Next Article in Journal
Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature
Previous Article in Journal
A Smart Green Building: An Environmental Health Control Design
Open AccessArticle

Cup Anemometers’ Loss of Performance Due to Ageing Processes, and Its Effect on Annual Energy Production (AEP) Estimates

1
IDR/UPM, ETSIA, Universidad Politécnica de Madrid (Polytechnic University of Madrid), Pza. del Cardenal Cisneros 3, Madrid 28040, Spain
2
Aerospace Propulsion and Fluid Mechanics Department, ETSIA, Universidad Politécnica de Madrid (Polytechnic University of Madrid), Pza. del Cardenal Cisneros 3, Madrid 28040, Spain
3
Department of Aerospace Materials and Production, ETSIA, Universidad Politécnica de Madrid (Polytechnic University of Madrid), Pza. del Cardenal Cisneros 3, Madrid 28040, Spain
*
Author to whom correspondence should be addressed.
Energies 2012, 5(5), 1664-1685; https://doi.org/10.3390/en5051664
Received: 22 March 2012 / Revised: 30 April 2012 / Accepted: 16 May 2012 / Published: 23 May 2012
The deviation of calibration coefficients from five cup anemometer models over time was analyzed. The analysis was based on a series of laboratory calibrations between January 2001 and August 2010. The analysis was performed on two different groups of anemometers: (1) anemometers not used for any industrial purpose (that is, just stored); and (2) anemometers used in different industrial applications (mainly in the field—or outside—applications like wind farms). Results indicate a loss of performance of the studied anemometers over time. In the case of the unused anemometers the degradation shows a clear pattern. In the case of the anemometers used in the field, the data analyzed also suggest a loss of performance, yet the degradation does not show a clear trend. A recalibration schedule is proposed based on the observed performances variations. View Full-Text
Keywords: anemometer calibration; cup anemometer; MEASNET; Annual Energy Production (AEP); recalibration schedule; anemometer wear and tear; anemometer loss of performance anemometer calibration; cup anemometer; MEASNET; Annual Energy Production (AEP); recalibration schedule; anemometer wear and tear; anemometer loss of performance
Show Figures

Figure 1

MDPI and ACS Style

Pindado, S.; Barrero-Gil, A.; Sanz, A. Cup Anemometers’ Loss of Performance Due to Ageing Processes, and Its Effect on Annual Energy Production (AEP) Estimates. Energies 2012, 5, 1664-1685.

AMA Style

Pindado S, Barrero-Gil A, Sanz A. Cup Anemometers’ Loss of Performance Due to Ageing Processes, and Its Effect on Annual Energy Production (AEP) Estimates. Energies. 2012; 5(5):1664-1685.

Chicago/Turabian Style

Pindado, Santiago; Barrero-Gil, Antonio; Sanz, Alfredo. 2012. "Cup Anemometers’ Loss of Performance Due to Ageing Processes, and Its Effect on Annual Energy Production (AEP) Estimates" Energies 5, no. 5: 1664-1685.

Find Other Styles

Article Access Map by Country/Region

1
Only visits after 24 November 2015 are recorded.
Search more from Scilit
 
Search
Back to TopTop