Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = wood truss joist floor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 7978 KiB  
Article
Experimental Study and Numerical Simulation Analysis on Vertical Vibration Performances of 12 m Span Wood Truss Joist Floors
by Zhanyi Zhang, Shuangyong Wang, Hao Deng and Haibin Zhou
Buildings 2022, 12(9), 1455; https://doi.org/10.3390/buildings12091455 - 15 Sep 2022
Cited by 1 | Viewed by 2037
Abstract
Walking-induced vibration control in wood floors is a critical issue attracting the attention of many researchers and engineers. This paper presents an experimental study applying static deflection tests, modal tests, and pedestrian load tests to a series of full-scale 12 m span tooth [...] Read more.
Walking-induced vibration control in wood floors is a critical issue attracting the attention of many researchers and engineers. This paper presents an experimental study applying static deflection tests, modal tests, and pedestrian load tests to a series of full-scale 12 m span tooth plates connected to wood truss joist floors with strongbacks and partition walls. A comparison of the calculation error of vibration parameters between the theoretical formula and a numerical model was also conducted. The results show that strongbacks and partition walls effectively reduce both the vertical displacement and the root means acceleration at the center of the floor under pedestrian load but increases the natural frequency. The partition wall can achieve a better vibration-reduction effect than strongbacks. The error of the finite element model is higher than that of the theoretical formula. Using the theoretical formula in engineering wood floor design is recommended. Full article
(This article belongs to the Special Issue Structural Vibration Serviceability and Human Comfort)
Show Figures

Figure 1

21 pages, 57861 KiB  
Article
Experimental Investigations and Numerical Simulations of the Vibrational Performance of Wood Truss Joist Floors with Strongbacks
by Yinlan Shen, Haibin Zhou, Shuo Xue, Xingchen Yan, Jiahao Si and Cheng Guan
Forests 2021, 12(11), 1493; https://doi.org/10.3390/f12111493 - 29 Oct 2021
Cited by 1 | Viewed by 2527
Abstract
This paper provides an experimental study and computer modeling analysis of vibration performance of full-scale wood truss joist floors, related to the static deflection and vibration mode/frequency and single-person-induced vibration. The vibration behavior of full-scale truss joist floors was investigated and the influences [...] Read more.
This paper provides an experimental study and computer modeling analysis of vibration performance of full-scale wood truss joist floors, related to the static deflection and vibration mode/frequency and single-person-induced vibration. The vibration behavior of full-scale truss joist floors was investigated and the influences of the strongbacks on the vibration behavior were assessed. The results showed that the simulated predictions agreed well with the measured results. Strongbacks do not significantly affect the fundamental frequency of the truss joist floors but influence the second and third modal frequencies. The use of strongback rows at mid-span effectively decreased the maximum deformation of point loading at floor center. The effect of adding strongbacks at one-third of each span on decreasing maximum deformation at the floor center was minimal. The case of walking parallel to the joist produced higher acceleration response at the floor center than that of walking perpendicular to the joist. The closer the placements of strongbacks were to the mid-span, the more significant reduction of the vibration at floor center was. Two strongback rows at mid-span performed the best effect on reduction of vibration response at floor center. However, the use of strongbacks had limits of reduction peak acceleration of the sheathing between the joists. The study provides a valuable guide for future vibration serviceability study and design optimization of wood truss joist floors. Full article
(This article belongs to the Special Issue Application of Wood in Construction)
Show Figures

Figure 1

Back to TopTop