Article

Comparison of Computerized Cardiotocography Parameters between Male and Female Fetuses

by
Elena R. Magro-Malosso
1,
Giovanni Sisti
2,
Viola Seravalli
1,
Tomi T. Kanninen
3,
Martina Aldinucci
1 and
Mariarosaria Di Tommaso
1,*
1
Department of Health Science, Division of Pediatrics, Obstetrics and Gynecology Careggi Hospital, University of Florence, 50121 Florence, Italy
2
Department of Obstetrics and Gynecology, Lincoln Medical and Mental Health Center, Bronx, NY 10451, USA
3
Department of Obstetrics and Gynecology, Richmond University Medical Center, Staten Island, NY 10310, USA
*
Author to whom correspondence should be addressed.
Med. Sci. 2019, 7(3), 50; https://doi.org/10.3390/medsci7030050
Submission received: 18 February 2019 / Revised: 16 March 2019 / Accepted: 19 March 2019 / Published: 21 March 2019
(This article belongs to the Section Gynecology)

Abstract

Fetal sex has been identified as an important factor influencing pregnancy outcomes, but its impact on fetal heart rate (FHR) variability in uncomplicated pregnancies is still unclear. The objective of the study was to assess short-term variability (STV) and other computerized cardiotocography (cCTG) parameters in relation to fetal sex during fetal antepartum surveillance. We retrospective compared cCTG parameters of male and female fetuses in uncomplicated singleton pregnancies at term. In addition to univariate analysis, a multivariate analysis was performed taking into account maternal characteristics. A total of 689 cCTG recordings were analyzed: 335 from male fetuses and 354 from female fetuses. Analysis of cCTG results by fetal sex showed no significant difference in percentage of signal loss, number of contractions, movements, accelerations and decelerations, long-term variability (LTV), and STV at both uni-and multivariate analysis. There was a statistically significant difference for baseline FHR at the univariate analysis, which was not confirmed by a multivariate analysis. Our results suggest that fetal sex did not affect cCTG parameters in uncomplicated term singleton pregnancies, and therefore it does not need to be taken into account when interpreting cCTG in physiological conditions.
Keywords: fetal sex; cardiotocography; fetal heart rate; computerized analysis; uncomplicated pregnancy fetal sex; cardiotocography; fetal heart rate; computerized analysis; uncomplicated pregnancy

Share and Cite

MDPI and ACS Style

Magro-Malosso, E.R.; Sisti, G.; Seravalli, V.; Kanninen, T.T.; Aldinucci, M.; Di Tommaso, M. Comparison of Computerized Cardiotocography Parameters between Male and Female Fetuses. Med. Sci. 2019, 7, 50. https://doi.org/10.3390/medsci7030050

AMA Style

Magro-Malosso ER, Sisti G, Seravalli V, Kanninen TT, Aldinucci M, Di Tommaso M. Comparison of Computerized Cardiotocography Parameters between Male and Female Fetuses. Medical Sciences. 2019; 7(3):50. https://doi.org/10.3390/medsci7030050

Chicago/Turabian Style

Magro-Malosso, Elena R., Giovanni Sisti, Viola Seravalli, Tomi T. Kanninen, Martina Aldinucci, and Mariarosaria Di Tommaso. 2019. "Comparison of Computerized Cardiotocography Parameters between Male and Female Fetuses" Medical Sciences 7, no. 3: 50. https://doi.org/10.3390/medsci7030050

APA Style

Magro-Malosso, E. R., Sisti, G., Seravalli, V., Kanninen, T. T., Aldinucci, M., & Di Tommaso, M. (2019). Comparison of Computerized Cardiotocography Parameters between Male and Female Fetuses. Medical Sciences, 7(3), 50. https://doi.org/10.3390/medsci7030050

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop