Next Article in Journal
Late Enhancement Computed Tomography for Left Atrial Fibrosis Imaging: A Pilot “Proof-of-Concept” Study
Previous Article in Journal
Optimizing Endoscopic Respiratory Diagnostics with Cytology: An Update on Touch Imprints with a Comparative Literature Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status

1
Department of Cardiology, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands
2
Department of Cardiology, Isala Hospital, 8025 AB Zwolle, The Netherlands
*
Author to whom correspondence should be addressed.
Diagnostics 2024, 14(23), 2752; https://doi.org/10.3390/diagnostics14232752
Submission received: 30 October 2024 / Revised: 25 November 2024 / Accepted: 4 December 2024 / Published: 6 December 2024
(This article belongs to the Section Clinical Diagnosis and Prognosis)

Abstract

Cardiac implantable electronic devices (CIEDs) such as pacemakers and implantable cardioverter-defibrillators (ICDs) are increasingly used in the aging population. Modern CIEDs perform daily measurements, mainly aimed at discovering early signs of battery depletion or electrode dysfunction. Changes in thresholds, intracardiac signals, and pacing impedances can be caused by exacerbation of existing conditions or novel clinical problems. Pacing percentages and heart rate histograms can be used to optimize pacemaker programming, but can also be a measure of altered cardiac health status. Several measurements, such as thoracic impedance and patient activity, have been added to inform practitioners about worsening heart failure. In addition, remote monitoring of daily CIED measurements may accommodate for the prevention of the deterioration of clinical conditions. In this review, we discuss the evidence base of CIED algorithms and suggest how to use standard daily measurements to monitor the cardiac and extracardiac health status of patients with CIEDs.
Keywords: pacemaker; implantable cardioverter-defibrillator; pacing threshold; intracardiac signal; impedance; heart failure pacemaker; implantable cardioverter-defibrillator; pacing threshold; intracardiac signal; impedance; heart failure

Share and Cite

MDPI and ACS Style

Roseboom, E.; Daniëls, F.; Rienstra, M.; Maass, A.H. Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status. Diagnostics 2024, 14, 2752. https://doi.org/10.3390/diagnostics14232752

AMA Style

Roseboom E, Daniëls F, Rienstra M, Maass AH. Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status. Diagnostics. 2024; 14(23):2752. https://doi.org/10.3390/diagnostics14232752

Chicago/Turabian Style

Roseboom, Eva, Fenna Daniëls, Michiel Rienstra, and Alexander H. Maass. 2024. "Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status" Diagnostics 14, no. 23: 2752. https://doi.org/10.3390/diagnostics14232752

APA Style

Roseboom, E., Daniëls, F., Rienstra, M., & Maass, A. H. (2024). Daily Measurements from Cardiac Implantable Electronic Devices to Assess Health Status. Diagnostics, 14(23), 2752. https://doi.org/10.3390/diagnostics14232752

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop