Editorial

Implant Stability in Regenerated Bone

Department of Medicine, Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, Via Allende, 84081 Salerno, Italy
*
Authors to whom correspondence should be addressed.
Appl. Sci. 2023, 13(22), 12161; https://doi.org/10.3390/app132212161
Submission received: 17 October 2023 / Accepted: 3 November 2023 / Published: 9 November 2023
(This article belongs to the Special Issue Advanced Dental Materials and Appliances)

1. Introduction

Bone regeneration is a surgical therapy that is increasingly being used for implant placement in functional patient rehabilitation. Since the first biological and technical description of the procedure by Dahlin et al. [1], several techniques have been proposed for bone augmentation. The choice of the correct technique varies depending on the specific clinical case, the typology of bone defect, and other variables because therapeutic choices need to be individualized [2,3,4,5]. Despite the different techniques proposed in the literature, the aim has always been an increase in hard tissues, which are not enough at baseline, to allow implant placement. Nowadays, this procedure is planned on computer software to have a digital work-flow, with precise and predictable results [6].

2. Implant Stability in Regenerated Bone

After the placement in the bone, the implant requires stability, an essential factor for success [7]. This will be mechanical initially and biological stability later [8]. Primary and secondary stability, respectively, will allow the implant to be in situ at the time of insertion and subsequently loaded with the prosthesis on top of it, which will have a different time of healing in the maxilla and mandibular bone [9,10].
Good primary stability will certainly help the formation of secondary stability of the implant with bone, which will mature in direct contact with the implant surface, thus creating the conditions for osseointegration [11]. The factors that influence the achievement of good primary stability are certainly bone quantity and quality, surgical technique and implant design [12]. In particular, bone quality is the conditio sine qua non to achieve good bone-implant mechanical stability [13].
When an implant is placed in a native bone, the preliminary assessment of the bone quality, which will provide primary stability, depends on the anatomical site of insertion [14].
On the other hand, when the amount of bone is inadequate to place the implant, regenerative surgery is needed and the process changes.
A lot of studies have been conducted comparing different bone augmentation methods, in terms of bone substitutes, types of membranes, and accessory materials, all aimed at finding the best result in terms of gain and quality of reconstructed tissue [15,16].
A comparative study by Cucchi et al., for example, did not find statistically significant differences between bone augmentation using a non-resorbable membrane and a titanium mesh associated with resorbable membrane by histological analysis of bone tissue [17].
Different methods were used to assess the implant stability in the surrounding bone. Some of these methods are insertion torque and resonance frequency analysis. The latter, a non-invasive method, has been used both in studies of healed post-extractive bone and in cases of bone augmentation to assess implant stability at different times [18].
According to a study by Vallecillo-Rivas et al., the implant stability found in regenerated bone can be considered acceptable for prosthetic loading at 12 weeks after implant placement [19].
Although considered acceptable, implant stability values in regenerated bone are always lower than those in native bone, even if it is a valuable alternative in patients with bone tissue defects, as long as the waiting time for implant placement in regenerated bone is at least 6 months.
Therefore, more studies are needed to further investigate the quality of the regenerated bone tissue and the degree of stability the implant achieves in the tissue at different evaluation times.

Author Contributions

Conceptualization, M.C. and A.A.; methodology, M.C.; validation, M.C.; investigation, M.C. and A.A.; writing—original draft preparation, A.A.; writing—review and editing, M.C. and A.A.; visualization, M.C.; supervision, M.C. All authors have read and agreed to the published version of the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Dahlin, C.; Sennerby, L.; Lekholm, U.; Linde, A.; Nyman, S. Generation of New Bone around Titanium Implants Using a Membrane Technique: An Experimental Study in Rabbits. Int. J. Oral Maxillofac. Implants 1989, 4, 19–25. [Google Scholar] [PubMed]
  2. Caggiano, M.; D’Ambrosio, F.; Giordano, F.; Acerra, A.; Sammartino, P.; Iandolo, A. The “Sling” Technique for Horizontal Guided Bone Regeneration: A Retrospective Case Series. Appl. Sci. 2022, 12, 5889. [Google Scholar] [CrossRef]
  3. Urban, I.A.; Monje, A. Guided Bone Regeneration in Alveolar Bone Reconstruction. Oral Maxillofac. Surg. Clin. N. Am. 2019, 31, 331–338. [Google Scholar] [CrossRef] [PubMed]
  4. Giordano, F.; D’Ambrosio, F.; Acerra, A.; Scognamiglio, B.; Langone, M.; Caggiano, M. Bone Gain after Maxillary Sinus Lift: 5-Years Follow-up Evaluation of the Graft Stability. J. Osseointegration 2023, 15, 221–227. [Google Scholar] [CrossRef]
  5. Merli, M.; Mariotti, G.; Mazzoni, A.; Moscatelli, M.; Pagliaro, U.; Nieri, M. The Wafer Technique: Histomorphometric Results. Int. J. Periodontics Restor. Dent. 2020, 40, 815–823. [Google Scholar] [CrossRef] [PubMed]
  6. Caggiano, M.; Amato, A.; Acerra, A.; D’Ambrosio, F.; Martina, S. Evaluation of Deviations between Computer-Planned Implant Position and In Vivo Placement through 3D-Printed Guide: A CBCT Scan Analysis on Implant Inserted in Esthetic Area. Appl. Sci. 2022, 12, 5461. [Google Scholar] [CrossRef]
  7. Albrektsson, T.; Zarb, G.; Worthington, P.; Eriksson, A.R. The Long-Term Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success. Int. J. Oral Maxillofac. Implant. 1986, 1, 11–25. [Google Scholar]
  8. Javed, F.; Ahmed, H.B.; Crespi, R.; Romanos, G.E. Role of Primary Stability for Successful Osseointegration of Dental Implants: Factors of Influence and Evaluation. Interv. Med. Appl. Sci. 2013, 5, 162–167. [Google Scholar] [CrossRef] [PubMed]
  9. Pantaleo, G.; Acerra, A.; Giordano, F.; D’Ambrosio, F.; Langone, M.; Caggiano, M. Immediate Loading of Fixed Prostheses in Fully Edentulous Jaws: A 7-Year Follow-Up from a Single-Cohort Retrospective Study. Appl. Sci. 2022, 12, 12427. [Google Scholar] [CrossRef]
  10. Esposito, M.; Grusovin, M.G.; Polyzos, I.P.; Felice, P.; Worthington, H.V. Timing of Implant Placement after Tooth Extraction: Immediate, Immediate-Delayed or Delayed Implants? A Cochrane Systematic Review. Eur. J. Oral Implantol. 2010, 3, 189–205. [Google Scholar] [PubMed]
  11. Albrektsson, T.; Brånemark, P.I.; Hansson, H.A.; Lindström, J. Osseointegrated Titanium Implants. Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in Man. Acta Orthop. Scand. 1981, 52, 155–170. [Google Scholar] [CrossRef] [PubMed]
  12. Turkyilmaz, I.; McGlumphy, E.A. Influence of Bone Density on Implant Stability Parameters and Implant Success: A Retrospective Clinical Study. BMC Oral Health 2008, 8, 32. [Google Scholar] [CrossRef] [PubMed]
  13. Monje, A.; Suarez, F.; Garaicoa, C.A.; Monje, F.; Galindo-Moreno, P.; García-Nogales, A.; Wang, H.-L. Effect of Location on Primary Stability and Healing of Dental Implants. Implant Dent. 2014, 23, 69–73. [Google Scholar] [CrossRef] [PubMed]
  14. Misch, C.E. Bone Classification, Training Keys to Implant Success. Dent. Today 1989, 8, 39–44. [Google Scholar] [PubMed]
  15. Campana, M.D.; Aliberti, A.; Acerra, A.; Sammartino, P.; Dolce, P.; Sammartino, G.; Gasparro, R. The Effectiveness and Safety of Autologous Platelet Concentrates as Hemostatic Agents after Tooth Extraction in Patients on Anticoagulant Therapy: A Systematic Review of Randomized, Controlled Trials. J. Clin. Med. 2023, 12, 5342. [Google Scholar] [CrossRef] [PubMed]
  16. Cao, Y.-B.; Liu, C.; Pan, W.-L.; Tu, Y.; Li, C.-J.; Hua, C.-G. Research progress on the modification of guided bone regeneration membranes. Hua Xi Kou Qiang Yi Xue Za Zhi Huaxi Kouqiang Yixue Zazhi West China J. Stomatol. 2019, 37, 325–329. [Google Scholar] [CrossRef]
  17. Cucchi, A.; Sartori, M.; Parrilli, A.; Aldini, N.N.; Vignudelli, E.; Corinaldesi, G. Histological and Histomorphometric Analysis of Bone Tissue after Guided Bone Regeneration with Non-Resorbable Membranes vs Resorbable Membranes and Titanium Mesh. Clin. Implant Dent. Relat. Res. 2019, 21, 693–701. [Google Scholar] [CrossRef] [PubMed]
  18. Deli, G.; Petrone, V.; De Risi, V.; Tadic, D.; Zafiropoulos, G.-G. Longitudinal Implant Stability Measurements Based on Resonance Frequency Analysis after Placement in Healed or Regenerated Bone. J. Oral Implantol. 2014, 40, 438–447. [Google Scholar] [CrossRef] [PubMed]
  19. Vallecillo-Rivas, M.; Reyes-Botella, C.; Vallecillo, C.; Lisbona-González, M.J.; Vallecillo-Capilla, M.; Olmedo-Gaya, M.V. Comparison of Implant Stability between Regenerated and Non-Regenerated Bone. A Prospective Cohort Study. J. Clin. Med. 2021, 10, 3220. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Caggiano, M.; Acerra, A. Implant Stability in Regenerated Bone. Appl. Sci. 2023, 13, 12161. https://doi.org/10.3390/app132212161

AMA Style

Caggiano M, Acerra A. Implant Stability in Regenerated Bone. Applied Sciences. 2023; 13(22):12161. https://doi.org/10.3390/app132212161

Chicago/Turabian Style

Caggiano, Mario, and Alfonso Acerra. 2023. "Implant Stability in Regenerated Bone" Applied Sciences 13, no. 22: 12161. https://doi.org/10.3390/app132212161

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop