Next Article in Journal
Nonlinear Robust Control for Low Voltage Direct-Current Residential Microgrids with Constant Power Loads
Previous Article in Journal
Building “with the Systems” vs. Building “in the System” of IMS Open Technology of Prefabricated Construction: Challenges for New “Infill” Industry for Massive Housing Retrofitting
 
 
Article

Enhancing the Performance of Evacuated and Non-Evacuated Parabolic Trough Collectors Using Twisted Tape Inserts, Perforated Plate Inserts and Internally Finned Absorber

Thermal Department, School of Mechanical Engineering, National Technical University of Athens, Zografou, Heroon Polytechniou 9, 15780 Athens, Greece
*
Author to whom correspondence should be addressed.
Energies 2018, 11(5), 1129; https://doi.org/10.3390/en11051129
Received: 12 April 2018 / Revised: 26 April 2018 / Accepted: 1 May 2018 / Published: 3 May 2018
(This article belongs to the Section I: Energy Fundamentals and Conversion)
The thermal enhancement of parabolic trough collectors is a critical issue and numerous ideas have been applied in the literature on this domain. The objective of this paper is to investigate some usual thermal enhancement techniques for improving the performance of evacuated and non-evacuated receivers of parabolic trough solar collectors. More specifically, the use of twisted tape inserts, perforated plate inserts, and internally finned absorbers are compared with the reference case of the smooth absorber. The analysis is conducted with a developed and validated thermal model in Engineering Equation Solver. The collector is investigated for a typical flow rate of 100 L/min and for inlet temperatures between 50 °C and 350 °C with Syltherm 800 as working fluid. According to the final results, the use of internally finned absorber leads to the highest thermal efficiency enhancement, which is up to 2.1% for the non-evacuated collector and up to 1.6% for the evacuated tube collector. The perforated plate inserts and the twisted tape inserts were found to lead to lower enhancements, which are up to 1.8% and 1.5%, respectively, for the non-evacuated collector, while they are up to 1.4% and 1.2%, respectively, for the evacuated collector. Moreover, the pressure drop increase with the use of the thermal enhancement methods is investigated and the use of internally finned absorber is found again to be the superior technique with the performance evaluation criterion to be ranged from 1.5 to 1.8 for this case. View Full-Text
Keywords: thermal enhancement; parabolic trough collector; twisted tape insert; internal fin; perforated plate insert thermal enhancement; parabolic trough collector; twisted tape insert; internal fin; perforated plate insert
Show Figures

Figure 1

MDPI and ACS Style

Bellos, E.; Tzivanidis, C. Enhancing the Performance of Evacuated and Non-Evacuated Parabolic Trough Collectors Using Twisted Tape Inserts, Perforated Plate Inserts and Internally Finned Absorber. Energies 2018, 11, 1129. https://doi.org/10.3390/en11051129

AMA Style

Bellos E, Tzivanidis C. Enhancing the Performance of Evacuated and Non-Evacuated Parabolic Trough Collectors Using Twisted Tape Inserts, Perforated Plate Inserts and Internally Finned Absorber. Energies. 2018; 11(5):1129. https://doi.org/10.3390/en11051129

Chicago/Turabian Style

Bellos, Evangelos, and Christos Tzivanidis. 2018. "Enhancing the Performance of Evacuated and Non-Evacuated Parabolic Trough Collectors Using Twisted Tape Inserts, Perforated Plate Inserts and Internally Finned Absorber" Energies 11, no. 5: 1129. https://doi.org/10.3390/en11051129

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1