Next Article in Journal
Telecoupled Groundwaters: New Ways to Investigate Increasingly De-Localized Resources
Previous Article in Journal
Development and Evaluation of a Chinook Salmon Smolt Swimming Behavior Model
Article

Study of Long-Term Effectiveness of Water Safety Plan Applied to Microfiltered Water Dispensers to Improve Water Quality

Department of Biological, Geological, and Environmental Sciences, University of Bologna, via San Giacomo 12, 40126 Bologna, Italy
*
Author to whom correspondence should be addressed.
Academic Editors: Layla Ben Ayed, Eleni Golomazou, Panagiotis Karanis, Patrick Scheid, Ourania Tzoraki, Anna Lass and Muhammad Shahid Iqbal
Water 2021, 13(20), 2905; https://doi.org/10.3390/w13202905
Received: 30 September 2021 / Revised: 13 October 2021 / Accepted: 14 October 2021 / Published: 16 October 2021
(This article belongs to the Topic Emerging Solutions for Water, Sanitation and Hygiene)
The use of Microfiltered Water Dispensers (MWDs) is increasing in offices, companies, or commercial facilities, as a response to plastic pollution. Despite their widespread use, poor data are available about the water quality and pathogens developed. Starting from a high contamination found in MWDs, a Water Safety Plan (WSP) was implemented on 57 MWDs to improve the water quality. To assess the effectiveness of WSP during the period 2017–2021, the environmental monitoring of heterotrophic plate counts (HPCs) at 36 °C and 22 °C, Enterococcus spp., Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus, and Clostridium perfringens, as prescribed by Italian regulation for drinking water, was conducted. A high level of HPCs at both temperatures was observed, over the regulation limit; contrarily, the pathogenic bacteria were absent. The contamination found was studied with respect to the temperature threshold of 25 °C, suggested by directives. No significant differences were found between samples above and below the threshold, while a significant decrease over the years was observed for HPCs at 36 °C (p = 0.0000000001) and 22 °C (p = 0.000006). The WSP implementation resulted in a 43.09% decrease for HPCs at 36 °C and a 24.26% decrease for HPCs at 22 °C. Moreover, during the SARS-CoV-2 pandemic, the WSP contributed to limit the microbial contamination, preserving the MWDs’ functionality and hygienic conditions and the drinking water quality. View Full-Text
Keywords: Water Safety Plan; Microfiltered Water Dispensers; heterotrophic plate counts’ contamination; maintenance and sanitation procedures; drinking water quality; water temperature Water Safety Plan; Microfiltered Water Dispensers; heterotrophic plate counts’ contamination; maintenance and sanitation procedures; drinking water quality; water temperature
Show Figures

Figure 1

MDPI and ACS Style

Mazzotta, M.; Salaris, S.; Pascale, M.R.; Girolamini, L.; Ciani, G.; Cristino, S. Study of Long-Term Effectiveness of Water Safety Plan Applied to Microfiltered Water Dispensers to Improve Water Quality. Water 2021, 13, 2905. https://doi.org/10.3390/w13202905

AMA Style

Mazzotta M, Salaris S, Pascale MR, Girolamini L, Ciani G, Cristino S. Study of Long-Term Effectiveness of Water Safety Plan Applied to Microfiltered Water Dispensers to Improve Water Quality. Water. 2021; 13(20):2905. https://doi.org/10.3390/w13202905

Chicago/Turabian Style

Mazzotta, Marta, Silvano Salaris, Maria R. Pascale, Luna Girolamini, Graziella Ciani, and Sandra Cristino. 2021. "Study of Long-Term Effectiveness of Water Safety Plan Applied to Microfiltered Water Dispensers to Improve Water Quality" Water 13, no. 20: 2905. https://doi.org/10.3390/w13202905

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1