Next Article in Journal
Indoor Cycling Energy Expenditure: Does Sequence Matter?
Next Article in Special Issue
Study Protocol on the Validation of the Quality of Sleep Data from Xiaomi Domestic Wristbands
Previous Article in Journal
Incidence and Risk Factors of 30-Day Surgical Site Infection after Primary Total Joint Arthroplasty in a Middle-Income Country: A Single-Center Experience
Previous Article in Special Issue
Coupling Wearable Devices and Decision Theory in the United States Emergency Department Triage Process: A Narrative Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions

1
The Master Program of Long-Term Care in Aging, Kaohsiung Medical University, Kaohsiung 807378, Taiwan
2
Kaohsiung LOHAS Home Care Institution, Kaohsiung 82061, Taiwan
3
Department of Electrical Engineering, College of Engineering, Chang Gung University, Tao-Yuan 33302, Taiwan
4
Neuroscience Research Center, Chang Gung Memorial Hospital, Linkou 333423, Taiwan
5
School of Physical Therapy and Graduate Institute of Rehabilitation Science, College of Medicine, Chang Gung University, Tao-Yuan 33302, Taiwan
6
Department of Physical Therapy, College of Health Science, Kaohsiung Medical University, Kaohsiung 807378, Taiwan
7
Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung 807378, Taiwan
8
Center for Long-Term Care Research, Medical University, Kaohsiung 807378, Taiwan
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2021, 18(3), 869; https://doi.org/10.3390/ijerph18030869
Submission received: 28 November 2020 / Revised: 13 January 2021 / Accepted: 16 January 2021 / Published: 20 January 2021
(This article belongs to the Special Issue Wearable Technology and Health)

Abstract

Background: Aging may result in autonomic nervous dysfunction. Heart rate variability (HRV) is a non-invasive method to measure autonomic nervous activities. Many studies have shown that HRV contributes to the risk assessment of diseases. A Polar V800 heart rate monitor is a wearable device that measures R-R intervals, but has only been validated in younger adults under limited testing conditions. There is no validation of the V800 under mental stress or in dual task testing conditions. Therefore, this study investigated the validity of the Polar V800 heart rate monitor for assessing R-R intervals and evaluated if there were differences on HRV parameters under different situations in community-dwelling elderly adults. Methods: Forty community-dwelling elderly adults were recruited. Heart rates were recorded via electrocardiogram (ECG) and the V800 under sitting, during an arithmetic test, during a naming test, a self-selected walking velocity test (SSWV), and dual tasks (SSWV performing mental arithmetic test and SSWV performing naming test). Indices of time and frequency domains of HRV were calculated afterwards. The intra-class correlation coefficient (ICC) analysis and effect size were calculated to examine the concurrent validity between the V800 and the ECG. Results: All HRV indices from the V800 were highly correlated with the ECG under all tested conditions (ICC = 0.995–1.000, p < 0.001) and the effect size of bias was small (<0.1). Conclusion: Overall, the V800 has good validity on the assessment of HRV in community-dwelling elderly adults during sitting, mental arithmetic test, naming test, SSWV, and dual tasks.
Keywords: validity; heart rate variability; heart rate; autonomic nervous system validity; heart rate variability; heart rate; autonomic nervous system

Share and Cite

MDPI and ACS Style

Huang, C.-J.; Chan, H.-L.; Chang, Y.-J.; Chen, S.-M.; Hsu, M.-J. Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions. Int. J. Environ. Res. Public Health 2021, 18, 869. https://doi.org/10.3390/ijerph18030869

AMA Style

Huang C-J, Chan H-L, Chang Y-J, Chen S-M, Hsu M-J. Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions. International Journal of Environmental Research and Public Health. 2021; 18(3):869. https://doi.org/10.3390/ijerph18030869

Chicago/Turabian Style

Huang, Chang-Jing, Hsiao-Lung Chan, Ya-Ju Chang, Shu-Mei Chen, and Miao-Ju Hsu. 2021. "Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions" International Journal of Environmental Research and Public Health 18, no. 3: 869. https://doi.org/10.3390/ijerph18030869

APA Style

Huang, C.-J., Chan, H.-L., Chang, Y.-J., Chen, S.-M., & Hsu, M.-J. (2021). Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions. International Journal of Environmental Research and Public Health, 18(3), 869. https://doi.org/10.3390/ijerph18030869

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop