Next Article in Journal
Co-Ni Cyanide Bi-Metal Catalysts: Copolymerization of Carbon Dioxide with Propylene Oxide and Chain Transfer Agents
Previous Article in Journal
Catalysis inside Supramolecular Capsules: Recent Developments
Open AccessArticle

Enhanced Electrocatalytic Behaviour of Poy(aniline-co-2-hydroxyaniline) Coated Electrodes for Hydrogen Peroxide Electrooxidation

1
Institute of Chemical Sciences, University of Peshawar, Peshawar 25120, Pakistan
2
National Centre of Excellence in Physical Chemistry, University of Peshawar, Peshawar 25120, Pakistan
3
TU Braunschweig Institute of Energy and Process Systems Engineering, Franz-Liszt-Straße 35, 38106 Braunschweig, Germany
*
Author to whom correspondence should be addressed.
Catalysts 2019, 9(8), 631; https://doi.org/10.3390/catal9080631
Received: 25 June 2019 / Revised: 12 July 2019 / Accepted: 20 July 2019 / Published: 24 July 2019
(This article belongs to the Special Issue Women in Catalysis)
Polymer-coated electrodes are widely used for the detection and oxidation of hydrogen peroxide (H2O2). Conducting polyaniline (PANI), poly (2-hydroxyanilne) (PHA), and their copolymer poly(aniline-co-2-hydroxyaniline) (PACHA) were electrochemically synthesized on a gold substrate for H2O2 detection and analysis. Cyclic voltammetry (CV), square wave voltammetry (SWV), and differential pulse voltammetry (DPV) techniques were used for electroanalysis. Both PACHA and PANI greatly reduced the gold overpotential for H2O2 oxidation with enhanced current densities. The PACHA- and PANI-coated electrodes showed oxidative peaks at 0.30 and 0.50 V, respectively, in the presence of 1.4 × 10−6 M H2O2, while PHA-coated electrodes exhibited no response. The fabricated electrodes displayed a linear response towards H2O2 in range of 2 × 10−7 to 1.4 × 10−6 M, with very low detection limits (LODs) of 1 × 10−7 M (for PACHA) and 1.15 × 10−7 M (for PANI) evaluated from CV data. In case of SWV and DPV, the LODs were found to be 1.78 × 10−7 M (for PACHA) and 1 × 10−7 M (for PANI), respectively. The materials exhibit high sensitivity of 650 A/Mcm2 and show good stability. The PACHA-coated electrode shows better capacitance (1.84 × 10−3 F) than PHA- (2.52 × 10−4 F) and PANI-coated (1.17 × 10−3 F) electrodes. View Full-Text
Keywords: electrode fabrication; poly(aniline-co-2-hydroxyaniline); hydrogen peroxide; electroanalysis electrode fabrication; poly(aniline-co-2-hydroxyaniline); hydrogen peroxide; electroanalysis
Show Figures

Figure 1

MDPI and ACS Style

Shah, A.H.A.; Inayat, A.; Bilal, S. Enhanced Electrocatalytic Behaviour of Poy(aniline-co-2-hydroxyaniline) Coated Electrodes for Hydrogen Peroxide Electrooxidation. Catalysts 2019, 9, 631.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop