Next Article in Journal
A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients
Next Article in Special Issue
Women’s Experience of Facility-Based Childbirth Care and Receipt of an Early Postnatal Check for Herself and Her Newborn in Northwestern Tanzania
Previous Article in Journal
An Improved Empirical Model for Flood Discharge Atomization and Its Application to Optimize the Flip Bucket of the Nazixia Project
Previous Article in Special Issue
The Effect of Prenatal Stress, Proxied by Marital and Paternity Status, on the Risk of Preterm Birth
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania

1
Faculty of Health Sciences, University of Stavanger, 4036 Stavanger, Norway
2
Muhimbili National Hospital, P.O. Box 65000, Dar es Salaam, Tanzania
3
Department of Research, Stavanger University Hospital, 4011 Stavanger, Norway
4
School of Medicine, Aga Khan University, P.O. Box 38129, Dar es Salaam, Tanzania
5
Department of Paediatrics, Weill Cornell Medicine, New York, NY 10065, USA
6
Department of Anaesthesiology and Intensive Care, Stavanger University Hospital, 4011 Stavanger, Norway
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2019, 16(3), 315; https://doi.org/10.3390/ijerph16030315
Submission received: 20 November 2018 / Revised: 22 January 2019 / Accepted: 22 January 2019 / Published: 24 January 2019
(This article belongs to the Collection Women's Reproductive and Maternal Health)

Abstract

Background: Intrapartum foetal heart rate (FHR) monitoring is crucial for identification of hypoxic foetuses and subsequent interventions. We compared continuous monitoring using a novel nine-crystal FHR monitor (Moyo) versus intermittent single crystal Doppler (Doppler) for the detection of abnormal FHR. Methods: An unmasked randomised controlled study was conducted in a tertiary hospital in Tanzania (ClinicalTrials.gov Identifier: NCT02790554). A total of 2973 low-risk singleton pregnant women in the first stage of labour admitted with normal FHR were randomised to either Moyo (n = 1479) or Doppler (1494) arms. The primary outcome was the proportion of abnormal FHR detection. Secondary outcomes were time intervals in labour, delivery mode, Apgar scores, and perinatal outcomes. Results: Moyo detected abnormal FHR more often (13.3%) compared to Doppler (9.8%) (p = 0.002). Time intervals from admission to detection of abnormal FHR were 15% shorter in Moyo (p = 0.12) and from the detection of abnormal FHR to delivery was 36% longer in Moyo (p = 0.007) compared to the Doppler arm. Time from last FHR to delivery was 12% shorter with Moyo (p = 0.006) compared to Doppler. Caesarean section rates were higher with the Moyo device compared to Doppler (p = 0.001). Low Apgar scores (<7) at the 1st and 5th min were comparable between groups (p = 0.555 and p = 0.800). Perinatal outcomes (fresh stillbirths and 24-h neonatal deaths) were comparable at delivery (p = 0.497) and 24-h post-delivery (p = 0.345). Conclusions: Abnormal FHR detection rates were higher with Moyo compared to Doppler. Moyo detected abnormal FHR earlier than Doppler, but time from detection to delivery was longer. Studies powered to detect differences in perinatal outcomes with timely responses are recommended.
Keywords: foetal heart rate; Moyo; Doppler; perinatal outcomes foetal heart rate; Moyo; Doppler; perinatal outcomes

Share and Cite

MDPI and ACS Style

Kamala, B.; Kidanto, H.; Dalen, I.; Ngarina, M.; Abeid, M.; Perlman, J.; Ersdal, H. Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania. Int. J. Environ. Res. Public Health 2019, 16, 315. https://doi.org/10.3390/ijerph16030315

AMA Style

Kamala B, Kidanto H, Dalen I, Ngarina M, Abeid M, Perlman J, Ersdal H. Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania. International Journal of Environmental Research and Public Health. 2019; 16(3):315. https://doi.org/10.3390/ijerph16030315

Chicago/Turabian Style

Kamala, Benjamin, Hussein Kidanto, Ingvild Dalen, Matilda Ngarina, Muzdalifat Abeid, Jeffrey Perlman, and Hege Ersdal. 2019. "Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania" International Journal of Environmental Research and Public Health 16, no. 3: 315. https://doi.org/10.3390/ijerph16030315

APA Style

Kamala, B., Kidanto, H., Dalen, I., Ngarina, M., Abeid, M., Perlman, J., & Ersdal, H. (2019). Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania. International Journal of Environmental Research and Public Health, 16(3), 315. https://doi.org/10.3390/ijerph16030315

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop