Next Article in Journal
Influence of Visual Information and Sex on Postural Control in Children Aged 6–12 Years Assessed with Accelerometric Technology
Next Article in Special Issue
Assessment of 3D Lumbosacral Vascular Anatomy for OLIF51 by Non-Enhanced MRI and CT Medical Image Fusion Technique
Previous Article in Journal
The Role of Speckle Tracking Echocardiography in the Evaluation of Common Inherited Cardiomyopathies in Children and Adolescents: A Systematic Review
Previous Article in Special Issue
Changes of Fixed Anatomical Spinopelvic Parameter in Patients with Lumbosacral Transitional Vertebrae: A Matched Pair Analysis
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Technical Note

Percutaneous C-Arm Free O-Arm Navigated Biopsy for Spinal Pathologies: A Technical Note

1
Department of Orthopaedic Surgery, Okayama Rosai Hospital, 1-10-25 Chikkomidorimachi, Minami Ward Okayama 702-8055, Okayama, Japan
2
Department of Orthopaedic Surgery, Shikoku Cancer Center, 160 Ko Minamiumemotomachi, Matsuyama 791-0280, Ehime, Japan
*
Author to whom correspondence should be addressed.
Diagnostics 2021, 11(4), 636; https://doi.org/10.3390/diagnostics11040636
Submission received: 3 March 2021 / Revised: 31 March 2021 / Accepted: 31 March 2021 / Published: 1 April 2021
(This article belongs to the Special Issue Spine Surgery: State of the Art Diagnostics)

Abstract

:
Background: Percutaneous biopsy under computed tomography (CT) guidance is a standard technique to obtain a definitive diagnosis when spinal tumors, metastases or infections are suspected. However, specimens obtained using a needle are sometimes inadequate for correct diagnosis. This report describes a unique biopsy technique which is C-arm free O-arm navigated using microforceps. This has not been previously described as a biopsy procedure. Case description: A 74-year-old man with T1 vertebra pathology was referred to our hospital with muscle weakness of the right hand, clumsiness and cervicothoracic pain. CT-guided biopsy was performed, but histopathological diagnosis could not be obtained due to insufficient tissue. The patient then underwent biopsy under O-arm navigation, so we could obtain sufficient tissue and small cell carcinoma was diagnosed on histopathological examination. A patient later received chemotherapy and radiation. Conclusions: C-arm free O-arm navigated biopsy is an effective technique for obtaining sufficient material from spine pathologies. Tissue from an exact pathological site can be obtained with 3-D images. This new O-arm navigation biopsy may provide an alternative to repeat CT-guided or open biopsy.

Graphical Abstract

1. Introduction

The incidence of skeletal metastasis is approximately 20%, with the spinal column as the most common location [1]. More than 10% of cancer patients develop symptomatic spinal metastasis, particularly involving the thoracic spine [2,3]. The most frequent metastasis to the spine is from lung cancer, followed by breast and prostate cancer [4]. If the primary site of cancer is known, the biopsy of metastatic spinal tumors is unnecessary [5]. However, biopsy is needed for accurate diagnosis when the primary site is unknown [6]. The proper treatment of spinal lesions depends on precise histological diagnosis.
The core needle biopsy (CNB) of spinal lesions under computed tomography (CT) guidance is a valuable and effective diagnostic tool to plan correct therapeutic strategy [7]. However, multiple CT scans may be required for this procedure for the confirmation of needle placement. Still sufficient material cannot be obtained sometimes as the bore of the needle is small, therefore, the diagnostic accuracy of this procedure remains around 80% [8]. Open biopsy may be needed in such situations which requires a relatively large skin incision and intraoperative confirmation of the biopsy site can be difficult if the target is very small. The difficulty of open biopsy further increase if the lesion is close to important organs such as the spinal cord, vital organs and great vessels. To perform spinal biopsy safely and precisely, we herein introduced a novel technique of C-arm free percutaneous spinal biopsy with an O-arm navigation.

2. Methods

Patient history. A 74-year-old man with a pathology of the T1 vertebra was referred to our hospital. The patient reported two months’ history of muscle weakness of the right hand and cervicothoracic pain.
Physical examination. On examination, the patient described pain, numbness and clumsiness of the right hand. He could walk without support and showed no spasticity of the legs. He reported cervicothoracic pain on movement and manual muscle test (MMT) scores were 3–4 for right hands.
Preoperative imaging. Radiographs did not show a clear pedicle winking owl sign at the T1 vertebra (Figure 1). CT indicated an osteolytic lesion in the right T1 pedicle and T1 vertebral collapse. The reconstruction three-dimensional (3D) CT showed a collapse of the right side of the vertebral body and lateral mass in T1 vertebra (Figure 2). Magnetic resonance imaging (MRI) indicated spinal cord compression by an epidural mass at the T1 level (Figure 3).
Navigated biopsy procedures. The patient is placed in a prone position under general anesthesia on a Jackson frame to perform the O-arm scan. A reference frame (RF) is attached to the spinous process near the targeted area. For the upper cervical spine and cervicothoracic junction, the C2 and C7/T1 spinous processes are the best RF sites, respectively, because these are prominent and allow the easy attachment of the RF. For the thoracolumbar junction and lumbar spine, the T12/L1 spinous processes and sacroiliac joint are good options for RF placement (Figure 4).
The O-arm is then positioned and the reconstructed 3D images are obtained and transmitted to the Stealth Station navigation system Spine 7® (Medtronic, Medtronic Sofamor Danek, Minneapolis, MN, USA). After every navigated spinal instrument is verified, the best entry point for the biopsy is marked by the navigated pointer (Figure 5A,B). A 5 mm skin incision is then made and the cortex of the targeted pedicle is penetrated by the navigated high-speed burr or navigated awl. A navigated pedicle probe is used to make a hole and reach the lesion (pedicle or vertebra) (Figure 5C,D). A small tube with a diameter of 5 mm and navigated tip is inserted (Figure 6A,B) and tumor tissue is obtained using micropituitary forceps (Figure 6C,D). In this procedure, the special non-navigated forceps is used whose tip passes only 8 mm beyond the tube. Thus, this maintains safety.

3. Results

CT-guided biopsy was performed for this patient, but diagnosis could not be obtained due to insufficient material. The patient then underwent C-arm-free O-arm navigated percutaneous spinal biopsy. After the O-arm navigated biopsy, small cell carcinoma was diagnosed. The patient was treated with chemotherapy and radiation without spinal decompression and fixation.

Indications for Navigated Biopsy

The indications for this technique are spinal pathologies that include all the following conditions: lesion in the vertebra without known primary; failure of spinal CNB; and no other suitable biopsy site than the spine (Table 1).

4. Discussion

With the advent of MRI, more spinal pathologies can be diagnosed nowadays [9]. For the proper diagnosis of these pathologies, biopsy is needed. Various options available for biopsy are C-arm-guided, CT-guided and open biopsy. C-arm-guided biopsy is a good option but the diagnostic yield is around 56% for tumorous lesions [10]. Another problem with C-arm is that visibility in the high thoracic lesion is poor due to shoulder, scapula and lung shadows. In osteoporotic and obese patients, the C-arm image is poor and it is difficult to delineate bone shadows. Percutaneous CT-guided CNB is a modern method to obtain tissue from spinal pathologies. CNB under CT guidance is a fast, relatively simple, minimally invasive, and low-cost method for spinal lesions. However, CT-guided biopsy has disadvantages like a need for multiple scans for the proper placement of the needle, since there is no real-time image and it is not done in the sterile environment of operation room. The literature suggests that there is a risk of complications like neurological and vital organ injury in up to 26% cases in CT-guided biopsy [11,12,13]. The accuracy of this procedure has been reported as up to 80% [14,15]. If CT-guided CNB fails, another CT biopsy or open biopsy may be performed to obtain a sufficient amount of pathological material. It has been reported that the diagnosis was obtained in only 14% to 38% cases after repeat CNB for an initially nondiagnostic result [16,17]. The open biopsies of spinal tumors carry a potential risk of complications, such as massive bleeding, infection, damage to surrounding structures and a spread of pathology [18,19].
With our new technique, biopsy is performed by micro-forceps under local or general anesthesia and O-arm navigation guidance. A sufficient amount of material can thus be obtained. The risk of neural complications and organ injury can be reduced, because of the navigation. Performing this procedure does not require multiple CT scans. Thus, radiation exposure to the patient is reduced. We usually use a small field of view, low-dose mode for the O-arm 3D scan to reduce radiation to the patient. With this technique, we can reduce radiation exposure to operating room staff too [20].
This technique has some disadvantages. General anesthesia is preferable for this technique. Another disadvantage is that one more incision is needed for reference frame placement. If the reference frame is moved, the risk of navigation error is high [20]. Surgeons should therefore check the navigational accuracy; if there is any doubt regarding navigational accuracy, another O-arm scan should be taken.

5. Conclusions

O-arm navigation-guided biopsy provides sufficient tissue from an exact location for the accurate diagnosis of spinal pathologies. This procedure for spine biopsy reduces the risk of adverse events of intraoperative radiation to operation staff and patients. This new O-arm navigation biopsy may provide an alternative to repeat CT-guided or open biopsy.

Author Contributions

M.T.: conceptualization, methodology, supervision. S.S. (Sumeet Sonawane): writing—review and editing. K.U.: writing—original draft preparation. Y.F.: writing—original draft preparation. K.S.: investigation. T.Y.: writing—original draft preparation. S.S. (Shinsuke Sugihara): writing—review and editing. All authors have read and agreed to the published version of the manuscript.

Funding

No funding was received for this research.

Institutional Review Board Statement

This study was approved by our institutional review board of Okayama Rosai Hospital, Okayama, Japan. Approval number is 273 and the date of approval is 12 January 2021. The study was conducted according to the guidelines of the Declaration of Helsinki.

Informed Consent Statement

Informed consent was obtained from all subjects involved in this study.

Data Availability Statement

No new data were created or analyzed in this study. Data sharing is not applicable to this article.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Hosono, N.; Yonenobu, K.; Fuji, T.; Ebara, S.; Yamashita, K.; Ono, K. Orthopaedic management of spinal metastases. Clin. Orthop. Relat. Res. 1995, 312, 148–159. [Google Scholar]
  2. Harrington, K.D. Orthopedic surgical management of skeletal complications of malignancy. Cancer 1997, 80 (Suppl. S8), S1614–S1627. [Google Scholar] [CrossRef]
  3. Gokaslan, Z.L.; York, J.E.; Walsh, G.L.; McCutcheon, I.E.; Lang, F.F.; Putnam, J.B., Jr.; Sawaya, R. Transthoracic vertebrectomy for metastatic spinal tumors. J. Neurosurg. 1998, 89, 599–609. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Findlay, J.M.; Bernstein, M.; Vanderlinden, R.G.; Resch, L. Microsurgical resection of solitary intramedullary spinal cord metastases. Neurosurgery 1987, 21, 911–915. [Google Scholar] [CrossRef] [PubMed]
  5. Buyukbebeci, O.; Karakurum, G.; Tutar, E.; Gulec, A.; Arpacioglu, O. Biopsy of vertebral tumour metastasis for diagnosing unknown primaries. J. Orthop. Surg. 2010, 18, 361–363. [Google Scholar] [CrossRef]
  6. Destombe, C.; Botton, E.; Le Gal, G.; Roudaut, A.; Jousse-Joulin, S.; Devauchelle-Pensec, V.; Saraux, A. Investigations for bone metastasis from an unknown primary. Jt. Bone Spine 2007, 74, 85–89. [Google Scholar] [CrossRef] [PubMed]
  7. Dupuy, D.E.; Rosenberg, A.E.; Punyaratabandhu, T.; Tan, M.H.; Mankin, H.J. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am. J. Roentgenol. 1998, 171, 759–762. [Google Scholar] [CrossRef] [PubMed]
  8. Schweitzer, M.E.; Gannon, F.H.; Deely, D.M.; O’Hara, B.J.; Juneja, V. Percutaneous skeletal aspiration and core biopsy: Complementary techniques. AJR Am. J. Roentgenol. 1996, 166, 415–418. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  9. Schepper, E.; Koes, B.; Veldhuizen, E.; Oei, E.; Bierma-Zeinstra, S.; Luijsterburg, P. Prevalence of spinal pathology in patients presenting for lumbar MRI as referred from general practice. Fam. Pract. 2016, 33, 51–56. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  10. Cortet, B.; Coquerelle, P.; Cotton, A.; Delambre, C. Diagnostic value of spinal puncture biopsy in non infectious spinal disease. Rev. Rhum. 1994, 61, 505–511. [Google Scholar]
  11. Mankin, H.J.; Lange, T.A.; Spanier, S.S. The hazards of biopsy in patients with malignant primary bone and soft-tissue tumors. J. Bone Jt. Surg. Am. 1982, 64, 1121–1127. [Google Scholar] [CrossRef]
  12. Laredo, J.D.; Bard, M. Thoracic spine: Percutaneous trephine biopsy. Radiology 1986, 160, 485–489. [Google Scholar] [CrossRef] [PubMed]
  13. Olscamp, A.; Rollins, J.; Tao, S.S.; Ebraheim, N.A. Complications of CT-guided biopsy of the spine and sacrum. Orthopedics 1997, 20, 1149–1152. [Google Scholar] [PubMed]
  14. Kaltsikis, I.; Chourmouzi, D.; Drevelegas, K.; Potsi, S.; Moumtzouoglou, A.; Drevelegas, A. Core needle biopsy of spinal lesions under CT guidance: Review of 79 cases. J. Neurol. Surg. A Cent. Eur. Neurosurg. 2012, 73, 199–203. [Google Scholar] [CrossRef] [PubMed]
  15. Kornblum, M.B.; Wesolowski, D.P.; Fischgrund, J.S.; Herkowitz, H.N. Computed tomography-guided biopsy of the spine. A review of 103 patients. Spine 1998, 23, 81–85. [Google Scholar] [CrossRef] [PubMed]
  16. Czuczman, G.J.; Marrero, D.E.; Huang, A.J.; Mandell, J.C.; Ghazikhanian, V.; Simeone, F.J. Diagnostic yield of repeat CT-guided biopsy for suspected infectious spondylodiscitis. Skelet. Radiol. 2018, 47, 1403–1410. [Google Scholar] [CrossRef] [PubMed]
  17. Wu, J.S.; McMahon, C.J.; Lozano-Calderon, S.; Kung, J.W. Utility of repeat core needle biopsy of musculoskeletal lesions with initially nondiagnostic findings. AJR Am. J. Roentgenol. 2017, 208, 609–616. [Google Scholar] [CrossRef] [PubMed]
  18. Fyfe, I.S.; Henry, A.P.; Mulholland, R.C. Closed vertebral biopsy. J. Bone Jt. Surg. Br. 1983, 65, 140–143. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  19. Nam, K.H.; Song, G.S.; Han, I.H.; Choi, B.K.; Cha, S.H. Diagnostic Value of Biopsy Techniques in Lumbar Spondylodiscitis: Percutaneous Needle Biopsy and Open Biopsy. Korean J. Spine 2011, 8, 267–271. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  20. Tanaka, M.; Fujiwara, Y.; Uotani, K.; Maste, P.; Yamauchi, T. C-Arm-Free Circumferential Minimally Invasive Surgery for Adult Spinal Deformity: Technical Note. World Neurosurg. 2020, 143, 235–246. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Radiograms of the patient show no pedicle winking owl sign at the right T1 vertebra: (A) cervical anteroposterior view; (B) cervical lateral view; (C) thoracic anteroposterior view; and (D) thoracic lateral view. White arrows indicate tumor location.
Figure 1. Radiograms of the patient show no pedicle winking owl sign at the right T1 vertebra: (A) cervical anteroposterior view; (B) cervical lateral view; (C) thoracic anteroposterior view; and (D) thoracic lateral view. White arrows indicate tumor location.
Diagnostics 11 00636 g001
Figure 2. Computed tomography (CT) (A) Axial view—an osteolytic lesion was identified in the right T1 pedicle; (B) sagittal reconstruction view—the T1 vertebra collapsed; (C) anterior 3D—the right side of the T1 vertebra collapsed; and (D) lateral 3D. White arrows indicate tumor location.
Figure 2. Computed tomography (CT) (A) Axial view—an osteolytic lesion was identified in the right T1 pedicle; (B) sagittal reconstruction view—the T1 vertebra collapsed; (C) anterior 3D—the right side of the T1 vertebra collapsed; and (D) lateral 3D. White arrows indicate tumor location.
Diagnostics 11 00636 g002
Figure 3. Magnetic resonance imaging (MRI) shows spinal cord compression by an epidural mass at the T1 level: (A) T1-weighted midsagittal image; (B) T2-weighted midsagittal image; and (C) T2-weighted axial image at the T1 vertebral level.
Figure 3. Magnetic resonance imaging (MRI) shows spinal cord compression by an epidural mass at the T1 level: (A) T1-weighted midsagittal image; (B) T2-weighted midsagittal image; and (C) T2-weighted axial image at the T1 vertebral level.
Diagnostics 11 00636 g003
Figure 4. Position of the reference frame.
Figure 4. Position of the reference frame.
Diagnostics 11 00636 g004
Figure 5. Skin incision and pedicle perforation under navigation: (A) the navigated pointer; (B) intraoperative navigation monitor; (C) the navigated pedicle probe; and (D) the intraoperative navigation monitor.
Figure 5. Skin incision and pedicle perforation under navigation: (A) the navigated pointer; (B) intraoperative navigation monitor; (C) the navigated pedicle probe; and (D) the intraoperative navigation monitor.
Diagnostics 11 00636 g005
Figure 6. C-arm free O-arm navigated biopsy: (A) the tube insertion under navigation; (B) the small tube with a navigated probe; (C) intraoperative navigation monitor; and (D) the material from the biopsy.
Figure 6. C-arm free O-arm navigated biopsy: (A) the tube insertion under navigation; (B) the small tube with a navigated probe; (C) intraoperative navigation monitor; and (D) the material from the biopsy.
Diagnostics 11 00636 g006
Table 1. Indications for navigated biopsy.
Table 1. Indications for navigated biopsy.
Category
Primary lesionUnknown
Tumor locationLamina, pedicle, vertebral body,
paravertebral mass
Core needle biopsyFailure or impossible
Extra-spinal lesionNone or no suitable lesion for biopsy
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Tanaka, M.; Sonawane, S.; Uotani, K.; Fujiwara, Y.; Sessumpun, K.; Yamauchi, T.; Sugihara, S. Percutaneous C-Arm Free O-Arm Navigated Biopsy for Spinal Pathologies: A Technical Note. Diagnostics 2021, 11, 636. https://doi.org/10.3390/diagnostics11040636

AMA Style

Tanaka M, Sonawane S, Uotani K, Fujiwara Y, Sessumpun K, Yamauchi T, Sugihara S. Percutaneous C-Arm Free O-Arm Navigated Biopsy for Spinal Pathologies: A Technical Note. Diagnostics. 2021; 11(4):636. https://doi.org/10.3390/diagnostics11040636

Chicago/Turabian Style

Tanaka, Masato, Sumeet Sonawane, Koji Uotani, Yoshihiro Fujiwara, Kittipong Sessumpun, Taro Yamauchi, and Shinsuke Sugihara. 2021. "Percutaneous C-Arm Free O-Arm Navigated Biopsy for Spinal Pathologies: A Technical Note" Diagnostics 11, no. 4: 636. https://doi.org/10.3390/diagnostics11040636

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop