A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors

1
Chair of Electronics and Medical Signal Processing, TU Berlin, 10623 Berlin, Germany
2
Staedtisches Klinikum Dresden-Neustadt, 01159 Dresden, Germany
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Academic Editor: Vittorio M. N. Passaro
Sensors 2017, 17(1), 158; https://doi.org/10.3390/s17010158
Received: 9 November 2016 / Revised: 7 January 2017 / Accepted: 9 January 2017 / Published: 14 January 2017
(This article belongs to the Special Issue Wearable Biomedical Sensors)
Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations’ vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway. View Full-Text
Keywords: ectopic beat detection; pulse wave velocity; blood pressure estimation; pulse arrival time, multimodal signal processing; wearable sensor network ectopic beat detection; pulse wave velocity; blood pressure estimation; pulse arrival time, multimodal signal processing; wearable sensor network
Show Figures

Figure 1

MDPI and ACS Style

Pflugradt, M.; Geissdoerfer, K.; Goernig, M.; Orglmeister, R. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors. Sensors 2017, 17, 158.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop