining NH 4 + -ions within the active cell area of the membrane no longer interact with the incoming H + . Therefore, the membrane resistivity decreased, leading to a reduction in the required potential for the current flow.
Figure 12 shows the respective polarization curves, to which potentials were applied and the current densities measured. During the first run, the measured current densities were low at the potentials of all trials. After the first time 0.8 A c m −2 was applied, a significant amount of NH3 was expelled, resulting in a substantial decrease in the membrane’s resistivity. Thus, the current densities, which were measured during the applied potentials, increased as shown in Figure 12. Notably, the current densities recorded for the 1:1 were found to be higher, which could be attributed to a lower total NH4+ content within the membrane, leading to enhanced conductivity.
Figure 13 depicts the corresponding impedance spectra, which were recorded at the start of each run at the applied voltage of 1.5 V. Each spectrum consists of a high frequency (h.f.) semicircle and exhibits more or less linear behavior at low frequencies (l.f.) with a slope close to 45°. At the lowest frequencies down to 1 Hz, the impedance deviates from the linear slope, tending slightly towards the real axis. This suggests that the l.f. impedance is dominated by a finite diffusion process that can be modeled by, e.g., a finite Warburg impedance. The h.f. semicircle can be interpreted as the parallel connection of a kinetic resistance and a double layer capacitance. Together with the ohmic resistance, the overall impedance can be represented by the well-known Randles equivalent circuit, as shown in Figure 14b. Note that due to the depressed h.f. semicircle, the double layer capacitance was replaced by a constant phase element.
This replacement is most evident in the first run of T1 in Figure 13a, whereas the h.f. semicircle in the second run is not particularly distinct. In the case of T2, a third spectrum was recorded after the second run. A discernible reduction in the ohmic resistance from the first run to the second occurred in both ratios. The impedance spectra emphasize that the presence of NH4+ within the membrane initially has a considerable influence on the ohmic resistance, and therefore on the ion conductivity. However, once a certain quantity is expelled, the remaining NH3/NH4+ in the membrane no longer has a significant influence on the ohmic resistivity, as the ohmic resistance of the third run in Figure 13a is highly comparable to the ohmic resistance of the second run.
In order to investigate the electrochemical change in more detail, the spectra of T2 of the ratio 2:1 NH4+ vs. H+ were fitted (Figure 14a) by means of the Randles circuit shown in Figure 14b. The spectrum of the first run was fitted in a frequency range from 1000–1 Hz and those of the second and third ones were fitted from 1200– 1 Hz. The values of the electrical elements are shown in Table 2. The fits of the other trials and their corresponding tables can be found in the Supplementary Information. The ohmic resistance (RΩ), the charge transfer resistance (RCT), the diffusion resistance (WR), and the diffusion parameter (WT), have in common that they decrease by a factor of 2–3 from the first to the second runs. Conversely, with respect to the fitting error, these parameters remain virtually constant from the second to the third runs. The Warbung exponent (WP) also remains constant from the first to the third runs. It is close to the ideal value of 0.5 that corresponds to a 45° line in the Nyquist plot. The significant error of the constant phase element, which represents the double layer capacitance does not allow the analysis of both the CPE value (CPET) and exponent (CPEP).
Although the significant decrease in the ohmic resistance from the first to the second run is clearly due to the exchange of NH4+ by H+, the corresponding decrease in the other parameters requires some explanation. RCT can be related to the oxygen evolution reaction (OER) at the anode, the hydrogen evolution reaction (HER), and the desorption of NH3 at the cathode. If the OER is assumed to be less affected by the cation exchange in the membrane compared to the cathode reaction, it might be hypothesized that the decrease in the charge transfer resistance from the first to the second run is caused by an increasingly dominating HER. The HER becomes dominating, because less NH4+ is present in the membrane, leading to a better H+ transport in it. The corresponding decrease in WR must be related to the acceleration of a diffusion process. Again, if the OER is negligible, the diffusion velocity of the H+ increases, because the NH4+ in the membrane, which slows down the H+ diffusion velocity, diminishes. WT relates to the effective diffusion length (L) and the diffusion coefficient (D), with the equation W T = L 2 D . If the diffusion length is assumed to be approximately constant, the higher diffusion coefficient of protons compared to NH4+ could explain the decrease in WT. Alternatively, if WT is only related to the diffusion of H+ and considering Fick’s law (Equation (8)),
J = D d C d x
the diffusion coefficient is inversely proportional to the concentration gradient ( d C d x ). This means that if the concentration of H+ increases within the membrane due to less NH4+ within the membrane and less resistivity, the diffusion coefficient decreases, as does the effective diffusion length. J is the flux of the diffusion species.

4.2.2. Whereabouts of Ammonia

To address the questions concerning the whereabouts of NH3/ NH 4 + , the experiments were repeated, the cell was disassembled, and the individual MEA-components were also immersed in an H2SO4 solution so that the amount of NH3/ NH 4 + contained in them was expelled. Moreover, the time trend of the drag-out in the dead-voltage state was examined in greater detail. An MEA cell with Nafion 115, which was ion-exchanged with a solution of an NH4+ concentration of 0.024   M (1.5:1 NH4+ vs. H+), was utilized. The concentration was chosen to determine whether the desorption of NH3/ NH 4 + under the specific conditions was proportional to the ion exchange. Figure 15 displays the amount of NH3 detected during the runs. In the first one, 49.23   μ mol was driven out at 0.8 A c m −2 and without an applied voltage 12.45   μ mol. In the case of the second run, it was 7.37   μ mol and 1.37   μ mol, respectively. Table 3 shows the quantity and ratio of the expelled NH3 ( Σ ntot) during the dead-voltage state and the diffusion-driven drive-out, in comparison to the total drive-out. The corresponding drive-out during the time intervals (V1–V3) is also shown. Approximately 20–25% of the quantity of NH3, which desorbed while supplying 0.8 A c m −2, was expelled when no voltage was applied. Approximately two-thirds of this expelled quantity was driven out within the first ten minutes. In the second time interval, around 25% was removed, whereas 3–10% was removed in the last 10 min. The error of the second run increased strongly. Additionally, the ratios exhibited minor deviations in a second trial. This deviation along with the augmented error observed in the second run, can be attributed to the minimal absolute values of the measured NH3. Such low magnitudes are significantly more susceptible to inaccuracies when expressed in a percentage relationship.
After the experiment had been completed, the cell was disassembled. The active cell area of the membrane was cut out and the active cell area, frame, anode, and cathode were immersed in H2SO4 solutions for 30 min. The portion of the active cell area and the frame that makes up the part of the membrane, which was covered by the gasket during the experiment, were re-inserted into a fresh solution because, as previously stated, not all of the NH4+-ions within the membrane were expelled in the first solution. The detected quantity of NH3 of each component is displayed logarithmically in Figure 16. Most of the detected quantity, 129 μ mol, was found in the frame. This is based on the fact that no electrochemical reaction took place in the frame area but only in the active cell area. In the membrane itself, 22 μ mol remained, which was detected. It is important to note that if the cell remains unused, exchange processes will take place so that NH4+ becomes homogeneously distributed within the membrane.
In the second trial, the cell was disassembled directly after applying a current density of 0.8 A c m −2. The NH3 desorption during the current flow is depicted in Figure 17. The desorption is similar to that in Figure 16, if it is assumed that there is a deviation like that in Figure 8 and Figure 9. Approximately 43 μ mol of NH3 were expelled from the membrane after disassembling the cell and introducing the components in an H2SO4 solution. The quantity of NH3 is similar to the total amount of it expelled in the first test after applying 0.8 A c m −2 plus the remaining substance in the membrane. 122 μ mol of NH3 were detected from the frame. The difference of 7 μ mol compared to the amount depicted in Figure 16 is small when considering the deviation of the ion exchange in Figure 5. The determined amount of NH3 that was found in the electrodes and tube (the connection between the trap and cell) is low. Consequently, the residual amount of substance remained within the membrane. This result highlights the fact that the drag-out of NH 4 + /NH3 from the membrane is an electrochemical and diffusion-driven process.
Figure 18 displays the ratio of the detected quantities of NH3 in relation to the ion exchanged amount with respect to the active cell areas. T1 is the first trial where the time trend of the expelled NH3 was investigated (Figure 15 and Figure 16). The red bar illustrates a ratio of 67% ± 8%, denoting the amount of NH3 expelled electrochemically during the cell measurement in relation to the total ion exchanged amount. The quantity of NH3 released from the electrodes and the membrane when they were immersed into a H2SO4 solution after the electrochemical measurement is added to the electrochemical drag-out. Then a total quantity of 87% ± 10% of the NH4+-ions used previously within the membrane were expelled as NH3 from the membrane. In the case of the second trial where the cell was dismantled directly after applying the current, 51% ± 7% of the initial concentration of NH4+ in the membrane were expelled electrochemically (blue bar). This value is lower than during the first trial, because the quantity of NH3 that was expelled due to diffusion and when the high current density was applied for the second time, remained in the membrane. However, after disassembling and introducing the components in H2SO4 solutions, all of the introduced NH4+-ions in the beginning, were found (dark blue bar). In conclusion, it can be stated that the amount of NH4+ in the active cell area was almost completely recovered by the electrochemical discharge and chemical extraction.

5. Conclusions

In this study, we investigated the interaction of NH3 and Nafion, with the objective of enhancing understanding of the process, which will lead to more reliable ananlysis of electrochemical NH3 synthesis for future work. As expected, it was found that NH4+ prefers to exchange with H+ from Nafion, and the K eq is 2.00 ± 1.31. This results in the persistence of NH 4 + within the membrane structure. The higher the concentration of the solution containing NH4+, the higher the exchange. It has been demonstrated that the quantity of NH 4 + bound to the membrane by adsorption is detected and expelled.
In the MEA cell, the effect of NH4+ in the membrane and also the migration of the ions in the different components was electrochemically investigated by analyzing the current-voltage behavior and impedance spectra, and chemically by analyzing the NH3/NH4+ content in the different components by dissembling the cell at different times in the electrochemical process utilizing the indophenol method. We found that the desorption of NH3 is a process driven by potential and diffusion. Considering the results and errors shown in Table 3, between approximately 10 and 30% of the amount of NH3 that was expelled electrochemically was done so by diffusion in the de-energized state. It was determined that a proportion (20 to 30%) of the protons in the active cell area can be replaced by NH 4 + -ions, without affecting the ohmic resistance and ion conductivity. Consequently, if small amounts of NH3 are synthesized electrochemically in an N2 reduction cell, they may remain as NH 4 + in the membrane unnoticed as the membrane itself remains unaffected. Very high potentials > 2V are needed to expel a significant amount of NH3. However, theoretical calculations by Araujo et al. [38] indicate that NH3 synthesis is not feasible at these high potentials. It is shown in his article that these potentials lead to the complete coverage of the catalyst surface area with H*. For the N2* coverage, the potentials are small and the range is also very narrow. Therefore, it can be inferred that NH3 is detected under conditions in many cases that do not enable NH3 synthesis, leading to false conclusions. Additionally, it is shown that the majority of NH 4 + remains chemically bound in the membrane. Only a small proportion diffuses into the electrodes. Consequently, it is recommended to critically evaluate the obtained results, especially when detecting low amounts of NH3 and it is also necessary to examine the components of the synthesis system for the presence of NH3 before proceeding with further experiments. Otherwise, this is likely to result in subsequent experiments being influenced by the preceding one, thus affecting reproducibility and reliability.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/membranes15050149/s1, Figure S1: Temperature effect on desorption; Figure S2: Time effect on desorption; Figure S3: Impedance spectra and fits of T1, ratio 2:1; Table S1: Elements of the impedance spectra of T1 of the ratio 2:1; Figure S4: Impedance spectra and fits of T1, ratio 1:1; Table S2: Elements of the impedance spectra of T1 of the ratio 1:1; Figure S5: Impedance spectra and fits of T2, ratio 1:1; Table S3: Elements of the impedance spectra of T2 of the ratio 1:1.

Author Contributions

D.S.: Conceptualization, Formal Analysis, Investigation, Methodology, and Writing—Original draft preparation. A.G.: Formal Analysis, Funding acquisition, Investigation, Reviewing and Editing K.W.: Formal Analysis, Reviewing and Editing M.M.: Funding acquisition, Reviewing and Editing U.R.: Supervision, Reviewing R.P.: Supervision, Reviewing All authors have read and agreed to the published version of the manuscript.

Funding

This work was financially supported as part of the European Union’s Horizon 2020 research and innovation program under the call H2020-LC-SC3-2020-RES-RIA. TELEGRAM project grant agreement no. 101006941.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

The data of this study are available from the corresponding author upon reasonable request.

Conflicts of Interest

Authors Dominik Sachse, Andreas Glüsen, Klaus Wippermann, Martin Müller, Uwe Rau and Ralf Peters were employed by the company Forschungszentrum Jülich GmbH. The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
eNRRElectrochemical nitrogen reduction reaction
MEAMembrane electrode assembly
PTLPorous transport layer
HERHydrogen evolution reaction

References

  1. Xue, Z.; Zhang, X.; Qin, J.; Liu, R. High-throughput identification of high activity and selectivity transition metal single-atom catalysts for nitrogen reduction. Nano Energy 2021, 80, 105527. [Google Scholar] [CrossRef]
  2. Suryanto, B.H.R.; Du, H.L.; Wang, D.; Chen, J.; Simonov, A.N.; MacFarlane, D.R. Challenges and prospects in the catalysis of electroreduction of nitrogen to ammonia. Nat. Catal. 2019, 2, 290–296. [Google Scholar] [CrossRef]
  3. Schlögl, R. Catalytic synthesis of ammonia—A “never-ending story”? Angew. Chem. 2003, 42, 2004–2008. [Google Scholar] [CrossRef] [PubMed]
  4. Tang, C.; Qiao, S.Z. How to explore ambient electrocatalytic nitrogen reduction reliably and insightfully. Chem. Soc. Rev. 2019, 48, 3166–3180. [Google Scholar] [CrossRef] [PubMed]
  5. Smil, V. Detonator of the population explosion. Nature 1999, 400, 415. [Google Scholar] [CrossRef]
  6. Erisman, J.W.; Sutton, M.A.; Galloway, J.; Klimont, Z.; Winiwarter, W. How a century of ammonia synthesis changed the world. Nat. Geosci. 2008, 1, 636–639. [Google Scholar] [CrossRef]
  7. Hu, L.; Khaniya, A.; Wang, J.; Chen, G.; Kaden, W.E.; Feng, X. Ambient Electrochemical Ammonia Synthesis with High Selectivity on Fe/Fe Oxide Catalyst. ACS Catal. 2018, 8, 9312–9319. [Google Scholar] [CrossRef]
  8. Chanda, D.; Xing, R.; Xu, T.; Liu, Q.; Luo, Y.; Liu, S.; Tufa, R.A.; Dolla, T.H.; Montini, T.; Sun, X. Electrochemical nitrogen reduction: Recent progress and prospects. Chem. Commun. 2021, 57, 7335–7349. [Google Scholar] [CrossRef]
  9. Iriawan, H.; Andersen, S.Z.; Zhang, X.; Comer, B.M.; Barrio, J.; Chen, P.; Medford, A.J.; Stephens, I.E.L.; Chorkendorff, I.; Shao-Horn, Y. Methods for nitrogen activation by reduction and oxidation. Nat. Rev. Methods Prim. 2021, 1, 56. [Google Scholar] [CrossRef]
  10. van der Ham, C.J.M.; Koper, M.T.M.; Hetterscheid, D.G.H. Challenges in reduction of dinitrogen by proton and electron transfer. Chem. Soc. Rev. 2014, 43, 5183–5191. [Google Scholar] [CrossRef]
  11. Li, K.; Andersen, S.Z.; Statt, M.J.; Saccoccio, M.; Bukas, V.J.; Krempl, K.; Sažinas, R.; Pedersen, J.B.; Shadravan, V.; Zhou, Y.; et al. Enhancement of lithium-mediated ammonia synthesis by addition of oxygen. Science 2021, 374, 1593–1597. [Google Scholar] [CrossRef] [PubMed]
  12. Shen, H.; Choi, C.; Masa, J.; Li, X.; Qiu, J.; Jung, Y.; Sun, Z. Electrochemical ammonia synthesis: Mechanistic understanding and catalyst design. Chem 2021, 7, 1708–1754. [Google Scholar] [CrossRef]
  13. Wu, T.; Fan, W.; Zhang, Y.; Zhang, F. Electrochemical synthesis of ammonia: Progress and challenges. Mater. Today Phys. 2021, 16, 100310. [Google Scholar] [CrossRef]
  14. Rafiqul, I.; Weber, C.; Lehmann, B.; Voss, A. Energy efficiency improvements in ammonia production—Perspectives and uncertainties. Energy 2005, 30, 2487–2504. [Google Scholar] [CrossRef]
  15. Xu, T.; Liang, J.; Li, S.; Xu, Z.; Yue, L.; Li, T.; Luo, Y.; Liu, Q.; Shi, X.; Asiri, A.M.; et al. Recent Advances in Nonprecious Metal Oxide Electrocatalysts and Photocatalysts for N 2 Reduction Reaction under Ambient Condition. Small Sci. 2021, 1, 2000069. [Google Scholar] [CrossRef]
  16. Liu, D.; Chen, M.; Du, X.; Ai, H.; Lo, K.H.; Wang, S.; Chen, S.; Xing, G.; Wang, X.; Pan, H. Development of Electrocatalysts for Efficient Nitrogen Reduction Reaction under Ambient Condition. Adv. Funct. Mater. 2021, 31, 2008983. [Google Scholar] [CrossRef]
  17. Andersen, S.Z.; Čolić, V.; Yang, S.; Schwalbe, J.A.; Nielander, A.C.; McEnaney, J.M.; Enemark-Rasmussen, K.; Baker, J.G.; Singh, A.R.; Rohr, B.A.; et al. A rigorous electrochemical ammonia synthesis protocol with quantitative isotope measurements. Nature 2019, 570, 504–508. [Google Scholar] [CrossRef]
  18. Kordali, V.; Kyriacou, G.; Lambrou, C. Electrochemical synthesis of ammonia at atmospheric pressure and low temperature in a solid polymer electrolyte cell. Chem. Commun. 2000, 1673–1674. [Google Scholar] [CrossRef]
  19. Kumari, S.; Pishgar, S.; Schwarting, M.E.; Paxton, W.F.; Spurgeon, J.M. Synergistic plasma-assisted electrochemical reduction of nitrogen to ammonia. Chem. Commun. 2018, 54, 13347–13350. [Google Scholar] [CrossRef]
  20. Yang, X.; Nash, J.; Anibal, J.; Dunwell, M.; Kattel, S.; Stavitski, E.; Attenkofer, K.; Chen, J.G.; Yan, Y.; Xu, B. Mechanistic Insights into Electrochemical Nitrogen Reduction Reaction on Vanadium Nitride Nanoparticles. J. Am. Chem. Soc. 2018, 140, 13387–13391. [Google Scholar] [CrossRef]
  21. Lan, R.; Irvine, J.T.S.; Tao, S. Synthesis of ammonia directly from air and water at ambient temperature and pressure. Sci. Rep. 2013, 3, 1145. [Google Scholar] [CrossRef] [PubMed]
  22. Leonardi, M.; Tranchida, G.; Corso, R.; Milazzo, R.G.; Lombardo, S.A.; Privitera, S.M.S. Role of the Membrane Transport Mechanism in Electrochemical Nitrogen Reduction Experiments. Membranes 2022, 12, 969. [Google Scholar] [CrossRef] [PubMed]
  23. Liu, H.; Guijarro, N.; Luo, J. The pitfalls in electrocatalytic nitrogen reduction for ammonia synthesis. J. Energy Chem. 2021, 61, 149–154. [Google Scholar] [CrossRef]
  24. Hanifpour, F.; Sveinbjörnsson, A.; Canales, C.P.; Skúlason, E.; Flosadóttir, H.D. Preparation of Nafion Membranes for Reproducible Ammonia Quantification in Nitrogen Reduction Reaction Experiments. Angew. Chem. 2020, 59, 22938–22942. [Google Scholar] [CrossRef]
  25. Cai, X.; Iriawan, H.; Yang, F.; Luo, L.; Shen, S.; Shao-Horn, Y.; Zhang, J. Interaction of Ammonia with Nafion and Electrolyte in Electrocatalytic Nitrogen Reduction Study. J. Phys. Chem. Lett. 2021, 12, 6861–6866. [Google Scholar] [CrossRef]
  26. Hongsirikarn, K.; Goodwin, J.G.; Greenway, S.; Creager, S. Influence of ammonia on the conductivity of Nafion membranes. J. Power Sources 2010, 195, 30–38. [Google Scholar] [CrossRef]
  27. Ren, Y.; Yu, C.; Tan, X.; Han, X.; Huang, H.; Huang, H.; Qiu, J. Is It Appropriate to Use the Nafion Membrane in Electrocatalytic N 2 Reduction? Small Methods 2019, 3, 1900474. [Google Scholar] [CrossRef]
  28. Yu, T.H.; Sha, Y.; Liu, W.G.; Merinov, B.V.; Shirvanian, P.; Goddard, W.A. Mechanism for degradation of Nafion in PEM fuel cells from quantum mechanics calculations. J. Am. Chem. Soc. 2011, 133, 19857–19863. [Google Scholar] [CrossRef]
  29. Ito, H.; Maeda, T.; Nakano, A.; Takenaka, H. Properties of Nafion membranes under PEM water electrolysis conditions. Int. J. Hydrogen Energy 2011, 36, 10527–10540. [Google Scholar] [CrossRef]
  30. Jalani, N.H.; Datta, R. The effect of equivalent weight, temperature, cationic forms, sorbates, and nanoinorganic additives on the sorption behavior of Nafion®. J. Membr. Sci. 2005, 264, 167–175. [Google Scholar] [CrossRef]
  31. Zhao, Y.; Wu, F.; Miao, Y.; Zhou, C.; Xu, N.; Shi, R.; Wu, L.Z.; Tang, J.; Zhang, T. Revealing Ammonia Quantification Minefield in Photo/Electrocatalysis. Angew. Chem. 2021, 60, 21728–21731. [Google Scholar] [CrossRef] [PubMed]
  32. Li, L.; Tang, C.; Xia, B.; Jin, H.; Zheng, Y.; Qiao, S.Z. Two-Dimensional Mosaic Bismuth Nanosheets for Highly Selective Ambient Electrocatalytic Nitrogen Reduction. ACS Catal. 2019, 9, 2902–2908. [Google Scholar] [CrossRef]
  33. Shiva Kumar, S.; Himabindu, V. Hydrogen production by PEM water electrolysis—A review. Mater. Sci. Energy Technol. 2019, 2, 442–454. [Google Scholar] [CrossRef]
  34. Litster, S.; McLean, G. PEM fuel cell electrodes. J. Power Sources 2004, 130, 61–76. [Google Scholar] [CrossRef]
  35. Halseid, R.; Vie, P.J.S.; Tunold, R. Influence of Ammonium on Conductivity and Water Content of Nafion 117 Membranes; IOPscience: Bristol, UK, 2004. [Google Scholar]
  36. Morris, D.R.; Sun, X. Water–sorption and transport properties of Nafion 117 H. J. Appl. Polym. Sci. 1993, 50, 1445–1452. [Google Scholar] [CrossRef]
  37. Carmo, M.; Fritz, D.L.; Mergel, J.; Stolten, D. A comprehensive review on PEM water electrolysis. Int. J. Hydrogen Energy 2013, 38, 4901–4934. [Google Scholar] [CrossRef]
  38. Araujo, R.B.; Edvinsson, T. Supervised AI and Deep Neural Networks to Evaluate High-Entropy Alloys as Reduction Catalysts in Aqueous Environments. ACS Catal. 2024, 14, 3742–3755. [Google Scholar] [CrossRef]
Figure 1. Nafion structural formula, adapted from ref. [28] and a schematic illustration of the microstructure of Nafion.
Figure 1. Nafion structural formula, adapted from ref. [28] and a schematic illustration of the microstructure of Nafion.
Membranes 15 00149 g001
Figure 2. An Illustration of the ion exchange process and the NH4+-form of Nafion.
Figure 2. An Illustration of the ion exchange process and the NH4+-form of Nafion.
Membranes 15 00149 g002
Figure 3. Design of the electrochemical MEA cell and their compounds.
Figure 3. Design of the electrochemical MEA cell and their compounds.
Membranes 15 00149 g003
Figure 4. Schematic illustration of the test bench. H2O is supplied and O2 is produced at the anode. NH3 is expelled from the membrane and H2 is produced at the cathode. The coloring of the chemicals is done after the CPK color model.
Figure 4. Schematic illustration of the test bench. H2O is supplied and O2 is produced at the anode. NH3 is expelled from the membrane and H2 is produced at the cathode. The coloring of the chemicals is done after the CPK color model.
Membranes 15 00149 g004
Figure 5. Deviation of the ion exchange for two different ratios of NH4+ vs. H+ (bright colors). The y-axis displays the quantity of NH4+ remaining in the solution. The average of both proportion is indicated by the red and blue bar.
Figure 5. Deviation of the ion exchange for two different ratios of NH4+ vs. H+ (bright colors). The y-axis displays the quantity of NH4+ remaining in the solution. The average of both proportion is indicated by the red and blue bar.
Membranes 15 00149 g005
Figure 6. Equilibrium constants of the different ratios of NH4+ vs. H+ (red squares) and their corresponding error bars. The average value of Keq is shown as the blue line. The colored area is the error of the average value. The value of the ratio 2:1 is not considered for the average value.
Figure 6. Equilibrium constants of the different ratios of NH4+ vs. H+ (red squares) and their corresponding error bars. The average value of Keq is shown as the blue line. The colored area is the error of the average value. The value of the ratio 2:1 is not considered for the average value.
Membranes 15 00149 g006
Figure 7. The detected and measured quantities of NH3/ NH 4 + are presented. In red the quantity of NH 4 + that remained in the solution is represented and in green the initial quantity of NH 4 + that was exchanged into the membrane. The blue bar presents the sum of NH3 that was driven out from the membrane. In total the membrane was placed three times in a fresh H2SO4 solution, because an equilibrium of NH3 is established between the membrane and the solution, thereby preventing further desorption of NH3. These quantities are referred as first to third drag-out, depicted as the bright blue bars.
Figure 7. The detected and measured quantities of NH3/ NH 4 + are presented. In red the quantity of NH 4 + that remained in the solution is represented and in green the initial quantity of NH 4 + that was exchanged into the membrane. The blue bar presents the sum of NH3 that was driven out from the membrane. In total the membrane was placed three times in a fresh H2SO4 solution, because an equilibrium of NH3 is established between the membrane and the solution, thereby preventing further desorption of NH3. These quantities are referred as first to third drag-out, depicted as the bright blue bars.
Membranes 15 00149 g007
Figure 8. Expelled amount of NH3 of the 2:1 ratio, a logarithmic scale is used. The red color represents the measurement protocol of the first run and the blue of the second run. The applied potentials/current densities are written in black, while the measured potentials/current densities are written in blue.
Figure 8. Expelled amount of NH3 of the 2:1 ratio, a logarithmic scale is used. The red color represents the measurement protocol of the first run and the blue of the second run. The applied potentials/current densities are written in black, while the measured potentials/current densities are written in blue.
Membranes 15 00149 g008
Figure 9. Expelled amount of NH3 of the 1:1 ratio, a logarithmic scale is used. The red color represents the measurement protocol of the first run, the blue the second, and the green the third run. The applied potentials/current densities are written in black, while the the measured potentials/current densities are written in blue.
Figure 9. Expelled amount of NH3 of the 1:1 ratio, a logarithmic scale is used. The red color represents the measurement protocol of the first run, the blue the second, and the green the third run. The applied potentials/current densities are written in black, while the the measured potentials/current densities are written in blue.
Membranes 15 00149 g009
Figure 10. Comparison and ratio of the expelled amount of NH3 (green bars) compared to the initial amount of NH3 in the membrane (red bars). Green dots refer to the ratio of the expelled amount to the initial amount in the entire membrane while blue dots refer to the ratio of the expelled amount to the initial amount in the active area of the membrane only. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Figure 10. Comparison and ratio of the expelled amount of NH3 (green bars) compared to the initial amount of NH3 in the membrane (red bars). Green dots refer to the ratio of the expelled amount to the initial amount in the entire membrane while blue dots refer to the ratio of the expelled amount to the initial amount in the active area of the membrane only. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Membranes 15 00149 g010
Figure 11. Galvanostatic experiments for both ratios 2:1 and 1:1 NH4+ vs. H+ at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Figure 11. Galvanostatic experiments for both ratios 2:1 and 1:1 NH4+ vs. H+ at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Membranes 15 00149 g011
Figure 12. Polarization curves of the trials for both ratios 2:1 and 1:1 NH4+ vs. H+ at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Figure 12. Polarization curves of the trials for both ratios 2:1 and 1:1 NH4+ vs. H+ at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Membranes 15 00149 g012
Figure 13. Impedance spectra of the trials and their runs at 1.5 V at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Figure 13. Impedance spectra of the trials and their runs at 1.5 V at room temperature. (a) Ratio of 2:1 NH4+ vs. H+ and (b) ratio of 1:1 NH4+ vs. H+.
Membranes 15 00149 g013
Figure 14. (a) Impedance spectra of T2 of the ratio 2:1 NH4+ vs. H+ with their corresponding fits at 1.5 V and (b) the Randles equivalent circuit used for fitting.
Figure 14. (a) Impedance spectra of T2 of the ratio 2:1 NH4+ vs. H+ with their corresponding fits at 1.5 V and (b) the Randles equivalent circuit used for fitting.
Membranes 15 00149 g014
Figure 15. Expelled amount of NH3 during the applied current density and in the dead-voltage state. (a) Desorption 1. Run and (b) Desorption 2. Run.
Figure 15. Expelled amount of NH3 during the applied current density and in the dead-voltage state. (a) Desorption 1. Run and (b) Desorption 2. Run.
Membranes 15 00149 g015
Figure 16. Detected amount of NH4+ remaining in the cell components, a logarithmic scale is chosen to show small amounts present in some components.
Figure 16. Detected amount of NH4+ remaining in the cell components, a logarithmic scale is chosen to show small amounts present in some components.
Membranes 15 00149 g016
Figure 17. NH3 expelled electrochemical (red) and detected amount of NH3 expelled from the cell components. A logarithmic scale is chosen to show small amounts present in some components.
Figure 17. NH3 expelled electrochemical (red) and detected amount of NH3 expelled from the cell components. A logarithmic scale is chosen to show small amounts present in some components.
Membranes 15 00149 g017
Figure 18. NH3 expelled electrochemical (red and blue bar) and the total amount of NH3 that was found, electrochemical plus the quantity which were expelled afterwards in the H2SO4 solutions from the cell components (dark red and blue).
Figure 18. NH3 expelled electrochemical (red and blue bar) and the total amount of NH3 that was found, electrochemical plus the quantity which were expelled afterwards in the H2SO4 solutions from the cell components (dark red and blue).
Membranes 15 00149 g018
Table 1. Ion exchange concentrations.
Table 1. Ion exchange concentrations.
NH4+ vs. H+n(NH4+)c(NH4+) β (NH4+)m((NH4)2SO4)
0.5:1 201.5   μ mol 0.008 mol L −1144  m g   L −113 m g
0.8:1 322.4   μ mol 0.013 mol L −1235  m g   L −122 m g
1:1403  μ mol 0.016 mol L −1289  m g   L −126 m g
1.5:1 604.5   μ mol 0.024 mol L −1433  m g   L −140 m g
2:1806 μ mol 0.032 mol L −1577 m g   L −152 m g
Table 2. Elements of the impedance spectra of T2 of the ratio 2:1.
Table 2. Elements of the impedance spectra of T2 of the ratio 2:1.
R Ω [ Ω cm2] R C T [ Ω cm2] W R [ Ω cm2] W T [s] W P CPE T [ Ω −1 s−1 cm−2] CPE P
0.988 ± 0.025 0 0.231 ± 0.063 0 2.81 ± 0.38 0 1.2 ± 0.2 0 0.52 ± 0.02 0 1.88 ± 1.88 0 0.6 ± 0.1 0
0.375 ± 0.031 0 0.119 ± 0.063 0 1.56 ± 0.25 0 0.67 ± 0.08 0 0.54 ± 0.03 0 3.13 ± 5 0 0.54 ± 0.05 0
0.331 ± 0.038 0 0.119 ± 0.056 0 1.44 ± 0.13 0 0.60 ± 0.04 0 0.56 ± 0.02 0 2.5 ± 3.1 0 0.6 ± 0.2 0
Table 3. Σ ntot is the sum of the quantity of NH3, that was expelled during the runs in the dead-voltage states. V1 represents the first 10 time interval of 0 V, V2 the second, and V3 the third. χ is defined as the percentage of NH 4 + removed without applying a potential, relative to the amount removed at a current density of 0.8 A cm−2 for ntot. In addition, it represents the percentage of NH 4 + removed without applying a potential for the various time intervals, in relation to the total amount of NH 4 + removed without the application of a potential.
Table 3. Σ ntot is the sum of the quantity of NH3, that was expelled during the runs in the dead-voltage states. V1 represents the first 10 time interval of 0 V, V2 the second, and V3 the third. χ is defined as the percentage of NH 4 + removed without applying a potential, relative to the amount removed at a current density of 0.8 A cm−2 for ntot. In addition, it represents the percentage of NH 4 + removed without applying a potential for the various time intervals, in relation to the total amount of NH 4 + removed without the application of a potential.
1. Run2. Run
n [ μ mol] χ [%] n [ μ mol] χ [%]
Σ ntot 12.45 ± 0.60 0 25.30 ± 1.22 0 1.37 ± 0.60 0 18.57 ± 8.16 0
V1 8.38 ± 0.20 0 67.31 ± 3.62 0 0.98 ± 0.20 0 71.15 ± 34.46 0
V2 2.88 ± 0.20 0 23.15 ± 1.96 0 0.35 ± 0.20 0 25.27 ± 18.35 0
V3 1.19 ± 0.20 0 9.54 ± 1.67 0 0.05 ± 0.20 0 3.57 ± 15.70 0
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Sachse, D.; Glüsen, A.; Wippermann, K.; Müller, M.; Rau, U.; Peters, R. The Ammonia Adsorption and Desorption Behavior of Nafion. Membranes 2025, 15, 149. https://doi.org/10.3390/membranes15050149

AMA Style

Sachse D, Glüsen A, Wippermann K, Müller M, Rau U, Peters R. The Ammonia Adsorption and Desorption Behavior of Nafion. Membranes. 2025; 15(5):149. https://doi.org/10.3390/membranes15050149

Chicago/Turabian Style

Sachse, Dominik, Andreas Glüsen, Klaus Wippermann, Martin Müller, Uwe Rau, and Ralf Peters. 2025. "The Ammonia Adsorption and Desorption Behavior of Nafion" Membranes 15, no. 5: 149. https://doi.org/10.3390/membranes15050149

APA Style

Sachse, D., Glüsen, A., Wippermann, K., Müller, M., Rau, U., & Peters, R. (2025). The Ammonia Adsorption and Desorption Behavior of Nafion. Membranes, 15(5), 149. https://doi.org/10.3390/membranes15050149

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.