Next Article in Journal
Restricted Mean Survival Time—Can It Be a New Tool in Assessing the Survival of Non-Small Cell Lung Cancer Patients Treated with Immune Checkpoint Inhibitors?
Previous Article in Journal
QuPath Algorithm Accurately Identifies MLH1-Deficient Inflammatory Bowel Disease-Associated Colorectal Cancers in a Tissue Microarray
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Assessment of the Graft Quality and Patency during and after Coronary Artery Bypass Grafting

1
Department of Cardiovascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
2
Department of Cardiothoracic and Vascular Surgery, Amiri Medical Complex, Qargha Rd., Kabul 1010, Afghanistan
3
Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
*
Author to whom correspondence should be addressed.
Diagnostics 2023, 13(11), 1891; https://doi.org/10.3390/diagnostics13111891
Submission received: 27 March 2023 / Revised: 3 May 2023 / Accepted: 23 May 2023 / Published: 29 May 2023
(This article belongs to the Topic Cardiac Imaging: State of the Art)

Abstract

Coronary artery bypass grafting (CABG) is the gold standard procedure for multi vessels and left main coronary artery disease. The prognosis and survival outcomes of CABG surgery are highly dependent on the patency of the bypass graft. Early graft failure which can occur during or soon after CABG remains a significant issue, with reported incidences of 3–10%. Graft failure can lead to refractory angina, myocardial ischemia, arrhythmias, low cardiac output, and fatal cardiac failure, emphasizing the importance of ensuring graft patency during and after surgery to prevent such complications. Technical errors during anastomosis are among the leading causes of early graft failure. To address this issue, various modalities and techniques have been developed to evaluate graft patency during and after CABG surgery. These modalities aim to assess the quality and integrity of the graft, thus enabling surgeons to identify and address any issues before they lead to significant complications. In this review article, we aim to discuss the strengths and limitations of all available techniques and modalities, with the goal to identify the best modality for evaluating graft patency during and after CABG surgery.
Keywords: coronary artery bypass surgery; revascularization; graft quality assessment; angiography; CTA coronary artery bypass surgery; revascularization; graft quality assessment; angiography; CTA

Share and Cite

MDPI and ACS Style

Masroor, M.; Ahmad, A.; Wang, Y.; Dong, N. Assessment of the Graft Quality and Patency during and after Coronary Artery Bypass Grafting. Diagnostics 2023, 13, 1891. https://doi.org/10.3390/diagnostics13111891

AMA Style

Masroor M, Ahmad A, Wang Y, Dong N. Assessment of the Graft Quality and Patency during and after Coronary Artery Bypass Grafting. Diagnostics. 2023; 13(11):1891. https://doi.org/10.3390/diagnostics13111891

Chicago/Turabian Style

Masroor, Matiullah, Ashfaq Ahmad, Yixuan Wang, and Nianguo Dong. 2023. "Assessment of the Graft Quality and Patency during and after Coronary Artery Bypass Grafting" Diagnostics 13, no. 11: 1891. https://doi.org/10.3390/diagnostics13111891

APA Style

Masroor, M., Ahmad, A., Wang, Y., & Dong, N. (2023). Assessment of the Graft Quality and Patency during and after Coronary Artery Bypass Grafting. Diagnostics, 13(11), 1891. https://doi.org/10.3390/diagnostics13111891

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop