Next Article in Journal
Laser-Assisted Synthesis of Composite Nanoparticles of Perovskite BaTiO3 in Aqueous Solutions and Their Optical Properties
Previous Article in Journal
Experimental Study on the Skidding Damage of a Cylindrical Roller Bearing
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study

1
Department of Biomaterials Science, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
2
Department of Orthodontics and Dentofacial Orthopedics, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
3
Division of Applied Chemistry, Osaka University Graduate School of Engineering, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan
*
Author to whom correspondence should be addressed.
Materials 2020, 13(18), 4085; https://doi.org/10.3390/ma13184085
Submission received: 4 August 2020 / Revised: 11 September 2020 / Accepted: 11 September 2020 / Published: 14 September 2020
(This article belongs to the Section Biomaterials)

Abstract

The aim of this study was to investigate the orthodontic force exerted by thermoplastic orthodontic appliances incorporating Eucommiaulmoides in terms of usefulness as the aligner-type orthodontic device. Erkodur, Essix C+®, Eucommia elastomer, and edgewise brackets were used (n = 3, each; thickness = 1.0 mm, each). The orthodontic force on the upper right incisor was measured every 24 h for two weeks using a custom-made measuring device. The force of the Eucommia elastomer (4.25 ± 0.274 N) and multi bracket system (5.32 ± 0.338 N) did not change from the beginning to the end (p > 0.01). The orthodontic force exerted by the Eucommia elastomer was lower than that of the multi-bracket orthodontic appliance from the beginning to the end. The force of Erkodur significantly decreased from the beginning to 24 h (6.47 ± 1.40 N) and 48 h (3.30 ± 0.536 N) (p < 0.01). The force of Essix C+® significantly decreased from the beginning (13.2 ± 0.845 N) to 24 h (8.77 ± 0.231 N) (p < 0.01). The thermoplastic orthodontic appliance made of Eucommia elastomer continuously exerted a constant orthodontic force for two weeks under water immersion conditions. The orthodontic force of Eucommia elastomer was found to be similar to the orthodontic force exerted by the multi-bracket orthodontic appliance with 0.019 × 0.025 in nickel–titanium wire. These results suggest that the Eucommia elastomer has possibly become one of the more useful materials to form thermoplastic orthodontic appliance exerting low continues orthodontic force.
Keywords: orthodontic appliance; thermoplastics; Eucommia ulmoides; orthodontic wires orthodontic appliance; thermoplastics; Eucommia ulmoides; orthodontic wires
Graphical Abstract

Share and Cite

MDPI and ACS Style

Inoue, S.; Yamaguchi, S.; Uyama, H.; Yamashiro, T.; Imazato, S. Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study. Materials 2020, 13, 4085. https://doi.org/10.3390/ma13184085

AMA Style

Inoue S, Yamaguchi S, Uyama H, Yamashiro T, Imazato S. Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study. Materials. 2020; 13(18):4085. https://doi.org/10.3390/ma13184085

Chicago/Turabian Style

Inoue, Sayuri, Satoshi Yamaguchi, Hiroshi Uyama, Takashi Yamashiro, and Satoshi Imazato. 2020. "Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study" Materials 13, no. 18: 4085. https://doi.org/10.3390/ma13184085

APA Style

Inoue, S., Yamaguchi, S., Uyama, H., Yamashiro, T., & Imazato, S. (2020). Orthodontic Aligner Incorporating Eucommia ulmoides Exerts Low Continuous Force: In Vitro Study. Materials, 13(18), 4085. https://doi.org/10.3390/ma13184085

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop