Development of an Automated Body Temperature Detection Platform for Face Recognition in Cattle with YOLO V3-Tiny Deep Learning and Infrared Thermal Imaging
Round 1
Reviewer 1 Report
Authors should mention why they chose YOLO as their deep learning model out of other models.
The references 15 and 16 are not very relevant to this study. Authors could have cited other papers to define AUC.
Authors should use subscripts and same letter case when using the terms in the text after and before equations such as Br, Bp ..
Authors should discuss their strategy in hyper parameter tuning. Also how did they make sure their model is well fitted (not over fitted or under fitted).
Some paragraphs are really short consisting of a sentence or two (page 3 for example). I suggest rewriting them so a paragraph can have at least 3 sentences.
Author Response
Dear Reviewer,
By on line submission our research article manuscript to Applied Sciences, our manuscript entitled, “Development of an automated body temperature detection platform for face recognition in cattle with YOLO V3-tiny deep learning and infrared thermal imaging”, for review. All the authors participating in the design, execution, and analysis of the paper and have approved the final version. This work has not been published in other journals or submitted to other periodicals for review. Hope you will find it acceptable for publication.
We deeply appreciate your consideration of our manuscript, and we look forward to receiving comments from you.
Sincerely yours,
Distinguished Professor
Tsair-Fwu Lee, Ph.D.
Medical Physics and Informatics Lab.
National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.
Author Response File: Author Response.pdf
Reviewer 2 Report
- The relevance of the study should be improved. Paragraphs 2 and 3 of the Introduction should be reversed. Also, the paragraph (lines 206-209) can be attributed to the Introduction.
- In addition to the description of the image capture system (lines 94-95), you can present a photo of it in Fig. 1.
- What is the spectral range of thermal imaging images? Is spectrum optimization possible?
- The paragraph (lines 206-209) can be moved to the Introduction.
- Lines 231-235 duplicate the information in lines 50-56.
- The phrase in the Conclusions " This system provides a rapid and convenient measurement solution for ranch managers." needs a more serious justification and continuation/specification.
Author Response
Dear Reviewer,
By on line submission our research article manuscript to Applied Sciences, our manuscript entitled, “Development of an automated body temperature detection platform for face recognition in cattle with YOLO V3-tiny deep learning and infrared thermal imaging”, for review. All the authors participating in the design, execution, and analysis of the paper and have approved the final version. This work has not been published in other journals or submitted to other periodicals for review. Hope you will find it acceptable for publication.
We deeply appreciate your consideration of our manuscript, and we look forward to receiving comments from you.
Sincerely yours,
Distinguished Professor
Tsair-Fwu Lee, Ph.D.
Medical Physics and Informatics Lab.
National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan.
Author Response File: Author Response.pdf
Round 2
Reviewer 1 Report
The authors addressed most of the comments. However, for some comments (on overfitting), they just responded in the rebuttal letter but changes were not made in the manuscript. Please address these comments in the manuscript.
Author Response
Response to Reviewer 1 Comments
Point 1: The authors addressed most of the comments. However, for some comments (on overfitting), they just responded in the rebuttal letter but changes were not made in the manuscript. Please address these comments in the manuscript.
Response 1: Thanks to Reviewer for the professional advice. We have addressed these comments in the manuscript. (yellow markers)
Author Response File: Author Response.pdf
This manuscript is a resubmission of an earlier submission. The following is a list of the peer review reports and author responses from that submission.