Next Article in Journal
Implementation of a Wideband Microwave Filter Design with Dual Electromagnetic Interference (EMI) Mitigation for Modern Wireless Communication Systems with Low Insertion Loss and High Selectivity
Next Article in Special Issue
Editorial for the Special Issue on Magnetic and Spin Devices, Volume II
Previous Article in Journal
Tackling Multi-Physics Nano-Scale Phenomena in Capillary Force Lithography with Small Data by Hybrid Intelligence
Previous Article in Special Issue
A Comprehensive Study of Temperature and Its Effects in SOT-MRAM Devices
 
 
Article
Peer-Review Record

In Situ Study of the Magnetic Field Gradient Produced by a Miniature Bi-Planar Coil for Chip-Scale Atomic Devices

Micromachines 2023, 14(11), 1985; https://doi.org/10.3390/mi14111985
by Yao Chen 1,2, Jiyang Wang 1, Ning Zhang 3,*, Jing Wang 4, Yintao Ma 1, Mingzhi Yu 1, Yanbin Wang 1, Libo Zhao 1 and Zhuangde Jiang 1
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Micromachines 2023, 14(11), 1985; https://doi.org/10.3390/mi14111985
Submission received: 2 September 2023 / Revised: 20 October 2023 / Accepted: 24 October 2023 / Published: 26 October 2023
(This article belongs to the Special Issue Magnetic and Spin Devices, 3rd Edition)

Round 1

Reviewer 1 Report

The manuscript should be reduced because there are many repetitions in it.

1.     Figs. 1 and 2 are represented at Fig. 4 in a more informative form.

2.     The parameters of the vapor сell and some other elements of the experimental setup are repeated many times: on pages 3, 5, 6, 7

3.     Eq. (6) contains undefined symbols.

4.     Definition of the error in Eq. (2) is incorrect because it defines a deviation.

5.     Figures 6 – 8 contain very little information and can be replaced by the presentation of the results in the text.

6.     There are many typos.

 

The authors claim on page 12 that the coils only create gradients ∂Bx/∂x, ∂By/∂y and ∂Bz/∂z, but from the Maxwell equations we have divB=∂Bx/∂x + ∂By/∂y + ∂Bz/∂z =0. Unfortunately, the authors don’t mansion about it. In this case, the definition of these derivatives as magnetic field gradients is incorrect. This fact should be taken into account when discussing the relaxation on page 13.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Please address next comments:

- Include a 3D or 2D image of the coils design. Figures 1 and 2 claims to show the design but it is not totally clear how the design is done. Fig 1 and 2 seems more a simulation than a design, which are the current tracks line, what lines are conductive and what are insulating? Provide a more clear description of the part to be machined.  Where does the current get into the coil and where does it exit. Which are those connections points.

- Could you provide mor information about the calculations on the magnetic field shown in fig 12 and 13? It is purely analyticial, FEM?  Could you add the coils design it self? provide cross sections 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 3 Report

The manuscript describes an approach to measure the magnetic field gradient of a bi-planar miniature coil. Results obtained in the paper may be used in designing various atomic devices, including magnetic resonance imaging systems. The manuscript makes positive impression, it is well written and readable. Authors provide analytical calculations, finite element simulation and experimental results on the magnetic field of the coil, which support the conclusions. The paper is interesting for large area of science, including biology and medicine. In my opinion, it can be published in Micromachines after minor corrections:

1. In the introduction, I recommend highlighting the scientific novelty a bit stronger. Is the proposed method for masuring the magnetic field gradient novel? If not, what new ideas do the authors propose?

2. In page 6, the authors say “make it more conducive to miniaturization”. I recommend saying “make it more suitable for miniaturization”.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

The authors tok into account allmy wishes and answered the  comments in a reasoned manner. The article can be accepted for publication.