Research on Evaluation of Power Supply Capability of Active Distribution Network with Distributed Power Supply with High Permeability

1
Department of Electric Power Engineering, North China Electric Power University, Baoding 071003, China
2
Technical and Economic Consultation Center for Electric Power Construction in China Electricity Council, Beijing 100032, China
*
Authors to whom correspondence should be addressed.
Energies 2019, 12(11), 2223; https://doi.org/10.3390/en12112223
Received: 7 May 2019 / Revised: 6 June 2019 / Accepted: 10 June 2019 / Published: 11 June 2019
(This article belongs to the Special Issue Operation and Control of Power Distribution Systems)
  |  
PDF [2813 KB, uploaded 12 June 2019]
  |  

Abstract

With the large number of distributed generation (DG) access to the distribution network, the traditional distribution network with a single-supply radial structure has been transformed into an active distribution system (ADS) with source and bidirectional currents. This transformation makes the calculation of the power supply capacity (PSC) of the ADS face new challenges, and the uncertainty of the DG output increases the difficulty in calculating the PSC. At the same time, the power market transaction check needs to meet the safety constraints of the distribution network operation, and is required to know the PSC information of the ADS more quickly and accurately. Therefore, in order to quickly evaluate the PSC of the ADS, this paper proposes a fast evaluation method of the PSC based on the DG output rolling prediction and the information gap decision theory (IGDT). The method first establishes a rolling prediction model of the DG output, and calculates the PSC of the ADS at the corresponding time. Next, it establishes a risk avoidance model (RAM) and a risk speculation model (RSM) for the PSC of the ADS based on the IGDT. These models further calculate the probability of the range of the PSC at the corresponding time, so as to better evaluate the PSC of the ADS. Finally, the improved IEEE-14 node is used to verify that the model can consider the influence of the DG output uncertainty and quickly calculate the information of PSC. View Full-Text
Keywords: high permeability DG; uncertainty; rolling prediction; information gap decision theory; power supply capacity high permeability DG; uncertainty; rolling prediction; information gap decision theory; power supply capacity
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Ren, J.; Liang, H.; Gao, Y. Research on Evaluation of Power Supply Capability of Active Distribution Network with Distributed Power Supply with High Permeability. Energies 2019, 12, 2223.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Energies EISSN 1996-1073 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top