Article

Towards Optimal Sustainable Energy Systems in Nordic Municipalities

Energy Engineering, Luleå University of Technology, SE-97187 Lulea, Sweden
*
Author to whom correspondence should be addressed.
Energies 2020, 13(2), 290; https://doi.org/10.3390/en13020290
Submission received: 27 November 2019 / Revised: 20 December 2019 / Accepted: 30 December 2019 / Published: 7 January 2020
(This article belongs to the Section A: Sustainable Energy)

Abstract

:
Municipal energy systems in the northern regions of Finland, Norway, and Sweden face multiple challenges: large-scale industries, cold climate, and a high share of electric heating characterize energy consumption and cause significant peak electricity demand. Local authorities are committed in contributing to national goals on CO2 emission reductions by improving energy efficiency and investing in local renewable electricity generation, while considering their own objectives for economic development, increased energy self-sufficiency, and affordable energy costs. This paper formulates a multi-objective optimization problem about these goals that is solved by interfacing the energy systems simulation tool EnergyPLAN with a multi-objective evolutionary algorithm implemented in Matlab. A sensitivity analysis on some key economic parameters is also performed. In this way, optimal alternatives are identified for the integrated electricity and heating sectors and valuable insights are offered to decision-makers in local authorities. Piteå (Norrbotten, Sweden) is used as a case study that is representative of Nordic municipalities, and results show that CO2 emissions can be reduced by 60% without a considerable increase in total costs and that peak electricity import can be reduced by a maximum of 38%.

1. Introduction

The UNFCCC Paris Agreement aims at strengthening global responses to limit the increase of global average temperature to 1.5 °C above pre-industrial levels. In the EU climate and energy framework the targets set by 2030 on greenhouse gas (GHG) emission reduction, renewable energy share, and energy efficiency improvement are 40% (from 1990 levels), 32%, and 32.5%, respectively [1]. Sweden’s binding target set by 2030 on GHG emission reduction was decided to be 40% from 2005 levels [2]. Global energy-related CO2 emissions continue to increase and have risen by 1.7% to 33.1 GtCO2 in 2018 [3]. Sweden´s territorial CO2 emissions from electricity generation and heating have dropped from a 2005 level of 9.3 MtCO2 and reached 5.38 MtCO2 in 2017 [4].
The project Arctic Energy, funded through the EU-program “Interreg Nord,” was implemented by partner institutions from Finland, Sweden, and Norway between 2016 and 2018, and it provided energy systems analyses and simulations of future scenarios in order to support decision-makers of Nordic municipalities in their efforts to achieve GHG emissions targets and increase energy self-sufficiency, while ensuring secure and affordable energy supply [5]. This work continues the studies performed during the Arctic Energy project and investigates optimal alternatives for sustainable energy systems in Nordic municipalities with a focus on electricity and heating sectors.
Studies on Nordic municipal energy systems generally cover the heating sector, typically presenting the optimization of district heating (DH) systems. They include combined heat and power solutions, integration with industrial excess heat supply, solar heating, thermal energy storage, and investigations into next or 4th generation DH [6,7,8,9]. Further studies look into the potential of balancing intermittent renewable power production with power-to-heat solutions [10,11,12,13] and into the optimization of demand response measures [14]. Other research addresses various system aspects of heating demand and supply for buildings not served by DH. They include investigations into energy efficiency and renovation measures, demand management and user behavior, low or near-zero energy buildings, environmental impacts of biomass heating, and conversion of heating technologies [15,16,17,18].
In the recent past, electric heating shares have been between 70 and 80% in Norway [19], 32% in Finland [20], and 26% in Sweden [21]. Electric heating demand contributes to high peak electricity demands in the Nordic electricity sector, as illustrated by the Swedish case: minimum electricity consumption in Sweden was 8.6 GW on 16th July 2017, and maximum was 26.6 GW on 5th January 2017 [22]. Sweden´s responsible authority for the power transmission system (Svenska Kraftnät) expects capacity bottlenecks in the electricity supply of Swedish cities in the near future [23,24]. A typical medium size municipality in Sweden could reduce the annual electricity consumption by 10%, and the peak electricity demand by 20%, by converting from electric to non-electric heating [25].
Approaches to optimize energy systems have become more diverse and the number of studies into optimal solutions to support local decision-making processes has been increasing. Single-objective optimization methods typically focus on minimizing costs and provide the single best solution for one scenario, whereas multi-objective evolutionary algorithms generate a large number of optimal trade-off alternatives for conflicting objectives, including minimizing costs and reducing GHG emissions, maximizing intermittent renewable capacities, and minimizing curtailing and system losses. Optimal alternatives can then be subjected to multi-criteria decision-making methods in order to analyze a number of attributes [26,27,28]. Multi-Agent systems have also been proposed to model behavior and interactions between agents, which are key elements to generate robust, scalable, and context-aware energy optimization solutions [29]. Modelling tools for community scale energy systems and energy systems with large shares of variable renewables have been reviewed in [30,31,32,33].
EnergyPLAN is an advanced simulation tool, developed by Aalborg University [34], which allows the integration of the major sectors of any energy system (electricity, heat, transport, and industry) and supports the modelling of a stepwise transition to a sustainable energy system. EnergyPLAN has been applied in many instances at national, regional, and city level as well as on off-grid systems on islands [35,36,37,38,39,40,41]. Researchers have interfaced EnergyPLAN with optimization methods to find optimal solutions for multi-objective optimization problems. Bjelic et al. [42] analyzed the impact of the EU 2030 framework on the costs of the national energy system of Serbia. The approach of Mahbub et al. [43] provided an additional set of optimal solutions for the case of Aalborg municipality. Prina et al. [44] devoted particular attention to the analysis of energy efficiency in buildings. Thellufsen et al. [45] investigated a DH scenario in the Irish energy system and utilized the hourly simulation capability of EnergyPLAN in combination with the Irish energy system model, which is implemented in TIMES (The Integrated MARKAL-EFOM System).
The aims of this paper are to identify optimal alternatives for the integration of increased shares of local renewable electricity generation with a mix of heating technologies in the heating sector not connected to DH and to study the resulting interaction between electricity and heating sectors. The research investigates the multiple requirements of a Nordic municipality for a sustainable energy supply, which include the reduction of CO2 emissions, the increase of energy self-sufficiency through investments in local renewable electricity generation, the reduction of peak electricity demand caused by electric heating and, of course, the minimization of total annual energy system costs. The study further evaluates the effect of uncertain exogenous variables, such as electricity price, discount rates, and biomass price by performing a sensitivity analysis on these parameters.
This research interfaces EnergyPLAN with a multi-objective evolutionary algorithm (MOEA) implemented in Matlab [46], which has been successfully applied in a number of real-engineering problems, most recently on the optimization of a DH network expansion [47]. The energy system of Piteå municipality (Norrbotten, Sweden) is used as a representative case study for municipalities located in the northernmost regions of the Nordic countries.
The paper is structured as follows. Section 2 describes the methodology applied, the simulation and optimization tools and the key parameters of the municipal energy system model. Section 3 outlines the case study of Piteå, and Section 4 presents and discusses the main features of the optimal alternatives for the integrated electricity and heating sectors. Finally, Section 5 provides conclusive remarks and suggestions for further research.

2. Methodology

The deterministic simulation tool EnergyPLAN is used in this paper to model the electricity and heating sectors of the energy system of a Nordic municipality. EnergyPLAN executes a techno-economic analysis simulating the interactions between the modeled sectors on an hourly basis for a period of one year in very short processing times [37,48]. For a detailed description of EnergyPLAN, the reader is referred to the documentation available at [34].
This section defines the multi-objective optimization problem (MOOP) and describes the applied MOEA and the interface that has been implemented to exchange information with EnergyPLAN. Moreover, the values for key parameters of the energy model are discussed, such as electricity price, biomass price, discount rate, technology costs, and grid emission factors.

2.1. The Multi-Objective Optimization Problem for a Generic Municipal Energy System

2.1.1. Objective Functions

The objective functions to be minimized are the total annual system costs Ctot and the system CO2 emissions Emsys of the electricity and heating sectors of a municipal energy system.
The total annual system costs Ctot calculated by EnergyPLAN are the sum of:
  • The annualized capital cost Cann of each component in the modelled energy system, which considers capital cost, expected lifetime, discount rate dr and fixed operation and maintenance (O&M) costs.
  • Variable O&M costs.
  • Fuel costs, which depend on biomass price pbio.
  • Costs/revenues from the import/export of electricity from/to the grid, both calculated with the spot price pel.
  • System CO2 emissions Emsys calculated by EnergyPLAN are the sum of:
  • CO2 emissions due to the electricity imported from the national grid, Emimp, considering a grid emission factor EFgrid.
  • CO2 emissions due to fossil fuel use within the boundaries of the municipal energy system.

2.1.2. Decision Variables

The decision variables of the MOOP deal with the way in which the demands of the electricity and heating sectors of the municipal energy system are covered.
The decision variables in the electricity sector are the installed capacities (in MW) for electricity generation technologies, such as hydropower, biomass-fired power, solar power, wind power. Lower bounds for the considered ranges of these variables can be set to zero or to existing installed capacities, whereas upper bounds can be set to limits depending, e.g., on the available areas found in municipal master plans for local renewable electricity generation technologies. Within the considered ranges, the values of the installed capacities are discretized according to the typical capacity of single electricity generation devices, e.g., a single wind turbine.
The decision variables in the heating sector are the amounts of heat (in GWh) supplied during a year by heating technologies both in district and individual heating systems, such as fossil fuel boilers, biomass boilers, electric boilers, heat pumps. The lower bound for the ranges of these variables is zero, and the upper bound is the annual heating demand that has to be covered by these technologies.

2.1.3. Constraints

Satisfying electricity and heating demand at any given time are the typical constraints in energy system modelling. EnergyPLAN calculates electric energy balances as a result of given demands, component behaviors, and selected regulation strategies. It imports or exports electricity from the grid utilizing the defined transmission line and provides warnings when certain limits are exceeded. Peak electricity import Pel,maximp is an important output of the calculations, because Nordic countries have a high share of electric heating that results in extreme peak demand during the heating period. Pel,maximp is most relevant for municipalities in which transmission line capacities can become a bottleneck. The same bottleneck could limit the installation of new local electricity generation capacity, or could lead to curtailing, because of the increase of electricity export to the national grid. Peak electricity export Pel,maxexp is therefore another output to be monitored.
Heating demand is balanced at any time, as the sum of the values of the decision variables related to the heating supply must be equal to the annual heating demand.

2.2. The Optimization Algorithm and the Interface with EnergyPLAN

The multi-objective evolutionary optimization algorithm (MOEA) described in [46] was adapted to search for the optimal trade-offs of the defined MOOP. The main feature of this MOEA is a diversity-preserving mechanism that treats diversity as a meta-objective in the evaluation phase. In order to reduce the computational effort, a consolidation ratio [49] is adopted as the criterion to terminate the search process. The numerical results, including those that this paper presents, prove that the solutions effectively converge toward the Pareto optimal front and that they are well distributed.
Figure 1 gives an overview about the interface between the MOEA and EnergyPLAN modelling and simulation procedure and about the wrapper software that has been developed for the exchange of information.

2.3. Model Parameters and Uncertainties

Energy system analysis has to deal with multiple uncertainties related to technical, environmental, and economic parameters. In this study, sources of uncertainty for local renewable energy production include site-specific climate data and the capacity factors of the different technologies. Different CO2 emission accounting methods can lead to significant differences in emission factors. The estimation of costs is directly affected by the economic parameters, such as technology costs, electricity and fuel prices, and discount rates.

2.3.1. Electricity Price pel

Calculated costs for imported electricity and revenues for exported electricity are included in the economic objective function of the MOOP. These are based on the hourly electricity spot price pel for the Nordic electricity system as available from the NordPool power market [22]. The selection of pel value is based on the historical price trend of Nordic power market, where the average annual electricity spot price moves between a long term low of 21 EUR/MWh in 2015 and 50 EUR/MWh by the end of 2018. The considered values for the annual average pel in the sensitivity analysis are then 20, 40, and 60 EUR/MWh.

2.3.2. Biomass Price pbio

The price of biomass (pellets) pbio affects the costs associated with the heating sector that is not supplied by DH. Swedish pellet prices from 2010 to 2018 show a range of the annual average pbio between 34.39 EUR/MWh in 2017 and 38.03 EUR/MWh in 2011 [50] (including delivery for household supply). In EnergyPLAN cost database for 2020 pbio for household supply consists of two parts: biomass price and delivery costs. Delivery costs are kept constant in the sensitivity analysis, and the considered values for pbio are 26.25, 35.0, and 43.75 EUR/MWh. This price setting reflects a development of the future pbio within ±25% from the 2018 annual average of 35.0 EUR/MWh.

2.3.3. Discount Rate dr

Discounting in energy system analysis considers two perspectives: social dr, for evaluating costs and benefits from a societal perspective, and individual dr, for evaluating investment decisions [51]. Applied social dr in energy studies ranges between 1% and 7% and the dr for industrial investors ranges from 6% to 15% [51,52]. In the sensitivity analysis of this study the considered values for dr are 3%, 9%, and 15%.

2.3.4. Technology Costs

Technology cost parameters are available from the EnergyPLAN package [34]. References of EnergyPLAN cost database include the catalogues of energy technology data published by the Danish Energy Agency and Energinet, JRC Technical Reports and the ETRI projections for 2010–2050 [53,54,55]. It is assumed in this study that technology costs are sufficiently reliable, especially with the consideration that all the technologies associated with the decision variables are mature.

2.3.5. Weather Conditions

Annual heating demand and annual electricity generation from windpower, hydropower, and solar PV can vary significantly in different years because of the weather conditions. In this work the weather data set used refers to a specific period of only one year (2015), although the study of selected years with extreme weather data would address uncertainties arising from unpredictable weather conditions.

2.3.6. Grid Emission Factor EFgrid

The European Joint Research Center (JRC) published National and European Emission Factors for Electricity consumption (NEEFE) [56,57]. JRC recommends that NEEFE are applied in the emission inventories of the municipalities that signed the EU Covenant of Mayors for Climate and Energy (CoM), a network of local governments committed to implementing EU climate and energy objectives. Most Swedish signatory municipalities historically created their emission inventories applying the EFgrid of the Nordic electricity mix, which considers import dependencies of the Nordic electricity market 2015 [58]. Currently no Swedish institution regularly updates EFgrid values for the Nordic electricity mix. Table 1 presents the different EFgrid values for Sweden in 2015.
Different CO2 emission accounting methods lead to significant differences in EFgrid values. The energy system model in this paper neglects the CO2 emissions from local renewable energy production, as for CoM signatory municipalities all local renewable energy generation can be considered as CO2 free [56], so that CO2 emissions are merely a consequence of imported electricity Emimp according to the selected value of EFgrid.

3. The Piteå Case Study in EnergyPLAN

A case study for the Piteå municipal energy system was implemented by the authors in EnergyPLAN as part of the Arctic Energy project between 2016 and 2018 [5]. Piteå municipality, located in Norrbotten county of Sweden, participated in the project and can be considered as a representative municipality in the Nordic context. Piteå became a signatory to the CoM in 2009, submitted the Sustainable Energy Action Plan (SEAP) to CoM in 2010 [59], and has renewed its commitment to CoM in 2017 [60]. In the 2010 SEAP Piteå sets the following targets for the municipality and its energy sector to be achieved by 2020:
  • Reduce GHG emissions of the entire municipality by 50% (base year 1998).
  • Convert all fossil fuel fired boilers for heating and industrial processes.
  • Reduce net energy demand by 20% for apartment and commercial buildings and 10% for single-family homes (base year 2008).
  • Supply electricity and heating demand with 100% renewable sources.
  • Become a net exporter of renewable electricity.
The SEAP also details a number of measures to be implemented and a progress report presents achieved results by 2013 [61].
Piteå had 41,548 inhabitants by 2015. 145 MW of wind power, 40.9 MW of hydropower, 256 kWp of PV were installed within the municipal boundaries. Industrial biomass fueled combined heat and power (CHP) plants, with an aggregated power production capacity of 78 MW, supplied about 53% of the own electricity demand of these industries. The total final electricity consumption of Piteå municipality was 1453 GWh in 2015, of which 1117 GWh were supplied from local generation and the reminder was imported from the national grid. DH supplied 269 GWh of heat in urban areas, mainly utilizing industrial excess heat. Heat consumption in buildings not connected to DH was 238 GWh, of which 166 GWh were provided by electric heating, including heat pumps, and 70 GWh from biomass boilers. More key figures about Piteå are presented in Table 2 with references to the sources.

3.1. Case Study Decision Variables

The choice of the decision variables in this case study is strictly related to the peculiar features of the municipal energy system in Piteå.
In the electricity sector, the decision variables are the installed capacities (in MW) for three local renewable electricity generation technologies: utility scale solar PV systems (PV), onshore wind turbines (WindON), and offshore wind turbines (WindOFF). A possible expansion of hydropower capacity is not considered because of environmental legislation [70]. Biomass-fired CHP plants are not considered because the heating demand satisfied with DH is already covered with waste heat from industries, and the DH network already connects the most densely populated areas in the municipality. In this study the capacity of the transmission line is set to unlimited and resulting values for electricity import and export are discussed.
In the heating sector, it is assumed that DH will continue to operate as it presently does. Accordingly, the decision variables are related to individual heating systems, and they are the amounts of heat (in GWh) supplied during a year by biomass boilers (BioB), heat pumps (HP) and electric heating (ElB).
Table 3 shows the levelized costs of electricity LCOE in EUR/MWh and the annualized capital cost Cann in EUR/MW for the considered renewable electricity generation technologies, and Cann in EUR/unit for the considered heating technologies. The EnergyPLAN cost database provided technology cost parameters to calculate these values, which will be important for later discussions. A 50/50% mix of air–air heat pumps and ground source heat pump types is considered for HP according to sale statistics [71]. LCOE takes into account the technology costs for 2020 and considers average capacity factors for the Nordic location. It is important to note that Cann for renewable electricity generation is lowest for PV and highest for WindOFF, while LCOE is lowest for WindON and highest for PV due to the different capacity factors.

3.2. Selected Scenarios Simulated with EnergyPLAN

The model of the Piteå municipal energy system was built in EnergyPLAN and a number of scenarios were simulated for reference before coupling the model to the optimization algorithm (Figure 2) [5].
The “Base2015” scenario was simulated to analyze the situation in the year 2015. With technology costs for 2015, an average pel for the Nordic electricity system of 40 EUR/MWh and a dr of 9%, Ctot resulted equal to 81.9 MEUR (Figure 2). The calculated value for Emsys was 37.4 ktCO2, neglecting the CO2 emission from local renewable energy generation as recommended by JRC to CoM signatory municipalities to consider as CO2 emissions free [56]. This is a consequence of a 374 GWh grid electricity import with a grid emission factor for the Nordic electricity mix of 0.1 tCO2eq/MWh, the same applied in the emission inventory for Piteå as presented in the Piteå SEAP [59].
Technology costs for 2020 (see Section 2 and Table 3) and an average pel for the Nordic electricity system of 40 EUR/MWh were used as standard parameters in all scenarios related to year 2020. The “Demand2020” scenario simulated a variation of the demand in electricity and heating sectors with respect to the 2015 situation, because of the achievement of the following 2020 targets mentioned in Piteå SEAP: the conversion of fossil fuel heating into renewable heating, considering a mix of biomass and heat pump solutions, and the implementation of energy efficiency measures in the building sector. This resulted in a reduction of electricity import (358 MWh) and Emsys (35.8 tCO2eq/MWh, 5.8% less than Base2015). The calculated Ctot (with dr = 9%) was 78.1 MEUR, 4.6% less than in Base2015, but if 2020 technologies costs were applied to the 2015 situation (Base2015-costs2020 scenario) then the reduction in Ctot would be 2.4% only (Figure 2).
The “Balanced2020” scenarios were inspired by the net-export 2020 target in Piteå SEAP, because they simulate the condition in which there is a near-zero balance between electricity import and export considering a one year period. In each Balanced2020 scenario this condition was achieved by investing in additional capacities of a different mix of renewable electricity generation technologies (PV, WindON and WindOFF) starting from the Demand2020 situation. EnergyPLAN is able to deliver fast results for integrated energy system studies and the user can analyze different options in order to approach defined conditions for the modelled energy system. The options for the mix of technologies are chosen by the user on the basis of available domain knowledge. A condition such as a near-zero balance is relatively easy to achieve when only few technologies are included in the set of options, thanks to the EnergyPLAN feature that allows the user to perform a series of simulations in one run with up to 11 different values for a parameter (in this case the capacity of one renewable electricity generation technology).
Comparing the simulated Balanced2020 scenarios with Demand2020 (Figure 2), Ctot (dr = 9%) increase between 2.2% and 12.9%, while CO2 emissions are reduced to a minimum of 20.6 ktCO2 (−42.5%) in the Balanced2020-WindON-OFF-PV scenario (with 145 MW WindON, 100 MW PV and 60 MW WindOFF additional capacities). Base2015 Pel,maximp (168.3 MW) is reduced in the Demand 2020 scenario to 164.7 MW (−2.1%), and further reduced to a minimum of 157.8 MW in the Balanced2020-WindON-OFF scenario.
Balanced2020 scenarios provide possible alternatives to achieve the near-zero balance condition as created by an EnergyPLAN user, without an indication whether the corresponding CO2 emission reductions are obtained with a minimum cost increase. On the contrary, the multi-objective optimization approach shall provide better knowledge of the alternatives that represent the optimal trade-offs between the two conflicting objectives of the MOOP.

3.3. Setup of Parameters for the MOOP

The starting point of the optimization runs is the energy system model of Piteå municipality with the parameters of Demand2020 scenario. It is worth noting that in this scenario the only CO2 emissions are those due to electricity import, since no fossil fuel is used either in the electricity or heating sector, and, therefore, Emsys is equal to Emimp.
Table 4 lists the chosen ranges and the discretization steps for the decision variables of the MOOP defined in this study. Maximum PV capacity (100 MW) was determined by limiting land use to about 0.1% of the available land area of Piteå municipality. The discretization step of 1 MW reflects the utility scale for ground-mounted solar PV systems. The discretization steps for WindON and WindOFF were set according to the capacity of single wind turbines typically installed in such wind developments in recent years. Minimum WindON capacity of 145 MW was the existing installed capacity in 2015, whereas the maximum was set to 505 MW in order to allow for the installation of one hundred additional wind turbines of 3.6 MW each [72]. Maximum WindOFF capacity was set to 330 MW considering the available area declared in the wind development plan of Piteå and in published project plans for this area [72,73]. Higher technical potentials exist anyway for all technologies. The decision variables for the heating sector (ElB, BioB, and HP) are continuous and the sum of the amounts of heat supplied by the three technologies has to satisfy the annual heating demand of the individual heating sector (i.e., the demand from buildings not connected to DH, 211.7 GWh according to the Demand2020 scenario).

4. Results and Discussion

Two different sets of optimization runs were performed considering the decision variables of (a) electricity sector only and (b) integrated electricity and heating sectors. Within each set, the optimization runs are repeated with different values of the economic parameters discussed in Section 2 to implement sensitivity analysis. Initial test runs confirmed sufficient diversity and convergence toward the Pareto front, considering that the termination criterion on the consolidation ratio is satisfied, as described in Section 2. The electricity sector only runs were then configured with 100 individuals and 300 generations, whereas integrated electricity and heating sectors runs were configured with 200 individuals and 500 generations.
The figures in the following subsections present the Pareto fronts plotting Ctot vs. CO2 emission reduction with respect to Demand2020 scenario, and the Pareto sets of optimal solutions plotting the optimal values of the decision variables vs. CO2 emissions reduction with respect to Demand2020 scenario. The effects of the optimal solutions on Pel,maximp are also discussed.

4.1. Electricity Sector Only

Figure 3 presents the optimal results obtained about the case study considering the capacities of the three renewable electricity generation technologies (PV, WindON, and WindOFF) as the decision variables of the MOOP. These technologies differ widely in Cann, which is affected by dr and LCOE (in the latter the capacity factor is also an important parameter, see Table 3). The different values of the economic parameters considered in the sensitivity analysis have a significant impact on the cost objective function of the MOOP. In fact, these parameters will affect the relative weights in Ctot of investment costs and operational costs/revenues due to electricity import/export: for a constant pel, a higher dr will increase Cann and in turn Ctot, whereas a higher pel will dampen the growth of Ctot as electricity export will generate larger revenues when installed generation capacities increase. This plays a fundamental role in determining which combinations of technologies are the optimal trade-offs among the conflicting objectives of the MOOP.
WindOFF has the highest Cann of the three technologies and a LCOE between WindON and PV because of the highest capacity factor (40%); on the other hand WindON, in spite of having a higher Cann than PV, has a lower LCOE thanks to the higher capacity factor (30% vs. 12%, see Table 3). In the 3 × 3 diagrams in Figure 3 Ctot is dominated by the investment costs when a) pel = 20 EUR/MWh, which is below all LCOEs with all dr; b) pel = 40 EUR/MWh with dr = 9% and 15%; c) pel = 60 EUR/MWh with dr = 15%. In these cases, WindOFF contributes to the optimal solutions only when both WindON and PV have already reached their considered maximum installed capacities, meaning that further CO2 emission reductions from that condition are only possible with investments in WindOFF, which are the least convenient for those values of the economic parameters.
As operational costs/profits start to counterbalance investment costs, the slope with which Ctot increases as CO2 emissions are reduced decreases, up to the point in which the Pareto front does not contain solutions with small CO2 emission reduction. With pel = 40 EUR/MWh and dr = 3% all solutions feature WindON at the maximum capacity, starting from emission reductions of 58% at minimum Ctot with zero capacity of WindOFF and PV. This means that is no longer economically convenient to look for solutions that achieve CO2 emissions reductions below 58% because of the large profits that can be achieved by exporting the electricity generated with WindON, which has to be exploited at the maximum considered capacity. From this condition, WindOFF provides better trade-offs than PV and increases its capacity up to the maximum, resulting in emission reductions of about 80%. Only when all available wind capacities are fully utilized PV becomes part of the solution set, further reducing emissions by 85%.
With more significant operational profits due to pel = 60 EUR/MWh (at dr = 9%), emission reduction at minimum Ctot is even slightly higher than 60% and, again, all optimal solutions feature WindON at its maximum capacity. As the optimal Ctot increases from its minimum value both PV and WindOFF are convenient enough from the economic point of view to be featured in the solution set.
Finally, when the revenues from exported electricity totally prevail over investment costs (pel = 60 EUR/MWh and dr = 3%), all LCOEs fall below pel and the two objectives of the MOOP are no longer conflicting. In this case only one optimal solution exists, featuring maximum installed capacities for all three technologies. Please note that, as expected, all the Pareto optimal set of solutions obtained for different values of pel and dr end up in this same solution (which also corresponds to maximum CO2 emission reduction, 85%), since this is due to the upper limit chosen for the ranges for the decision variables.
It is important to observe that, in spite of its low capacity factor (12%) due to the Nordic location, PV is shown to be more economically convenient than WindOFF in six out of the nine considered combinations of the economic parameters.
Figure 4 shows the reductions achieved in peak electricity import Pel,maximp with the optimal solutions obtained considering the three renewable electricity generation technologies (all diagrams correspond to those in the same position in Figure 3). In Piteå municipality Pel,maximp can be reduced from 165 MW (Demand2020 scenario) to 129 MW (−21.8% or 36 MW) by installing maximum capacities for all the three technologies. A Svenska Kraftnät report on wind power integration estimates the minimum availability factor of wind power across Sweden at 6% [74]. If this 6% were applied to the additional 690 MW capacity of WindON and WindOFF installed in the Demand2020 scenario, the wind turbines would provide 41.4 MW as a minimum, confirming the reliability of the simulation results from EnergyPLAN.

4.2. Integrated Electricity and Heating Sectors

This subsection presents the results of the optimization runs in which all the six decision variables of the MOOP are considered (PV, WindON, WindOFF, ElB, HP, BioB). This means that the electricity and heating sectors are considered integrated and optimized together, enabling the analysis of potential interactions between these sectors. Figure 5 duplicates the number of diagrams in the 3 × 3 grid already used in Figure 3, since the optimal values of decision variables related to the electricity sector are shown separated from those related to the heating sector for sake of clarity. In Figure 5a low pel (20 EUR/MWh) is paired with high pbio (43.75 EUR/MWh), in Figure 5b the central values of pel and pbio are paired (40 EUR/MWh and 35 EUR/MWh, respectively), and in Figure 5c high pel (60 EUR/MWh) is paired with low pbio (26.25 EUR/MWh). These combinations of pel and pbio values are paired in turn with all the considered values for dr.
From the diagrams in Figure 5 it is apparent that the optimal decision variable values for the renewable electricity generation technologies follow in general the same trends as in Figure 3, but with some significant differences related to the interaction with the heating sector. Looking at the optimal decision variable values associated with heating technologies, the diagrams show that ElB disappears from the optimal solutions already in the early stages of CO2 reduction. No significant increase of renewable electricity generation capacities above their lower bounds is registered within this range of emission reductions, after which a 100% heating supply with HP represents the best trade-off for the heating sector. Only then the optimal solutions start to feature increasing renewable electricity generation capacities, widely following the same patterns as in the electricity only cases, until the point in which BioB in the heating sector becomes economically more convenient to further reduce emissions.
A higher share of BioB determines a drop of the electricity demand in the overall municipal energy system, which reduces electricity import and, in turn, mitigates related emissions Emimp. Thus, the transition from HP to BioB causes a significant interaction with the decision variables related to the electricity sector. The substitution of HP with BioB is so beneficial, both in terms of costs and in reducing electricity demand, that the capacities of the renewable electricity generation technologies decrease during the transition while CO2 emissions are reduced.
This transition from HP to BioB occurs at different levels of CO2 emissions reductions depending on the values of the economic parameters. For the same values of pel and pbio, the transition is shifted toward lower emissions by a lower dr as the difference in investment costs between the two technologies becomes less significant. On the other hand, for the same values of dr, the transition is shifted toward lower emissions by a higher pel and/or a lower pbio (biomass fuel costs are another term, relatively less significant, in Ctot). Finally, the transition is more gradual for a higher dr.
Comparing the results of the integrated electricity and heating sectors (Figure 5) with those of the electricity sector only (Figure 3), it can be observed that the same emission reductions can be achieved with lower installed capacities of the renewable electricity generation technologies. In fact, the transition in the heating sector from the current technology mix to HP and, for higher emission reductions, to BioB reduces electricity demand and results in lower emissions because of less import from the grid.
The trend of Pel,maximp vs. CO2 emission reductions is shown in Figure 6. It can be interpreted as the composition of two effects: (i) as in the electricity only case Pel,maximp decreases because of the growth of the installed capacities of PV, WindON and WindOFF; (ii) during the transitions from one heating technology to another Pel,maximp follows the trend of the overall electricity demand, i.e., it is reduced when HP replaces ElB and then when BioB replaces HP. Minimum Pel,maximp is 103 MW, with a 38% reduction from the 165 MW in Demand2020 scenario, and it is of course achieved with 100% BioB supply of the individual heating sector and with maximum installed capacities of PV, WindON, and WindOFF.
As a final note, the comparison in Figure 7 between the optimal Ctot obtained with and without the individual heating sector shows that Ctot is always lower, for the same level of CO2 emissions, when heating technologies are included in the set of decision variables. At 80% emission reductions, the costs are 1%, 7%, and 16% lower for dr = 3%, 9%, and 15% respectively. This underlines the importance of integrating and optimizing the electricity and heating sectors together, as these results are not trivial.

4.3. Duration Curves for Electricity Import/Export

The load on the supplying transmission line(s) is an important aspect to monitor in a municipal energy system. In this case study the connection with the national grid is modelled as a single transmission line with unlimited capacity. Figure 8 plots the duration curves of electricity import/export for the municipal energy system of Piteå according to the EnergyPLAN scenarios Demand2020 and Balanced2020 and the optimized solutions at 60% and 80% emission reduction for the middle range values of pel = 40 EUR/MWh, pbio = 35 EUR/MWh, and dr = 9%. The leftmost point of the duration curve for the power import/export is Pel,maximp and rightmost one is Pel,maxexp with a negative sign. Figure 9 presents the corresponding installed capacities of PV, WindON, and WindOFF.
The EnergyPLAN Demand2020 scenario was the starting point for the optimization cases (see Section 3), featuring installed WindON capacity is 145 MW. Pel,maximp is 165 MW and electricity import exceeds 100 MW for about 400 h, while Pel,maxexp is 86 MW.
The EnergyPLAN Balanced2020 scenario achieves 42.5% emission reductions compared to Demand2020 by installing a total local electricity generation capacity of 305 MW, resulting, as intended, in an annually balanced import/export of electric energy. Pel,maximp is 160 MW and necessary import exceeds 100 MW for about 200 h. Pel,maxexp is 204 MW and export exceeds 100 MW for about 400 h.
The optimized solutions for the electricity sector only feature a total installed capacity of 523 MW for 60% emission reductions and 776 MW for 80% (the heating sector remains as in Demand2020 and Balanced2020). Pel,maximp is 151 MW (138 MW) for the 60% (80%) emission reduction case, with electricity import exceeding 100 MW for about 100 h (45 h). Pel,maxexp is 437 MW (684 MW), with electricity export exceeding 100 MW for about 3300 h (4700 h), and 400 MW for 20 h (1200 h).
Optimizing the integrated electricity and heating sector results in total installed capacities of 479 MW for 60% emission reductions and in 637 MW for 80% (individual heating demand is completely supplied by heat pumps in the former case and by biomass boilers in the latter). Pel,maximp is 151 MW (149 MW) for the 60% (80%) emission reduction case, with electricity import exceeding 100 MW for about 100 h (70 h). Pel,maxexp is 413 MW (514 MW), with electricity export exceeding 100 MW for about 3100 h (3700 h), 400 MW for 4 h (170 h).
The decrease of Pel,maximp is relatively small in the optimized cases, between 8.5% and 16.4% compared to the Demand2020 scenario. This is due to low wind speed during some cold winter days with high electricity demand, so that large installed capacities only have a minor impact on the import peak while having a major one on the export peak. Accordingly, only storage solutions can significantly lower Pel,maximp without causing a disproportional increase of Pel,maxexp. In fact, a significant increase of Pel,maxexp can be observed for all cases, from 135% to 500% compared to Demand2020 scenario the higher are the installed capacities. The real capacity of transmission lines eventually pose a limitation to the expansion of such large-scale local electricity generation, which is technically possible in many of the Nordic municipalities as the technical wind potential is vast as is the available land area.
The differences in Pel,maximp between the cases in which the individual heating sector is supplied by heat pumps (60% emission reduction) or by biomass boilers (80% emission reduction) are limited as the two different electricity demands are paired with different amounts of installed capacities. It is worth noting, however, that the duration of high electricity import is significantly shortened compared to Demand2020 scenario, and that the integration between electricity and heating sector has a more limited effect on the growth of Pel,maximp.

4.4. Near-Zero Electricity Import/Export Balance Condition and CO2 Emissions

Some solutions within the set of the optimal trade-offs are close to the near-zero electricity import/export balance condition, as discussed in the scenarios simulated with EnergyPLAN for Piteå (Section 3). Table 5 offers a comparison between the EnergyPLAN simulation results for Demand2020 and Balanced2020 scenarios and the optimal solutions closest to the near-zero balance condition from the results presented in Section 3 (with pel = 40 EUR/MWh, pbio = 35 EUR/MWh and dr = 9%). The renewable electricity generation technology used in these optimal solutions is WindON exclusively, with at most a small PV capacity. The optimal results obtained for integrated electricity and heating sectors at this near-zero balance condition provide a solution with the individual heating sector totally supplied by heat pumps. The comparison shows that optimal Ctot values are 7.8% (electricity only) and 9.8% (integrated electricity and heating) lower than Balanced2020 scenario Ctot. Both optimized solutions provide emission reductions of about 36% with a cost increase of 4.6% (electricity only) or 2.5% (integrated electricity and heating) compared to Demand2020 scenario. The optimal solutions also result in lower Pel,maximp compared to Demand2020 and Balanced2020 scenarios.

5. Conclusions

This paper exploited the benefits of combining EnergyPLAN, an energy system analysis and simulation tool, with a multi-objective evolutionary algorithm to investigate the optimal alternatives for the development of the integrated electricity and heating sectors of a municipal energy system in the Nordic context. Total annual costs and CO2 emissions were defined as objective functions to be minimized, sensitivity analyses on key economic parameters were performed and the impact on electricity import/export was also analyzed.
The results for the case study about Piteå (Norrbotten, Sweden), chosen as a representative municipality in the Nordic context, showed that CO2 emission reductions of at least 60% can be achieved without a considerable increase of total annual costs. Cost increases are always lower when electricity and heating sectors are integrated, since lower installed renewable electricity capacities are required to achieve given emission reductions. CO2 emission reductions higher than 60% can be achieved either by increased local renewable electricity generation or by replacing HP with BioB. After the introduction of biomass boilers, only larger renewable electricity generation capacities (usually WindOFF at this point, since WindON and solar PV, in spite of the low 12% capacity factor in the Nordic region, may have already reached their maximum installed capacities depending on the economic conditions) can further reduce emissions, with steeper cost increases. At 60% emission reductions, peak electricity import reduces by a maximum of 8%, while peak electricity export increases by about 400%, posing a challenge on the available transmission lines. At highest emission reductions peak electricity import Pel,maximp can be reduced by up to 38%.
The results obtained for Piteå municipality are of course case dependent. However, the conclusions can be extended to the entire Nordic region as the majority of the population is concentrated in municipalities similar to Piteå. By utilizing available potentials for WindON and solar PV, as well as by implementing a heat pump strategy for the heating demand not served by district heating, significant reductions of carbon emissions can be achieved without noteworthy increases of total annual energy system costs. For coastal areas, in economic conditions with high electricity prices and low discount rates, offshore wind capacities can feasibly contribute to emission reductions. A biomass heating strategy is indicated if reductions of peak electricity import are targeted, although the increase of peak electricity export related to the large expansion of local electricity generation also suggests the use of storage solutions.
The methodology of interfacing EnergyPLAN with a MOEA, together with an extensive sensitivity analysis on uncertain economic parameters, creates a wide set of optimal combinations of renewable electricity generation and heating options minimizing total annual costs and CO2 emission reductions. With this set of combinations, local decision-makers can now be made aware about the whole spectrum of optimal trade-off solutions and take more informed decisions for promoting a pathway toward a sustainable energy system for their municipality.
Future studies shall investigate the integration of electricity and heating sectors with different electricity storage options, including stationary and mobile storage, with peak electricity import/export and total annual system costs to be minimized. In the model of the heating sector, it would be important to consider district heating technology options such as large-scale heat pumps, solar thermal energy and thermal storage. Finally, analyzing impacts of policy developments, including CO2 targets, CO2 prices, and subsidies for technologies, and evaluating the potentials for local value and job creation are other areas for possible future work.

Author Contributions

R.F.: conceptualization; data curation; formal analysis; investigation; methodology; software; roles/writing—original draft. E.E.: supervision; validation; writing—review and editing. A.T.: formal analysis; methodology; software; supervision; validation; writing—review and editing. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the Interreg Nord funded project Arctic Energy-Low Carbon Self-Sufficient Community (ID: 20200589).

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

BioBBiomass boiler heating
CannAnnualized capital cost
CtotTotal annual system cost
CHPCombined Heat and Power
CoMEU Covenant of Mayors for Climate & Energy
DHDistrict heating
drDiscount rate
EFgridGrid emission factor
ElBElectric boiler heating and direct electric heating
EmimpCO2 emissions of the electricity imported into the geographical scope of the model
EmsysCO2 emissions of the modelled integrated energy system (electricity and heating)
EUEuropean Union
GHGGreenhouse gas
HPHeat-pump
IPCCIntergovernmental Panel on Climate Change
JRCEuropean Joint Research Center
LCALife Cycle Assessment
LCOELevelized cost of electricity
MEURMillions of euros (equivalent to M€)
MOEAMulti-objective evolutionary algorithm
MOOPMulti-objective optimization problem
NEEFENational and European Emission Factors for Electricity consumption
O&MOperation and maintenance
pbioBiomass price
pelElectricity price
Pel,maxexpAnnual peak (maximum) electricity export from the geographical scope of the model
Pel,maximpAnnual peak (maximum) electricity import from the geographical scope of the model
PVPhotovoltaic; also in this paper: utility scale solar photovoltaic systems
SEAPSustainable Energy Action Plan
TIMESThe Integrated MARKAL-EFOM System
UNFCCCUnited Nations Framework Convention on Climate Change
WindONOnshore windpower
WindOFFOffshore windpower

References

  1. European Council. 2030 Climate and Energy Policy Framework; European Council: Brussels, Belgium, 2014. [Google Scholar]
  2. European Parliament. REGULATION (EU) 2018/842 on Binding Greenhouse Gas Emission Reductions by Member States from 2021 to 2030; European Parliament: Brussels, Belgium, 2018. [Google Scholar]
  3. IEA. Global Energy and CO2 Status Report 2018; International Energy Agency: Paris, France, 2019. [Google Scholar]
  4. EPA. Sweden Sveriges Officiella Statistik—Nationella Utsläpp och Upptag av Växthusgaser. Available online: https://www.naturvardsverket.se/Sa-mar-miljon/Statistik-A-O/Vaxthusgaser-territoriella-utslapp-och-upptag/ (accessed on 10 May 2019).
  5. Micropolis Arctic Energy—Energiaomavarainen Pohjoinen—Greenpolis. Available online: https://www.greenpolis.fi/en/projektit/arctic-energy/ (accessed on 16 May 2019).
  6. Hirvonen, J.; ur Rehman, H.; Sirén, K. Techno-economic optimization and analysis of a high latitude solar district heating system with seasonal storage, considering different community sizes. Sol. Energy 2018, 162, 472–488. [Google Scholar] [CrossRef] [Green Version]
  7. Lund, H.; Werner, S.; Wiltshire, R.; Svendsen, S.; Thorsen, J.E.; Hvelplund, F.; Mathiesen, B.V. 4th Generation District Heating (4GDH). Integrating smart thermal grids into future sustainable energy systems. Energy 2014, 68, 1–11. [Google Scholar] [CrossRef]
  8. Paiho, S.; Reda, F. Towards next generation district heating in Finland. Renew. Sustain. Energy Rev. 2016, 65, 915–924. [Google Scholar] [CrossRef]
  9. Werner, S. International review of district heating and cooling. Energy 2017, 137, 617–631. [Google Scholar] [CrossRef]
  10. Averfalk, H.; Ingvarsson, P.; Persson, U.; Gong, M.; Werner, S. Large heat pumps in Swedish district heating systems. Renew. Sustain. Energy Rev. 2017, 79, 1275–1284. [Google Scholar] [CrossRef]
  11. Hast, A.; Rinne, S.; Syri, S.; Kiviluoma, J. The role of heat storages in facilitating the adaptation of district heating systems to large amount of variable renewable electricity. Energy 2017, 137, 775–788. [Google Scholar] [CrossRef]
  12. Levihn, F. CHP and heat pumps to balance renewable power production: Lessons from the district heating network in Stockholm. Energy 2017, 137, 670–678. [Google Scholar] [CrossRef]
  13. Schweiger, G.; Rantzer, J.; Ericsson, K.; Lauenburg, P. The potential of power-to-heat in Swedish district heating systems. Energy 2017, 137, 661–669. [Google Scholar] [CrossRef]
  14. Jordehi, A.R. Optimisation of demand response in electric power systems, a review. Renew. Sustain. Energy Rev. 2019, 103, 308–319. [Google Scholar] [CrossRef]
  15. Avelin, A.; Dahlquist, E.; Wallin, F. Effect of different renovation actions, their investment cost and future potential. Energy Procedia 2017, 143, 73–79. [Google Scholar] [CrossRef]
  16. Broberg, T.; Persson, L. Is our everyday comfort for sale? Preferences for demand management on the electricity market. Energy Econ. 2016, 54, 24–32. [Google Scholar] [CrossRef] [Green Version]
  17. Hellmer, S. Switching Costs, Switching Benefits and Lock-In Effects—The Reregulated Swedish Heat Market. Energy Environ. 2010, 21, 563–575. [Google Scholar] [CrossRef]
  18. Wöhler, M.; Andersen, J.S.; Becker, G.; Persson, H.; Reichert, G.; Schön, C.; Schmidl, C.; Jaeger, D.; Pelz, S.K. Investigation of real life operation of biomass room heating appliances—Results of a European survey. Appl. Energy 2016, 169, 240–249. [Google Scholar] [CrossRef]
  19. NO OED. Energy Use by Sector. Available online: https://energifaktanorge.no/en/norsk-energibruk/energibruken-i-ulike-sektorer/ (accessed on 10 May 2019).
  20. Finnish Energy Finnish Energy—District Heating and Cooling. Available online: https://energia.fi/en/news_and_publications/statistics/district_heating_statistics/district_heating_and_cooling (accessed on 10 May 2019).
  21. Swedish Energy Agency. Energiläget i Siffror 2019. Available online: http://www.energimyndigheten.se/nyhetsarkiv/2019/Nu-finns-siffror-pa-energilaget-i-Sverige/ (accessed on 10 May 2019).
  22. NORDPOOL. Historical Market Data. Available online: https://www.nordpoolgroup.com/historical-market-data/ (accessed on 13 May 2019).
  23. Energiföretagen. ”Samling för nätkapacitet” samlade stort nätverk—Energiföretagen Sverige. Available online: https://www.energiforetagen.se/medlemsnyheter/2019/april/samling-for-natkapacitet-samlade-stort-natverk/ (accessed on 17 October 2019).
  24. Svenska kraftnät. Både Kort- och Långsiktiga Lösningar Behövs för att Möta Kapacitetsbristen. Available online: https://www.svk.se/om-oss/nyheter/allmanna-nyheter/2018/bade-kort--och-langsiktiga-losningar-behovs-for-att-mota-kapacitetsbristen/ (accessed on 13 May 2019).
  25. Gustafsson, M.S.; Myhren, J.A.; Dotzauer, E. Mapping of Heat and Electricity Consumption in a Medium Size Municipality in Sweden. Energy Procedia 2017, 105, 1434–1439. [Google Scholar] [CrossRef]
  26. Alarcon-Rodriguez, A.; Ault, G.; Galloway, S. Multi-objective planning of distributed energy resources: A review of the state-of-the-art. Renew. Sustain. Energy Rev. 2010, 14, 1353–1366. [Google Scholar] [CrossRef]
  27. Baños, R.; Manzano-Agugliaro, F.; Montoya, F.G.; Gil, C.; Alcayde, A.; Gómez, J. Optimization methods applied to renewable and sustainable energy: A review. Renew. Sustain. Energy Rev. 2011, 15, 1753–1766. [Google Scholar] [CrossRef]
  28. McKenna, R.; Bertsch, V.; Mainzer, K.; Fichtner, W. Combining local preferences with multi-criteria decision analysis and linear optimization to develop feasible energy concepts in small communities. Eur. J. Oper. Res. 2018, 268, 1092–1110. [Google Scholar] [CrossRef]
  29. Lez-Briones, A.G.; De La Prieta, F.; Mohamad, M.S.; Omatu, S.; Corchado, J.M. Multi-agent systems applications in energy optimization problems: A state-of-the-art review. Energies 2018, 11, 1928. [Google Scholar] [CrossRef] [Green Version]
  30. Mendes, G.; Ioakimidis, C.; Ferrão, P. On the planning and analysis of Integrated Community Energy Systems: A review and survey of available tools. Renew. Sustain. Energy Rev. 2011, 15, 4836–4854. [Google Scholar] [CrossRef]
  31. Lyden, A.; Pepper, R.; Tuohy, P.G. A modelling tool selection process for planning of community scale energy systems including storage and demand side management. Sustain. Cities Soc. 2018, 39, 674–688. [Google Scholar] [CrossRef]
  32. Ringkjøb, H.K.; Haugan, P.M.; Solbrekke, I.M. A review of modelling tools for energy and electricity systems with large shares of variable renewables. Renew. Sustain. Energy Rev. 2018, 96, 440–459. [Google Scholar] [CrossRef]
  33. Scheller, F.; Bruckner, T. Energy system optimization at the municipal level: An analysis of modeling approaches and challenges. Renew. Sustain. Energy Rev. 2019, 105, 444–461. [Google Scholar] [CrossRef]
  34. Aalborg University. EnergyPLAN|Advanced Energy Systems Analysis Computer Model. Available online: https://www.energyplan.eu/ (accessed on 13 May 2019).
  35. Østergaard, P.A. Wind power integration in Aalborg Municipality using compression heat pumps and geothermal absorption heat pumps. Energy 2013, 49, 502–508. [Google Scholar] [CrossRef]
  36. Wänn, A.; Connolly, D.; Gallachóir, B.Ó. Investigating 100% renewable energy supply at regional level using scenario analysis. Int. J. Sustain. Energy Plan. Manag. 2014, 3, 21–32. [Google Scholar]
  37. Østergaard, P.A. Reviewing EnergyPLAN simulations and performance indicator applications in EnergyPLAN simulations. Appl. Energy 2015, 154, 921–933. [Google Scholar] [CrossRef]
  38. Novosel, T.; Pukšec, T.; Krajačić, G.; Duić, N. Role of District Heating in Systems with a High Share of Renewables: Case Study for the City of Osijek. Energy Procedia 2016, 95, 337–343. [Google Scholar] [CrossRef]
  39. Bačeković, I.; Østergaard, P.A. A smart energy system approach vs. a non-integrated renewable energy system approach to designing a future energy system in Zagreb. Energy 2018, 155, 824–837. [Google Scholar] [CrossRef]
  40. Cabrera, P.; Lund, H.; Carta, J.A. Smart renewable energy penetration strategies on islands: The case of Gran Canaria. Energy 2018, 162, 421–443. [Google Scholar] [CrossRef] [Green Version]
  41. Child, M.; Nordling, A.; Breyer, C. Scenarios for a sustainable energy system in the Åland Islands in 2030. Energy Convers. Manag. 2017, 137, 49–60. [Google Scholar] [CrossRef]
  42. Batas Bjelić, I.; Rajaković, N. Simulation-based optimization of sustainable national energy systems. Energy 2015, 91, 1087–1098. [Google Scholar] [CrossRef]
  43. Mahbub, M.S.; Cozzini, M.; Østergaard, P.A.; Alberti, F. Combining multi-objective evolutionary algorithms and descriptive analytical modelling in energy scenario design. Appl. Energy 2016, 164, 140–151. [Google Scholar] [CrossRef]
  44. Prina, M.G.; Cozzini, M.; Garegnani, G.; Manzolini, G.; Moser, D.; Filippi Oberegger, U.; Pernetti, R.; Vaccaro, R.; Sparber, W. Multi-objective optimization algorithm coupled to EnergyPLAN software: The EPLANopt model. Energy 2018, 149, 213–221. [Google Scholar] [CrossRef]
  45. Thellufsen, J.Z.; Nielsen, S.; Lund, H. Implementing cleaner heating solutions towards a future low-carbon scenario in Ireland. J. Clean. Prod. 2019, 214, 377–388. [Google Scholar] [CrossRef]
  46. Toffolo, A.; Benini, E. Genetic diversity as an objective in multi-objective evolutionary algorithms. Evol. Comput. 2003, 11, 151–167. [Google Scholar] [CrossRef] [PubMed]
  47. Vesterlund, M.; Toffolo, A. Design Optimization of a District Heating Network Expansion, a Case Study for the Town of Kiruna. Appl. Sci. 2017, 7, 488. [Google Scholar] [CrossRef] [Green Version]
  48. Connolly, D.; Lund, H.; Mathiesen, B.V.; Leahy, M. A review of computer tools for analysing the integration of renewable energy into various energy systems. Appl. Energy 2010, 87, 1059–1082. [Google Scholar] [CrossRef]
  49. Goel, T.; Stander, N. A non-dominance-based online stopping criterion for multi-objective evolutionary algorithms. Int. J. Numer. Methods Eng. 2010, 84, 661–684. [Google Scholar] [CrossRef]
  50. Pelletsförbundet Statistik|Pelletsförbundet. Available online: http://pelletsforbundet.se/statistik/ (accessed on 14 May 2019).
  51. Steinbach, J.; Staniaszek, D. Discount Rates in Energy System Analysis. Discussion Paper; Fraunhofer ISI, Buildings Performance Institute Europe (BPIE): Karlsruhe, Germany, 2015. [Google Scholar]
  52. García-Gusano, D.; Espegren, K.; Lind, A.; Kirkengen, M. The role of the discount rates in energy systems optimisation models. Renew. Sustain. Energy Rev. 2016, 59, 56–72. [Google Scholar] [CrossRef]
  53. Danish Energy Agency. Energinet Technology Data. Available online: https://ens.dk/en/our-services/projections-and-models/technology-data (accessed on 14 May 2019).
  54. Tsiropoulos, I.; Tarvydas, D.; Zucker, A. Cost Development of Low Carbon Energy Technologies; Joint Research Centre (JRC), European Commission: Brussels, Belgium, 2018. [Google Scholar]
  55. Moles, C.; Sigfusson, B.; Spisto, A.; Vallei, M.; Weidner, E.; Giuntoli, J.; Jäger-Waldau, A.; Lacal Arántegui, R.; Lazarou, S.; Magagna, D.; et al. Energy Technology Reference Indicator (ETRI) Projections for 2010–2050; EU Publications: Luxembourg, 2014. [Google Scholar]
  56. Koffi, B.; Cerutti, A.K.; Duerr, M.; Iancu, A.; Kona, A.; Janssens-Maenhout, G. Covenant of Mayors for Climate and Energy: Default Emission Factors for Local Emission Inventories-Version; EUR 28718 EN; Publications Office of the European Union: Luxembourg, 2017. [Google Scholar]
  57. Moro, A.; Lonza, L. Electricity carbon intensity in European Member States: Impacts on GHG emissions of electric vehicles. Transp. Res. Part D Transp. Environ. 2018, 64, 5–14. [Google Scholar] [CrossRef]
  58. Porsö, C. Rapportering av Energianvändningen och Växthusgasutsläppen 2017; Stockholms stad: Stockholm, Sweden, 2017. [Google Scholar]
  59. Wikman, Å. Klimat-och Energiplan Piteå; Piteå Kommun: Piteå, Sweden, 2010. [Google Scholar]
  60. Piteå Kommun. Sammanträdesprotokoll; Piteå Kommun: Piteå, Sweden, 2017. [Google Scholar]
  61. Piteå Kommun. Lägesrapport Uppföljning av Klimat-och Energiplanens Mål; Piteå Kommun: Piteå, Sweden, 2015. [Google Scholar]
  62. SCB. Statistikdatabasen. Available online: http://www.statistikdatabasen.scb.se/ (accessed on 15 May 2019).
  63. Statisticon AB. Befolkningsprognos 2018–2030 Piteå Kommun; Statisticon AB: Uppsala, Sweden, 2018. [Google Scholar]
  64. Energikontor. Norr Energiluppen. Available online: http://www.energiluppen.se/ (accessed on 15 May 2019).
  65. Piteå Kommun. Piteå Climate and Energy Plan 2010; Supporting Documents; Piteå Kommun: Piteå, Sweden, 2016. [Google Scholar]
  66. Piteå Industries. Energy Data of Local Industries in Piteå; Piteå Industries: Piteå, Sweden, 2016; (received by email from industrial representatives in May 2017). [Google Scholar]
  67. PiteEnergi AB. Årsredovisning och Koncernredovisning för AB PiteEnergi, Räkenskapsåret 2015; PiteEnergi AB: Piteå, Sweden, 2016. [Google Scholar]
  68. Swedish Energy Agency. Ny Samlingspublikation: Energistatistik för Småhus, Flerbostadshus och Lokaler 2013. Available online: http://www.energimyndigheten.se/nyhetsarkiv/2014/ny-samlingspublikation-energistatistik-for-smahus-flerbostadshus-och-lokaler-2013/ (accessed on 15 May 2019).
  69. Swedish Energy Agency. Bostäder och Lokaler. Available online: http://www.energimyndigheten.se/statistik/bostader-och-lokaler/ (accessed on 15 May 2019).
  70. Miljö- och Energidepartementet. Miljöbalk (1998:808); Sveriges Riksdag: Stockholm, Sweden, 1999. [Google Scholar]
  71. Svenska kyl och Värmepumpföreningen. Värmepumpsförsäljning. Available online: https://skvp.se/aktuellt-o-opinion/statistik/varmepumpsforsaljning (accessed on 15 May 2019).
  72. Piteå Kommun Vindbruksplan—Översiktsplan. Available online: https://www.pitea.se/Invanare/Boende-miljo/Planer-och-fysisk-planering/oversiktsplan-2030/Vindbruksplan/ (accessed on 15 May 2019).
  73. Sveriges Radio; P4 Norrbotten. Storsatsning på vindkraft i Piteå skärgård. Available online: https://sverigesradio.se/sida/artikel.aspx?programid=98&artikel=1022396 (accessed on 15 May 2019).
  74. Svenska Kraftnät. Integrering av Vindkraft; Svenska Kraftnät: Sundbyberg, Sweden, 2013. [Google Scholar]
Figure 1. Schematic diagram of the interface between EnergyPLAN (simulation) and the multi-objective evolutionary algorithm (MOEA) (multi-objective optimization).
Figure 1. Schematic diagram of the interface between EnergyPLAN (simulation) and the multi-objective evolutionary algorithm (MOEA) (multi-objective optimization).
Energies 13 00290 g001
Figure 2. Selected reference scenarios simulated in EnergyPLAN for the Piteå municipal energy system; pel = 40 EUR/MWh, pbio = 35 EUR/MWh.
Figure 2. Selected reference scenarios simulated in EnergyPLAN for the Piteå municipal energy system; pel = 40 EUR/MWh, pbio = 35 EUR/MWh.
Energies 13 00290 g002
Figure 3. Electricity sector, optimal results with three decision variables (PV, WindON and WindOFF), sensitivity analysis for pel and dr.
Figure 3. Electricity sector, optimal results with three decision variables (PV, WindON and WindOFF), sensitivity analysis for pel and dr.
Energies 13 00290 g003
Figure 4. Electricity sector, Pel,maximp with three decision variables (PV, WindON and WindOFF) sensitivity analysis for pel and dr.
Figure 4. Electricity sector, Pel,maximp with three decision variables (PV, WindON and WindOFF) sensitivity analysis for pel and dr.
Energies 13 00290 g004
Figure 5. Electricity and heating sectors, on top: (a) for the combination pel = LOW/pbio = HIGH, in the middle: (b) with pel = MED pio = MED, bottom: (c) with pel = HIGH/pbio = LOW. Optimal results with all decision variables for the electricity sector in rows 1, 3, and 5 (PV, WindON and WindOFF), decision variables for the heating sector in rows 2, 4, and 6 (BioB, HP, ElB), Ctot in all diagrams, nine cases in total for sensitivity analysis on pel/pbio and dr.
Figure 5. Electricity and heating sectors, on top: (a) for the combination pel = LOW/pbio = HIGH, in the middle: (b) with pel = MED pio = MED, bottom: (c) with pel = HIGH/pbio = LOW. Optimal results with all decision variables for the electricity sector in rows 1, 3, and 5 (PV, WindON and WindOFF), decision variables for the heating sector in rows 2, 4, and 6 (BioB, HP, ElB), Ctot in all diagrams, nine cases in total for sensitivity analysis on pel/pbio and dr.
Energies 13 00290 g005
Figure 6. Electricity and heating sectors, Pel,maximp with all decision variables, sensitivity analysis for pel and dr.
Figure 6. Electricity and heating sectors, Pel,maximp with all decision variables, sensitivity analysis for pel and dr.
Energies 13 00290 g006
Figure 7. Ctot compared for electricity only and integrated electricity and heating, pel = 40 EUR/MWh, pbio = 35 EUR/MWh.
Figure 7. Ctot compared for electricity only and integrated electricity and heating, pel = 40 EUR/MWh, pbio = 35 EUR/MWh.
Energies 13 00290 g007
Figure 8. Duration curves for electricity import (positive)/export (negative) [MW].
Figure 8. Duration curves for electricity import (positive)/export (negative) [MW].
Energies 13 00290 g008
Figure 9. Installed capacities for selected scenarios and cases.
Figure 9. Installed capacities for selected scenarios and cases.
Energies 13 00290 g009
Table 1. Grid emissions factors EFgrid in Sweden 2015.
Table 1. Grid emissions factors EFgrid in Sweden 2015.
Sweden, EFgrid 2015ValueUnit
NEEFE (IPCC standard)0.0150tCO2/MWh
NEEFE (IPCC standard+)0.0160tCO2eq/MWh
NEEFE (LCA)0.0380tCO2eq/MWh
Nordic electricity mix 20150.0665tCO2eq/MWh
Nordic electricity mix 20100.1000tCO2eq/MWh
Table 2. Piteå municipality, key figures 2015.
Table 2. Piteå municipality, key figures 2015.
Population, Land AreaValueUnitReferences *
Population41,548[1][62]-BE0101
Population expected by 203043,069[1][63]
Land area3086[km2][62]-MI0802AA
Main Cities (Population >1000); HousingValueUnitReferences *
 Piteå (administrative seat)23,067[1][62]-BE0101
 Bergsviken2251[1][62]-BE0101
 Rosvik1848[1][62]-BE0101
 Norrfjärden1562[1][62]-BE0101
 Roknäs1259[1][62]-BE0101
 Hortlax1128[1][62]-BE0101
Housing-number of dwellings19,273[1][62]-BO0104AE, BO0104AG
 In residential buildings11,509[1]
 In apartment buildings7384[1]
 In other buildings380[1]
Energy Consumption/ProductionValueUnitReferences *
Total final energy consumption5901[GWh][62]-EN0203AE
Total final electricity consumption1453[GWh][62]-EN0203AE, [64]
Municipal electricity production1117[GWh][62]-EN0203AD, [65]
 Industrial CHP499[GWh][66]
 Hydropower221[GWh][62]-EN0203AD, [67]
 Windpower397[GWh][62]-EN0203AD
Total heat production by DH269[GWh][62]-EN0203AC, [64]
 Industrial waste heat257[GWh][66]
 Heating centers (boilers)11[GWh][65]
Total heat energy consumption (no DH)238[GWh][62]-EN0203AE, [65,68,69]
 Electricity (direct)146[GWh][62]-EN0203AE, [65,68,69]
 Electricity (heat pump)20[GWh][62]-EN0203AE, [65,68,69]
 Biomass70[GWh][62]-EN0203AE, [65,68,69]
 Oil2[GWh][62]-EN0203AE, [65,68,69]
* references to SCB [62] include the internal reference code to the specific data.
Table 3. LCOE, Cann for PV, WindON, and WindOFF; Cann for ElB, BioB, and HP (calculations based on 2020 technology cost parameters as provided by the EnergyPLAN cost database).
Table 3. LCOE, Cann for PV, WindON, and WindOFF; Cann for ElB, BioB, and HP (calculations based on 2020 technology cost parameters as provided by the EnergyPLAN cost database).
LCOE [EUR/MWh]
Renewable Energy TechnologyCapacity Factordr = 3%dr = 9%dr = 15%
Solar PV (PV)12%4785130
Wind onshore (WindON)30%335070
Wind offshore (WindOFF)40%436899
Cann [EUR/kW]
Renewable Energy Technology dr = 3%dr = 9%dr = 15%
Solar PV (PV) 5089136
Wind onshore (WindON) 86130184
Wind offshore (WindOFF) 149239347
Cann [EUR/unit]
Heating Technology dr = 3%dr = 9%dr = 15%
Electric heating (ElB) 177316481
Biomass boiler (BioB) 93312121543
Air-air heat pump (AAHP) 185239300
Ground-source heat pump (GSHP) 106916192272
Heat pump mix: GS-AA-HP (HP) 71110011339
Table 4. Decision variables for local renewable electricity generation and heating technologies.
Table 4. Decision variables for local renewable electricity generation and heating technologies.
Renewable Electricity Generation TechnologyPV [MW]WindON [MW]WindOFF [MW]
 Minimum01450
 Discretization step13.66
 Maximum100505330
Heating TechnologyBioB [GWh]HP [GWh]ElB [GWh]
 Minimum000
 DiscretizationContinuous
 Maximum = heating demand211.7211.7211.7
Table 5. Selected results approximating near-zero electricity import/export-balance.
Table 5. Selected results approximating near-zero electricity import/export-balance.
UnitEnergyPLAN Demand2020EnergyPLAN Balanced2020Pareto Optimal Set (Electricity Only)Pareto Optimal Set (Electricity and Heating)
Imp/Exp-balance[GWh]0.3−6.5−60.6−1.55
Solar PV[MW]010060
Wind ON[MW]145145288253
Wind OFF[MW]06000
Heating (BioB|ElB|HP)[GWh]50.4|60|101.350.4|60|101.350.4|60|101.30|0|211.7
Total ann. cost[MEUR]77.788.281.379.6
CO2 reduction[%]-42.5%36.8%36.2%
Pel,maximp[MW]165.4160.0158.7152.7
Annual average pel = 40 EUR/MWh; pbio = 35 EUR/MWh; dr = 9%

Share and Cite

MDPI and ACS Style

Fischer, R.; Elfgren, E.; Toffolo, A. Towards Optimal Sustainable Energy Systems in Nordic Municipalities. Energies 2020, 13, 290. https://doi.org/10.3390/en13020290

AMA Style

Fischer R, Elfgren E, Toffolo A. Towards Optimal Sustainable Energy Systems in Nordic Municipalities. Energies. 2020; 13(2):290. https://doi.org/10.3390/en13020290

Chicago/Turabian Style

Fischer, Robert, Erik Elfgren, and Andrea Toffolo. 2020. "Towards Optimal Sustainable Energy Systems in Nordic Municipalities" Energies 13, no. 2: 290. https://doi.org/10.3390/en13020290

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.