Dynamic Electro-Thermal PV Temperature and Power Output Prediction Model for Any PV Geometries in Free-Standing and BIPV Systems Operating under Any Environmental Conditions

1
Engineering, Faculty of Science, University of East Anglia, Norwich NR4 7TJ, UK
2
Renewable Energy Systems Lab, University of Peloponnese, 26334 Patra, Greece
*
Author to whom correspondence should be addressed.
Energies 2020, 13(18), 4743; https://doi.org/10.3390/en13184743
Submission received: 5 August 2020 / Revised: 7 September 2020 / Accepted: 9 September 2020 / Published: 11 September 2020
(This article belongs to the Topic Electrothermal Modeling of Solar Cells and Modules)

Abstract

:
PV temperature significantly affects the module’s power output and final system yield, and its accurate prediction can serve the forecasting of PV power output, smart grid operations, online PV diagnostics and dynamic predictive management of Building Integrated Photovoltaic (BIPV) systems. This paper presents a dynamic PV temperature prediction model based on transient Energy Balance Equations, incorporating theoretical expressions for all heat transfer processes, natural convection, forced convection, conduction and radiation exchanges between both module sides and the environment. The algorithmic approach predicts PV temperature at the centre of the cell, the back and the front glass cover with fast convergence and serves the PV power output prediction. The simulation model is robust, predicting PV temperature with high accuracy at any environmental conditions, PV inclination, orientation, wind speed and direction, and mounting configurations, free-standing and BIPV. These, alongside its theoretical basis, ensure the model’s wide applicability and clear advantage over existing PV temperature prediction models. The model is validated for a wide range of environmental conditions, PV geometries and mounting configurations with experimental data from a sun-tracking, a fixed angle PV and a BIPV system. The deviation between predicted and measured power output for the fixed-angle and the sun-tracking PV systems was estimated at −1.4% and 1.9%, respectively. The median of the temperature difference between predicted and measured values was as low as 0.5 °C for the sun-tracking system, and for all cases, the predicted temperature profiles were closely matching the measured profiles. The PV temperature and power output predicted by this model are compared to the results produced by other well-known PV temperature models, illustrating its high predictive capacity, accuracy and robustness.

Graphical Abstract

1. Introduction

The modelling of photovoltaic (PV) temperature has received increased attention in recent years in an effort to accurately predict the power output and final yield of PV systems. The increase in PV temperature during PV operation leads to a significant reduction in module power output and operating efficiency, with the temperature coefficient for the maximum power Pm of a typical value −0.5%/°C for c-Si PV modules [1,2]. This translates to a reduction in PV power output from the rated peak power in the range of 5–25%, due to PV temperature alone, considering 1000 W/m2 solar irradiance incident on the PV plane. The effect is in the higher end of this range for Building Integrated Photovoltaic (BIPV) systems [3]. This has led to the need for accurate PV temperature prediction models to serve the forecasting of PV power output and smart grid operations, optimum PV system sizing, online PV diagnostics and the dynamic predictive management of BIPV in Intelligent Energy Buildings.
Several empirical and semi-empirical PV temperature models have been proposed in the research literature, mainly taking into account the solar irradiance on the PV plane IT, the ambient temperature Tα, and the wind speed vw. These include the well-known models by King et al. [4], Faiman [5], and others, as reviewed in [6,7,8].
King et al. [4] have proposed the exponential form of Equation (1) for the estimation of PV temperature at the back of the module TPVb and the temperature of the cell at the centre TPVc given by Equation (2), for both free-standing and insulated back modules
T P V b = T a + I T · e ( a + b · v w )
T P V c = T P V b + Δ Τ · Ι Τ / 1000
where coefficients α, b were empirically determined and were defined along with the temperature difference ΔΤ between the centre of the cell and the back of the module, according to the following [4]:
a = −3.56, b = −0.0750, ΔΤ = 3 °C for glass/cell/polymer sheet, open rack module;
a = −2.81, b = −0.0455, ΔΤ = 0 °C for glass/cell/polymer sheet, insulated back module.
Faiman has proposed the following model [5]
T p v = T a + I T / ( U o + U 1 · v w )
where U o ,   U 1 are empirically determined coefficients with average values: U o = 25   W m 2 K 1 and U 1 = 6.84   W m 3 s K 1 .
PV module technology, structure and mounting configurations have been considered in the above models through the empirically determined coefficients, while validation of these models’ applicability at different climatic regions is presented in [9].
NN-based models have been proposed, such as the model by Tamizhmani et al. [10], independent of site location and technology type, and expressed through Equation (4).
T p v = 0.943 T a + 0.028 I T 1.528 v w + 4.3
Multiple regression analysis and numerical approaches have also been proposed with promising results [11,12]. Several theoretical models based on the Energy Balance Equation (EBE), both steady-state and transient have been developed, such as [13,14,15,16,17,18,19,20]. However, these make use of empirical models for the determination of the air-forced convection coefficient or other simplifications and assumptions, while the geometry of the PV modules with respect to the wind direction is neglected or only considered through existing empirical expressions for the windward or leeward side. These limit the models’ applicability to the experimental setup and conditions, based on which these empirical expressions were derived. It was previously shown by the authors [21] that the air-forced convection coefficient has a significant effect on the Tpv prediction, highlighting the importance of theoretical models over empirical ones for the determination of the air-forced convection coefficient. The simulation model developed in [21] determines the f coefficient in Equation (5) based on theoretical expressions for the heat convection coefficients, with a separate approach to the windward and leeward side of the module, at any PV inclination, orientation and wind direction. It determines the natural convection at any PV inclination angle for the front and back side of the PV module, and the radiation exchanges between the module, front and back PV side, and the environment. Therefore, the f coefficient incorporates all these effects
T p v = T a + f · I T
f = ( τ α ) η p v U L , f + U L , b
where (τα) is the transmittance-absorptance product and ηpv the operating PV efficiency. UL,f and UL,b are the thermal losses coefficients for the front and back PV side, respectively, including both convective and radiative heat transfer processes, as analyzed in Section 2. The aforementioned analysis for the heat transfer and radiative heat processes was incorporated in [22] within a steady state model and proved to provide promising results for the prediction of PV temperature at any mounting configurations and steady state conditions.
The literature review in PV temperature and power output prediction discloses the need for a model satisfying all the following requirements:
  • To be theoretically robust, complete, and reliable;
  • To be based on a full set of expressions to accurately describe all the electro-thermal processes within the module, and between the module and the environment;
  • To respond to varying environmental conditions (ambient temperature, solar irradiance, wind speed, wind direction), incorporating transient effects
  • To be applicable to any PV geometry (inclination, orientation) and mounting configuration (free-standing, BAPV, BIPV);
  • To be accurate and validated with experimental data across a wide range of conditions.
In this paper, a dynamic PV temperature and power output prediction model is developed and validated, fully addressing all the aforementioned issues answering this gap in the literature view. The model is based on a set of Energy Balance Equations of transient form incorporating theoretical expressions for all heat transfer processes within the cell and towards the environment, including natural convection, forced convection, conduction and radiation exchanges between both module sides and the environment. The algorithmic approach predicts PV temperature at the centre of the cell, the back and the front glass cover with fast convergence and serves the PV power output prediction. The simulation model is robust, predicting PV temperature with high accuracy at any environmental conditions, PV inclination, orientation, wind speed and direction, and mounting configurations, free-standing and BIPV. These alongside its theoretical basis ensure the model’s wide applicability and clear advantage over existing PV temperature prediction models. The model is validated with the experimental data of over a year, covering a wide range of environmental conditions, PV geometries and mounting configurations from a sun-tracking, a fixed angle PV, and a BIPV system, while it is further compared to the results produced by the aforementioned PV temperature models [4,5,10], illustrating its high predictive capacity, accuracy and robustness.
This model applies to in-land systems, and therefore limitations may be identified with regards to PV operating in fresh water or sea environments, Floating PV (FPV) systems, or water content in the air, as well as cases of Concentrating PV (CPV) systems, or PV thermal (PV/T), but it may be adapted to additionally address these cases in the future. It is developed for conventional c-Si PV module technology glass-to-Tedlar, but may be easily adapted through the material properties to cover glass-to-glass or other module and PV technologies.

2. Transient PV Temperature and Power Output Prediction Model

The energy balance equation for transient conditions considers (1) the incident solar irradiance converted into electrical power within the cell with operating efficiency ηc, (2) the resistance to heat conduction from the cell to the glass Rc−f and to the back surface Rc−b including that of EVA, (3) the heat transfer through natural and forced convection from the front and the back PV module side, through UL,f and UL,b, respectively; the latter include the radiative heat exchanges between the module sides and the environment—sky and ground—and (4) the thermal energy stored in the layers of the module, and is described by the following equations.
( m c p ) t o t a l d T P V c d t = ( ( τ α ) η c ) I T ( T P V c T a ) ( 1 R c f + 1 U L , f + 1 R c b + 1 U L , b )
( ( m c p ) g l a s s + ( m c p ) E V A ) d T P V f d t = ( T P V c T P V f ) ( 1 R c f ) ( T P V f T a ) U L , f
( ( m c p ) t e d l a r + ( m c p ) E V A ) d T P V b d t = ( T P V c T P V b ) ( 1 R c b ) ( T P V b T a ) U L , b
The mass heat capacity (mcp) for the various layers of the module is expressed in the above equations normalised to the unit surface, with value for the front glass 4500 JK−1m−2, the EVA 502 JK−1m−2, the c-Si solar cell 355 JK−1m−2, and the Tedlar 150 JK−1m−2, [23]. (mcp)total = Σ(mcp)i, where i refers to each of the above layers. The material properties and geometry of the different layers are provided in [23].
For sun-tracking PV systems (τα) is considered equal to the transmittance-absorptance product at normal incidence (τα)n; a typical value in this case is 0.86. For a fixed angle PV system or BIPV system, the (τα) product is strongly affected by the angle of incidence of solar irradiance on the PV plane throughout the day and is determined through Equation (10) considering the beam, diffuse and ground-reflected irradiance components, [24].
( τ α ) ( τ α ) n = I b R b ( τ α ) b ( τ α ) n + I d ( τ α ) d ( τ α ) n ( 1 + c o s β ) 2 + r I ( τ α ) r ( τ α ) n ( 1 c o s β ) 2 I T
The ratio of the transmittance-absorptance product at a certain angle of incidence to the transmittance-absorptance product at normal incidence, is known as the incidence angle modifier (IAM) or Kτα. Here, Kτα for each of the three components, beam, diffuse and ground-reflected, (τα)b/(τα)n, (τα)d/(τα)n and (τα)r/(τα)n respectively, is estimated based on Equation (11), with bo = 0.136 using for the beam component the incidence angle θ, and for the diffuse and ground-reflected components the effective angle of incidence of the diffuse radiation θd and the effective angle of incidence of the ground-reflected radiation θr respectively, according to well-known expressions provided in [24].
K τ α = 1 b o ( 1 c o s θ 1 )
The thermal losses coefficients for the front and back PV side are given by
U L , f = h c , g a + h r , g a
U L , b = h c , b a + h r , b a
where hc,g−a and hc,b−a the overall heat convection coefficient from the module glass and the module back surface to the environment considering natural and forced convection. For the determination of the overall value of h, the Grashof number, Reynolds number and ratio GrL/ReL2 are estimated as defined in [25] and, specifically, in case (a) GrL << ReL2 the natural convection is neglected, (b) GrL >> ReL2 the forced convection is neglected, (c) 0.01 < GrL/ReL2 < 100 combined natural and forced convection is considered. The combined natural and forced flow is estimated through Churchill’s expressions, with m = 3 [26]
h c , g a m = h c , g a   ( n a t u r a l ) m + h c , g a   ( f o r c e d ) m
h c , b a m = h c , b a   ( n a t u r a l ) m ± h c , b a   ( f o r c e d ) m
The natural heat convection coefficient from PV glass to the environment hc,g−a (natural) and PV back surface to the environment hc,b−a (natural) is determined through the Nu number from the general expression: N u = h · L / k a , where L is the length of the module along the natural air flow direction and ka is the thermal conductivity of air at the boundary layer temperature. All fluid properties are calculated at the boundary layer temperature for the front and back PV module side accordingly. The boundary layer temperature Tbl for each of the sides is estimated according to the predicted PV temperature at the respective PV side, based on the expression Tbl = TPV 0.25(TPV − Ta). This is updated in each iterative process, as described further below. The Nu number is estimated for the front PV side Nuf, considering a hot surface facing upward and the back PV side Nub, considering a hot surface facing downward according to the expressions analysed by the authors in [21] for the entire range of PV inclination angles.
The simulation model takes into consideration the wind velocity and its direction, the PV module orientation and inclination, and determines the windward and leeward side of the PV module whether front or back, for the determination of the air-forced heat convection coefficient h. The latter for the windward side of the module is estimated based on the Sartori’s expressions according to the air flow whether laminar, fully turbulent or mixed, Equation (14a–c), [27]. These were shown to lead to very accurate predictions of the f coefficient [21]. This includes the decay of the heat transfer along the length of the surface in the wind direction L. The type of flow is evaluated based on the ratio xc/L ≥ 0.95, xc/L ≤ 0.05 and xc/L < 0.95 for the laminar, fully turbulent and mixed flows respectively, where xc is the critical length based on the critical Reynolds number Rex,c.
h = 3.83 · v w 0.5 · L 0.5   f o r   l a m i n a r   f l o w
h = 5.74 · v w 0.8 · L 0.2     f o r   f u l l y   t u r b u l e n t   f l o w
h = 5.74 · v w 0.8 · L 0.2 16.46 · L 1           f o r   m i x e d   f l o w s
For the leeward side of the PV module, the above expressions were used in the model but with L given by 4A/S, where A the area of the module and S its perimeter [21].
The thermal radiation coefficients hr,g−a and hr,b−a for the front and the back side of the PV module were considered as normalised to the difference between the PV temperature and the ambient to correct for the incorporation of the radiative exchanges in the EBE such that radiative heat transfer is taken with respect to the ambient Tα rather than the sky Ts or ground temperature Tgrd. According to this, the normalised coefficients in the EBE are given by
h r , g a = ε g F p v , f s k y σ T P V f 4 T s 4 T P V f T a + ε g F p v , f g r d σ T P V f 4 T g r d 4 T P V f T a
h r , b a = ε b F p v , b s k y σ T P V b 4 T s 4 T P V b T a + ε b F p v , b g r d σ T P V b 4 T g r d 4 T P V b T a
where εg is the emissivity of the glass cover and εb the emissivity of the module back surface which were measured using an ET10 emissometer equal to 0.85 and 0.91 respectively. σ is the Stefan-Boltzmann constant 5.67 10−8 W/m2K.
Tgrd is the ground temperature, and Ts is the sky temperature T s = 0.0552 · T a 1.5 [24]. The view factors from the PV front or back to the sky and ground respectively, depend on the inclination angle β of the PV plane with respect to the horizontal, and are given by
F p v , f - s k y = ( 1 + c o s β ) / 2
F p v , f - g r d = ( 1 c o s β ) / 2
F p v , b - s k y = ( 1 + cos ( π β ) ) / 2
F p v , b - g r d = ( 1 cos ( π β ) ) / 2
In BIPV systems, the normalised radiative heat transfer coefficient for the back PV side facing the indoor environment with temperature Troom is given by
h r , b - i n d = ε b σ T P V b 4 T r o o m 4 T P V b T a
From the transient EBE Equations (7)–(9), the PV temperature at the centre of the cell TPVc, the front glass TPVf, and the back PV surface TPVb at time t are estimated based on their previous value at time (t − 1) according to the following.
For free-standing PV systems:
T P V c ( t ) = [ T P V c ( t 1 ) + d t ( m c p ) t o t a l ( ( ( τ α ) η c ) I T + T a ( 1 R c f + 1 U L , f + 1 R c b + 1 U L , b ) ) ] /   [ 1 + d t ( m c p ) t o t a l ( 1 R c f + 1 U L , f + 1 R c b + 1 U L , b ) ]
T P V f ( t ) = [ T P V f ( t 1 ) + d t ( m c p ) g l a s s + ( m c p ) E V A ( T P V c R c f + U L , f T a ) ] / [ 1 + d t ( m c p ) g l a s s + ( m c p ) E V A ( 1 R c f + U L , f ) ]
T P V b ( t ) = [ T P V b ( t 1 ) + d t ( m c p ) t e d l a r + ( m c p ) E V A ( T P V c R c b + U L , b T a ) ] / [ 1 + d t ( m c p ) t e d l a r + ( m c p ) E V A ( 1 R c b + U L , b ) ]
For BIPV systems Equations (18) and (20) are replaced by Equations (21) and (22) respectively, to take into account the heat exchanges between the building integrated back PV side with the building interior.
T P V c ( t ) = [ T P V c ( t 1 ) + d t ( m c p ) t o t a l ( ( ( τ α ) η c ) I T + T a R c f + 1 U L , f + T r o o m R c b + 1 U L , b ) ] / [ 1 + d t ( m c p ) t o t a l ( 1 R c f + 1 U L , f + 1 R c b + 1 U L , b ) ]
T P V b ( t ) = [ T P V b ( t 1 ) + d t ( m c p ) t e d l a r + ( m c p ) E V A ( T P V c R c b + U L , b T r o o m ) ] / [ 1 + d t ( m c p ) t e d l a r + ( m c p ) E V A ( 1 R c b + U L , b ) ]
TPVc, TPVf, and TPVb at time t are initiated with guess values, in this case the nominal operating cell temperature TNOCT, TNOCT + 1, TNOCT + 2 respectively. The simulation converges very fast after a few iterations. In the cases studied, the simulation algorithm reached convergence in the second decimal point within 3–9 iterations.
In another equivalent approach to the iterative algorithmic process presented above, the PV temperature at the back of the module may be predicted from the following set of equations derived from transient EBEs, as derived by the authors in [23]. This requires only a couple of iterations to update the value of the Tpv dependent parameters: ηc, and the heat losses’ coefficients, approximating TPVf to TPVb in the determination of heat losses’ coefficients. The temperature at the back of the module TPVb at time t is expressed through the thermal time constant τ of the module, and may be estimated from Equations (23)–(27)
( F 1 F 2 ( T P V b ( t ) T a ) ) ( F 1 F 2 ( T P V b ( t 1 ) T a ) ) = e ( dt / τ )
where F1 represents the electric part of the process and F2 the thermal part, and are expressed by
F 1 = ( ( τ α ) η c ) I T / ( m c p ) e f
F 2 = ( U L , b + U L , f ( 1 + U L , b R c b 1 + U L , f R c g ) ) / ( m c p ) e f
The effective mass heat capacity (mcp)ef is expressed normalised to the unit surface and is defined as
( m c p ) e f = ( ( m c p ) t e d l a r + ( m c p ) E V A ) + ( m c p ) c e l l ( 1 / R c b ) + U L , b ( 1 / R c b ) + ( ( m c p ) g l a s s + ( m c p ) E V A ) ( 1 / R c g ) / ( 1 / R c g + U L , f ) ( 1 / R c b ) / ( 1 / R c b + U L , b )
The thermal properties, mass heat capacity and thermal conductivity of the different layer material are considered here at the same temperature. A maximum 3 °C temperature difference between the front glass and cell centre would have a negligible effect on the corresponding layer mass heat capacity value and further on (mcp)ef. This is justified by studies evaluating the effect of temperature on material mass heat capacity and conductivity, such as [28], whereby the mass heat capacity and conductivity of the glass, which is the main contributor in (mcp)ef, remains nearly constant in the temperature range of 20–70 °C, which is the typical PV temperature range observed during outdoor operation at a wide range of environmental conditions. The effect of 3 °C temperature difference on (mcp)glass is estimated 0.5%. The (mcp)ef in Equation (26) includes the effect of the different layer temperature through the heat transfer process, as implied through UL,f and UL,b.
Finally, the temperature at the back of the PV module at time t may be estimated by
T P V b ( t ) = T a + ( exp ( d t   · F 2 ) ( F 1 F 2 ( T P V b ( t 1 ) T a ) ) + F 1 ) / F 2
The testing carried out in this research reveals that the above set of expressions leads to equivalent results to the aforementioned iterative algorithmic process.
Having predicted the PV temperature at the centre of the cell TPVc, the power output and operating efficiency are estimated, through Equations (28) and (29), based on [13,29]
P m = P m , S T C · [ 1 + γ P m · ( T P V c 25   ° C ) + δ · ln ( I T / 1000 ) ] · ( I T / 1000 )
η p v = η S T C · [ 1 + γ P m · ( T P V c 25   ° C ) + δ · ln ( I T / 1000 ) ]
where γPm is the temperature coefficient for Pm and takes values in the region [−0.4, −0.5] %/°C provided by the module manufacturer, and δ the solar irradiance coefficient considered 0.085 for sc-Si and 0.11 for pc-Si modules [29].
P’m,STC and η’STC are the PV peak power and efficiency, respectively, at Standard Test Conditions (IT = 1000 W/m2, Air Mass 1.5, TPV = 25 °C) at the current state of the system considering the underlying ageing. PV degradation due to ageing is taken into account with an update to the Pm,STC and ηSTC values initially provided by the manufacturer, according the following
P m , S T C = P m , S T C ( 1 r a g e i n g )
η S T C = η S T C ( 1 r a g e i n g )
where rageing is the PV degradation due to ageing. In this study, 8% degradation is determined for the fixed-angle and 10% for the sun-tracking PV based on the 9 years of operation and verified by the separate I-V characterisation tests performed. Similarly, for the PV modules in the BIPV test cell operating for 14 years, 13% degradation was considered.
In this study a further 5% power losses due to cabling and mismatch losses have been taken into account at system level for the sun-tracking PV system according to (32)
P m , s y s = P m ( 1 ε l o s s e s )
where Pm,sys represents the final power output of the system and Pm the array output. εlosses represents the percentage of total additional power losses at system and array level.

3. Experimental Procedure

Experimental data obtained from three PV systems were used in this study for model validation, a double-axis sun-tracking pc-Si PV system with rated power 480 Wp, a fixed angle free-standing pc-Si PV system of the same capacity inclined at 37° and oriented 2.6° SE (Figure 1a), and a 110 Wp opaque sc-Si BIPV system integrated in the roof of a test cell (Figure 1b), with a 15° inclination angle and orientation 10° SW. The parameters monitored for a period of one year for the fixed and sun-tracking PV systems, include the module temperature TPVb at the back of the module via Cu-Const thermocouples, the solar irradiance incident on the plane of the PV modules via Kipp and Zonen CM11 pyranometers, for a period of 4 min at the beginning of every hour of the day, synchronised and combined with the respective minute recordings of ambient temperature, wind speed and wind direction monitored via the adjacent meteo station. The instantaneous wind velocity was converted to a relative height of 1 m above the sun-tracking PV system, as detailed in [21]. The inclination angle β of the sun-tracking PV system varied from 12–88°, and orientation angles γPV from 64° to 295° (Figure 2), and therefore a wide range of PV geometry and wind incidence angles were tested. As the data were previously screened for clear sky days, additional data were captured for the duration of a month (May) covering a wide range of sky conditions to test performance under varying environmental conditions and monitor the system power output. For this, the I–V curve was automatically captured every hour at the corresponding time intervals and the Pm was extracted. The hourly data were then used to validate the simulation model across a range of conditions, inclination and orientation angles and PV power output.
To test the transient response of the model, additional data were captured from the BIPV system recorded in 1 min intervals for the duration of 32 days across the months April, May, and June. These included the PV temperature measured at the back of the PV module via Cu-Const thermocouple, indoor temperature in the test cell, and solar irradiance at horizontal. The diffuse solar radiation was also monitored at the same time intervals for the study of the BIPV system. Solar radiation at horizontal was converted to the inclined PV plane through Equations (10) and (11), calculating the incidence angle for the beam component and the effective angles for the diffuse and ground-reflected radiation at the minute time intervals.

4. Results and Discussion

The proposed dynamic temperature prediction model is tested with the BIPV system, where transient effects can be observed at 1-min interval recordings of PV temperature for a period of 32 days across April–May–June. Figure 3 shows the predicted TPVb profile at 1-min intervals in comparison with the PV temperature measured at the back of the module during a clear sky day in June, along with the predicted TPVc and TPVf profiles. The predicted TPVb profile is in close agreement to the measured one and follows the same time pattern, which reflects the effect of the total mass heat capacity (mcp) of the glass-EVA-cell-EVA-Tedlar which is incorporated in the transient model. The majority of the predicted values lie within 3 °C of the measured values. The high predictive capacity of the model is highlighted across the varying wind velocity, which rises from 1 m/s to spikes at 6–7 m/s with the front PV module side windward or leeward, as indicated in Figure 3.
The predicted temperature at the centre of the cell TPVc is, on average, equal to the temperature at the back TPVb, as expected for insulated back systems. The back PV side of the BIPV integrated in the roof experiences only natural heat convection and radiative heat exchanges with the room interior, while the front side experiences radiative exchanges with the sky and ground and heat convection natural and/or forced due to the incident wind leading to lower temperatures at the PV glass. Τhe temperature difference between the predicted TPVc and TPVb ranged from 0 to 0.4 °C, while the difference of the predicted TPVc and TPVf ranged from 0 to 2.7 °C across the entire period tested. This is in agreement with the range of values previously reported by King et al. [4] of a 0 °C temperature difference between the centre of the cell and the back surface for insulated back PV module mounting configurations.
An insight into the profiles of the convection coefficients and their influence on the predicted TPVb profile is also provided in Figure 3. It may be observed that at instances of no wind the hc,g-a profile is driven by natural convection, while at instances of high wind it is dominated by forced convection coinciding with hc,g-a (forced), while at instances between 90–490 min, hc,g-a is mostly governed by mixed natural and forced convection. The forced convection profile both for the windward and leeward front side was laminar, as is expected for the majority of these cases of wind flow over flat surfaces in this range of wind speeds. At the back side of the BIPV module, forced convection is not relevant, and therefore the hc,b-a profile is only characterised by natural convection.
The sudden drop in the predicted temperature profiles at the 690 min is a result of a lower input irradiance due to shading effects on the pyranometer, before the shading also impacted the PV modules at 710 min. This is clearly shown in the drop in measured irradiance on the PV plane in Figure 4. At that time, the measured PV temperature experienced an exponential decay which is explained through Equation (23). The predicted TPVb profile responding to the irradiance drop also follows an exponential decay whose analysis gives a time constant equal to 5.5 min. This is in agreement with the theoretically derived τ = 1/F2 and slightly higher than the time constant 4.5 min reported in [23] for free-standing PV, as expected, since τ increases with (mcp)total and decreases with U.
The TPVb temperature profile predicted by this model is further compared against those obtained with the semi-empirical models by King et al. [4], Faiman [5] and the NN model by Tamizhmani et al. [10] for the same day in Figure 4. For the case of BIPV, model [4] is used with the empirical coefficients corresponding to the glass/cell/polymer sheet module with an insulated back. Figure 4 shows significant differences of up to 10–20 °C between the predicted TPV profiles by the three models [4,5,10] and the measured TPVmeas, which is generally more pronounced at higher wind speeds. Model [4] has a better response at higher wind speeds rather than low, while models [5,10] respond better at low wind speeds, displaying higher differences from the measured temperature at wind speeds greater than 3 m/s. The superiority of the proposed dynamic model compared to the other models is illustrated through the close agreement to the measured data across the entire range of wind speed values. Similar results are shown in Figure 5 for the performance of this model and in comparison to models [4,5,10] over 5 consecutive days in June across a wide range of wind velocities. Figure 6 and Figure 7 highlight the effectiveness of this model during cloudy and overcast days in April and for a wide range of wind velocities. The predicted vs. measured PV temperature is presented in Figure 8 illustrating an excellent agreement.
The proposed dynamic model is also tested with the free-standing PV systems, covering a wide range of PV geometries, azimuth and inclination angles, as actualised via the double-axis sun-tracking PV system, and a wide range of wind velocities during the period of 1 year at clear-sky conditions, as well as for an additional period of 1 month at varying sky conditions. In this case, the 1 h interval recordings hide the transient effects and the model response resembles that of a steady state model [22] exhibiting an improved performance over varying environmental conditions. The TPVb predicted profiles for the sun-tracking system during a period of clear sky days and a period of partly cloudy days are shown in Figure 9 and Figure 10. The predicted profiles lie very close to the measured ones with a temperature difference in the majority of the cases throughout the year in the range of ±5 °C, and better overall performance compared to that of the models [4,5,10]. The median of the temperature difference was 0.5 °C and the 25th and 75th percentiles were −1.2 and 2.2 °C, respectively, as shown in Table 1. The empirical coefficients in model [4] correspond in this case to the open rack module. Although the models [4,5,10] perform very well in the free-standing system, models [4,5] appear to under-estimate the PV temperature as shown in the boxplots in Figure 11, whereas model [10] predicts for the majority of the cases close to the measured data. A further comparison is shown in Figure 9 with the result obtained from the alternative approach using Equations (23)–(27), which shows very close results with the proposed TPVb simulation model.
The temperature difference between the predicted TPVc and TPVb for the sun-tracking system ranges from 0 to 0.6 °C and the difference between TPVc and TPVf from 0–2.1 °C. Research studies [4,13,23,30] reported a 1–3 °C difference between the PV cell temperature and the Tedlar or the glass. While the latter is in agreement with the results of the present study, the difference between the cell centre and the Tedlar is shown to be much lower here. In [30], the glass temperature was experimentally measured and theoretically calculated to be lower than the Tedlar temperature, which is also supported by the results of the present study.
The predicted and measured temperature profiles are also examined for the fixed-angle PV system for the duration of 1 month in May covering a range of environmental conditions. Similar temperature differences were observed as with the sun-tracking system between predicted and measured PV temperature. The measured and modelled PV temperatures follow the solar irradiance profile and the impact of high wind velocities is shown to reduce both measured and predicted values (Figure 12). Based on the predicted TPVc, the power output of the PV array is estimated from Equations (28) and (30). Power conditioning losses and further miscellaneous losses including optical losses may be additionally considered according to the system configuration. The predicted Pm profiles are compared to the measured hourly power output for the fixed-angle PV system and are shown in Figure 13. For the majority of the data, the power difference between predicted and measured lies in the range of 0–15 W, which corresponds to a deviation of less than 3.3%. This may be partly attributed to the difference between predicted and actual PV temperature at the centre of the cell. A 5 °C difference translates to 2.5% reduction in power output due to temperature alone, highlighting the importance of accurate PV temperature prediction.
The model’s predictive capacity is validated against extended experimental results of power output for the fixed-angle and the sun-tracking PV systems. The predicted vs. measured power output is displayed in Figure 14 and Figure 15 for the two systems and compared to the performance of the other models. Further analysis of the deviations between predicted and measured (ΔPm) showed the best fit achieved through Generalized Extreme Value distribution. According to this, the model leads to a mean underestimation of power output by 1.4% in the fixed-angle system and a mean overestimation by 1.9% in the sun-tracking system. As shown in Figure 14a, the underestimation in the fixed-angle system concerns mainly lower power values and very similar results are achieved by the other models too (Figure 14b–d). In the sun-tracking system, the small overestimation occurs in the high power values, as shown in Figure 15a. Similar results are obtained with the other models exhibiting a mean underestimation by 1.2–1.4% in the fixed angle system and a mean overestimation in the range of 2.7–3.6% in the sun-tracking system. The difference in the prediction of Pm between models is 1–2%, with the proposed model exhibiting a better performance with predictions closer to the measured data.

5. Conclusions

A dynamic electro-thermal PV temperature prediction model is presented based on transient Energy Balance Equations, incorporating theoretical expressions for all heat transfer processes for both sides of the PV module, natural convection, forced convection, conduction and radiation exchanges between the module and the environment. The simulation model takes as input the environmental parameters, solar irradiance, ambient temperature, wind speed and wind direction, as well as the PV geometry parameters, PV inclination and orientation, and mounting configuration and predicts the PV temperature at the centre of the cell, the back surface and the front glass cover, the PV power output and efficiency. The algorithmic approach leads to fast convergence within 3–9 iterations. A set of equations mathematically derived from the transient EBEs is also presented, and may be alternatively used together with the complete set of theoretical expressions presented for the heat transfer processes to produce very similar results.
The model is validated with experimental data for a wide range of environmental conditions, PV geometry, and mounting configurations with data captured from a BIPV system, a double-axis sun-tracking PV, and a fixed-angle free standing PV system, and showed excellent agreement with the measured data. The transient effects were analysed through PV temperature prediction profiles for the BIPV system, and the total mass heat capacity of the glass-EVA-cell-EVA-Tedlar, together with the total energy losses coefficient, is shown to accurately predict its response. The transient model’s response to variations in the irradiance has revealed a time constant for the BIPV module of 5.5 min. The temperature difference between the centre of the cell and the back surface for all systems and conditions studied lies in the range from 0 to 0.6 °C, whereas the difference between the centre of the cell and the front glass cover in the range from 0 to 2.6 °C. The model is tested with a wide range of inclination angles ranging from 12 to 88° and orientations from 64 to 295° and the effectiveness of the model is illustrated across a range of environmental conditions, varying global and diffuse irradiance, ambient temperature, wind velocities and the windward/leeward side of the module. The median of the temperature difference between predicted and measured values was as low as 0.5 °C for the sun-tracking system, and for all cases the predicted temperature profiles closely matched the measured profiles.
Validation of the model was also carried out in terms of power output, where the predicted vs. measured PV power output proved to have excellent performance both for the fixed and the sun-tracking PV systems. Specifically, the model leads to a mean underestimation of power output by 1.4% in the fixed-angle system and a mean overestimation by 1.9% in the sun-tracking system. The difference between the predicted and measured PV power output is mainly attributed to the accuracy in the prediction of PV cell temperature and also includes ageing effects and miscellaneous optical and power losses.
The dynamic PV temperature prediction model was also compared to three well-known models, and the results showed that it has a clearly better performance and prediction capacity for a wide range of conditions and mounting configurations. The dynamic model is robust and has a firm theoretical basis, providing high accuracy and wide applicability, which may serve the needs for online PV monitoring and diagnostics and dynamic predictive management of BIPV.

Author Contributions

Conceptualization, E.K.; methodology, E.K.; software, E.K.; validation, E.K.; formal analysis, E.K.; investigation, E.K. and S.K.; resources, S.K. and E.K.; data curation, E.K. and S.K.; writing—original draft preparation, E.K.; writing—review and editing, E.K. and S.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

GrGrashof number
ITglobal solar irradiance on the surface of the PV module (W/m2)
Ib, Idbeam and diffuse solar irradiance, respectively, at horizontal (W/m2)
Kταincidence angle modifier (dimensionless)
Llength of the PV module in the direction of the natural air flow along its front or back side, or as otherwise stated in the text (m)
Nuf, Nubthe Nusselt number of the air flow in the front and back side of the PV module, respectively
ReReynolds number
Pm, Pm,STCPV peak power at operating conditions and Standard Test Conditions, respectively (W)
Rc−f, Rc−bresistance to heat conduction from cell to glass, and cell to back surface, respectively (m2K/W)
TPVf, TPVc, TPVbPV temperature at the front, cell centre, and back surface, respectively (°C or K)
Taambient temperature (°C)
Tgrdground surface temperature (K)
Tssky temperature (K)
UL,f, UL,bheat losses coefficient due to convection and IR radiation at the front and back side of the PV module, respectively (W/m2K)
hc,g−a, hc,b−aheat convection coefficient from PV glass to environment, and back surface to environment, respectively (W/m2K)
hr.g−a, hr,b−aradiative heat losses coefficient from PV glass to environment, and back surface to environment, respectively (W/m2K)
hr,b−indradiative heat losses coefficient from PV back surface to the indoor environment (W/m2K)
kathermal conductivity of air (W/mK)
rageingdegradation of the PV system due to ageing (%)
vwwind velocity (m/s)
(mcp)cell, (mcp)EVA, (mcp)glass, (mcp)Tedlarmass heat capacity of cell, EVA, glass, Tedlar, respectively, normalised to the unit surface (JK−1m−2)
(τα), (τα)ntransmittance-absorptance product at θ incidence angle and at normal incidence, respectively (dimensionless)
βPV module inclination angle (degrees)
εg, εbemissivity coefficients for the PV glass and the back surface, respectively (dimensionless)
ηpv, ηSTCPV efficiency at operating conditions and at Standard Test Conditions, respectively (dimensionless)
θincidence angle of the beam irradiance (degrees)
τtime constant (s)

References

  1. King, D.L.; Kratochvil, J.A.; Boyson, W.E. Temperature coefficients for PV modules and arrays: Measurement, methods, difficulties and results. In Proceedings of the 26th IEEE Photovoltaic Specialists Conference, Anaheim, CA, USA, 29 September–3 October 1997. [Google Scholar]
  2. Skoplaki, E.; Palyvos, J. On the temperature dependence of photovoltaic module electrical performance: A review of efficiency/power correlations. Sol. Energy 2009, 83, 614–624. [Google Scholar] [CrossRef]
  3. Kaplanis, S.; Kaplani, E. On the relationship factor between the PV module temperature and the solar radiation on it for various BIPV configurations. In Proceedings of the International Conference of Computational Methods in Sciences and Engineering 2014 (ICCMSE 2014), Athens, Greece, 4–7 April 2014; AIP Publishing: College Park, MD, USA, 2014; Volume 1618, pp. 341–347. [Google Scholar]
  4. King, D.L.; Boyson, W.E.; Kratochvill, J.A. Photovoltaic Array Performance Model, SANDIA Report SAND2004-3535; Sandia National Laboratories: Albuquerque, NM, USA, 2004. [Google Scholar]
  5. Faiman, D. Assessing the outdoor operating temperature of photovoltaic modules. Prog. Photovolt. Res. Appl. 2008, 16, 307–315. [Google Scholar] [CrossRef]
  6. Skoplaki, E.; Boudouvis, A.; Palyvos, J. A simple correlation for the operating temperature of photovoltaic modules of arbitrary mounting. Sol. Energy Mater. Sol. Cells 2008, 92, 1393–1402. [Google Scholar] [CrossRef]
  7. Schwingshackl, C.; Petitta, M.; Wagner, J.; Belluardo, G.; Moser, D.; Castelli, M.; Zebisch, M.; Tetzlaff, A. Wind Effect on PV Module Temperature: Analysis of Different Techniques for an Accurate Estimation. Energy Procedia 2013, 40, 77–86. [Google Scholar] [CrossRef] [Green Version]
  8. Jakhrany, A.Q.; Rigitand, A.R.H.; Samo, S.; Othman, A.K. Comparison of Solar Photovoltaic Temperature Models. World Appl. Sci. J. 2011, 14, 1–8, ISSN 1818-4952. [Google Scholar]
  9. Koehl, M.; Heck, M.; Wiesmeier, S.; Wirth, J. Modeling of the nominal operating cell temperature based on outdoor weathering. Sol. Energy Mater. Sol. Cells 2011, 95, 1638–1646. [Google Scholar] [CrossRef]
  10. Tamizhmani, G.; Ji, L.; Tang, Y.; Petacci, L.; Osterwald, C. Photovoltaic Module Thermal/Wind Performance: Long Term Monitoring and Model Development for Energy Rating; NREL/CD-520-33586; National Renewable Energy Lab.: Golden, CO, USA, 2003; pp. 936–939. [Google Scholar]
  11. Kamuyu, W.C.L.; Lim, J.R.; Won, C.S.; Ahn, H.-K. Prediction Model of Photovoltaic Module Temperature for Power Performance of Floating PVs. Energies 2018, 11, 447. [Google Scholar] [CrossRef] [Green Version]
  12. Prilliman, M.; Stein, J.S.; Riley, D.; Tamizhmani, G. Transient Weighted Moving-Average Model of Photovoltaic Module Back-Surface Temperature. IEEE J. Photovolt. 2020, 10, 1053–1060. [Google Scholar] [CrossRef]
  13. Mattei, M.; Notton, G.; Cristofari, C.; Muselli, M.; Poggi, P. Calculation of the polycrystalline PV module temperature using a simple method of energy balance. Renew. Energy 2006, 31, 553–567. [Google Scholar] [CrossRef]
  14. Notton, G.; Cristofari, C.; Mattei, M.; Poggi, P. Modelling of a double-glass photovoltaic module using finite differences. Appl. Therm. Eng. 2005, 25, 2854–2877. [Google Scholar] [CrossRef]
  15. Armstrong, S.; Hurley, W. A thermal model for photovoltaic panels under varying atmospheric conditions. Appl. Therm. Eng. 2010, 30, 1488–1495. [Google Scholar] [CrossRef]
  16. Jones, A.; Underwood, C. A thermal model for photovoltaic systems. Sol. Energy 2001, 70, 349–359. [Google Scholar] [CrossRef]
  17. Hayes, W.; Ngan, L. A Time-Dependent Model for CdTe PV Module Temperature in Utility-Scale Systems. IEEE J. Photovolt. 2014, 5, 238–242. [Google Scholar] [CrossRef]
  18. Migliorini, L.; Molinaroli, L.; Simonetti, R.; Manzolini, G. Development and experimental validation of a comprehensive thermoelectric dynamic model of photovoltaic modules. Sol. Energy 2017, 144, 489–501. [Google Scholar] [CrossRef]
  19. Hammami, M.; Torretti, S.; Grimaccia, F.; Grandi, G. Thermal and Performance Analysis of a Photovoltaic Module with an Integrated Energy Storage System. Appl. Sci. 2017, 7, 1107. [Google Scholar] [CrossRef] [Green Version]
  20. Aly, S.P.; Ahzi, S.; Barth, N.; Abdallah, A. Using energy balance method to study the thermal behavior of PV panels under time-varying field conditions. Energy Convers. Manag. 2018, 175, 246–262. [Google Scholar] [CrossRef]
  21. Kaplani, E.; Kaplanis, S. Thermal modelling and experimental assessment of the dependence of PV module temperature on wind velocity and direction, module orientation and inclination. Sol. Energy 2014, 107, 443–460. [Google Scholar] [CrossRef] [Green Version]
  22. Kaplani, E.; Kaplanis, S. PV Module Temperature Prediction at Any Environmental Conditions and Mounting Configurations. In Innovative Renewable Energy; Springer Science and Business Media LLC: Berlin, Germany, 2019; pp. 921–933. [Google Scholar]
  23. Kaplanis, S.; Kaplani, E. A New Dynamic Model to Predict Transient and Steady State PV Temperatures Taking into Account the Environmental Conditions. Energies 2018, 12, 2. [Google Scholar] [CrossRef] [Green Version]
  24. Duffie, J.A.; Beckman, W.A. Solar Engineering of Thermal Processes; Wiley: New York, NY, USA, 2013. [Google Scholar]
  25. White, J.M. Heat and Mass Transfer; Addison-Wesley Publishing: Boston, MA, USA, 2013. [Google Scholar]
  26. Churchill, S.W. A comprehensive correlating equation for laminar, assisting, forced and free convection. AIChE J. 1977, 23, 10–16. [Google Scholar] [CrossRef]
  27. Sartori, E. Convection coefficient equations for forced air flow over flat surfaces. Sol. Energy 2006, 80, 1063–1071. [Google Scholar] [CrossRef]
  28. Colak, S.C.; Aral, E. Optical and thermal properties of P2O5–Na2O–CaO–Al2O3:CoO glasses doped with transition metals. J. Alloys Compd. 2011, 509, 4935–4939. [Google Scholar] [CrossRef]
  29. Anderson, A.J. Photovoltaic Translation Equations: A New Approach. Final Subcontract Report NREL/TP-411-20279; Office of Scientific and Technical Information (OSTI): Oak Ridge, TN, USA, 1996. [Google Scholar]
  30. Tina, G.M. A Coupled Electrical and Thermal Model for Photovoltaic Modules. J. Sol. Energy Eng. 2010, 132, 024501. [Google Scholar] [CrossRef]
Figure 1. Experimental photovoltaic (PV) systems: (a) fixed-angle and two-axis sun-tracking PV; (b) building integrated photovoltaic (BIPV) test cell.
Figure 1. Experimental photovoltaic (PV) systems: (a) fixed-angle and two-axis sun-tracking PV; (b) building integrated photovoltaic (BIPV) test cell.
Energies 13 04743 g001
Figure 2. PV inclination and azimuth angles at the test positions of the sun-tracking, fixed-angle PV and BIPV systems.
Figure 2. PV inclination and azimuth angles at the test positions of the sun-tracking, fixed-angle PV and BIPV systems.
Energies 13 04743 g002
Figure 3. Predicted PV temperature profiles for the cell centre, the back surface and front glass cover by the proposed dynamic model compared to the measured temperature profile at the PV back surface of the BIPV system during 1 day in June, with time interval of 1 min. The convection coefficient profiles are also displayed along with the wind speed and an indication of whether the front side is windward (WW) or leeward (LW).
Figure 3. Predicted PV temperature profiles for the cell centre, the back surface and front glass cover by the proposed dynamic model compared to the measured temperature profile at the PV back surface of the BIPV system during 1 day in June, with time interval of 1 min. The convection coefficient profiles are also displayed along with the wind speed and an indication of whether the front side is windward (WW) or leeward (LW).
Energies 13 04743 g003
Figure 4. As in Figure 3, including also a comparison with the predicted temperature profiles as generated by using 3 other models.
Figure 4. As in Figure 3, including also a comparison with the predicted temperature profiles as generated by using 3 other models.
Energies 13 04743 g004
Figure 5. As in Figure 4, during 5 consecutive days in June, with interval 1 min.
Figure 5. As in Figure 4, during 5 consecutive days in June, with interval 1 min.
Energies 13 04743 g005
Figure 6. As in Figure 4, during a cloudy day in April, with interval 1 min.
Figure 6. As in Figure 4, during a cloudy day in April, with interval 1 min.
Energies 13 04743 g006
Figure 7. As in Figure 4, during an overcast day in April, with interval 1 min.
Figure 7. As in Figure 4, during an overcast day in April, with interval 1 min.
Energies 13 04743 g007
Figure 8. PV temperature predicted by the proposed dynamic model vs. measured values across the period April–May–June for the BIPV system and a wide range of environmental conditions.
Figure 8. PV temperature predicted by the proposed dynamic model vs. measured values across the period April–May–June for the BIPV system and a wide range of environmental conditions.
Energies 13 04743 g008
Figure 9. Predicted PV temperature profile by the proposed dynamic model compared to the measured temperature profile and the predicted temperature profiles generated by using 3 other models, for the sun-tracking PV system and during a period of 7 consecutive clear-sky days with time interval of 1 h. A further comparison is made with the temperature profile provided by the set of Equations (23)–(27).
Figure 9. Predicted PV temperature profile by the proposed dynamic model compared to the measured temperature profile and the predicted temperature profiles generated by using 3 other models, for the sun-tracking PV system and during a period of 7 consecutive clear-sky days with time interval of 1 h. A further comparison is made with the temperature profile provided by the set of Equations (23)–(27).
Energies 13 04743 g009
Figure 10. As in Figure 9, during a period of 5 consecutive partly cloudy days in May and time interval of 1 h. Note: time between the days is not continuous, the profiles are presented from sunrise to sunset.
Figure 10. As in Figure 9, during a period of 5 consecutive partly cloudy days in May and time interval of 1 h. Note: time between the days is not continuous, the profiles are presented from sunrise to sunset.
Energies 13 04743 g010
Figure 11. Boxplot of temperature difference ΔΤ between predicted and measured values for the proposed model in comparison to that of the other 3 models.
Figure 11. Boxplot of temperature difference ΔΤ between predicted and measured values for the proposed model in comparison to that of the other 3 models.
Energies 13 04743 g011
Figure 12. As in Figure 9, for the fixed-angle PV system during a period of 5 consecutive partly cloudy days in May and time interval of 1 h.
Figure 12. As in Figure 9, for the fixed-angle PV system during a period of 5 consecutive partly cloudy days in May and time interval of 1 h.
Energies 13 04743 g012
Figure 13. Predicted vs. measured power output for the fixed PV generator during the 5 consecutive days of Figure 12.
Figure 13. Predicted vs. measured power output for the fixed PV generator during the 5 consecutive days of Figure 12.
Energies 13 04743 g013
Figure 14. Pm predicted vs. measured for the fixed-angle PV system, by the (a) proposed model, (b) King’s model, (c) Faiman’s model, (d) Mani’s model.
Figure 14. Pm predicted vs. measured for the fixed-angle PV system, by the (a) proposed model, (b) King’s model, (c) Faiman’s model, (d) Mani’s model.
Energies 13 04743 g014
Figure 15. Pm predicted vs. measured for the sun-tracking PV system, by the (a) proposed model, (b) King’s model, (c) Faiman’s model, (d) Mani’s model.
Figure 15. Pm predicted vs. measured for the sun-tracking PV system, by the (a) proposed model, (b) King’s model, (c) Faiman’s model, (d) Mani’s model.
Energies 13 04743 g015
Table 1. ΔΤ statistics between predicted and measured values for this model and the other 3 models.
Table 1. ΔΤ statistics between predicted and measured values for this model and the other 3 models.
StatisticΔTPVb,model (°C)ΔTKing (°C)ΔTFaiman (°C)ΔTMani (°C)
Median0.5−4.1−3.2−1.0
25th percentile−1.2−6.2−5.4−3.0
75th percentile2.2−2.3−1.20.6

Share and Cite

MDPI and ACS Style

Kaplani, E.; Kaplanis, S. Dynamic Electro-Thermal PV Temperature and Power Output Prediction Model for Any PV Geometries in Free-Standing and BIPV Systems Operating under Any Environmental Conditions. Energies 2020, 13, 4743. https://doi.org/10.3390/en13184743

AMA Style

Kaplani E, Kaplanis S. Dynamic Electro-Thermal PV Temperature and Power Output Prediction Model for Any PV Geometries in Free-Standing and BIPV Systems Operating under Any Environmental Conditions. Energies. 2020; 13(18):4743. https://doi.org/10.3390/en13184743

Chicago/Turabian Style

Kaplani, Eleni, and Socrates Kaplanis. 2020. "Dynamic Electro-Thermal PV Temperature and Power Output Prediction Model for Any PV Geometries in Free-Standing and BIPV Systems Operating under Any Environmental Conditions" Energies 13, no. 18: 4743. https://doi.org/10.3390/en13184743

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop