Use of Double Wire Traction for Removal of Pacemaker Leads
Abstract
Case report
Discussion
Funding/potential competing interests
References
- Cabell, C.H.; Heidenreich, P.A.; Chu, V.H.; Moore, C.M.; Stryjewski, M.E.; Corey, G.R.; et al. Increasing rates of cardiac device infections among Medicare beneficiaries: 1990–1999. Am Heart J. 2004, 147, 582–586. [Google Scholar] [CrossRef] [PubMed]
- Love, C.J.; Wilkoff, B.L.; Byrd, C.L.; Belott, P.H.; Brinker, J.A.; Fearnot, N.E.; Friedman, R.A.; et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. Pacing Clin Electrophysiol. 2000, 23, 544–551. [Google Scholar] [PubMed]
- Lead Extraction 2008: Critical Review and Implementation of HRS Guidelines. In Proceedings of the HR 2008 satellite symposium co-sponsored by Cleveland Clinic and Heart Rythm Society, Course directors Bruce Wilkoff, Charles Love, Charles Byrd, San Francisco, CA, USA, 15 May 2008.
- Wilkoff, B.L.; Love, C.J.; Byrd, C.L.; Bongiorni, M.G.; Carrillo, R.G.; Crossley, G.H.; et al. Transvenous Lead Extraction: Heart Rythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management: This document was endorsed by the American Heart Association (AHA). Heart Rhythm. 2009, 6, 1058–1104. [Google Scholar] [CrossRef] [PubMed]
- Robboy, S.J.; Harthorne, J.W.; Leinbach, R.C.; Sanders, C.A.; Austen, W.G. Autopsy findings with permanent pervenous pacemakers. Circulation 1969, 39, 495–501. [Google Scholar] [CrossRef] [PubMed]
- Hauser, R.G.; Katsiyiannis, W.T.; Gornick, C.C.; Almquist, A.K.; Kallinen, L.M. Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction. Europace 2010, 12, 395–401. [Google Scholar] [CrossRef] [PubMed]
- Maytin, M.; Epstein, L.M. The challenges of transvenous lead extraction. Heart 2011, 97, 425–434. [Google Scholar] [CrossRef] [PubMed]
© 2011 by the author. Attribution - Non-Commercial - NoDerivatives 4.0.
Share and Cite
Arnold, C.; Tenkorang, J.; Schlaepfer, J.; Fromer, M. Use of Double Wire Traction for Removal of Pacemaker Leads. Cardiovasc. Med. 2011, 14, 189. https://doi.org/10.4414/cvm.2011.01599
Arnold C, Tenkorang J, Schlaepfer J, Fromer M. Use of Double Wire Traction for Removal of Pacemaker Leads. Cardiovascular Medicine. 2011; 14(6):189. https://doi.org/10.4414/cvm.2011.01599
Chicago/Turabian StyleArnold, Christine, Joanna Tenkorang, Juerg Schlaepfer, and Martin Fromer. 2011. "Use of Double Wire Traction for Removal of Pacemaker Leads" Cardiovascular Medicine 14, no. 6: 189. https://doi.org/10.4414/cvm.2011.01599
APA StyleArnold, C., Tenkorang, J., Schlaepfer, J., & Fromer, M. (2011). Use of Double Wire Traction for Removal of Pacemaker Leads. Cardiovascular Medicine, 14(6), 189. https://doi.org/10.4414/cvm.2011.01599