Article

Flexibility Control in Autonomous Demand Response by Optimal Power Tracking

by
Klaus Rheinberger
1,2,*,
Peter Kepplinger
1,2 and
Markus Preißinger
1,2
1
Energy Research Center, Vorarlberg University of Applied Sciences, Hochschulstraße 1, 6850 Dornbirn, Austria
2
Josef Ressel Centre for Intelligent Thermal Energy Systems, Vorarlberg University of Applied Sciences, Hochschulstraße 1, 6850 Dornbirn, Austria
*
Author to whom correspondence should be addressed.
Energies 2021, 14(12), 3568; https://doi.org/10.3390/en14123568
Submission received: 6 May 2021 / Revised: 2 June 2021 / Accepted: 9 June 2021 / Published: 15 June 2021
(This article belongs to the Special Issue Modern Computational Methods for Flexibility Control)

Abstract

:
In the regime of incentive-based autonomous demand response, time dependent prices are typically used to serve as signals from a system operator to consumers. However, this approach has been shown to be problematic from various perspectives. We clarify these shortcomings in a geometric way and thereby motivate the use of power signals instead of price signals. The main contribution of this paper consists of demonstrating in a standard setting that power tracking signals can control flexibilities more efficiently than real-time price signals. For comparison by simulation, German renewable energy production and German standard load profiles are used for daily production and demand profiles, respectively. As for flexibility, an energy storage system with realistic efficiencies is considered. Most critically, the new approach is able to induce consumptions on the demand side that real-time pricing is unable to induce. Moreover, the pricing approach is outperformed with regards to imbalance energy, peak consumption, storage variation, and storage losses without the need for additional communication or computation efforts. It is further shown that the advantages of the optimal power tracking approach compared to the pricing approach increase with the extent of the flexibility. The results indicate that autonomous flexibility control by optimal power tracking is able to integrate renewable energy production efficiently, has additional benefits, and the potential for enhancements. The latter include data uncertainties, systems of flexibilities, and economic implementation.

1. Introduction

The main goal of an electrical energy system is to maintain a productive and stable operation, i.e., to match production and consumption by controlling flexibilities efficiently. We define a flexibility as the feasibility to change the power profile over a certain time range. Historically, to a great extent, flexibilities were available on the production side. The growing share of renewable energy sources (RES) is leading to a reduction in those, putting the question of how to control flexibilities on the demand side into focus. Demand side flexibilities offer the possibility of changing consumption to deviate from demand, including time-shifting, peak-shaving, and load-leveling potentials. For an example of a current production side flexibility analysis, we refer to [1], who investigated the value of operating nuclear power plants more flexibly in view of system security after the loss of a production unit.
A possible way to control demand side flexibilities is to incentivize such changes via demand response (DR) programs. For recent comprehensive reviews of DR, we refer to [2,3,4]. Here, we give a short overview of DR approaches that relate to the method proposed here.
Autonomous DR uses one-way communication to the consumers and thereby protects privacy and keeps computational efforts low. For example, real-time pricing (RTP), which is offered by multiple utilities, uses time-dependent prices as signals to incentivize changes in consumers’ consumption profiles. According to the prices received, consumers optimize their cost over a given time period autonomously. An application of RTP to thermal flexibilities is given in [5], where Kepplinger et al. autonomously control electric domestic hot water heaters using expected demand and a pseudo cost function. Koltsaklis et al. [6] present a price-based framework for smart homes that integrates several types of flexibilities and energy sources. It results in a mixed-integer LP that includes peak load constraints. Field tests of autonomously controlled flexibilities using RTP were performed for example in [7,8]. RTP has, however, been shown to be problematic from a stability and optimality perspective, cf. the recent works [9,10,11,12]. We will illustrate and explain these problems hereafter.
For the electric utility, RTP and other signal-based autonomous DR programs give rise to the bilevel optimization problem of finding the best (price) signal to propagate. The signal is optimal when the induced individual consumptions in total match the desired production as close as possible. Lübkert et al. [13] studied the RTP bilevel optimization problem of controlling domestic electric water heaters to track a given power profile. They show that with the optimal price signal, consumption profiles are induced, which differ significantly, although leading to the same costs. The authors concluded that the approach is not suitable to control the load of a single water heater. They proposed a method for generating price functions that adapted the aggregated consumption of many water heaters approximately to a desired profile. Kovács [14] introduced a bilevel programming approach to RTP in an electric grid of prosumers (followers) and a retailer (leader). The prosumers optimize their controllable load and their battery charging schedule to maximize their utility and minimize their costs. The so-called “optimistic” assumption was adopted in this publication, i.e., if a follower has more than one optimal solution according to its own objective, then the most favorable for the leader is chosen. This assumption favors effectively constant prices and clashes with the autonomy of the followers’ optimization. Other works [15,16] apply the optimistic assumption as well. In a recent work [17], Kis et al. investigated the problems of the optimistic assumption and propose a way to overcome them by solving the pessimistic variant instead.
To give a simple illustration of the questionability of the optimistic assumption, consider a lossless energy storage system (ESS) and a consumer in need to charge it to some fixed amount within some fixed time. For a flat, i.e., with a constant price over this time, the solution space of the optimization coincides with the whole feasibility region, as every feasible consumption has the same cost. The flexibility cannot be controlled. However, by applying the optimistic assumption, this price signal can induce any desired consumption of the leader as long as it is feasible.
Game-theoretic DR approaches are given, e.g., in [18,19,20,21]. Yang et al. [19] can induce any feasible consumption with an appropriate price by using non-linear utility functions for the customers. The approach of Mohsenian-Rad et al. [18] leads to a distributed algorithm which needs message exchanges between consumers.
Related to game-theoretic approaches are other complex algorithms using two-way communications, market-based mechanisms, and distributed computing [22,23,24,25]. The communication between customers is often price-based. Hu et al. [22] consider prosumers in a distribution grid. The prosumers send their consumption schedules to a central intelligence, which optimizes prices, that are subsequently sent to all prosumers, who return new optimal schedules, and so on. Moldernik et al. [26] propose a control strategy that consists of profile prediction, in advance global planning and real-time local control. Their approach is an iterative, distributed algorithm led by a global controller. Worthmann et al. [27] and Braun et al. [28] used non-price-based methods to control distributed flexibilities.
Cai et al. [29] apply a two-level flexibility control mechanism for building thermal loads that, at one level, maximizes the operational flexibility over the next hour and, at the other level, optimizes the operational costs of participating in energy and frequency markets. Though this approach is eventually price-based, it does not lead to marginal load trajectories as regulation capacities are needed for participation in the frequency market.
In centralized DR frameworks like [30,31], a central intelligence system uses information about the current state of every consumer’s devices and demand, computes an optimal matching, and finally operates the consumers’ flexibilities according to the optimal plan. However, privacy and scalability problems emerge in centralized DR approaches.
Non-price-based DR approaches were also applied by Wang et al. [32], who formulated an electrical load tracking problem that includes power generation and consumption as flexibilities. Hindi et al. [33] propose a framework for reducing energy imbalances in the grid by jointly controlling the supply side and the demand side. They designed a model predictive controller for tracking a time-varying reference signal. The control scheme results in a quadratic program, uses knowledge of the plant model and feedback information from the demand side, and thus, is not autonomous. Logenthiran et al. [34] use a desired load curve to control shiftable loads in an RTP DR program. The desired load curve is chosen in a way to be inversely proportional to electricity market prices. Callaway [35] uses power tracking in a thermal control setting to mitigate RES power fluctuations. However, the control is used to produce short-time scale responses of one hour or less.
The difficulties of RTP in autonomous DR and the successful application of other signals and tracking in non-autonomous DR settings motivates the idea of also using different signals and tracking in the setting of autonomous DR. We consider an ESS as the consumer’s flexibility and propose to use a production power signal to circumvent the non-linear bilevel optimization of autonomous RTP. Each consumer’s ESS should track the production power signal as closely as possible in the L1-norm (sum of absolute values). We term this approach optimal power tracking (OPT) and reason it in the following way: A flexibility defines a set of power profiles that are made feasible by the flexibility. We call this set the flexibility region of the ESS. Cost optimization according to a given price signal is a linear program (LP) and thus results in a consumption profile that lies at the boundary of the flexibility region.The interior of the flexibility region is never occupied by cost optimal solutions. This fact is reflected by the observation that multiples of a price signal lead to the same optimal consumption. Thus, price signals cannot parameterize the complete feasibility region. RTP is therefore inefficient for matching consumption to a given production because it typically does not lead to a consumption that matches production best. By design, OPT overcomes the boundary restriction and uses the entire flexibility region. With OPT, consumption profiles are inducible, which are not inducible by means of RTP. In its L1-norm (sum of absolute values) formulation, OPT is a non-linear optimization problem. It can, however, be reformulated as an LP.
On the basis of this reasoning, we hypothesize that:
OPT can control demand side flexibilities more efficiently than RTP.
In order to test this hypothesis, we compare the two algorithms over one year regarding the indicators imbalance energy (measured as L1-distance to production), peak consumption, storage variation and storage losses.
In summary, previous studies have already successfully applied the tracking of power signals in the realm of DR. However, they typically did not question prices as an incentive signal. To the best of the authors’ knowledge, this paper is the first to investigate the use of power signals from a system operator to consumers in an autonomous DR setting. Furthermore, a quantitative comparison of OPT with RTP in the same DR setting regarding multiple indicators has been missing in the literature. Thus, the main objective of this study is to provide a fair comparison of OPT and RTP for the control of autonomous flexibilities concerning cost and stability indicators, computational effort and extensibility.
The rest of the paper is organized as follows: In Section 2, we formalize the consumer’s optimization problems RTP and OPT using a simple electrical energy system model and illustrate the corresponding solution structures in a simplified 2D model. We specify the production, price and demand data, and give the parameter configuration for comparison. In Section 3, the resulting indicator values of RTP and OPT are given for different ESS capacities. Section 4 concludes the paper with a discussion of the findings and suggestions for next steps.

2. Materials and Methods

In this section, we model a simple but typical DR setting. Both optimization approaches, RTP and OPT, are presented in detail. They aim to control the consumer’s flexibility in order to match consumption to a given production without changing the consumers known demand. Note that in this setting the consumer does not experience any discomfort as the demand side flexibility only consists of the ESS and no customer behavior, represented by the given demand profile, is changed. We illustrate the flexibility and the optimization approaches to gain an understanding of their (dis-)advantages. Finally, we state the simulation settings that were used for the quantitative comparisons of RTP with OPT.

2.1. Energy System Model

For the sake of simplicity and interpretability, we consider an electric utility with only one consumer whose data are known deterministically. Our electrical energy system model is depicted in Figure 1, and a list of the symbols and units used is given in Table 1 at the end of this section. Its main characteristics correspond to the model used by van de Ven et al. [36].
Time is measured in h, power in kW, energy in kWh, and costs in EUR. Without loss of generality, we use a unit time step Δ t = 1 h. Consumption is optimized over one day, i.e., over N = 24 periods. The initial and end time points of the periods are 0 , Δ t , , N Δ t . Periods are indexed by their initial time points t T = { 0 , Δ t , , ( N 1 ) Δ t } . The initial state of charge (SOC) of the ESS for the time point t = 0 is given as S 0 . Power values are constant over each period. The utility has an ex ante known production profile p = ( p t ) t T . Likewise, the consumer faces a known demand profile d = ( d t ) t T over the same day. The ESS of the consumer has efficiency factors η in and η out for charging and discharging, respectively. Before the day starts, the utility sends a signal σ = ( σ t ) t T to the consumer, which in turn is used by the consumer to determine the following optimal power profiles:
  • Consumption c = ( c t ) t T ,
  • Direct consumption c dir = ( c t dir ) t T ,
  • Storage charging power s in = ( s t in ) t T ,
  • Storage discharging power s out = ( s t out ) t T .
The efficiency factors, the initial SOC, and the charging and discharging powers determine the SOC S t at the period ends t = Δ t , , N Δ t . The consumption schedule of a day is given by the power profiles ( c , c dir , s in , s out ) . A consumption schedule is restricted by the following constraints:
  • Lower and upper bounds for c t , c t dir , s t in , and s t out for all periods t T :
    c min c t c max
    c min dir c t dir c max dir
    s min in s t in s max in
    s min out s t out s max out
  • Power conservation at the junctions for all periods t T :
    c t = c t dir + s t in
    d t = c t dir + s t out
  • Lower and upper bounds for the SOC
    S t = S 0 + τ = 0 t Δ t ( η in s τ in η out 1 s τ out ) Δ t
    for all periods t = Δ t , , N Δ t :
    S min S t S max
  • Fixed SOC S end at the end of the day:
    S 24 = S end
  • In order to prevent charging and discharging at the same time, binary variables β t in and β t out are introduced to formulate the constraints:
    s t in s max in β t in
    s t out s max out β t out
    β t in + β t out 1
    for each period t = Δ t , , N Δ t .
Compared with the real situation, this model does not consider uncertainties in production, in the initial SOC, in the efficiency factors of the ESS, and in consumer demand. Nevertheless, the model is appropriate and sufficient for gaining a deeper understanding of the implications of flexibility control via price and power signals.
The symbols and units used for the energy system model are summarized in Table 1.

2.2. Real-Time Pricing

In the RTP regime, a price signal σ = π with units EUR/kWh is sent by the electric utility, as the system operator, to the consumer’s controller. The controller solves:
min . t T π t c t Δ t
subject to all constraints (1) to (11). The decision variables of this LP are comprised of the consumer schedule ( c , c dir , s in , s out ) and the auxiliary binary variables β in = ( β t in ) t T and β out = ( β t out ) t T .
Typically, spot market prices are positively correlated with energy production. With such price signals, cost minimization leads to consumption profiles that correlate negatively with production. For peak shaving, this effect is desirable, as can be seen for example in the work of Widergren et al. [37]. In this paper, however, the objective is to match consumption with production. Therefore, we use pseudo-prices that perfectly anticorrelate with production. More precisely, our price signal π is derived from the production p by first standardizing p to zero mean and unit standard deviation, then multiplying it with 1 , and finally subtracting its minimum value, such that π 0 .
An LP can be visualized in the space of the decision variables by the price vector π and the feasibility region. The feasibility region of the cost minimization problem (12) determines the flexibility region that we introduced in Section 1. In the energy system model above, we consider various power profiles of production, demand and consumption over one day, which are constant during each time period. In this setting, a power profile is a vector in R n . As a depictable example for a flexibility region, we now consider only two hours together with a lossless ESS of a capacity of 5 kWh, an initial SOC of 0 kWh and a maximum charging power 5 kW. The final SOC S 2 is not fixed. In this setting, for the sake of illustrating it in two dimensions, direct consumption is made possible by enabling concurrent charging and discharging, i.e., by dropping the constraints (10) to (11). The complete consumption c = ( c 0 , c 1 ) flows into the ESS, and the given demand d = ( 1 , 3 ) is taken completely from the ESS. Figure 2 shows the corresponding flexibility region as a convex set in R 2 .
Figure 2 also reveals the known fact that any solution of an LP lies on the boundary of the feasibility region. Changing the price signal changes the resulting boundary point. More specifically, the LP solver always returns a vertex of the flexibility region. The interior of the flexibility region is unreachable by RTP. This leads to the question of how one can induce an inner point as the consumption resulting from autonomous optimization. Our approach to this problem consists of sending a power tracking signal to the household and is detailed in the next subsection.

2.3. Optimal Power Tracking

In the OPT regime, the system operator, e.g., the electric utility, estimates the daily aggregate demand energy of the household and runs a production profile p whose aggregate energy equals the estimated aggregate demand energy of the household and is otherwise beneficial for the utility. This power profile is sent as signal σ = p to the household whose device solves the L1-norm, non-linear optimization tracking problem:
min . t T | p t c t | Δ t
subject to all constraints (1) to (11). Again, the decision variables are comprised of the consumer schedule ( c , c dir , s in , s out ) and the auxiliary binary variables β in and β out .
Figure 3 shows that with OPT, interior points of the consumer’s flexibility region can be induced as consumptions. If the tracking signal p lies outside the flexibility region, then the OPT solution lies at the boundary, but it need not be a vertex as in the RTP regime.
The optimization problem (13) corresponds to minimizing the L1-norm of the difference vector p c and is thus non-linear. It can, however, be reformulated as the LP:
min . t T a t Δ t
with the additional constraints a t p t c t a t using the auxiliary variables a t 0 for all times t T .
The L1-norm of ( p c ) Δ t can be interpreted economically as the amount of energy and thus money needed to balance the daily mismatch between production and consumption. For this reason, we use the L1-norm. Alternative norms like the L2-norm (Euclidean norm) are, however, also capable of inducing interior points as consumption profiles and can be argued to have their advantages.
We used the following simulation settings to calculate four important indicators and thereby test the hypothesis stated in the introduction.

2.4. Simulation Settings

To simulate complete renewable energy production, the total solar and wind generation of 2018 in Germany [38] is scaled to the production profiles of our model. The 2018 standard load profiles of the Stromnetz Berlin [39] are rescaled to an aggregate yearly household demand of 1000 kWh before using them for the demand profiles. The energy of each daily production profile equals the corresponding aggregate demand energy. Both efficiency factors of the ESS are set to η in = η out = 0.95 . Its capacity is varied to reflect different storage settings: S max = 0, 0.25, 0.5, 1, 2, 4, 6, 8, and 10 kWh. All lower bounds in the electrical consumption model are chosen to be zero: c min = c min dir = s min in = s min out = 0 kW. The following upper bounds are used: c max = c max dir = 35 kW, s max in = s max out = C · S max kW with a battery C-rate of C = 1 2 h . The initial and final SOC values are both set to the respective mean capacity: S 0 = S end = 0.5 · S max , in order to have a continuous SOC-transition between days.

3. Results

The LPs were solved in Python using the Gurobi Optimizer [40]. The computations were performed on a laptop with an Intel Core i7-4700MQ 3144 MHz CPU. For a given parameter setting, the RTP computations needed approximately 7.5 s for the simulation year. The LP of each day involved 144 variables (96 continuous and 48 binary) and 169 constraints. The respective OPT computations needed approximately 9.0 s. The LP of each day involved 168 variables (120 continuous and 48 binary) and 217 constraints. The respective benchmark computations needed approximately 1.5 s.
To compare the effects of RTP and OPT over a complete year, the following indicators were computed for each day:
  • Defined as the sum of absolute differences between production and consumption, the distance to production (D2P) measures the amount of imbalance energy and is thereby relevant for the costs of the electric utility:
    D 2 P = p c 1 Δ t = t T | p t c t | Δ t
  • Defined as the maximum consumption, peak consumption (PC) is relevant for the stability of transmission and distribution networks:
    PC = max t T c t
  • Defined as the sum of absolute consumption changes, storage variation (SV) is relevant for the lifetime of the ESS, and thus, for the consumer’s costs:
    SV = t T | S t S t 1 |
  • Defined as the energy loss of the ESS, storage loss (SL) is also relevant for the consumer’s costs, and is an important indicator for energy efficiency:
    SL = ( 1 η in ) t T s t in Δ t + ( 1 η out 1 ) t T s t out Δ t
When the consumer does not operate an ESS, consumption coincides with demand. These consumption profiles served as benchmarks for D2P and PC.
Figure 4 shows histograms of the indicator values for S max = 2.0 .
The objective of OPT is the minimization of D2P. Therefore, it is not surprising that OPT can decrease D2P to almost zero kWh. The D2P values of RTP, however, are even higher than the benchmark of no flexibility. This is partly due to the non-optimal price signal used. However, even with a bilevel-optimized price signal, RTP could have only induced boundary points of the consumer’s flexibility region. Thus, in all cases where the given production lies inside this region, there exists no price signal that could induce this production, whereas OPT will always induce a perfectly matching consumption.
The results for SV and SL are related because higher storage usage leads to higher losses. Both results show significantly better values for OPT compared to RTP. This is because the production signals that OPT tries to follow have less variation than the RTP optimal consumption, which accumulate at times of low prices.
The PC values are not significantly altered by OPT compared to the benchmark. The PC values of RTP optimal consumption, on the other hand, are more than five times higher. This adverse effect of RTP occurs for the same reasons as described before for all kinds of prices, regardless of whether they are bilevel-optimized.
Figure 5 gives the mean and standard deviation values of all indicators for different ESS capacities.
For all capacities greater than 1 kWh, RTP results in adverse indicator values compared to the benchmark and OPT. With increasing capacities, the discrepancies between RTP on the one hand and OPT and the benchmark on the other hand increase.
All RTP indicators increase with ESS capacity until they stop at some saturation values. The saturation of RTP is due to the finite aggregate demand. All OPT indicators saturate earlier and at lower more favorable values. The saturation of OPT is due to the fact that a higher capacity corresponds to a larger flexibility region which is of no additional use if the production is already feasible, i.e., inside the flexibility region. This effect can be seen best in Figure 5a, where D2P starts to vanish from S max = 2 kWh on.
As mentioned in Section 2, no uncertainties were considered, and all data were assumed to be perfectly known in advance. The results of the deterministic RTP and OPT optimizations are thus only approximately realistic. However, it follows that consumptions that are induced by OPT and lie inside the flexibility region are more robust against uncertainties in demand and initial SOC than the vertex solutions of RTP.
Although the L1-norm of the OPT approach can be interpreted as balancing energy, since it is cost-relevant for the electric utility, the OPT approach does not necessarily have a straightforward economic implication for the consumer. Instead of directly transferring balancing energy costs to the consumer, the consumer could be rewarded by a reduced tariff for allowing the system operator to control the ESS via OPT.

4. Conclusions

In this paper, we analyzed the shortcomings of price signals in autonomous DR and inferred dropping prices as a means to indirectly induce consumption changes. We suggest, instead, to directly use the desired power profile as a signal, which shall be tracked by the consumer’s device. This new OPT approach is able to control the total flexibility. It can induce consumptions on the demand side that RTP cannot induce, and additionally, shows multiple system benefits.
For a comparison of OPT with RTP in a standard DR setting, German renewable energy production and German standard load profiles were used for daily production and demand profiles, respectively. The flexibility of the consumer consisted of an ESS with realistic efficiencies. Imbalance energy, peak consumption, storage variation and storage losses were analyzed for daily optimizations over a complete year under perfect information assumptions. The extent of flexibility, given by the ESS capacity, proved to be an important sensitivity parameter for the chosen indicators.
The main findings of this study are outlined below:
  • For the autonomous control of demand side flexibilities, OPT shows favorable characteristics for all indicators, which reflect the matching of production and consumption, the costs of the electric utility, stability of transmission and distribution networks, the consumer’s costs and energy efficiency.
  • The RTP performance is counterproductive, even inferior compared to the benchmark case of no flexibility. Similar adverse effects of price-based DR were recently reported in [9,10,11,12].
  • OPT overcomes these problems without the need for additional communication or computation efforts. The proposed approach can be implemented using the same hardware and software as for RTP. We refer to [7,8] as examples for RTP implementations using embedded systems.
  • The advantages of OPT compared to RTP increase with the extent of the flexibility. The maximal potential of OPT occurs at storage capacities where the flexibility region encompasses the production profile. The adverse characteristics of RTP keep increasing with storage capacity until the consumer specific constraints stop them.
This paper presents a proof of concept for the new OPT approach in autonomous DR. Some limitations should be noted, and several suggestions for enhancements and future studies can be stated:
We did not use bilevel-optimized prices for the comparison of RTP to OPT because the optimistic assumption of bilevel optimization has recently been shown to be questionable [17]. Furthermore, even bilevel-optimized prices are not able to induce inner points of the consumer’s flexibility region. Nevertheless, a quantitative comparison to bilevel-optimal prices would be interesting.
Although the results under deterministic assumptions show that OPT outperforms the RTP approach with regards to all indicators, this remains to be tested in a more realistic setting including uncertainties. In a setting with partly stochastic boundaries of the flexibility region, one could increase the robustness of the OPT-optimized consumption schedule by including penalty terms in the objective function that maximize the distance to uncertain boundaries.
Another enhancement of the OPT approach could be to use model predictive control strategies that take into account, e.g., weather forecasts and occupant behavior. Especially for specific applications or systems like buildings and electric vehicle fleets that comprise several components and flexibilities, this could improve performance.
With time-dependent penalty coefficients, the OPT algorithm could be extended to stress times where the matching between consumption and power signal is reinforced or attenuated.
When more than one flexibility is controlled with OPT and the aggregate consumption is matched to a given production, the OPT approach is scalable in different ways to full system sizes. We give two ideas in this regard:
  • The same signal is sent out to all consumers’ controllers. Each controller rescales the received power signal to the total daily household demand.
  • If the flexibilities and demands of consumers can be estimated, individual tracking signals can be used, which can be better matched by the consumers’ controllers.
The OPT approach can be readily generalized to settings that include other flexibilities like thermal storages, shiftable or scalable loads, occupant comfort ranges, and electric vehicles. Aggregations of these flexibilities, e.g., in buildings and distribution grids, can be handled by considering the Minkowski sum of the individual flexibilities, cf. [41,42].
This study did not compare RTP with OPT in monetary terms but used technical indicators only. In addition to savings in balancing energy, with OPT the system operator faces increased freedom in specifying the production profile. Cheaper purchases, power grid-friendly loads and increased integration of RES lead to competitive advantages, parts of which could be passed to the consumer via a cheaper tariff. The monetary quantification of these multiple benefits in specific settings should be considered in future studies.

Author Contributions

Conceptualization, K.R. and P.K.; methodology, K.R.; software, K.R.; validation, P.K. and M.P.; formal analysis, M.P.; data curation, K.R.; writing—original draft preparation, K.R.; writing—review and editing, P.K. and M.P.; project administration, M.P.; funding acquisition, M.P. All authors have read and agreed to the published version of the manuscript.

Funding

The financial support by the Austrian Federal Ministry for Digital and Economic Affairs and the National Foundation for Research, Technology and Development and the Christian Doppler Research Association is gratefully acknowledged. The project was also partly funded by the federal state of Vorarlberg (Austria) and the “European Regional Developement Fund”. The financial support of the illwerke vkw Endowed Professorship for Energy Efficiency at FHV is greatly acknowledged.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The used data sources are referenced in Section 2.4.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

The following abbreviations are used in this manuscript:
DRdemand response
RESrenewable energy sources
ESSenergy storage system
RTPreal-time pricing
LPlinear program, linear optimization problem
OPToptimal power tracking
D2Pdistance to production
PCpeak consumption
SVstorage variation
SLstorage loss
SOCstate of charge
L1-normsum of absolute values, i = 1 n | x i | for x R n
L2-normEuclidean norm, i = 1 n | x i | 2 for x R n

References

  1. Hadri, M.; Trovato, V.; Bialecki, A.; Merk, B.; Peakman, A. Assessment of High-Electrification UK Scenarios with Varying Levels of Nuclear Power and Associated Post-Fault Behaviour. Energies 2021, 14, 1780. [Google Scholar] [CrossRef]
  2. Shewale, A.; Mokhade, A.; Funde, N.; Bokde, N.D. An Overview of Demand Response in Smart Grid and Optimization Techniques for Efficient Residential Appliance Scheduling Problem. Energies 2020, 13, 4266. [Google Scholar] [CrossRef]
  3. Jordehi, A.R. Optimisation of demand response in electric power systems, a review. Renew. Sustain. Energy Rev. 2019, 103, 308–319. [Google Scholar] [CrossRef]
  4. Paterakis, N.G.; Erdinç, O.; Catalão, J.P.S. An overview of Demand Response: Key-elements and international experience. Renew. Sustain. Energy Rev. 2017, 69, 871–891. [Google Scholar] [CrossRef]
  5. Kepplinger, P.; Huber, G.; Petrasch, J. Autonomous optimal control for demand side management with resistive domestic hot water heaters using linear optimization. Energy Build. 2015, 100, 50–55. [Google Scholar] [CrossRef]
  6. Koltsaklis, N.; Panapakidis, I.P.; Pozo, D.; Christoforidis, G.C. A Prosumer Model Based on Smart Home Energy Management and Forecasting Techniques. Energies 2021, 14, 1724. [Google Scholar] [CrossRef]
  7. Kepplinger, P.; Huber, G.; Petrasch, J. Field testing of demand side management via autonomous optimal control of a domestic hot water heater. Energy Build. 2016, 127, 730–735. [Google Scholar] [CrossRef]
  8. Faessler, B.; Kepplinger, P.; Petrasch, J. Field testing of repurposed electric vehicle batteries for price-driven grid balancing. J. Energy Storage 2019, 21, 40–47. [Google Scholar] [CrossRef]
  9. Li, Y.; Ng, B.L.; Trayer, M.; Liu, L. Automated Residential Demand Response: Algorithmic Implications of Pricing Models. IEEE Trans. Smart Grid 2012, 3, 1712–1721. [Google Scholar] [CrossRef]
  10. Kühnbach, M.; Stute, J.; Klingler, A.L. Impacts of avalanche effects of price-optimized electric vehicle charging—Does demand response make it worse? Energy Strategy Rev. 2021, 34, 100608. [Google Scholar] [CrossRef]
  11. Faessler, B.; Schuler, M.; Preißinger, M.; Kepplinger, P. Battery Storage Systems as Grid-Balancing Measure in Low-Voltage Distribution Grids with Distributed Generation. Energies 2017, 10, 2161. [Google Scholar] [CrossRef] [Green Version]
  12. Ireshika, M.A.S.T.; Preissinger, M.; Kepplinger, P. Autonomous Demand Side Management of Electric Vehicles in a Distribution Grid. In Proceedings of the 2019 7th International Youth Conference on Energy (IYCE), Bled, Slovenia, 3–6 July 2019; pp. 1–6. [Google Scholar] [CrossRef]
  13. Lübkert, T.; Venzke, M.; Vo, N.V.; Turau, V. Understanding price functions to control domestic electric water heaters for demand response. Comput. Sci. Res. Dev. 2018, 33, 81–92. [Google Scholar] [CrossRef]
  14. Kovács, A. Bilevel programming approach to demand response management with day-ahead tariff. J. Mod. Power Syst. Clean Energy 2019, 7, 1632–1643. [Google Scholar] [CrossRef] [Green Version]
  15. Anjos, M.F.; Brotcorne, L.; Gomez-Herrera, J.A. Optimal setting of time-and-level-of-use prices for an electricity supplier. Energy 2021, 225, 120517. [Google Scholar] [CrossRef]
  16. Kovacevic, R.M.; Vo, N.V.; Haunschmied, J. Bilevel approaches for distributed DSM using internal individualized prices. In Proceedings of the 2017 IEEE International Conference on Smart Grid Communications (SmartGridComm), Brussels, Belgium, 17–20 October 2017; pp. 521–526. [Google Scholar] [CrossRef]
  17. Kis, T.; Kovács, A.; Mészáros, C. On Optimistic and Pessimistic Bilevel Optimization Models for Demand Response Management. Energies 2021, 14, 2095. [Google Scholar] [CrossRef]
  18. Mohsenian-Rad, A.; Wong, V.; Jatskevich, J.; Schober, R.; Leon-Garcia, A. Autonomous Demand-Side Management Based on Game-Theoretic Energy Consumption Scheduling for the Future Smart Grid. IEEE Trans. Smart Grid 2010, 1, 320–331. [Google Scholar] [CrossRef] [Green Version]
  19. Yang, P.; Tang, G.; Nehorai, A. A game-theoretic approach for optimal time-of-use electricity pricing. IEEE Trans. Power Syst. 2013, 28, 884–892. [Google Scholar] [CrossRef]
  20. Chen, L.; Liu, N.; Li, C.; Wang, J. Peer-to-peer Energy Sharing with Social Attributes: A Stochastic Leader-follower Game Approach. IEEE Trans. Ind. Inform. 2020, 17, 2545–2556. [Google Scholar] [CrossRef]
  21. Yu, M.; Zhang, X.; Jiang, J.; Lee, C.; Hong, S.H.; Wang, K.; Xu, A. Assessing the Feasibility of Game-Theory-Based Demand Response Management by Practical Implementation. IEEE Access 2021, 9, 8220–8232. [Google Scholar] [CrossRef]
  22. Hu, J.; Wu, J.; Ai, X.; Liu, N. Coordinated Energy Management of Prosumers in a Distribution System Considering Network Congestion. IEEE Trans. Smart Grid 2020, 12, 468–478. [Google Scholar] [CrossRef]
  23. Nainar, K.; Pillai, J.R.; Bak-Jensen, B. Incentive Price-Based Demand Response in Active Distribution Grids. Appl. Sci. 2021, 11, 180. [Google Scholar] [CrossRef]
  24. Han, J.; Liu, N.; Shi, J. Optimal Scheduling of Distribution System with Edge Computing and Data-Driven Modeling of Demand Response. J. Mod. Power Syst. Clean Energy 2021. [Google Scholar] [CrossRef]
  25. De Souza Dutra, M.D.; Alguacil, N. Optimal residential users coordination via demand response: An exact distributed framework. Appl. Energy 2020, 279, 115851. [Google Scholar] [CrossRef]
  26. Molderink, A.; Bakker, V.; Bosman, M.; Hurink, J.; Smit, G. Management and control of domestic smart grid technology. IEEE Trans. Smart Grid 2010, 1, 109–119. [Google Scholar] [CrossRef] [Green Version]
  27. Worthmann, K.; Kellett, C.M.; Braun, P.; Grune, L.; Weller, S.R. Distributed and decentralized control of residential energy systems incorporating battery storage. IEEE Trans. Smart Grid 2015, 6, 1914–1923. [Google Scholar] [CrossRef] [Green Version]
  28. Braun, P.; Faulwasser, T.; Grüne, L.; Kellett, C.M.; Weller, S.R.; Worthmann, K. Hierarchical distributed ADMM for predictive control with applications in power networks. IFAC J. Syst. Control 2018, 3, 10–22. [Google Scholar] [CrossRef] [Green Version]
  29. Cai, J. Optimal Building Thermal Load Scheduling for Simultaneous Participation in Energy and Frequency Regulation Markets. Energies 2021, 14, 1593. [Google Scholar] [CrossRef]
  30. Zhong, H.; Xie, L.; Xia, Q. Coupon Incentive-Based Demand Response: Theory and Case Study. IEEE Trans. Power Syst. 2013, 28, 1266–1276. [Google Scholar] [CrossRef]
  31. Parvania, M.; Fotuhi-Firuzabad, M.; Shahidehpour, M. ISO’s Optimal Strategies for Scheduling the Hourly Demand Response in Day-Ahead Markets. IEEE Trans. Power Syst. 2014, 29, 2636–2645. [Google Scholar] [CrossRef]
  32. Wang, Z.; Gao, F.; Zhai, Q.; Guan, X.; Wu, J.; Liu, K. Electrical load tracking analysis for demand response in energy intensive enterprise. IEEE Trans. Smart Grid 2013, 4, 1917–1927. [Google Scholar] [CrossRef]
  33. Hindi, H.; Greene, D.; Laventall, C. Coordinating regulation and demand response in electric power grids using multirate model predictive control. ISGT 2011, 2011, 1–8. [Google Scholar] [CrossRef]
  34. Logenthiran, T.; Srinivasan, D.; Shun, T.Z. Demand side management in smart grid using heuristic optimization. IEEE Trans. Smart Grid 2012, 3, 1244–1252. [Google Scholar] [CrossRef]
  35. Callaway, D.S. Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy. Energy Convers. Manag. 2009, 50, 1389–1400. [Google Scholar] [CrossRef] [Green Version]
  36. Van de Ven, P.M.; Hegde, N.; Massoulié, L.; Salonidis, T. Optimal control of end-user energy storage. IEEE Trans. Smart Grid 2013, 4, 789–797. [Google Scholar] [CrossRef] [Green Version]
  37. Widergren, S.; Marinovici, C.; Berliner, T.; Graves, A. Real-time pricing demand response in operations. In Proceedings of the 2012 IEEE Power and Energy Society General Meeting, San Diego, CA, USA, 22–26 July 2012; pp. 1–5. [Google Scholar] [CrossRef]
  38. Open Power System Data. Data Package Time Series. Version 2019-06-05. 2019. Available online: https://data.open-power-system-data.org/time_series/2019-06-05 (accessed on 11 June 2021).
  39. Standardlastprofile der Stromnetz Berlin GmbH. 2019. Available online: https://www.stromnetz.berlin/netz-nutzen/netznutzer (accessed on 11 June 2021).
  40. Gurobi Optimization, LLC. Gurobi Optimizer Reference Manual. 2021. Available online: https://www.gurobi.com (accessed on 11 June 2021).
  41. Barot, S.; Taylor, J.A. An outer approximation of the Minkowski sum of convex conic sets with application to demand response. In Proceedings of the 2016 IEEE 55th Conference on Decision and Control (CDC), Las Vegas, NV, USA, 12–14 December 2016; pp. 4233–4238. [Google Scholar] [CrossRef]
  42. Barot, S. Aggregate Load Modeling for Demand Response via the Minkowski Sum. Ph.D. Thesis, University of Toronto, Toronto, ON, Canada, 2017. [Google Scholar]
Figure 1. Energy system model: the power transfers between electric utility, ESS and household demand are indicated as solid lines. The dashed lines indicate signal communication (the signal which the electric utility sends to the household and the controller signals).
Figure 1. Energy system model: the power transfers between electric utility, ESS and household demand are indicated as solid lines. The dashed lines indicate signal communication (the signal which the electric utility sends to the household and the controller signals).
Energies 14 03568 g001
Figure 2. RTP in a simplified flexibility region (shaded region). The arrow depicts the price vector π . The contour lines of the cost function are orthogonal to the price vector. The resulting optimal consumption (dark dot) always lies at the boundary of the flexibility region.
Figure 2. RTP in a simplified flexibility region (shaded region). The arrow depicts the price vector π . The contour lines of the cost function are orthogonal to the price vector. The resulting optimal consumption (dark dot) always lies at the boundary of the flexibility region.
Energies 14 03568 g002
Figure 3. OPT in a simplified flexibility region (shaded region). The dark dot depicts the production signal to be tracked. The contour lines of the objective function are lines of constant L1-distance to the production signal. As the latter lies within the flexibility region, it coincides with the consumption returned by the OPT problem.
Figure 3. OPT in a simplified flexibility region (shaded region). The dark dot depicts the production signal to be tracked. The contour lines of the objective function are lines of constant L1-distance to the production signal. As the latter lies within the flexibility region, it coincides with the consumption returned by the OPT problem.
Energies 14 03568 g003
Figure 4. Histograms of indicator values for S max = 2.0.
Figure 4. Histograms of indicator values for S max = 2.0.
Energies 14 03568 g004
Figure 5. Mean and standard deviation values of the indicators D2P, PC, SV, and SL, see (15) to (18), over all days for different ESS capacities S max .
Figure 5. Mean and standard deviation values of the indicators D2P, PC, SV, and SL, see (15) to (18), over all days for different ESS capacities S max .
Energies 14 03568 g005
Table 1. Symbols and units used for the energy system model.
Table 1. Symbols and units used for the energy system model.
SymbolQuantityUnit
tindex of time periodsh
Δ t time steph
Nnumber of time periods
Tset of time periods
p t production during period tkW
σ t signal value during period tkW for OPT
EUR/kWh for RTP
π t price during period tEUR/kWh
c t consumption during period tkW
c min , c max minimum resp. maximum consumptionkW
c t dir direct consumption during period tkW
c min dir , c max dir minimum resp. maximum direct consumptionkW
η in efficiency factor for charging
η out efficiency factor for discharging
s t in storage charging power during period tkW
s t out storage discharging power during period tkW
s min in , s max in min. resp. max. storage charging powerkW
s min out , s max out min. resp. max. storage discharging powerkW
β t in 1 if charging during period t, 0 else
β t out 1 if discharging during period t, 0 else
S 0 initial SOCkWh
S t SOC at the end of period tkWh
d t demand during period tkW
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Rheinberger, K.; Kepplinger, P.; Preißinger, M. Flexibility Control in Autonomous Demand Response by Optimal Power Tracking. Energies 2021, 14, 3568. https://doi.org/10.3390/en14123568

AMA Style

Rheinberger K, Kepplinger P, Preißinger M. Flexibility Control in Autonomous Demand Response by Optimal Power Tracking. Energies. 2021; 14(12):3568. https://doi.org/10.3390/en14123568

Chicago/Turabian Style

Rheinberger, Klaus, Peter Kepplinger, and Markus Preißinger. 2021. "Flexibility Control in Autonomous Demand Response by Optimal Power Tracking" Energies 14, no. 12: 3568. https://doi.org/10.3390/en14123568

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop