Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = unipolar electrical stress

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
9 pages, 4960 KiB  
Article
The Switching Characteristics in Bilayer ZnO/HfO2 Resistive Random-Access Memory, Depending on the Top Electrode
by So-Yeon Kwon, Woon-San Ko, Jun-Ho Byun, Do-Yeon Lee, Hi-Deok Lee and Ga-Won Lee
Electron. Mater. 2024, 5(2), 71-79; https://doi.org/10.3390/electronicmat5020006 - 6 Jun 2024
Cited by 1 | Viewed by 1824
Abstract
In this study, the bipolar switching behaviors in ZnO/HfO2 bilayer resistive random-access memory (RRAM), depending on different metal top electrodes (TE), are analyzed. For this purpose, devices with two types of TE–TiN/Ti and Pd, which have varying oxygen affinities, are fabricated. X-ray [...] Read more.
In this study, the bipolar switching behaviors in ZnO/HfO2 bilayer resistive random-access memory (RRAM), depending on different metal top electrodes (TE), are analyzed. For this purpose, devices with two types of TE–TiN/Ti and Pd, which have varying oxygen affinities, are fabricated. X-ray diffraction (XRD) analysis shows that ZnO has a hexagonal wurtzite structure, and HfO2 exhibits both monoclinic and orthorhombic phases. The average grain sizes are 10.9 nm for ZnO and 1.55 nm for HfO2. In regards to the electrical characteristics, the I–V curve, cycling test, and voltage stress are measured. The measurement results indicate that devices with TiN/Ti TE exhibit lower set and higher reset voltage and stable bipolar switching behavior. However, a device with Pd TE demonstrates higher set and lower reset voltage. This phenomenon can be explained by the Gibbs free energy of formation (∆Gf°). Additionally, the Pd TE device shows unstable bipolar switching characteristics, where unipolar switching occurs simultaneously during the cycling test. This instability in devices with Pd TE could potentially lead to soft errors in operation. For guaranteeing stable bipolar switching, the oxygen affinity of material for TE should be considered in regards to ZnO/HfO2 bilayer RRAM. Full article
Show Figures

Figure 1

19 pages, 1193 KiB  
Review
Efficacy and Safety of Transcranial Electric Stimulation during the Perinatal Period: A Systematic Literature Review and Three Case Reports
by Andrew Laurin, Noémie Nard, Marine Dalmont, Samuel Bulteau, Cloé Bénard, Olivier Bonnot, Norbert Winer, Françoise Dupont, Gisèle Apter, Frédérique Terranova-Commessie, Olivier Guillin, Wissam El-Hage, Anne Sauvaget and Maud Rothärmel
J. Clin. Med. 2022, 11(14), 4048; https://doi.org/10.3390/jcm11144048 - 13 Jul 2022
Cited by 10 | Viewed by 3961
Abstract
Introduction: The perinatal period is an at-risk period for the emergence or decompensation of psychiatric disorders. Transcranial electrical stimulation (tES) is an effective and safe treatment for many psychiatric disorders. Given the reluctance to use pharmacological treatments during pregnancy or breastfeeding, tES [...] Read more.
Introduction: The perinatal period is an at-risk period for the emergence or decompensation of psychiatric disorders. Transcranial electrical stimulation (tES) is an effective and safe treatment for many psychiatric disorders. Given the reluctance to use pharmacological treatments during pregnancy or breastfeeding, tES may be an interesting treatment to consider. Our study aims to evaluate the efficacy and safety of tES in the perinatal period through a systematic literature review followed by three original case reports. Method: Following PRISMA guidelines, a systematic review of MEDLINE and ScienceDirect was undertaken to identify studies on tES on women during the perinatal period. The initial research was conducted until 31 December 2021 and search terms included: tDCS, transcranial direct current stimulation, tACS, transcranial alternating current stimulation, tRNS, transcranial random noise stimulation, pregnancy, perinatal, postnatal, and postpartum. Results: Seven studies reporting on 33 women during the perinatal period met the eligibility criteria. No serious adverse effects for the mother or child were reported. Data were limited to the use of tES during pregnancy in patients with schizophrenia or unipolar depression. In addition, we reported three original case reports illustrating the efficacy and safety of tDCS: in a pregnant woman with bipolar depression, in a pregnant woman with post-traumatic stress disorder (sham tDCS), and in a breastfeeding woman with postpartum depression. Conclusions: The results are encouraging, making tES a potentially safe and effective treatment in the perinatal period. Larger studies are needed to confirm these initial results, and any adverse effects on the mother or child should be reported. In addition, research perspectives on the medico-economic benefits of tES, and its realization at home, are to be investigated in the future. Full article
Show Figures

Figure 1

23 pages, 8820 KiB  
Article
The Effect of DC Voltage Pre-Stress on the Breakdown Voltage of Air under Composite DC and LI Voltage and Test Circuit: Design and Application
by Mehmet Murat Ispirli, Özcan Kalenderli, Florian Seifert, Michael Rock and Bülent Oral
Energies 2022, 15(4), 1353; https://doi.org/10.3390/en15041353 - 13 Feb 2022
Cited by 2 | Viewed by 3140
Abstract
The use of HVDC systems is increasing in number due to technological innovations, increasing power capacity and increasing customer demand. The characteristics of insulation systems under composite DC and LI voltage must be examined and clarified. In this study, firstly, experimental circuits were [...] Read more.
The use of HVDC systems is increasing in number due to technological innovations, increasing power capacity and increasing customer demand. The characteristics of insulation systems under composite DC and LI voltage must be examined and clarified. In this study, firstly, experimental circuits were designed to generate and measure composite DC and LI high voltage using a simulation program. The coupling elements used were chosen according to simulation results. Afterward, experimental circuits were established in the laboratory according to the simulation results of the designed experimental circuit. Then, breakdown voltages under composite DC and LI voltage for less uniform and non-uniform electric fields were measured with four different electrode systems for positive and negative DC voltage pre-stresses with different amplitudes. The 50% breakdown voltage was calculated using the least-squares method. Finally, 3D models were created for the electrode systems used in the experiments using the finite element method. The efficiency factors of electrode systems calculated with the FEM results were correlated with the experimental breakdown voltage results. Thus, the breakdown behavior of air under bipolar and unipolar composite voltages (CV) was investigated. In conclusion, the experimental results showed that very fast polarity change in bipolar CV causes higher electrical stress compared to unipolar CV. Full article
(This article belongs to the Section F6: High Voltage)
Show Figures

Figure 1

13 pages, 5430 KiB  
Article
Frequency and Temperature-Dependent Space Charge Characteristics of a Solid Polymer under Unipolar Electrical Stresses of Different Waveforms
by Hanwen Ren, Qingmin Li, Yasuhiro Tanaka, Hiroaki Miyake, Haoyu Gao and Zhongdong Wang
Polymers 2021, 13(19), 3401; https://doi.org/10.3390/polym13193401 - 3 Oct 2021
Cited by 6 | Viewed by 2189
Abstract
In this paper, we studied the space charge phenomena of a solid polymer under thermal and electrical stresses with different frequencies and waveforms. By analyzing the parameter selection method of a protection capacitor and resistor, the newly built pulsed electro-acoustic (PEA) system can [...] Read more.
In this paper, we studied the space charge phenomena of a solid polymer under thermal and electrical stresses with different frequencies and waveforms. By analyzing the parameter selection method of a protection capacitor and resistor, the newly built pulsed electro-acoustic (PEA) system can be used for special electrical stresses under 500 Hz, based on which the charge phenomena are studied in detail under positive and negative DC and half-wave sine and rectangular wave voltages. Experimental results show that the charge accumulated in the polyimide polymer under DC conditions mainly comes from the grounded electrode side, and the amount of charge accumulated with electric field distortion becomes larger in a high-temperature environment. At room temperature, positive charges tend to accumulate in low-frequency conditions under positive rectangular wave voltages, while they easily appear under high-frequency situations of negative ones. In contrast, the maximum electric field distortion and charge accumulation under both half-wave sine voltages occur at 10 Hz. When the measurement temperature increases, the accumulated positive charge decreases, with a more negative charge appearing under rectangular wave voltages, while a more positive charge accumulates at different frequencies of half-wave sine voltages. Therefore, our study of the charge characteristics under different voltage and temperature conditions can provide a reference for applications in the corresponding environments. Full article
Show Figures

Graphical abstract

23 pages, 9777 KiB  
Article
A High-Frequency Isolation (HFI) Charging DC Port Combining a Front-End Three-Level Converter with a Back-End LLC Resonant Converter
by Guowei Cai, Duolun Liu, Chuang Liu, Wei Li and Jiajun Sun
Energies 2017, 10(10), 1462; https://doi.org/10.3390/en10101462 - 22 Sep 2017
Cited by 7 | Viewed by 10362
Abstract
The high-frequency isolation (HFI) charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs) through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC) resonant converter. The DC output [...] Read more.
The high-frequency isolation (HFI) charging DC port can serve as the interface between unipolar/bipolar DC buses and electric vehicles (EVs) through the two-power-stage system structure that combines the front-end three-level converter with the back-end logical link control (LLC) resonant converter. The DC output voltage can be maintained within the desired voltage range by the front-end converter. The electrical isolation can be realized by the back-end LLC converter, which has the bus converter function. According to the three-level topology, the low-voltage rating power devices can be adapted for half-voltage stress of the total DC grid, and the PWM phase-shift control can double the equivalent switching frequency to greatly reduce the filter volume. LLC resonant converters have advance characteristics of inverter-side zero-voltage-switching (ZVS) and rectifier-side zero-current switching (ZCS). In particular, it can achieve better performance under quasi-resonant frequency mode. Additionally, the magnetizing current can be modified following different DC output voltages, which have the self-adaptation ZVS condition for decreasing the circulating current. Here, the principles of the proposed topology are analyzed in detail, and the design conditions of the three-level output filter and high-frequency isolation transformer are explored. Finally, a 20 kW prototype with the 760 V input and 200–500 V output are designed and tested. The experimental results are demonstrated to verify the validity and performance of this charging DC port system structure. Full article
(This article belongs to the Collection Electric and Hybrid Vehicles Collection)
Show Figures

Figure 1

Back to TopTop