An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments

1
Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Tai Yuan 030051, China
2
Science and Technology on Electronic Test & Measurement Laboratory, North University of China, Tai Yuan 030051
*
Authors to whom correspondence should be addressed.
Sensors 2015, 15(9), 21844-21856; https://doi.org/10.3390/s150921844
Submission received: 8 June 2015 / Revised: 17 August 2015 / Accepted: 24 August 2015 / Published: 31 August 2015
(This article belongs to the Section Physical Sensors)

Abstract

:
Pressure measurements in high-temperature applications, including compressors, turbines, and others, have become increasingly critical. This paper proposes an implantable passive LC pressure sensor based on an alumina ceramic material for in situ pressure sensing in high-temperature environments. The inductance and capacitance elements of the sensor were designed independently and separated by a thermally insulating material, which is conducive to reducing the influence of the temperature on the inductance element and improving the quality factor of the sensor. In addition, the sensor was fabricated using thick film integrated technology from high-temperature materials that ensure stable operation of the sensor in high-temperature environments. Experimental results showed that the sensor accurately monitored pressures from 0 bar to 2 bar at temperatures up to 800 °C. The sensitivity, linearity, repeatability error, and hysteretic error of the sensor were 0.225 MHz/bar, 95.3%, 5.5%, and 6.2%, respectively.

1. Introduction

There is a growing demand for measurement of pressure in harsh environments, especially in high-temperature environments, such as are found in automotive, turbine, aerospace, and industrial applications [1,2,3,4]. For example, the air-pressure monitoring and control for the combustor of the turbine engine can help to reduce the risk of stall, and this requires a pressure sensor that can operate above 600 °C for in situ pressure measurement. Therefore, research on pressure sensors that can perform reliably in high-temperature environments has become increasingly important. Traditional pressure sensors are based on silicon or silicon-on-insulator materials, and they do not function in high-temperature environments because the electric wire and pressure sensitive structure impair functionality at temperatures above 300 °C [5,6,7,8]. Although silicon carbide and gallium nitride materials permit pressure measurements in moderately high-temperature environments, pressure sensors capable of operation at temperatures above 600 °C have yet to be reported [9,10]. Furthermore, most high-temperature pressure sensors require a battery power supply, which increased the complexity of the sensor. Passive wireless sensors have characteristics of having no batteries and contactless signal readout, which have extensive application prospects and can conduct in situ measurement in many fields, such as hermetic space, humidity monitoring, and high-temperature measurement.
Some wireless passive LC sensors using low-temperature co-fired ceramic (LTCC) or high-temperature co-fired ceramic (HTCC) technology have been developed to conduct in situ pressure, temperature, and other parameter measurements in high-temperature environments. The properties of these ceramic materials are able to ensure stable operation of the sensor in high-temperature environments, and their resonant signals can be read wirelessly through the magnetic coupling between the passive sensors and reader antennae. However, higher temperatures greatly influence these ceramic pressure sensors, especially their inductance coils, producing greater resistance in the sensors and a lower quality factor. Since the quality factor of a passive LC sensor describes the relationship between energy storage and energy consumption, a higher quality factor is beneficial for the acquisition of power via inductive coupling, as well as for transmitting data to an external receiver. Because of the lower quality factor of the LTCC and HTCC sensors in high-temperature environments, the coupling strength is very weak between the sensor and antenna, impeding wireless signal transmission and precluding precise detection of pressure signals. Moreover, the LTCC material cannot be utilized at temperatures over 600 °C, and the LTCC sensor cannot operate at temperatures above 600 °C. For example, in 2002, the Georgia Institute of Technology first proposed a wireless passive LTCC high-temperature pressure sensor that demonstrated a sensitivity of up to 150 kHz/bar; however, the sensor could only operate at temperatures up to 450 °C [11,12]. Subsequently, Radosavljevic and Xiong et al. proposed improved LTCC high-temperature pressure sensors that showed significant improvement in sensitivity and pressure testing range, respectively; however, the operating temperatures could not exceed 600 °C [13,14,15,16]. In 2013, some HTCC high-temperature pressure sensor were proposed, in which the material withstood temperatures exceeding 800 °C, with a coupling distance of up to 2.8 cm; however, the sensors can only be tested below 600 °C [17,18,19]. In 2014, Li and Zhang proposed an integrated LC ceramic pressure sensor respectively, which can be tested up to 800 °C, but higher temperature greatly influence the inductance of the LC sensor, producing a lower quality factor and imprecise measurements results [20,21]. Recently, Boccard et al. proposed a new approach to measure temperature in the far-field region using a dielectric resonator, which the operated temperature can be up to 700 °C, and the working distance can be up to 1.06 m. However, the pressure sensors based on this concept for high temperature application have not been reported yet [22].
This paper presents a wireless passive LC pressure sensor based on an alumina ceramic. The inductance and capacitance elements of the sensor were designed separately, and then independently integrated on two ceramic substrates using thick film integrated technology, which can produce a sensor operational in high-temperature environments with a high quality factor. The sensor was then tested in a high-temperature pressure system, and the accuracy of the pressure characterization of the sensor in high-temperature environments was investigated.

2. Measurement Principle and Design of the Sensor

Figure 1 presents the proposed high-temperature pressure monitoring method in a practical application. In a working engine, the sensor would be embedded in the engine surface, with the capacitance element of the sensor internal to the engine, conducting in situ real-time pressure monitoring, and the inductance element of the sensor is external to the engine, magnetically coupled with the readout/storage electronics to facilitate pressure signal data collection and storage. The sensor consists of an inductance coil and a capacitance plate, which form a series LC resonant circuit. The resonant frequency f0 and quality factor Q of the sensor are expressed as follows:
f 0 = 1 / ( 2 π L S C S )
Q = ( 1 / R s ) ( L s / C s )
where Ls, Cs, and Rs are the inductance, capacitance, and resistance of the sensor, respectively.
Figure 1. Proposed high-temperature pressure monitoring method in a practical application.
Figure 1. Proposed high-temperature pressure monitoring method in a practical application.
Sensors 15 21844 g001
The pressure can be wirelessly detected by measuring the change in the sensor’s resonant frequency, according to the measurement principle shown in Figure 2a, in which Lp and Rp are the inductance and resistance of the reader antenna, respectively.
Figure 2. (a) Wireless measurement principle; (b) Equivalent electric circuit.
Figure 2. (a) Wireless measurement principle; (b) Equivalent electric circuit.
Sensors 15 21844 g002
Figure 2 shows the equivalent circuit of the input impedance as viewed from the reader antenna, the parameters Rp and Lp represent inductance and resistance of the reader antenna, k is the coupling coefficient between the sensor and the reader antenna, and the parameters Rs, Ls and Cs represent inductance, resistance and capacitance of the sensor. In addition, w and Zs are the angular frequency and impedance of the sensor. According to Kirchhoff's law and the theory underlying transformer operation, the equivalent impedance Zeq of the sensor is defined as [23,24,25]:
Z e q = R p + j 2 π f 0 L p [ 1 + k 2 ( f / f 0 ) 1 ( f / f 0 ) 2 + j f / ( f 0 Q ) ] = F ( f 0 )
where f is the excitation frequency of the reader antenna. From Equation (3), the input impedance phase Im(Z) can be expressed as follows:
I m ( Z ) = 2 π f L p [ 1 ( f 0 / f ) 2 + k 2 Q 2 1 ( f / f 0 ) 2 1 + Q 2 ( f / f 0 f 0 / f ) 2 ]
When a bandwidth frequency sweep signal is loaded on the reader antenna, and a certain frequency of the sweep is approximately equal to the resonant frequency of the sensor f0, the passive sensor is excited at resonance, and the impedance phase will produce a significant change in the input impedance phase. From Equation (4), we can conclude that the input impedance phase Im(Z) is a function of the resonant frequency of the sensor, and thus the resonant frequency of the sensor can be detected accurately by monitoring the change of the impedance phase Im(Z). Furthermore, the pressure characterization of the sensor can then be obtained indirectly by analyzing the variation in the sensor’s resonant frequency f0 in high-temperature environments.
From Equation (2), we can conclude that at increasing temperatures, increasing resistance in the inductance coil will induce a significant decrease in the quality factor, which is not conducive to signal transmission in high-temperature environments. However, if the inductance and capacitance elements of the sensor are separated by a thermal insulation material, the inductance and capacitance elements operate in room-temperature environments and high-temperature environments, respectively. In addition, when the sensor insert in high temperature environments for pressure measurement, the inductance coil of the sensor will have little effect on the quality factor of the sensor. Figure 3a,b show designs of the inductance and capacitance elements, respectively, each containing of three layers of alumina ceramic tapes; these inductance and capacitance elements can be connected with silver (Ag) wire to form a passive series LC sensor.
Figure 3. Design schematic of the (a) inductance and (b) capacitance elements of the sensor.
Figure 3. Design schematic of the (a) inductance and (b) capacitance elements of the sensor.
Sensors 15 21844 g003
The inductance design includes a square spiral inductor, the dimensions of which can be calculated as follows [26]:
L s = 0.00000296 n 2 ( d o u t + d i n 2 ) 1 + 2.75 ( d o u t d i n d o u t + d i n )
where n is the number of inductor coils, din is the inner diameter of the inductor coil, and dout is the outer diameter of the inductor coil. The square plate of the capacitance element can be calculated as follows:
C s = ε 0 a 2 t g + ( 2 t m / ε r ) tanh 1 ( d 0 / ( t g + ( 2 t m / ε r ) ) ) d 0 / ( t g + ( 2 t m / ε r ) )
d 0 = 3 P a 4 ( 1 v 2 ) 16 E ( t m ) 3
where ε0 is the vacuum dielectric constant, εr is the relative permittivity of the alumina ceramic material, tg is the height of the embedded cavity, tm is the thickness of the sensitive membrane, E is Young’s modulus, v is Poisson’s ratio, P is the atmospheric pressure outside the sensor, and a is the side length of the capacitance plate. The specific LC structure design parameters are shown in Table 1.
Table 1. Geometric structural parameters of the sensor.
Table 1. Geometric structural parameters of the sensor.
SymbolParametersValue
dinInner diameter of the spiral inductor~8 mm
doutOuter diameter of the spiral inductor~50 mm
nNumber of turns of the inductor coil10
aSide length of the capacitance plate~12 mm
tgHeight of the sealed cavity200 µm

3. Fabrication Procedure

Alumina green tapes, Ag wire, and conductive Ag ink were used to fabricate the sensor. In addition, the melting temperature of Ag is above 960 °C, which ensure the feasibility of the sensor in high temperature environments. The sensor was monolithically fabricated, as depicted in Figure 4, which included cutting, drilling, filling, laminating, hot-pressing, high-temperature sintering, screen-printing, low-temperature sintering, and packaging, and associated processing steps. The inductance and capacitance structures each consist of three layers of alumina green tapes, which were placed in a drying oven at 80 °C for 30 min. In the inductance element, Layer 2 was the same as Layer 1. In the capacitance element, Layer 2 was cut using the NDYAG micromachining laser system to produce with accuracy a cavity matching the designed punch file. A carbon film was then manufactured with the same punch file used to produce the diaphragm of the chamber, and the chamber was lined with the carbon film, which would volatilize to form a sealed cavity during co-firing. In the conductance and inductance elements, Layer 3 consisted of one sheet of ceramic green tape, in which two channels were cut using a different punch file. In both elements, all three layers were stacked together under specific temperature and pressure conditions, bonding them tightly to form the two ceramic substrates. These stacks were sintered in a box furnace to cure the ceramic substrates; the specific sintering curve is shown in Figure 5a. After firing, the respective plate and coil of the capacitance and inductance elements were fabricated using screen-printing technology, and then the Ag wire was placed in the channels in the ceramic substrates to establish connections between the two elements. The connected ceramic substrates were then sintered in a furnace at a peak temperature of 875 °C and a total firing time of approximately 80 min to allow the Ag ink to cure, forming an LC sensor. The sintering curve for this step is shown in Figure 5b. After the low-temperature sintering, the sensor was integrated on a thermally insulating structure that separated the two elements by a certain distance, to allow the capacitance and inductance elements to operate in high-temperature environments and room-temperature environments, respectively. A digital image of the final fabricated ceramic sensor sample is shown in Figure 6.
Figure 4. Fabrication process.
Figure 4. Fabrication process.
Sensors 15 21844 g004
Figure 5. Sintering curve for the curing process of (a) the alumina ceramic substrates and (b) the electrical elements.
Figure 5. Sintering curve for the curing process of (a) the alumina ceramic substrates and (b) the electrical elements.
Sensors 15 21844 g005
Figure 6. Image of the (a) inductance and (b) capacitance of the sensor sample.
Figure 6. Image of the (a) inductance and (b) capacitance of the sensor sample.
Sensors 15 21844 g006

4. Experimental Procedure and Results

The testing antenna was fabricated of copper, which has excellent mechanical properties and electrical performance. As shown in Figure 7, the antenna’s outer diameter was 31.6 mm, and it contained 5.5 turns at an average distance from one another of 5.45 mm. The self-resonant frequency of the antenna was approximately 61.3 MHz, and the input impedance phase can be read in an effective bandwidth range between 1 MHz and 61.3 MHz.
Figure 7. Reader antenna.
Figure 7. Reader antenna.
Sensors 15 21844 g007
To investigate the pressure characterization of the fabricated sensor in high-temperature environments, the sensor’s performance was measured as a function of temperature and pressure using a high-temperature pressure measurement system, consisting of an E4991A impedance analyzer, a high-temperature pressure tank, and a temperature pressure control instrument, as shown in Figure 8. The temperature pressure control instrument allows accurate control of temperatures from room-temperature to 800 °C and pressures from 0 bar to 2 bar. When the sensor is placed in the system’s high-temperature pressure tank, the capacitance element of the sensor can operate up to 800 °C for in situ pressure monitoring, and the inductance element of the sensor operates below 200 °C for pressure signal output. Ultimately, the in situ pressure signal in the high-temperature pressure tank was captured wirelessly by the E4991A impedance analyzer through the reader antenna coupled with the sensor. A set of high-temperature pressure experiments on the sensor in the high-temperature pressure testing tank were carried out by varying the temperature and pressure to investigate the sensor’s high-temperature response. The resonant frequency and quality factor of the sensor as a function of temperature are shown in Figure 9.
Figure 8. High-temperature pressure measurement system.
Figure 8. High-temperature pressure measurement system.
Sensors 15 21844 g008
Figure 9. Resonant frequency f0 and quality factor Q of the sensor as a function of temperature.
Figure 9. Resonant frequency f0 and quality factor Q of the sensor as a function of temperature.
Sensors 15 21844 g009
Figure 9 shows that the resonant frequency of the sensor at room-temperature was approximately 26.95 MHz, its resonant frequency at 800 °C was 26.75 MHz, and the average slope of the resonant frequency from room-temperature to 800 °C was approximately −0.25 kHz·°C−1. The quality factor of the sensor reduced from 110 at room-temperature to 68 at 800 °C, the change is smaller than the sensor proposed by Zhang in 2014 [21].
Figure 10 shows the resonant frequencies of the sensor when different pressures were applied to it at elevated temperatures, indicating that as pressure increased the resonant frequency decreased linearly in elevated temperature environments. Furthermore, the sensitivity of the sensor increased as the temperature increased, from 0.11 MHz/bar at room-temperature to 0.225 MHz/bar at 800 °C.
Figure 10. Resonant frequencies of the sensor as a function of pressure at varying temperatures.
Figure 10. Resonant frequencies of the sensor as a function of pressure at varying temperatures.
Sensors 15 21844 g010
Figure 11 shows the sensor’s impedance phase and magnitude as a function of pressure at 800 °C. Figure 11 demonstrates effective coupling between the sensor and reader antenna at 800 °C, and the resonant frequency of the sensor can be obtained from the phase minimum of each curve. Many repetitions of pressure experiments at 800 °C were carried out to investigate the pressure characterization of the sensor at 800 °C, and the specific test results are shown in Figure 12.
Figure 11. Impedance (a) phase and (b) magnitude, in response to different pressures at 800 °C.
Figure 11. Impedance (a) phase and (b) magnitude, in response to different pressures at 800 °C.
Sensors 15 21844 g011
Figure 12. The resonant frequency of the sensor as a function of pressure at 800 °C.
Figure 12. The resonant frequency of the sensor as a function of pressure at 800 °C.
Sensors 15 21844 g012
From Figure 12, we can see that the linearity, repeatability error, and hysteretic error of the sensor were 95.3%, 5.5%, and 6.2%, respectively, as a function of pressure at 800 °C. Curve fitting produces a frequency-pressure relationship of the sensor at 800 °C that can be expressed as F (MHz) = 26.75–0.225 P (bar). Therefore, the pressure sensitivity of the sensor at 800 °C is approximately 0.225 MHz/bar.

5. Conclusions

This work successfully demonstrates a design and fabrication method for an implantable high-temperature passive LC ceramic pressure sensor operable at temperatures up to 800 °C. The inductance and capacitance elements of the sensor were designed separately and installed at a distance from one another, separated by a thermally insulating material, allowing the sensor to operate in high-temperature environments with a high quality factor. The sensor was fabricated using thick film integrated technology based on alumina ceramic material, further ensuring operational stability in high-temperature environments. The sensor was evaluated in a high-temperature pressure testing system, and the experimental results showed that the sensor is capable of conducting pressure measurements from 0 bar to 2 bar at temperatures up to 800 °C, with a sensitivity, linearity, repeatability error, and hysteretic error of 0.225 MHz/bar, 95.3%, 5.5%, and 6.2%, respectively. The pressure range for the turbine engine application is above 1 Mpa, which the sensor is far from meeting the requirements. Future work will be focused on improving the pressure range of the sensor for practical application.

Acknowledgments

This work was supported by the National Science Fund for Distinguished Young Scholars (No. 51425505), the National Natural Science Foundation of China (No. 61471324) and the Program for the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi, Research Project Supported by Shanxi Scholarship Council of China (2013-077).

Author Contributions

All works with relation to this paper have been accomplished by all authors’ efforts. The idea and design of the sensor were proposed by Jijun Xiong and Chen Li. Pinggang Jia and Xiaoyong Chen designed the fabrication method of the sensor. Wendong Zhang, Jun Liu and Chenyang Xue gave significant guidance on the experiments. At last, every segment relate to this paper is accomplished under the guidance from Qiulin Tan.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Johnson, R.W.; Evans, J.L.; Jacobsen, P.; Thompson, J.R.; Christopher, M. The changing automotive environment: High-temperature electronics. IEEE Trans. Electron. Packag. Manuf. 2004, 27, 164–176. [Google Scholar] [CrossRef]
  2. Boyce, M.P. Gas Tubine Engineering Handbook, 3rd ed.; Gulf Professional Publishing: Burlington, MA, USA, 2006. [Google Scholar]
  3. William, C.W.; Gary, G.M. Passive wireless sensor application for NASA’s extreme aeronutical environments. IEEE Sens. J. 2014, 14, 3745–3753. [Google Scholar]
  4. George, T.; Son, K.A.; Powers, R.A.; Del Castillo, L.Y.; Okojie, R. Harsh environment microtechnologies for NASA and terrestrial applications. In Proceedings of the IEEE Sensors, Irvine, CA, USA, 30 October–3 November 2005; pp. 1253–1258.
  5. Li, X.; Liu, Q.; Pang, S.; Xu, K.; Tang, H.; Sun, C. High-temperature piezoresistive pressure sensor based on implantation of oxygen into silicon wafer. Sens. Actuator A Phys. 2012, 179, 277–282. [Google Scholar] [CrossRef]
  6. San, H.; Li, Y.; Song, Z.; Yu, Y.; Chen, X. Self-packaging fabrication of silicon–glass-based piezoresistive pressure sensor. IEEE Electron Device Lett. 2013, 34, 789–791. [Google Scholar] [CrossRef]
  7. Liu, Q.; Du, L.; Zhao, Z.; Xiao, L.; Sun, X. Localized Si–Au eutectic bonding around sunken pad for fabrication of a capacitive absolute pressure sensor. Sens. Actuator A Phys. 2013, 201, 241–245. [Google Scholar] [CrossRef]
  8. San, H.; Zhang, H.; Zhang, Q.; Yu, Y.; Chen, X. Silicon–glass-based single piezoresistive pressure sensors for harsh environment applications. J. Micromech Microeng. 2013, 23, 075020. [Google Scholar] [CrossRef]
  9. Yang, J. A silicon carbide wireless temperature sensing system for high temperature applications. Sensors 2013, 13, 1884–1901. [Google Scholar] [CrossRef] [PubMed]
  10. Herfurth, P.; Maier, D.; Lugani, L.; Carlin, J.F.; Rosch, R.; Men, Y.; Grandjean, N.; Kohn, E. Ultrathin body InAlN/GaN HEMTs for high-temperature (600 °C) electronics. IEEE Electron Device Lett. 2013, 34, 496–498. [Google Scholar] [CrossRef]
  11. Fonseca, M.A.; English, J.M.; Arx, M.; Allen, M.G. Wireless micromachined ceramic pressure sensor for high-temperature applications. J. Microelectromech. Syst. 2002, 11, 337–343. [Google Scholar] [CrossRef]
  12. Fonseca, M.A. Polymer/Ceramic Wireless MEMS Pressure Sensors for Harsh Environments: High Temperature and Biomedical Applications. Ph.D. Thesis, Georgia Institute of Technology, Atalanta, GA, USA, 2007. [Google Scholar]
  13. Radosavljevic, G.; Zivanov, L.J.; Smetana, W.; Maric, A.; Unger, M.; Nad, L. A wireless embedded resonant pressure sensor fabricated in the standard LTCC technology. IEEE Sens. J. 2009, 9, 1956–1962. [Google Scholar] [CrossRef]
  14. Radosavljevic, G.; Smetana, W.; Mari, A.; Zivanov, L.J.; Unger, M.; Stojanovi, G. Microforce sensor fabricated in the LTCC technology. In Proceedings of the 27th International Conference on Microelectronics (MIEL 2010), Nis, Serbia, 16–19 May 2010; pp. 16–19.
  15. Xiong, J.; Li, Y.; Hong, Y.; Zhang, B.; Cui, T.; Tan, Q.; Zheng, S.; Liang, T. Wireless LTCC-based capacitive pressure sensor for harsh environment. Sens. Actuator A. Phys. 2013, 197, 30–37. [Google Scholar] [CrossRef]
  16. Tan, Q.; Luo, T.; Xiong, J.; Kang, H.; Ji, X.; Zhang, Y.; Yang, M.; Wang, X.; Xue, C.; Liu, J.; et al. A harsh environment-oriented wireless passive temperature sensor realized by LTCC technology. Sensors 2014, 14, 4154–4166. [Google Scholar] [CrossRef] [PubMed]
  17. Li, C.; Tan, Q.; Xue, C.; Zhang, W.; Li, Y.; Xiong, J. A high-performance LC wireless passive pressure sensor fabricated using Low-Temperature Co-Fired Ceramic (LTCC) technology. Sensors 2014, 14, 23337–23347. [Google Scholar] [CrossRef] [PubMed]
  18. Xiong, J.; Zheng, S.; Hong, Y.; Li, J.; Wang, Y.; Wang, W.; Tan, Q. Measurement of wireless pressure sensors fabricated in high temperature co-fired ceramic MEMS technology. J. Zhejiang Univ. Sci. C 2013, 14, 258–263. [Google Scholar] [CrossRef]
  19. Tan, Q.; Kang, H.; Xiong, J.; Qin, L.; Zhang, W.; Li, C.; Ding, L.; Zhang, X.; Yang, M. A wireless passive pressure micro-sensor fabricated in HTCC MEMS technology for harsh environments. Sensors 2013, 13, 9896–9908. [Google Scholar] [CrossRef] [PubMed]
  20. Li, C.; Tan, Q.; Xiong, J.; Jia, P.; Hong, Y.; Ren, Z.; Luo, T.; Liu, J.; Xue, C.; Zhang, W. A noncontact wireless passive radio frequency (RF) resonant pressure sensor with optimized design for applications in high-temperature environment. Meas. Sci. Technol. 2014, 25, 0957–0233. [Google Scholar] [CrossRef]
  21. Zhang, H.; Hong, Y.; Liang, T.; Zhang, H.; Tan, Q.; Xue, C.; Liu, J.; Zhang, W.; Xiong, J. Phase interrogation used for a wireless passive pressure sensor in an 800 °C high-temperature environment. Sensors 2015, 15, 2548–2564. [Google Scholar] [CrossRef] [PubMed]
  22. Boccard, J.; Aftab, T.; Hoppe, J.; Yousaf, A.; Hutter, R.; Reindl, L. Far-field passive temperature sensing up to 700 °C using a dielectric resonator. In Proceedings of the IEEE International Conference on Wireless for Space and Extreme Environments (WiSEE), Noordwijk, Holland, 30–31 October 2014; pp. 1–5.
  23. Nopper, R.; Niekrawietz, R.; Teindl, L. Wireless readout of passive LC sensors. IEEE Trans. Instrum. Meas. 2010, 59, 2450–2457. [Google Scholar] [CrossRef]
  24. Chen, P.J.; Rodger, D.C.; Saati, S.; Humayun, M.S.; Tai, Y.C. Microfabricated implantable Parylene-based wireless passive intraocular pressure sensors. J. Microelectromech. Syst. 2008, 17, 1342–1351. [Google Scholar] [CrossRef]
  25. Chen, P.J.; Saati, S.; Varma, R.; Humayun, M.S.; Tai, Y.C. Wireless intraocular pressure sensing using microfabricated minimally invasive flexible-coiled LC sensor implant. J. Microelectromech. Syst. 2010, 19, 721–734. [Google Scholar] [CrossRef]
  26. Mohan, S.S.; Hershenson, M.; Boyd, S.P.; Lee, T.H. Simple accurate expressions for planar spiral inductances. IEEE J. Solid-State Circuits 1999, 34, 1419–1424. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Xiong, J.; Li, C.; Jia, P.; Chen, X.; Zhang, W.; Liu, J.; Xue, C.; Tan, Q. An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments. Sensors 2015, 15, 21844-21856. https://doi.org/10.3390/s150921844

AMA Style

Xiong J, Li C, Jia P, Chen X, Zhang W, Liu J, Xue C, Tan Q. An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments. Sensors. 2015; 15(9):21844-21856. https://doi.org/10.3390/s150921844

Chicago/Turabian Style

Xiong, Jijun, Chen Li, Pinggang Jia, Xiaoyong Chen, Wendong Zhang, Jun Liu, Chenyang Xue, and Qiulin Tan. 2015. "An Insertable Passive LC Pressure Sensor Based on an Alumina Ceramic for In Situ Pressure Sensing in High-Temperature Environments" Sensors 15, no. 9: 21844-21856. https://doi.org/10.3390/s150921844

Article Metrics