Article

Intra- and Inter-Observer Reliability of ChatGPT-4o in Thyroid Nodule Ultrasound Feature Analysis Based on ACR TI-RADS: An Image-Based Study

by
Ziman Chen
1,*,
Nonhlanhla Chambara
2,
Shirley Yuk Wah Liu
3,
Tom Chi Man Chow
3,
Carol Man Sze Lai
3 and
Michael Tin Cheung Ying
1,*
1
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon 999077, Hong Kong
2
School of Healthcare Sciences, Cardiff University, Cardiff CF14 4XN, UK
3
Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories 999077, Hong Kong
*
Authors to whom correspondence should be addressed.
Diagnostics 2025, 15(20), 2617; https://doi.org/10.3390/diagnostics15202617
Submission received: 12 September 2025 / Revised: 10 October 2025 / Accepted: 15 October 2025 / Published: 17 October 2025
(This article belongs to the Section Medical Imaging and Theranostics)

Abstract

Background/Objectives: Advances in large language models like ChatGPT-4o have extended their use to medical image analysis. Accurate assessment of thyroid nodule ultrasound features using ACR TI-RADS is crucial for clinical practice. This study aims to evaluate ChatGPT-4o’s intra-observer consistency and its agreement with an expert in analyzing these features from ultrasound image assessments based on ACR TI-RADS. Methods: This cross-sectional study used ultrasound images from 100 thyroid nodules collected prospectively between May 2019 and August 2021. Ultrasound images were analyzed by ChatGPT-4o, following ACR TI-RADS guidelines, to assess features of thyroid nodule including composition, echogenicity, shape, margin, and echogenic foci. The analysis was repeated after one week to evaluate intra-observer reliability. The ultrasound images were also analyzed by another ultrasound expert for the evaluation of inter-observer reliability. Agreement was measured using Cohen’s Kappa coefficient, and concordance rates were calculated based on alignment with the expert’s reference classifications. Results: Intra-observer agreement for ChatGPT-4o was moderate for composition (Kappa = 0.449) and echogenic foci (Kappa = 0.404), with substantial agreement for echogenicity (Kappa = 0.795). Agreement was notably low for shape (Kappa = −0.051) and margin (Kappa = 0.154). Inter-observer agreement between ChatGPT-4o and the expert was generally low, with Kappa values ranging from −0.006 to 0.238, the highest being for echogenic foci. Overall concordance rates between ChatGPT-4o and expert evaluations ranged from 46.6% to 48.2%, with the highest for shape (65%) and the lowest for echogenicity (29%). Conclusions: ChatGPT-4o showed favorable consistency in assessing some thyroid nodule features in intra-observer analysis, but notable variability in others. Inter-observer comparisons with expert evaluations revealed generally low agreement across all features, despite acceptable concordance for certain imaging characteristics. While promising for specific ultrasound features, ChatGPT-4o’s consistency and accuracy still vary significantly compared to expert assessments.

1. Introduction

Recent advancements in large language models (LLMs), such as ChatGPT-4, have significantly expanded their applications from natural language processing to include computer vision and multimodal data analysis [1,2,3]. These models excel in processing and integrating multiscale and multisource data due to their sophisticated data processing capabilities and deep learning algorithms. This progress highlights their potential in the medical field, where LLMs are increasingly utilized to enhance diagnostic accuracy, operational efficiency, and the development of personalized treatment plans [4,5,6]. Their integration into healthcare settings has demonstrated substantial promise, improving the analysis of extensive medical data, identifying complex patterns, and supporting clinical decision-making.
Thyroid nodules are common in clinical practice, and their accurate assessment is essential for determining appropriate management strategies [7,8]. The American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) provides a standardized framework for evaluating the ultrasound features of thyroid nodules [9]. This system includes comprehensive lexicons and definitions for aspects such as composition, echogenicity, shape, margin, and echogenic foci. While ACR TI-RADS aims to enhance diagnostic consistency and facilitate risk stratification, its effectiveness depends heavily on clinician expertise and can be labor-intensive [10,11,12]. The rapid advancement of artificial intelligence (AI) has provided new solutions for the objective analysis of thyroid nodules, ranging from studies on computer-aided diagnosis tools to the more recent exploration of LLMs [13,14,15,16]. Although previous research has primarily focused on leveraging LLMs for generating standardized ultrasound reports and aiding thyroid nodule diagnosis [5,17,18], their direct application in ultrasound image analysis remains underexplored. Our previous study evaluated the feasibility of LLMs in classifying thyroid nodules as benign or malignant based on ultrasound images, demonstrating their potential in malignancy differentiation [19]. However, that study did not assess their ability to analyze specific ultrasound features according to TI-RADS criteria.
This study aims to evaluate the performance of ChatGPT-4o in analyzing thyroid nodule ultrasound images following the ACR TI-RADS guidelines. Specifically, the research investigates the intra-observer consistency of ChatGPT-4o through repeated analyses and measures inter-observer agreement by comparing the model’s assessments with those of an experienced expert, whose assessments were considered as a benchmark for reference. The analysis encompasses various ultrasound features, including composition, echogenicity, shape, margin, and echogenic foci. By exploring the practical utility of ChatGPT-4o in clinical settings, this study aims to assess its reliability in enhancing diagnostic accuracy and consistency in medical image analysis, potentially reducing observer variability and improving workflow efficiency in thyroid nodule evaluation.

2. Materials and Methods

2.1. Ethical Statement and Informed Consent

This cross-sectional clinical study was conducted following approval from our institution’s Institutional Review Board of The Hong Kong Polytechnic University (Protocol code HSEARS20190123004. Approval date: 30 January 2019) and adhered to the ethical principles outlined in the Declaration of Helsinki. Prior to participation, written informed consent was obtained from all patients involved in the study.

2.2. Image Dataset

The image dataset for this study consisted of thyroid nodule ultrasound images prospectively collected from patients who underwent ultrasound examinations and subsequent pathological diagnoses at our institution between May 2019 and August 2021. Inclusion criteria required nodules to have a maximum diameter greater than 1 cm and clear imaging quality, without measurement markers. A total of 100 thyroid nodules meeting these criteria were randomly selected. Ultrasound examinations were conducted using the Aixplorer Ultrasound Imaging System (SuperSonic Imagine, Aix-en-Provence, France) equipped with a linear transducer (SL15-4, 4–15 MHz). Both longitudinal and transverse views of each nodule were captured and preserved for subsequent analysis. All procedures were performed by a sonographer with at least three years of clinical experience.
The study workflow is illustrated in Figure 1.

2.3. Large Language Model Analysis

ChatGPT-4o, an advanced LLM developed by OpenAI (San Francisco, CA, USA), was used for this research. As one of the latest iterations, ChatGPT-4o was trained on datasets updated through June 2024. To ensure analytical consistency, all operations were performed by the same, trained operator. All model parameters were maintained at their default settings provided by the OpenAI platform, with no modifications.
Ultrasound images of thyroid nodules, including transverse and longitudinal views, were uploaded to ChatGPT-4o. These images were not published online to prevent their use in pre-training the model. The images were pre-processed by cropping to include only the nodule and its surrounding thyroid tissue, eliminating extraneous information that could interfere with the model’s analysis. This step was essential for focusing the model’s attention on relevant features.
To ensure methodological consistency, a single standardized prompt with identical wording was applied in all evaluations without modification across sessions. Specifically, the following prompt was used in the analyses:
“Please assume the role of an experienced ultrasound physician specializing in the diagnosis of thyroid nodules. I will present you with two ultrasound images of a thyroid nodule: the first image is a transverse view, and the second image is a longitudinal view. To ensure your focus is solely on analyzing the nodule’s characteristics, I have removed any non-essential information from the images that might interfere with your judgment, retaining only the nodule and its surrounding thyroid tissue. According to the ACR TI-RADS guidelines, please carefully evaluate and classify the ultrasound features of the nodule, considering the following aspects:
  • Composition: cystic or almost completely cystic, spongiform, mixed cystic and solid, solid or almost completely solid.
  • Echogenicity: anechoic, hyperechoic or isoechoic, hypoechoic, very hypoechoic.
  • Shape: taller-than-wide, wider-than-tall.
  • Margin: smooth, ill-defined, irregular or lobulated, extrathyroidal extension.
  • Echogenic foci: none, large comet-tail artifacts, macrocalcifications, peripheral or rim calcifications, punctate echogenic foci.”
ChatGPT-4o automatically analyzed the uploaded ultrasound images of thyroid nodules, assessing features according to the ACR TI-RADS guidelines. The evaluation encompassed various aspects, including composition (cystic, almost completely cystic, spongiform, mixed cystic and solid, solid or almost completely solid), echogenicity (anechoic, hyperechoic or isoechoic, hypoechoic, very hypoechoic), shape (taller-than-wide, wider-than-tall), margin (smooth, ill-defined, irregular or lobulated, extrathyroidal extension), and echogenic foci (none, large comet-tail artifacts, macrocalcifications, peripheral or rim calcifications, punctate echogenic foci). To maintain the independence of each analysis session, a new chat interface was used for each image set.
The operator repeated the analyses one week later using the same methodology to assess the intra-observer agreement of ChatGPT-4o.

2.4. Benchmark Evaluation

An expert in thyroid ultrasound, who is a board-certified radiologist with more than twenty years of clinical experience, independently reviewed all ultrasound images. The expert analyzed the images and classified the ultrasound features of the nodules based on the ACR TI-RADS guidelines, providing a benchmark for comparison. The expert’s evaluations were used as the benchmark for assessing the performance of ChatGPT-4o.

2.5. Statistical Analysis

The analysis of data was carried out with SPSS 26.0 (SPSS Inc., Chicago, IL, USA) and R statistical software, version 4.2.0 (R Foundation for Statistical Computing, Vienna, Austria). The intra-observer agreement of ChatGPT-4o’s analyses and the inter-observer agreement between ChatGPT-4o and the expert’s evaluations were assessed using Cohen’s Kappa coefficient. The Kappa statistic interpretation ranges were as follows: <0 (none agreement), 0–0.2 (slight agreement), 0.2–0.4 (fair agreement), 0.4–0.6 (moderate agreement), 0.6–0.8 (substantial agreement), and 0.8–1.0 (almost perfect agreement). Additionally, the concordance rate was calculated as the percentage of ultrasound features classified by ChatGPT-4o that were consistent with the expert’s reference classifications.

3. Results

3.1. Baseline Characteristics of the Image Dataset

The image dataset included a total of 100 thyroid nodules, of which 70 were classified as benign and 30 as malignant. The mean nodule size was 2.57 ± 1.23 cm. These nodules were derived from 98 patients, with a mean age of 54.26 ± 12.19 years, comprising 19 males and 79 females. A detailed summary of the baseline characteristics is provided in Table 1.

3.2. Intra- and Inter-Observer Agreement in Ultrasound Feature Assessment

The intra-observer agreement of ChatGPT-4o varied across different ultrasound feature categories. For composition, moderate agreement was observed (Kappa = 0.449). Echogenicity showed substantial agreement (Kappa = 0.795), while shape demonstrated no agreement (Kappa = −0.051). Margins exhibited slight agreement (Kappa = 0.154), and echogenic foci showed moderate agreement (Kappa = 0.404).
Similarly, the inter-observer agreement between ChatGPT-4o and the ultrasound expert varied across feature categories in both rounds. Composition demonstrated slight agreement (Kappa = 0.092 in the first round and 0.075 in the second round). Echogenicity showed no agreement (Kappa = −0.006 in the first round and −0.001 in the second round). Shape showed slight agreement (Kappa = 0.026 in the first round and 0.082 in the second round). Margins also exhibited slight agreement (Kappa = 0.096 in the first round and 0.092 in the second round). Echogenic foci demonstrated slight to fair agreement (Kappa = 0.142 in the first round and 0.238 in the second round).
The details of the intra- and inter-observer agreement are summarized in Table 2 and illustrated in Figure 2.

3.3. Concordance Rates Between ChatGPT-4o and Expert Evaluations

The overall concordance rate was 46.6% in the first round and 48.2% in the second round, as shown in Table 3 and Figure 3. For specific feature categories, composition exhibited moderate concordance, with rates of 56.0% in the first round and 55.0% in the second round. Echogenicity showed the lowest concordance, remaining at 29.0% in both rounds. Shape demonstrated the highest concordance among all categories, with rates of 59.0% in the first round and 65.0% in the second round. Margin had relatively low concordance rates, with 37.0% in the first round and 35.0% in the second round. Lastly, echogenic foci showed fair concordance, with rates of 52.0% in the first round and 57.0% in the second round.

4. Discussion

The present study provides a comprehensive evaluation of the intra- and inter-observer consistency of ChatGPT-4o in analyzing thyroid nodule ultrasound features from image-based assessments according to ACR TI-RADS. Our findings indicate that ChatGPT-4o demonstrates moderate to substantial intra-observer agreement for features such as echogenicity and composition, reflecting reliable consistency in repeated image analyses. However, certain features like shape and margin exhibited considerably lower intra-observer consistency, indicating variability in the model’s performance. Furthermore, inter-observer agreement between ChatGPT-4o and the expert was generally low, with slight agreement across most categories, though concordance rates were acceptable for some feature categories.
Several studies have investigated the consistency of LLMs, such as ChatGPT, in medical applications. However, most of these studies were focused on text-based analysis rather than direct image interpretation. Jiang et al. assessed ChatGPT-4’s ability to classify thyroid nodules based on the ACR TI-RADS using structured ultrasound report data [20]. Their findings showed moderate intra-observer agreement, with an intraclass correlation coefficient of 0.732, indicating that LLMs can reliably classify thyroid nodules using standardized medical reports. In contrast, our study observed varying levels of intra-observer agreement across different ultrasound features. For instance, composition demonstrated moderate agreement (Kappa = 0.449), while echogenicity showed substantial agreement (Kappa = 0.795). However, no agreement was observed for shape (Kappa = −0.051), and margins had only slight agreement (Kappa = 0.154). The discrepancy between our findings and those of Jiang et al. likely arises from the different scopes of each study. While Jiang et al. focused exclusively on TI-RADS classifications, our study conducted a more granular analysis of specific ultrasound features, revealing areas where LLM performance may require further refinement. Additionally, Jiang et al. evaluated ChatGPT’s capacity to interpret structured data, whereas our study tested its ability to directly analyze ultrasound images. This distinction highlights the current limitations of LLMs, such as ChatGPT, in image interpretation, underscoring the need for further advancements in this area, which is also consistent with findings by Brin et al. [21] and Reith TP et al. [22], who observed significant variation in ChatGPT-4’s performance across different imaging modalities and noted its current unreliability for standalone clinical use in radiology. This inconsistency was particularly evident in the assessment of shape and margin features, which showed notably lower reproducibility compared with other ultrasound characteristics. For shape assessment, we speculate that this may result from the model’s inability to perform geometric measurements and its limited spatial perception. Determining whether a nodule is taller-than-wide requires comparing vertical and horizontal dimensions, which is challenging without true geometric measurement capability and sufficient spatial perception [23]. For the margin feature, accurate delineation of the interface between the nodule and surrounding thyroid tissue is essential. However, current LLM-based vision models are not specifically designed for medical imaging tasks and may favor global texture or semantic cues over fine boundary delineation, making them prone to errors when margins are blurred or irregular [24].
Our study also revealed considerable variability in inter-observer agreement between ChatGPT-4o and an ultrasound expert across various ultrasound features. For example, composition showed slight agreement between the two observers (Kappa = 0.092 in the first round and 0.075 in the second), and no agreement was found for echogenicity (Kappa = −0.006 in the first round and −0.001 in the second). Shape exhibited slight agreement (Kappa = 0.026 in the first round and 0.082 in the second), and margins similarly displayed slight agreement (Kappa = 0.096 in the first round and 0.092 in the second). These results suggest that LLMs like ChatGPT still face significant challenges in consistently interpreting more nuanced ultrasound features when compared to expert evaluations. The lack of agreement in categories such as echogenicity and margins likely reflect the complexity of these features, which often require subtle clinical judgment that current LLMs may not yet fully replicate. Similar findings were reported by Sievert et al., who examined ChatGPT’s performance in risk stratifying thyroid nodules based on text-based ultrasound reports using ACR TI-RADS [25]. Their study found a low overall agreement of 42% between ChatGPT and human evaluators. In contrast, our study observed slightly higher concordance rates between ChatGPT-4o and expert evaluations, with overall agreement rates of 46.6% in the first round and 48.2% in the second. The discrepancies in inter-observer agreement found in both our study and Sievert et al.’s work emphasize the need for further optimization of LLMs for clinical use. While moderate concordance rates were observed for certain ultrasound features, such as shape and composition, the overall lack of reliability in interpreting features like echogenicity and margins indicates that LLMs are not yet ready for clinical decision-making based on image interpretation.
When assessing inter-observer agreement between ChatGPT-4o and the expert, ChatGPT-4o demonstrated moderate to high concordance rates across most ultrasound feature categories (35.0–65.0%). However, the observed low or even negligible Kappa values (0.026–0.238) indicate poor consistency, which seems counterintuitive at first glance. This discrepancy arises from fundamental differences in how concordance rate and Kappa statistics assess agreement [26,27]. While concordance rate simply quantifies the proportion of matching classifications without adjusting for chance agreement, Kappa accounts for expected agreement due to randomness, making it a more rigorous metric for true consistency. In present study, one major explanation for this phenomenon lies in the imbalance of feature classifications, which distorts the expected agreement calculation [28]. For example, in ChatGPT-4o’s analysis, 85–86% of nodules were classified as “solid or almost completely solid” in composition, and 97–98% as “hypoechoic” in echogenicity. Similarly, in expert evaluations, 83% of nodules were categorized as “wider-than-tall” in shape. Given the predominance of these categories, a high observed concordance can occur even under random conditions, artificially inflating the expected agreement and thereby diminishing the Kappa value. Since the majority of nodules belong to a single category, the expected agreement by chance is already high, leading to a disproportionately low Kappa value despite a moderate concordance rate. This finding underscores an important limitation: while concordance rate provides a straightforward measure of agreement, it may overestimate model reliability when class distributions are highly skewed. In contrast, Kappa offers a more stringent evaluation of consistency, which is essential for assessing the reproducibility of AI-driven diagnostic tools in clinical applications.
At present, LLM-based systems may be more appropriately positioned as supportive tools for education, training, or reducing observer variability rather than for direct clinical decision-making. In clinical practice, diagnostic tools are required to demonstrate high levels of reliability and safety prior to implementation. Misclassification of key nodule features could lead to inappropriate TI-RADS categorization, thereby influencing decisions regarding fine-needle aspiration or follow-up. Although ChatGPT-4o achieved moderate reproducibility for certain ultrasound features, the overall low inter-observer agreement with expert assessments indicates that the model is not yet suitable for independent clinical application. Clinical deployment will necessitate performance thresholds comparable to those of experienced radiologists, supported by large-scale validation, to ensure patient safety and diagnostic reliability.
Our study has limitations that warrant consideration. First, ChatGPT-4o is primarily designed for text-based tasks, and its ability to directly interpret images, particularly complex ultrasound features, is limited. Future research should emphasize the innovation and adaptation of LLMs specifically for medical image analysis to enhance their effectiveness in this domain. Second, the ultrasound images analyzed were derived from a controlled dataset, which may not fully capture the diversity of images encountered in clinical practice, potentially limiting the generalizability of our results. Third, although all images were acquired prospectively using standardized scanning protocols by experienced sonographers, variability in image quality may still have influenced the results. Factors such as contrast, spatial resolution, artifacts, and subtle differences in acquisition techniques can affect the visibility and interpretation of key ultrasound features. This limitation is particularly important for AI-driven image analysis, as models may be more sensitive to such variability than human observers. Future studies should therefore incorporate systematic assessments of these image quality factors to better understand their impact on model performance. Finally, although a single standardized prompt with identical wording was applied in all evaluations to minimize variability, different prompt phrasings could potentially influence model performance, and this remains an important aspect for future investigation.

5. Conclusions

While ChatGPT-4o demonstrates moderate to substantial intra-observer reproducibility in analyzing thyroid nodule ultrasound features from medical image assessments according to ACR TI-RADS, significant variability remains, particularly in features such as shape and margin. This inconsistency is observed not only in intra-observer analyses but also in inter-observer comparisons with expert assessments, where agreement was generally low. Despite its potential as a supportive tool for medical image analysis in clinical settings, ChatGPT-4o requires further refinement to improve its reliability across all ultrasound features. Enhancing the model’s performance through additional validation and optimization of its medical image interpretation capabilities is essential for its successful and consistent integration into clinical practice.

Author Contributions

Conception and design: Z.C.; Administrative support: Z.C. and M.T.C.Y.; Provision of study materials or patients: S.Y.W.L., T.C.M.C., C.M.S.L. and M.T.C.Y.; Collection and assembly of data: Z.C. and N.C.; Data analysis and interpretation: Z.C.; Manuscript writing: Z.C.; Final approval of manuscript: All authors. All authors have read and agreed to the published version of the manuscript.

Funding

This study was supported by the General Research Fund of Research Grants Council (Ref no. 15102524), and the research grants from the Hong Kong Polytechnic University (Ref nos. P0048845 and P0056738), with support to Z.C. from P0056738, and to M.T.C.Y. from both 15102524 and P0048845.

Institutional Review Board Statement

This study protocol was approved by the Institutional Review Board of The Hong Kong Polytechnic University (Protocol code HSEARS20190123004. Approval date: 30 January 2019) and complied with the tenets of the Helsinki Declaration.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available from the corresponding author upon reasonable request. Data is not publicly available due to privacy or ethical concerns.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Sultan, L.R.; Mohamed, M.K.; Andronikou, S. ChatGPT-4: A breakthrough in ultrasound image analysis. Radiol. Adv. 2024, 1, umae006. [Google Scholar] [CrossRef]
  2. Koga, S.; Du, W. From text to image: Challenges in integrating vision into ChatGPT for medical image interpretation. Neural Regen. Res. 2025, 20, 487–488. [Google Scholar] [CrossRef]
  3. Waisberg, E.; Ong, J.; Masalkhi, M.; Zaman, N.; Sarker, P.; Lee, A.G.; Tavakkoli, A. GPT-4 and medical image analysis: Strengths, weaknesses and future directions. J. Med. Artif. Intell. 2023, 6, 29. [Google Scholar] [CrossRef]
  4. Hayden, N.; Gilbert, S.; Poisson, L.M.; Griffith, B.; Klochko, C. Performance of GPT-4 with Vision on Text- and Image-based ACR Diagnostic Radiology In-Training Examination Questions. Radiology 2024, 312, e240153. [Google Scholar] [CrossRef]
  5. Xia, S.; Hua, Q.; Mei, Z.; Xu, W.; Lai, L.; Wei, M.; Qin, Y.; Luo, L.; Wang, C.; Huo, S.; et al. Clinical application potential of large language model: A study based on thyroid nodules. Endocrine 2024, 87, 206–213. [Google Scholar] [CrossRef] [PubMed]
  6. Wang, Z.; Zhang, Z.; Traverso, A.; Dekker, A.; Qian, L.; Sun, P. Assessing the role of GPT-4 in thyroid ultrasound diagnosis and treatment recommendations: Enhancing interpretability with a chain of thought approach. Quant Imaging Med. Surg. 2024, 14, 1602–1615. [Google Scholar] [CrossRef] [PubMed]
  7. Chen, D.W.; Lang, B.H.H.; McLeod, D.S.A.; Newbold, K.; Haymart, M.R. Thyroid cancer. Lancet 2023, 401, 1531–1544. [Google Scholar] [CrossRef]
  8. Wu, J.; Zhao, X.; Sun, J.; Cheng, C.; Yin, C.; Bai, R. The epidemic of thyroid cancer in China: Current trends and future prediction. Front. Oncol. 2022, 12, 932729. [Google Scholar] [CrossRef]
  9. Tessler, F.N.; Middleton, W.D.; Grant, E.G.; Hoang, J.K.; Berland, L.L.; Teefey, S.A.; Cronan, J.J.; Beland, M.D.; Desser, T.S.; Frates, M.C.; et al. ACR Thyroid Imaging, Reporting and Data System (TI-RADS): White Paper of the ACR TI-RADS Committee. J. Am. Coll. Radiol. 2017, 14, 587–595. [Google Scholar] [CrossRef] [PubMed]
  10. Özel Alper, M.D.; Türkyılmaz Mut Deniz, M.D.; Ağrıdağ Üçpınar Burçin, M.D.; Özdal Sayer Ayşe, M.D.; Yanç Uğur, M.D.; von Bodelschwingh Bade, M.D.; Gemalmaz Ali, M.D. Interobserver Variability of Ultrasound Features Based on American College of Radiology Thyroid Imaging Reporting and Data System Lexicon in American College of Radiology Thyroid Imaging Reporting and Data System System: A Single-Center Study with Radiologists and Radiology Residents. Ultrasound Q. 2021, 37, 324–328. [Google Scholar] [CrossRef]
  11. Itani, M.; Assaker, R.; Moshiri, M.; Dubinsky, T.J.; Dighe, M.K. Inter-observer Variability in the American College of Radiology Thyroid Imaging Reporting and Data System: In-Depth Analysis and Areas for Improvement. Ultrasound Med. Biol. 2019, 45, 461–470. [Google Scholar] [CrossRef]
  12. Hoang, J.K.; Middleton, W.D.; Farjat, A.E.; Teefey, S.A.; Abinanti, N.; Boschini, F.J.; Bronner, A.J.; Dahiya, N.; Hertzberg, B.S.; Newman, J.R.; et al. Interobserver Variability of Sonographic Features Used in the American College of Radiology Thyroid Imaging Reporting and Data System. AJR Am. J. Roentgenol. 2018, 211, 162–167. [Google Scholar] [CrossRef]
  13. Sant, V.R.; Radhachandran, A.; Ivezic, V.; Lee, D.T.; Livhits, M.J.; Wu, J.X.; Masamed, R.; Arnold, C.W.; Yeh, M.W.; Speier, W. From Bench-to-Bedside: How Artificial Intelligence is Changing Thyroid Nodule Diagnostics, a Systematic Review. J. Clin. Endocrinol. Metab. 2024, 109, 1684–1693. [Google Scholar] [CrossRef] [PubMed]
  14. Zhu, J.; Zhang, S.; Yu, R.; Liu, Z.; Gao, H.; Yue, B.; Liu, X.; Zheng, X.; Gao, M.; Wei, X. An efficient deep convolutional neural network model for visual localization and automatic diagnosis of thyroid nodules on ultrasound images. Quant. Imaging Med. Surg. 2021, 11, 1368–1380. [Google Scholar] [CrossRef] [PubMed]
  15. Liu, D.; Yang, K.; Zhang, C.; Xiao, D.; Zhao, Y. Fully-Automatic Detection and Diagnosis System for Thyroid Nodules Based on Ultrasound Video Sequences by Artificial Intelligence. J. Multidiscip. Healthc. 2024, 17, 1641–1651. [Google Scholar] [CrossRef] [PubMed]
  16. Zhang, Y.; Li, P.; Xu, L.; Zhang, X.; Ji, H.; Wang, Y. Large language models in thyroid diseases: Opportunities and challenges. EngMedicine 2025, 2, 100076. [Google Scholar] [CrossRef]
  17. Helvaci, B.C.; Hepsen, S.; Candemir, B.; Boz, O.; Durantas, H.; Houssein, M.; Cakal, E. Assessing the accuracy and reliability of ChatGPT’s medical responses about thyroid cancer. Int. J. Med. Inform. 2024, 191, 105593. [Google Scholar] [CrossRef]
  18. Loor-Torres, R.; Duran, M.; Toro-Tobon, D.; Chavez, M.M.; Ponce, O.; Jacome, C.S.; Torres, D.S.; Perneth, S.A.; Montori, V.; Golembiewski, E.; et al. A Systematic Review of Natural Language Processing Methods and Applications in Thyroidology. Mayo Clin. Proc. Digit. Health 2024, 2, 270–279. [Google Scholar] [CrossRef]
  19. Chen, Z.; Chambara, N.; Wu, C.; Lo, X.; Liu, S.Y.W.; Gunda, S.T.; Han, X.; Qu, J.; Chen, F.; Ying, M.T.C. Assessing the feasibility of ChatGPT-4o and Claude 3-Opus in thyroid nodule classification based on ultrasound images. Endocrine 2024, 87, 1041–1049. [Google Scholar] [CrossRef]
  20. Jiang, H.; Xia, S.; Yang, Y.; Xu, J.; Hua, Q.; Mei, Z.; Hou, Y.; Wei, M.; Lai, L.; Li, N.; et al. Transforming free-text radiology reports into structured reports using ChatGPT: A study on thyroid ultrasonography. Eur. J. Radiol. 2024, 175, 111458. [Google Scholar] [CrossRef]
  21. Brin, D.; Sorin, V.; Barash, Y.; Konen, E.; Glicksberg, B.S.; Nadkarni, G.N.; Klang, E. Assessing GPT-4 multimodal performance in radiological image analysis. Eur. Radiol. 2024, 35, 1959–1965. [Google Scholar] [CrossRef] [PubMed]
  22. Reith, T.P.; D’Alessandro, D.M.; D’Alessandro, M.P. Capability of multimodal large language models to interpret pediatric radiological images. Pediatr. Radiol. 2024, 54, 1729–1737. [Google Scholar] [CrossRef] [PubMed]
  23. Chen, B.; Xu, Z.; Kirmani, S.; Ichter, B.; Sadigh, D.; Guibas, L.; Xia, F. SpatialVLM: Endowing Vision-Language Models with Spatial Reasoning Capabilities. In Proceedings of the 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), Seattle, WA, USA, 17–21 June 2024; pp. 14455–14465. [Google Scholar]
  24. Eppel, S.; Bismut, M.; Faktor-Strugatski, A. Shape and texture recognition in large vision-language models. arXiv 2025, arXiv:250323062. [Google Scholar] [CrossRef]
  25. Sievert, M.; Conrad, O.; Mueller, S.K.; Rupp, R.; Balk, M.; Richter, D.; Mantsopoulos, K.; Iro, H.; Koch, M. Risk stratification of thyroid nodules: Assessing the suitability of ChatGPT for text-based analysis. Am. J. Otolaryngol. 2024, 45, 104144. [Google Scholar] [CrossRef]
  26. Feinstein, A.R.; Cicchetti, D.V. High agreement but low kappa: I. The problems of two paradoxes. J. Clin. Epidemiol. 1990, 43, 543–549. [Google Scholar] [CrossRef]
  27. McHugh, M.L. Interrater reliability: The kappa statistic. Biochem. Medica 2012, 22, 276–282. [Google Scholar] [CrossRef]
  28. Byrt, T.; Bishop, J.; Carlin, J.B. Bias, prevalence and kappa. J. Clin. Epidemiol. 1993, 46, 423–429. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Workflow for Thyroid Nodule Ultrasound Feature Analysis Using ChatGPT-4o and Expert Evaluation. Transverse and longitudinal sections of thyroid nodule ultrasound images are cropped and analyzed by ChatGPT-4o. Intra-observer agreement is assessed between two rounds of ChatGPT-4o analyses. Inter-observer agreement is evaluated by comparing ChatGPT-4o’s assessments with expert evaluations, focusing on ultrasound features such as composition, echogenicity, shape, margin, and echogenic foci.
Figure 1. Workflow for Thyroid Nodule Ultrasound Feature Analysis Using ChatGPT-4o and Expert Evaluation. Transverse and longitudinal sections of thyroid nodule ultrasound images are cropped and analyzed by ChatGPT-4o. Intra-observer agreement is assessed between two rounds of ChatGPT-4o analyses. Inter-observer agreement is evaluated by comparing ChatGPT-4o’s assessments with expert evaluations, focusing on ultrasound features such as composition, echogenicity, shape, margin, and echogenic foci.
Diagnostics 15 02617 g001
Figure 2. Heatmap of Kappa Values for Intra- and Inter-Observer Agreement in Ultrasound Feature Assessment. The heatmap illustrates the Kappa values for intra-observer and inter-observer agreement across different ultrasound feature categories. Kappa values are color-coded on a gradient from red (indicating very poor agreement) to blue (indicating excellent agreement), with a white transition in between. The gradient from red to white denotes poor agreement, whereas the transition from white to blue reflects improving agreement. Categories include Composition, Echogenicity, Shape, Margin, and Echogenic foci.
Figure 2. Heatmap of Kappa Values for Intra- and Inter-Observer Agreement in Ultrasound Feature Assessment. The heatmap illustrates the Kappa values for intra-observer and inter-observer agreement across different ultrasound feature categories. Kappa values are color-coded on a gradient from red (indicating very poor agreement) to blue (indicating excellent agreement), with a white transition in between. The gradient from red to white denotes poor agreement, whereas the transition from white to blue reflects improving agreement. Categories include Composition, Echogenicity, Shape, Margin, and Echogenic foci.
Diagnostics 15 02617 g002
Figure 3. Concordance Rates between ChatGPT-4o and Expert Evaluations across Ultrasound Features. This bar chart illustrates the concordance rates between ChatGPT-4o and expert evaluations for various ultrasound features of thyroid nodules. The results are presented for two evaluation rounds.
Figure 3. Concordance Rates between ChatGPT-4o and Expert Evaluations across Ultrasound Features. This bar chart illustrates the concordance rates between ChatGPT-4o and expert evaluations for various ultrasound features of thyroid nodules. The results are presented for two evaluation rounds.
Diagnostics 15 02617 g003
Table 1. Baseline characteristics of image dataset.
Table 1. Baseline characteristics of image dataset.
CharacteristicStatistics
Patients98
Sex (Male/Female)19/79
Age (years)54.26 ± 12.19
Nodules (Benign/Malignant)100 (70/30)
Nodule size (cm)2.57 ± 1.23
Notes: Categorical variables are presented as numbers, and continuous variables as mean ± standard deviation.
Table 2. Intra- and inter-observer agreement in ultrasound feature assessment of thyroid nodules by ChatGPT-4o and ultrasound expert.
Table 2. Intra- and inter-observer agreement in ultrasound feature assessment of thyroid nodules by ChatGPT-4o and ultrasound expert.
CategoryChatGPT-4oKappaUltrasound ExpertKappa #Kappa *
1st Round2nd Round
Composition 0.449 0.0920.075
cystic or almost completely cystic23 0
spongiform00 8
mixed cystic and solid1311 37
solid or almost completely solid8586 55
Echogenicity 0.795 −0.006−0.001
anechoic23 0
hyperechoic or isoechoic00 69
hypoechoic9897 30
very hypoechoic00 1
Shape −0.051 0.0260.082
wider-than-tall6268 83
taller-than-wide3832 17
Margin 0.154 0.0960.092
smooth5243 26
ill-defined2322 61
lobulated or irregular2535 11
extra-thyroidal extension00 2
Echogenic foci 0.404 0.1420.238
none 5452 58
large comet-tail artifacts00 0
macrocalcifications10 13
peripheral (rim) calcifications00 1
punctate echogenic foci4548 28
Notes: Kappa denotes intra-observer agreement for ChatGPT-4o. Kappa # and Kappa * indicate inter-observer agreements between the first and second rounds of ChatGPT-4o, respectively, and the ultrasound expert. Bolded terms (Composition, Echogenicity, Shape, Margin, and Echogenic foci) represent the five major ultrasound feature categories according to the ACR TI-RADS classification.
Table 3. Concordance rates between ChatGPT-4o and expert evaluations of thyroid nodule ultrasound features.
Table 3. Concordance rates between ChatGPT-4o and expert evaluations of thyroid nodule ultrasound features.
Category1st Round Concordance Rate2nd Round Concordance Rate
Overall46.6%48.2%
Composition56.0%55.0%
Echogenicity29.0%29.0%
Shape59.0%65.0%
Margin37.0%35.0%
Echogenic foci52.0%57.0%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Chen, Z.; Chambara, N.; Liu, S.Y.W.; Chow, T.C.M.; Lai, C.M.S.; Ying, M.T.C. Intra- and Inter-Observer Reliability of ChatGPT-4o in Thyroid Nodule Ultrasound Feature Analysis Based on ACR TI-RADS: An Image-Based Study. Diagnostics 2025, 15, 2617. https://doi.org/10.3390/diagnostics15202617

AMA Style

Chen Z, Chambara N, Liu SYW, Chow TCM, Lai CMS, Ying MTC. Intra- and Inter-Observer Reliability of ChatGPT-4o in Thyroid Nodule Ultrasound Feature Analysis Based on ACR TI-RADS: An Image-Based Study. Diagnostics. 2025; 15(20):2617. https://doi.org/10.3390/diagnostics15202617

Chicago/Turabian Style

Chen, Ziman, Nonhlanhla Chambara, Shirley Yuk Wah Liu, Tom Chi Man Chow, Carol Man Sze Lai, and Michael Tin Cheung Ying. 2025. "Intra- and Inter-Observer Reliability of ChatGPT-4o in Thyroid Nodule Ultrasound Feature Analysis Based on ACR TI-RADS: An Image-Based Study" Diagnostics 15, no. 20: 2617. https://doi.org/10.3390/diagnostics15202617

APA Style

Chen, Z., Chambara, N., Liu, S. Y. W., Chow, T. C. M., Lai, C. M. S., & Ying, M. T. C. (2025). Intra- and Inter-Observer Reliability of ChatGPT-4o in Thyroid Nodule Ultrasound Feature Analysis Based on ACR TI-RADS: An Image-Based Study. Diagnostics, 15(20), 2617. https://doi.org/10.3390/diagnostics15202617

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop