Next Article in Journal
Prediction of Forest Structural Parameters Using Airborne Full-Waveform LiDAR and Hyperspectral Data in Subtropical Forests
Next Article in Special Issue
CubeSats Enable High Spatiotemporal Retrievals of Crop-Water Use for Precision Agriculture
Previous Article in Journal
Semi-Automated Classification of Lake Ice Cover Using Dual Polarization RADARSAT-2 Imagery
Previous Article in Special Issue
Towards Estimating Land Evaporation at Field Scales Using GLEAM
Open AccessArticle

Estimating Evapotranspiration in a Post-Fire Environment Using Remote Sensing and Machine Learning

Civil, Construction and Environmental Engineering, San Diego State University, San Diego, CA 92182, USA
*
Author to whom correspondence should be addressed.
Remote Sens. 2018, 10(11), 1728; https://doi.org/10.3390/rs10111728
Received: 10 September 2018 / Revised: 20 October 2018 / Accepted: 30 October 2018 / Published: 2 November 2018
(This article belongs to the Special Issue Advances in the Remote Sensing of Terrestrial Evaporation)
In the hydrological cycle, evapotranspiration (ET) transfers moisture from the land surface to the atmosphere and is sensitive to disturbances such as wildfires. Ground-based pre- and post-fire measurements of ET are often unavailable, limiting the potential to understand the extent of wildfire impacts on the hydrological cycle. This research estimated both pre- and post-fire ET using remotely sensed variables and support vector machine (SVM) methods. Input variables (land surface temperature, modified soil-adjusted vegetation index, normalized difference moisture index, normalized burn ratio, precipitation, potential evapotranspiration, albedo and vegetation types) were used to train and develop 56 combinations that yielded 33 unique SVM models to predict actual ET. The models were trained to predict a spatial ET, the Operational Simplified Surface Energy Balance (SSEBop), for the 2003 Coyote Fire in San Diego, California (USA). The optimal SVM model, SVM-ET6, required six input variables and predicted ET for fifteen years with a root-mean-square error (RMSE) of 8.43 mm/month and a R2 of 0.89. The developed model was transferred and applied to the 2003 Old Fire in San Bernardino, California (USA), where a watershed balance approach was used to validate SVM-ET6 predictions. The annual water balance for ten out of fifteen years was within ±20% of the predicted values. This work demonstrated machine learning as a viable method to create a remotely-sensed estimate with wide applicability for regions with sparse data observations and information. This innovative work demonstrated the potential benefit for land and forest managers to understand and analyze the hydrological cycle of watersheds that experience acute disturbances based on this developed predictive ET model. View Full-Text
Keywords: evapotranspiration (ET); remote sensing; support vector machine (SVM); disturbance hydrology evapotranspiration (ET); remote sensing; support vector machine (SVM); disturbance hydrology
Show Figures

Graphical abstract

MDPI and ACS Style

Poon, P.K.; Kinoshita, A.M. Estimating Evapotranspiration in a Post-Fire Environment Using Remote Sensing and Machine Learning. Remote Sens. 2018, 10, 1728.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop