Next Article in Journal
Segmentation of Residential Gas Consumers Using Clustering Analysis
Previous Article in Journal
A Single-Phase Multilevel PV Generation System with an Improved Ripple Correlation Control MPPT Algorithm
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review

by
Yap Hoon
1,2,*,
Mohd Amran Mohd Radzi
1,2,
Mohd Khair Hassan
1 and
Nashiren Farzilah Mailah
1,2
1
Department of Electrical and Electronic Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
2
Centre for Advanced Power and Energy Research (CAPER), Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Selangor, Malaysia
*
Author to whom correspondence should be addressed.
Energies 2017, 10(12), 2038; https://doi.org/10.3390/en10122038
Submission received: 27 September 2017 / Revised: 25 October 2017 / Accepted: 30 October 2017 / Published: 3 December 2017

Abstract

Current harmonics is one of the most significant power quality issues which has attracted tremendous research interest. Shunt active power filter (SAPF) is the best solution to minimize harmonic contamination, but its effectiveness is strictly dependent on how quickly and accurately its control algorithms can perform. This manuscript reviews various types of existing control algorithms which have been employed for controlling operation of SAPF. Harmonic extraction, DC-link capacitor voltage regulation, current control and synchronizer algorithms are examined and discussed. The most relevant techniques which have been applied for each control algorithm are described and contrasted in an organized manner to identify their respective strengths and weaknesses. It is found that the applied control algorithms differ in two conditions: (1) the condition where harmonic current distortion is treated by the SAPF in the presence of non-ideal source voltage; and (2) the condition where multilevel inverter is employed as the circuit topology of SAPF.
Keywords: active filter; control technique; current harmonics mitigation; voltage-source inverter; distorted source voltage; power quality; reactive power compensation active filter; control technique; current harmonics mitigation; voltage-source inverter; distorted source voltage; power quality; reactive power compensation

Share and Cite

MDPI and ACS Style

Hoon, Y.; Mohd Radzi, M.A.; Hassan, M.K.; Mailah, N.F. Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review. Energies 2017, 10, 2038. https://doi.org/10.3390/en10122038

AMA Style

Hoon Y, Mohd Radzi MA, Hassan MK, Mailah NF. Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review. Energies. 2017; 10(12):2038. https://doi.org/10.3390/en10122038

Chicago/Turabian Style

Hoon, Yap, Mohd Amran Mohd Radzi, Mohd Khair Hassan, and Nashiren Farzilah Mailah. 2017. "Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review" Energies 10, no. 12: 2038. https://doi.org/10.3390/en10122038

APA Style

Hoon, Y., Mohd Radzi, M. A., Hassan, M. K., & Mailah, N. F. (2017). Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review. Energies, 10(12), 2038. https://doi.org/10.3390/en10122038

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics