Next Article in Journal
Tumor-like Lesions in Primary Angiitis of the Central Nervous System: The Role of Magnetic Resonance Imaging in Differential Diagnosis
Next Article in Special Issue
Improved Applicability and Diagnostic Accuracy of the Novel Spleen-Dedicated Transient Elastography Device for High-Risk Esophageal Varices
Previous Article in Journal
Diet and Lifestyle Intervention-Induced Pattern of Weight Loss Related to Reduction in Low-Attenuation Coronary Plaque Burden
Previous Article in Special Issue
Ultrasound-Guided Interventions in the Biliary System
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants

1
Section of Pediatric Radiology, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
2
Department of Radiology, Alta Klinik Bielefeld, 33602 Bielefeld, Germany
3
Radiologie Vechta, Marienstraße 6-8, 49377 Vechta, Germany
4
Department of Visceral Transplantation, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
5
Department of Pediatrics, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
6
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
*
Author to whom correspondence should be addressed.
Diagnostics 2024, 14(6), 617; https://doi.org/10.3390/diagnostics14060617
Submission received: 9 February 2024 / Revised: 9 March 2024 / Accepted: 12 March 2024 / Published: 14 March 2024
(This article belongs to the Special Issue Ultrasound in Liver and Biliary Diseases)

Abstract

(1) Background: Accurate hepatic artery (HA) depiction following pediatric liver transplantation (LT) is essential for graft surveillance but challenging on ultrasound (US). This study assesses if improved HA delineation can be achieved by recording two-dimensional US volumes in Color Doppler (CD) and B-flow technique. (2) Methods: Of 42 consecutive LT, 37 cases were included, and HA delineation was retrospectively rated using a four-point score (0 = HA not detectable, 3 = HA fully detectable, separable from portal vein) within 48 h post-LT (U1) and before discharge (U2). (3) Results: Adding B-flow compared with CD alone showed superior results at neohilar (U1: 2.2 ± 1.0 vs. 1.1 ± 0.8, p < 0.0001; U2: 2.5 ± 0.8 vs. 1.5 ± 0.9, p < 0.0001) and segmental levels (U1: 2.8 ± 0.6 vs. 0.6 ± 0.8, p < 0.0001; U2: 2.8 ± 0.6 vs. 0.7 ± 0.5, p < 0.0001). (4) Conclusions: Standardized US volume recordings combining B-flow and CD can effectively delineate the HA along its vascular course in pediatric LT. The technique should be further evaluated as a standard monitoring instrument to rule out vascular complications after LT.
Keywords: B-flow sonography; Color Doppler sonography; hepatic artery; pediatric liver transplantation; vascular complications B-flow sonography; Color Doppler sonography; hepatic artery; pediatric liver transplantation; vascular complications

Share and Cite

MDPI and ACS Style

Dammann, E.; Steinmeister, L.; Groth, M.; Herden, U.; Fischer, L.; Brinkert, F.; Beime, J.; Tozakidou, M.; Bannas, P.; Herrmann, J. Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants. Diagnostics 2024, 14, 617. https://doi.org/10.3390/diagnostics14060617

AMA Style

Dammann E, Steinmeister L, Groth M, Herden U, Fischer L, Brinkert F, Beime J, Tozakidou M, Bannas P, Herrmann J. Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants. Diagnostics. 2024; 14(6):617. https://doi.org/10.3390/diagnostics14060617

Chicago/Turabian Style

Dammann, Elena, Leonhard Steinmeister, Michael Groth, Uta Herden, Lutz Fischer, Florian Brinkert, Jan Beime, Magdalini Tozakidou, Peter Bannas, and Jochen Herrmann. 2024. "Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants" Diagnostics 14, no. 6: 617. https://doi.org/10.3390/diagnostics14060617

APA Style

Dammann, E., Steinmeister, L., Groth, M., Herden, U., Fischer, L., Brinkert, F., Beime, J., Tozakidou, M., Bannas, P., & Herrmann, J. (2024). Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants. Diagnostics, 14(6), 617. https://doi.org/10.3390/diagnostics14060617

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop