Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface
Abstract
1. Introduction
2. Materials and Methods
3. Results
4. Discussion
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Limones, A.; Molinero-Mourelle, P.; Azevedo, L.; Romeo-Rubio, M.; Correia, A.; Gómez-Polo, M. Zirconia-ceramic versus metal-ceramic posterior multiunit tooth-supported fixed dental prostheses: A systematic review and meta-analysis of randomized controlled trials. J. Am. Dent. Assoc. 2020, 151, 230–238. [Google Scholar] [CrossRef] [PubMed]
- Stawarczyk, B.; Keul, C.; Eichberger, M.; Figge, D.; Edelhoff, D.; Lümkemann, N. Three generations of zirconia: From veneered to monolithic. Part I. Quintessence Int. 2017, 48, 369–380. [Google Scholar] [PubMed]
- Pontevedra, P.; Lopez-Suarez, C.; Pelaez, J.; Garcia-Serdio, S.; Suarez, M.J. Prospective Clinical Evaluation of Posterior Monolithic Zirconia Fixed Partial Dentures Using a Complete Digital Workflow: Two-Year Follow-Up. J. Prosthodont. 2021, 30, 298–304. [Google Scholar] [CrossRef] [PubMed]
- Habibi, Y.; Dawid, M.T.; Waldecker, M.; Rammelsberg, P.; Bömicke, W. Three-year clinical performance of monolithic and partially veneered zirconia ceramic fixed partial dentures. J. Esthet. Restor. Dent. 2020, 32, 395–402. [Google Scholar] [CrossRef] [PubMed]
- Koenig, V.; Wulfman, C.; Bekaert, S.; Dupont, N.; le Goff, S.; Eldafrawy, M.; Vanheusden, A.; Mainjot, A. Clinical behavior of second-generation zirconia monolithic posterior restorations: Two-year results of a prospective study with Ex vivo analyses including patients with clinical signs of bruxism. J. Dent. 2019, 91, 103229. [Google Scholar] [CrossRef] [PubMed]
- Rauch, A.; Pahncke, E.J.; Hahnel, S.F.; Schierz, O. Do monolithic zirconia restorations affect TMD signs and symptoms? Data from a prospective clinical trial after one year of observation. Int. J. Prosthodont. 2021. [Google Scholar] [CrossRef] [PubMed]
- Kern, M.; Thompson, V.P.; Beuer, F.; Frankenberger, R.; Kohal, R.J.; Kunzelmann, P.; Pospiech, P.; Reiss, B. All-Ceramics at A Glance, 3rd ed.; AG Keramik: Malsch, Germany, 2017. [Google Scholar]
- Bömicke, W.; Rammelsberg, P.; Stober, T.; Schmitter, M. Short-term prospective clinical evaluation of monolithic and partially veneered zirconia single crowns. J. Esthet. Restor. Dent. 2017, 29, 22–30. [Google Scholar] [CrossRef] [PubMed]
- Miura, S.; Yamauchi, S.; Kasahara, S.; Katsuda, Y.; Fujisawa, M.; Egusa, H. Clinical evaluation of monolithic zirconia crowns: A failure analysis of clinically obtained cases from a 3.5-year study. J. Prosthodont. Res. 2020. [Google Scholar] [CrossRef]
- Esquivel-Upshaw, J.F.; Kim, M.J.; Hsu, S.M.; Abdulhameed, N.; Jenkins, R.; Neal, D.; Ren, F.; Clark, A.E. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J. Dent. 2018, 68, 19–27. [Google Scholar] [CrossRef]
- Preis, V.; Grumser, K.; Schneider-Feyrer, S.; Behr, M.; Rosentritt, M. Cycle-dependent in vitro wear performance of dental ceramics after clinical surface treatments. J. Mech. Behav. Biomed. Mater. 2016, 53, 49–58. [Google Scholar] [CrossRef] [PubMed]
- Levartovsky, S.; Pilo, R.; Shadur, A.; Matalon, S.; Winocur, E. Complete rehabilitation of patients with bruxism by veneered and non-veneered zirconia restorations with an increased vertical dimension of occlusion: An observational case-series study. J. Prosthodont. Res. 2019, 63, 440–446. [Google Scholar] [CrossRef]
- Hansen, T.L.; Schriwer, C.; Øilo, M.; Gjengedal, H. Monolithic zirconia crowns in the aesthetic zone in heavy grinders with severe tooth wear—An observational case-series. J. Dent. 2018, 72, 14–20. [Google Scholar] [CrossRef]
- Lobbezoo, F.; Ahlberg, J.; Raphael, K.G.; Wetselaar, P.; Glaros, A.G.; Kato, T.; Santiago, V.; Winocur, E.; de Laat, A.; de Leeuw, R.; et al. International consensus on the assessment of bruxism: Report of a work in progress. J. Oral. Rehabil. 2018, 45, 837–844. [Google Scholar] [CrossRef] [PubMed]
Parameter | Outcome | |||
---|---|---|---|---|
Age (years) | mean 56.9 ± 13.1; min. 29; max. 80 | |||
Gender | 52.0% female | 48.0% male | ||
Units | 74.0% (3 units) | 16.0% (4 units) | 8.0% (5 units) | 2.0% (6 units) |
Veneering | 28.0% facial | 72.0% no veneering | ||
Material (manufacturer) | 62.0% Zenostar ZR translucent (Wieland, Pforzheim, Germany) | 20.0% Lava Plus (3M, Saint Paul, MN, USA) | 10.0% DD Bio ZX2 (Dental Direkt, Spenge, Germany) | 8.0% NexxZr T (Sagemax, Lindau, Germany) |
Cementation | 14.0% zinc oxide phosphate | 52.0% glass ionomer cement | 34.0% RelyX Unicem (3M, Saint Paul, MN, USA) |
Event | Units/Facial Veneering | Material | Cementation | Type of Event | Time of Event (Months) |
---|---|---|---|---|---|
I complication | 3/yes | Zenostar ZR translucent (Wieland, Pforzheim, Germany) | glass ionomer cement | technical, debonding | 12 |
II complication | 4/no | Zenostar ZR translucent (Wieland, Pforzheim, Germany) | glass ionomer cement | biological, symptomatic irreversible pulpitis | 12 |
III complication | 4/yes | Lava Plus (3M, Saint Paul, MN, USA) | glass ionomer cement | biological, asymptomatic apical periodontitis | 14 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Pahncke, E.; Hahnel, S.; Schierz, O.; Schmidt, M.B.; Schmutzler, A.; Rauch, A. Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Appl. Sci. 2021, 11, 4449. https://doi.org/10.3390/app11104449
Pahncke E, Hahnel S, Schierz O, Schmidt MB, Schmutzler A, Rauch A. Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Applied Sciences. 2021; 11(10):4449. https://doi.org/10.3390/app11104449
Chicago/Turabian StylePahncke, Elisabeth, Sebastian Hahnel, Oliver Schierz, Michael Benno Schmidt, Anne Schmutzler, and Angelika Rauch. 2021. "Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface" Applied Sciences 11, no. 10: 4449. https://doi.org/10.3390/app11104449
APA StylePahncke, E., Hahnel, S., Schierz, O., Schmidt, M. B., Schmutzler, A., & Rauch, A. (2021). Two-Year Longevity of Posterior Zirconia Multi-Unit Fixed Dental Prostheses with Monolithic Occlusal Surface. Applied Sciences, 11(10), 4449. https://doi.org/10.3390/app11104449