Article
Peer-Review Record

Corrosion Study of Pipeline Steel under Stress at Different Cathodic Potentials by EIS

Metals 2019, 9(12), 1353; https://doi.org/10.3390/met9121353
by Ricardo Galván-Martínez 1, Ricardo Orozco-Cruz 1,*, Andrés Carmona-Hernández 1, Edgar Mejía-Sánchez 1, Miguel A. Morales-Cabrera 2 and Antonio Contreras 3
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Metals 2019, 9(12), 1353; https://doi.org/10.3390/met9121353
Submission received: 13 November 2019 / Revised: 9 December 2019 / Accepted: 11 December 2019 / Published: 16 December 2019
(This article belongs to the Special Issue Corrosion and Protection of Metals)

Round 1

Reviewer 1 Report

1) Which is the relation of CP and hydrogen generation?

2) CH exceeds CHCR, the activity of dislocations increases? Ananysis.

3) Explanation of fig. 2.

4) Detailed explanation for H diffusion for inter... and trans... cracking. 

5) H and localized plasticity? Ananysis. 

Author Response

Reviewer 1,

Please see the attachment

Regards,

Author Response File: Author Response.pdf

Reviewer 2 Report

Thanks for this well structured and understandable paper.

There are some tiny editorial remarks:

Please check correctness of grammar

for instance: line 83/84 should be changed to "...synthetic soil solutions called NS1, NS2, NS3, NS4 and NOVA have been used..."

Please use the same fonts (either serif or non serif) within the tables (see Tab. 1 and 2).

Tab.1: Enlarge Nb column a bit, so that "0.1" fits in one line

Fig. 3: Please brighten some of the darker photographs in order to increase the readability when printing in b/w.

Line 402 should be changed to "generating atomic H and increase the susceptibility..."

Author Response

Please see the attachment

 

Regards,

Author Response File: Author Response.pdf